ZM24x Quick-Connect Industrial Modem. User s Manual

Similar documents
ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

Low Speed Modems for Dial and Leased Circuits 2400E (Standalone) 2400R (Rackmount)

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

ARC Modem Low Power Modem LP9624

CMM 900-3W USER GUIDE

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Cellular modem and Transceiver

Temperature Guard Models VM500-3 & VM500-3HT. Home Guard Model VM Operating Manual and Installation Instructions

Audio Cable (For CD Players Only) Sensor Board Cable

Temperature Guard Models VM500-3 & VM500-3HT. Home Guard Model VM Operating Manual and Installation Instructions

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc.

DIN Rail Mounted Dial-up Modem Users Manual

RocketPort Plus Hardware Installation

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

EX-UBT AVB/USB EXPANDER OPERATION MANUAL

RS-232 SERIAL INTERFACE PHOTOELECTRIC ISOLATOR

Media Converters. Media Converters. Product Selection Guides

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)

PCI Hardware Installation

xecom XE2486 Miniature 2400 bps Modem Module Description Features Block Diagram VCC Serial I/O ROM NVRAM Modem Controller Auxilliary I/O Tip

Second Phone Line Kit Manual for sx1480/fx2080

WS must be used in a temperature controlled place. It is compliant to ETS Class T

Owner s Instruction Manual

DATA CONNECT ENTERPRISE

TS-Modem User s Manual

Tote-A-Fax TOTE-A-FAX DATA SPEED FAX SPEED CARRIER DETECT LOW BATTERY. August 1992 FX112A CUSTOMER SUPPORT INFORMATION

RS-232 to RS-422/485 Converter with 3KV Isolation Protection

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

TCM-1 Beamtracking Ceiling Microphone TCM-1A Beamtracking Ceiling Microphone with Amplifier TCM-1EX Beamtracking Expansion Ceiling Microphone

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

An ISO-9001 Certified Company

User's Guide MD 14.4 Industrial Grade Dial Modems Book 1 of 2

AN_2901_005 JULY The Teridian 73M2901CE single chip modem implements the V.23 standard according the ITU V.23 recommendation.

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

CS485. User s Manual. Version ZYPEX, Inc.

CTI CALL INFORMATION INTERFACE

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

Telephone Switch Module. Model# TSM-1. User Guide. Santa Clara, CA (800) (972)

IMS-9000 Intelligent Modem Switch USER S MANUAL. Document Part #: RDC-HDWIMS9K100

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.

Canal+ Compatibility

RS-232 Industrial Media Converter

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

General Operating, Maintenance and Installation Manual

User Module. AT Modem Emulator APPLICATION NOTE

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

I/O Interface DNA300

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

Data Connect Enterprise IG56/IG336/IG144 Modems User s Guide

Conitel ASYNC Adapter

VISY-X. Technical Documentation. Cinterion MC 55 i. Edition: Version: 1 Article no.:

USER GUIDE. BLUETOOTH HEADSET system

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Sender Receiver Sender

GNS-MC35iT, GNS-MC35iU Terminals datasheet

edbox-100 SmartStack Box for PSTN

PRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning!

External Serial PC Watchdog User s Manual

IPC194. ipconv Protocol Converter

Serial Port Plug - F2M01SXA Brief Datasheet. Features. Applications. General Description. Provides transparent RS-232 serial cable replacement.

AT&T 7400B Data Module User s Guide

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

User's Guide MD 14.4L Industrial Grade Dial Modems Book 1 of 2

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

AT Commands - Trust 56K PCI Modem - Executing commands

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer

Channel Switch CS. General Operating, Maintenance and Installation Manual

RS K Ext Modem. User Manual

BIG BUTTON PHONE WITH ONE TOUCH DIALING AND

Universal communications device Metcom T A..

IC+ 56k External Data Fax Voice Modem IP568x User s Guide

Four IFB. Multi Line Phone Bridge. User Guide. JK Audio. Warranty

GT- IRDM-9603 Product description Rev. 2 17/06/2014

BLUETOOTH HEADSET system

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration

Models: TD3000 Series. Table Displays. 2 by 20 character display USER MANUAL

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

USB-TTL-5 PRODUCT IS A COMBINATION OF PRODUCTS USB AND TTL-232-5P BOTH DATASHEETS ARE INCLUDED IN THIS PDF FILE

Serial Interfaces Part 1. ECE 153B Sensor & Peripheral Interface Design Winter 2016

HEC. General Operating, Maintenance and Installation Manual

Do Not Copy. Important User Information For More Information... 3

DeviceMaster RTS 16-Port Hardware Installation

Select a Data Communication Interface

CS55H HOME EDITION... WIRELESS HEADSET SYSTEM

ASL Holdings Ltd. User Guide for the: - DELTA PLUS LAN modem. Provisional Ver1.8

Telephone Line Monitor USER GUIDE

RTU-COM PSTN AT. User Guide

Installation & Configuration manual. InduBox GSM IV

515RTAAIC Interface Converter

Sutron Voice Modem Operation Manual

AB300-Series Automated Filter Wheels

Transcription:

ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem

Since the equipment explained in this manual has a variety of uses, the user and those responsible for applying this equipment must satisfy themselves as to the acceptability of each application and use of the equipment. Under no circumstances will ZYPEX, Inc. be responsible or liable for any damage, including indirect or consequential losses resulting from the use, misuse, or application of this equipment. The text, illustrations, charts, and examples included in this manual are intended solely to explain the use and application of the ZYPEX, Inc. unit(s). Due to the many variables associated with specific uses or applications, ZYPEX, Inc. cannot assume responsibility or liability for actual use based upon the data provided in this manual. No patent liability is assumed by ZYPEX, Inc. with respect to the use of circuits, information, equipment, or software described in this manual. This manual was printed in the USA and is subject to change without notice. 2004 ZYPEX, Inc. All Rights Reserved. 2 ZM24x Quick-Connect Industrial Modem

Contents ZM24 Description 4 Operation 5 AT Command Summary 6 S Register Summary 8 Modem Result Codes 9 DIP Switch Settings 10 Connect Time 12 LED Indicators 12 Connectors 13 Specifications 14 FCC PART 68 Information 15 3 ZM24x Quick-Connect Industrial Modem

ZM24x Description The ZM24 is an industrial-grade modem designed to operate consistently and reliably under extreme electrical and temperature conditions. Dial-up networks where data transfers are short and connect time is important are ideal for use with the ZM24. Typical connect times are approximately 2.4 seconds. Polled systems and transaction based systems realize much better performance using the ZM24 than when using a 28.8K or 56K modem. Rugged transient protection and electrical isolation ensure that the ZM24 will function normally under a wide range of operating conditions. The case and electronics are designed to protect the modem from EMI/RFI interference. A wide input-range power supply allows the modem to operate over any voltage from 5 to 30 Vdc with very low current consumption. Low power consumption makes it ideal for battery operated and solar applications. 4 ZM24x Quick-Connect Industrial Modem

ZM24x Operation Data Format The modem uses the V.22bis protocol. The baud rate is set for 2400 baud, 8 data bits, no parity and 1 stop bit. Command Interface The ZM24 uses a subset of the Hayes AT command structure. The ZM24 is designed to connect to control and monitoring equipment with minimal effort. Custom interface options are available. Typical Operation The following details the setup and operation of a PC using ZM24s in a polled system. For typical operation, switches 3, 4, 5 and 6 are OFF, setting the fastest possible connect time. Switch 10 would be turned ON if verbose responses are desired, or turned OFF if single character responses are desired. Switch 11 controls the echo ON for enabled, OFF for disabled. Switch 12 enables auto answer. If auto answer is enabled, the modem will answer a call after the completion of the first ring. Originate Modem (PC) Switch 12 is typically turned OFF if auto answer is not required. A standard modem cable may be used to connect the ZM24 to a PC. To call another modem, the following sequence may be used: ATDT5551212. No other initialization strings are required. All commands are terminated by a carriage return. Either the RS-232 DCD signal or the returned ASCII responses (characters or strings) may be used to tell the PC that a connection has been established. The DCD signal will be asserted when the connection has been established and the modem is ready to send and receive data. The PC may then poll the remote equipment. To hang up, the PC can toggle the RS-232 DTR signal, or issue +++ (with a 1 second guard time on both sides) and then issue ATH to hang up. Answer Modem (Remote Equipment) Switch 12 is typically turned ON to enable auto answer. No initialization strings are required. The DCD signal may be used to indicate the presence of a valid connection. When the phone line connection is broken, the ZM24 will automatically hang up. Hayes AT is a registered trademark of Hayes Microcomputer Products, Inc. 5 ZM24x Quick-Connect Industrial Modem

AT Command Summary Command AT ATA ATDT ATE0 ATE1 ATH ATH1 ATI ATO ATS Description Attention Prefix Precedes all commands except the escape sequence (+++). All commands are terminated by a carriage return (CR). Force modem off-hook. Initiate Originate mode and dialing sequence. ZM24 will go off-hook and dial the sequence that follows. Valid digits: 0 9, *, #, A, B, C, or D Modifiers:, inserts a 2 second delay / inserts a 125ms delay Ignored characters:, -, (, ),. Disable character echo in command state. Also set by turning DIP Switch 7 off. Enable character echo in command state. Also set by turning DIP Switch 7 on. Hang-up This command causes the modem to go on-hook, and forces a hardware reset. Force modem off-hook without sending data. (Test mode command) Identification Returns firmware version number. Return to the on-line (connected) state from command state. Sets S Register (See table of valid S registers.) 6 ZM24x Quick-Connect Industrial Modem

ATTA ATTO ATV0 ATV1 ATZ Test Mode Command Forces modem off-hook, and sends pseudo random data in answer band. Test Mode Command Forces modem off-hook, and sends pseudo random data in originate band. Sets modem for numeric result codes. Also set by turning DIP Switch 6 off. Sets modem for verbose result codes. Also set by turning DIP Switch 6 on. Performs a hardware reset of the modem. +++ Escape Sequence When connected, the escape sequence returns the modem to the command state. The escape sequence must be preceeded and followed by a 1 second quiet time (no characters received from the RS-232 port). 7 ZM24x Quick-Connect Industrial Modem

S Register Summary ATS0=n Auto Answer Control Sets number of rings before modem answers an incoming call. 0 = auto answer disabled n = 0 9 This register is initialized on power up based on the DIP Switch 8 setting (see DIP Switch Settings). ATS7=n Connection Timeout Sets maximum time for a connection to be established. n = 2 255 seconds Default timeout is 30 seconds. 8 ZM24x Quick-Connect Industrial Modem

Modem Result Codes Numeric Verbose Description 0 OK Command executed 1 CONNECT Return to on-line mode from command mode 2 RING Ring signal detected 3 NO CARRIER Carrier signal lost 4 ERROR Invalid command 5 CONNECT 1200 Modem connected at 1200 Baud 6 NO DIALTONE No dial tone detected 7 BUSY Busy signal detected 8 NO ANSWER No answer from modem being called 10 CONNECT 2400 Modem connected at 2400 Baud Numeric response codes are enabled by turning DIP Switch 10 OFF, or sending the ATV0 command. Numeric responses are always terminated by an ASCII carriage return character. Verbose response codes are enabled by turning DIP Switch 10 ON, or sending the ATV1 command. Verbose responses are always terminated by ASCII carriage return line feed characters. 9 ZM24x Quick-Connect Industrial Modem

DIP Switch Settings Switch Description Switch 1 Switch 2 RS-232 Port Baud Rate Select OFF OFF 1200 Baud ON OFF 2400 Baud OFF ON 4800 Baud ON ON 9600 Baud Switch 3 Switch 4 Switch 5 Switch 6 Switch 7 Switch 8 Switch 9 Switch 10 Switch 11 Switch 12 RS-232 Link Speed OFF 2400 Baud, sets V.22bis mode ON 1200 Baud, sets V.22 mode Answer Tone Length OFF 425ms ON 3000 ms Answer Tone Delay OFF 250ms ON 2025ms Delay between Off-hook and start of answer tone Connect Delay OFF 0ms ON 6827ms Reserved Reserved Reserved (Test Function) Modem Response Format OFF Modem sends numeric response codes ON Modem sends verbose response codes Echo Control OFF Character echo in command state disabled ON Character echo in command state enabled Auto Answer OFF Auto Answer disabled (S0=0) ON Auto Answer enabled (S0=1) 10 ZM24x Quick-Connect Industrial Modem

All switches are only read when the modem is powered up. Modem power must cycled if any switch settings are changed. 11 ZM24x Quick-Connect Industrial Modem

Connect Time SW4 SW5 Connect Time OFF OFF 2.4 seconds ON OFF 5.0 seconds OFF ON 4.4 seconds ON ON 7.0 seconds Connect time is the time period between the modem going off-hook and the end of the training sequence. Data may be sent once the CONNECT LED is ON. The RS-232 DCD signal is also asserted at this time. If SW6 is ON, add 6.8 seconds to the above connect times. LED Indicators Indicator CONNECT AUTO ANS 3 Status LEDs (Upper Right) Description Modem connection has been established. Auto Answer is enabled. Command Mode: Data is being sent from the RS-232 port to the modem. Connect Mode: Data is being sent from the RS-232 port to the phone line. Command Mode: Data is being sent from the modem to the RS-232 port. Connect Mode: Data is being sent from the phone line to the RS-232 port. Alternating pattern when no RS-232 device is connected. Sequential pattern when RS-232 device is connected. All 3 LEDs will flash ON when an incoming ring signal is detected. 12 ZM24x Quick-Connect Industrial Modem

Connectors Power Connector Pin Signal Description 1 +V 5 to 30 Vdc 2 GND Common for Pin 1 3 Chassis Ground Connection to case and DB25 shell. RS-232 Connector (DCE) Pin Signal Name Direction Description 2 TXD Transmit Data Input Used to receive data being sent to telephone network and receiving AT commands. 3 RXD Receive Data Output Used to transmit data being received from the telephone network and send AT command results. 4 RTS Request To Send Input Used by modem to determine if DTE device is ready to send data. 5 CTS Clear To Send Output Asserted by modem to indicate ready to receive data from DTE device. 6 DSR Data Set Ready Output Asserted by modem to indicate operational status. 7 GND Ground Electrical ground. 8 DCD Data Carrier Detect Output Asserted when link has been established with another modem. This signal may be monitored instead of waiting for the ASCII CONNECT string. 20 DTR Data Terminal Ready Input Used by modem to indicate that an external device is connected to the RS-232 port. Toggling this signal will force modem to hang up. 22 RI Ring Indicator Output Asserted after a ring signal is detected from the telephone line. The RI output is pulsed high for 500ms after the ring signal stops. 13 ZM24x Quick-Connect Industrial Modem

ZM24x Specifications Data Rate Connect Time Configuration Interface Phone Line Power (5 to 30 Vdc) 5 Vdc 8 Vdc 12 Vdc 24 Vdc 30 Vdc Operating Temperature Range Transient Protection Power Input Telephone Line RS-232 Port Size Mounting 2400 bps (asynchronous) V.22 bis 1200 bps (asynchronous) V.22 2.4 seconds (typical) Hayes AT style command structure RS-232 DB25 female connector RJ11 connector Idle Connected (typical values) 58mA 78mA 38mA 50mA 28mA 36mA 18mA 21mA 15mA 18mA Removable 3-pin connector -40 C to +85 C 10% to 90% RH (non-condensing) Peak Pulse Power 600 watts (10/100us waveform) Peak Surge Current 100 amps (8.3ms single half sine-wave) FCC Part 68 Surge Specifications ESD Protected ±15kV Human Body Model ±8kV Contact Discharge ±15kV Air-gap Discharge 5.0 in. x 5.0 in. x 1.45 in. Optional Mounting Bracket 14 ZM24x Quick-Connect Industrial Modem

FCC PART 68 Information This equipment complies with Part 68 of the FCC Rules and the requirements adopted by ACTA. On the bottom of this equipment is a label that contains, a product identifier in the format US:AAAEQ##TXXXX. If requested, this information must be provided to your telephone company. A plug and jack use to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details. The REN is used to determine the number of devices that may connect to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact your local telephone company. For product approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the REN without the decimal point (e.q., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label. If this equipment (ZM24x) causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the proper functioning of your equipment. If they do, you will be notified in advance in order for you to make necessary modifications to maintain uninterrupted service. If trouble is experienced with this unit, for repair or warranty information, please contact customer service at the address and phone listed below. If the equipment is causing harm to the network, the telephone company may request that you disconnect the equipment until the problem is resolved. DO NOT DISASSEMBLE THIS EQUIPMENT. It does not contain any user serviceable components. We recommend the installation of an AC surge arrester in the AC outlet to which this equipment is connected. Telephone companies report that electrical surges, typically lighting transients, are very destructive to customer terminal equipment connected to AC power sources. 15 ZM24x Quick-Connect Industrial Modem

ATTN: CUSTOMER SERVICE DEPT. ZYPEX, Inc. 2795 E. Bidwell St. #100-405 Folsom, CA 95630 Phone: 916 983-9450 Fax: 916 983-9448 16 ZM24x Quick-Connect Industrial Modem