RION NA-27: SHORT-FORM INSTRUCTIONS

Similar documents
Sound Analyser Real Time 1/1 & 1/3 Octave band Analysis

TES-1358 INSTRUCTION MANUAL

Sound Level Meter NL-42 / NL-52 Quick Instruction Manual

LA-2111 LA-5111 and LA-5120 Sound Level Meter Measurement by 1/3 Real-time Octave Filter

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500

USER GUIDE. Noise Dosimeter with PC Interface. Model

USER GUIDE. Model Noise Dosimeter with PC Interface

AWA6223S Sound Level Calibrator. Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD

SERIAL INTERFACE MANUAL. Precision Integrating Sound Level Meter. with 1/3 octave band real-time analyzer NA-27

Visit us at Back to the Extech Product Page

LA-1440 and LA-4440 Sound Level Meter

Noise Explorer is a program for storing, retrieving and converting measurement data from Brüel & Kjær sound level and noise dose meters.

Podium Plus Data Analysis Software. User Manual. SWIS10 Version

Manual Sound level meter PCE-353

AEMLog Users Guide. Version 1.01

DS-3000 Series Data Station Operation manual for Vibration Analysis

CyberComm Pro Data Acquisition Software Installation & User Guide

Web Accessibility Change Your Mouse Pointer Visibility Handbook

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

Model S665. Sound Level Analyzer. Users Manual

SW860 FlukeView Software

AEMLog users guide V User Guide - Advanced Engine Management 2205 West 126 th st Hawthorne CA,

Process Eye Professional. Recall

Download Software User Guide Software Version

C-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6)

Noise Guide. Manual UK.

1. GENERAL DESCRIPTION & SPECIFICATIONS

Manual Sound level indicator PCE-353

HP 8714B Calibration

PicoLog for Windows user guide

CLASS 2 SOUND LEVEL METER WITH EXCEL-FORMATTED DATA LOGGING SD CARD USER S MANUAL

Podium Data Analysis Software. User Manual. SWIS10 Version

GP-1 Software Manual

SCANTROL. FishMeter SCANTROL. Electronic Fish Measuring Board. User Manual. Scandinavian Control Systems AS

Welcome to noiselab Express 1.0

SVAN 974. Vibration ANALYSER USER S MANUAL

NSRT_mk2. Data Sheet. June Bruno Paillard

PowerView for the EnergyPro

IECSoft. IEC Flicker and Harmonics Testing Software. USER MANUAL

Podium Data Analysis Software. User Manual. RCA40 Version

SD Model. Instruction Manual. Sound Level Meter/ Data logger. reedinstruments. www. com

HiTECH. Technologies, Inc. INSTRUCTION MANUAL. NIVOSONAR SM-300 CONFIGURATOR Program

TimerTools, v4.0 User s Manual. TimerTools 2006, 2011, 2017 Kagan Publishing

User Manual. Computer Program Pomiar Win. Version: 4.0.X. Manual number: ITKU A MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS

SOFTWARE STUTE.SCPI AUTOMATED MEASUREMENT

Greyline Logger. Greyline Logger

Castle Ultimus. Vibration Meter. Operating Manual. Revision A

USB Instruments EasyLogger for PS40M10 "Swordfish" Help

4-1. This chapter explains HMI settings.

DSM403SD USER S MANUAL

DPA-240A Digital Speaker Processor

QUICK START GUIDE FOR FIRMWARE UPGRADE RS232-TO UART INTERFACE BOARD AND SOFTWARE

Promethean ActivInspire

CEL-6702 db10 V2.0 to V2.3 & CEL-6704 db12 V2.0 to V2.4 CONTROL & DOWNLOAD SOFTWARE Users Handbook /HB-05

Xpert / XLite GPRS232 Serial Interface Block USERS MANUAL. Part No Rev. 3.3 July 27, 2009

Series Instruments System10

Personal Directory PC Utility Reference Guide

DATA ACQUISITION USING THE BIOPAC DATA SYSTEM

4-1. This chapter explains HMI settings.

NSRT_mk2. Data Sheet. June Bruno Paillard

Computer Essentials Session 1 Lesson Plan

SY061 Portable Load Meter with IEEE TEDS capability User Instructions

COMMUNICATION WITH OTHER SERIAL DEVICES

Integrating Sound Level Datalogger Model

PS-IN202 Weighing Indicator User Manual

TOF-Watch SX Monitor

NSRTW_mk2. Data Sheet. Nov Bruno Paillard

RS-232. ital Measurement Metrology, Inc ECISION IS OUR VISION LEVEL REC SETUP MAX MIN FAST SLOW INTV CLOCK.

Dash HF Family High Speed Data Acquisition Recorder

Personal Directory PC Utility Reference Guide

MEDALLION INSTRUMENTATION SYSTEMS MasterCraft Viper system

MATRIX 2 Podule. Description

Datalogger and RS232 Interface

Time History. Parameters Logged. Acoustical Parameters CHAPTER

CHEMINSTRUMENTS DYNAMIC SHEAR TESTER MODEL DS-1000 OPERATING INSTRUCTIONS

GeODin Basics Training. Introduction to GeODin

Wireless Circuits and Systems Laboratory

Table of Contents. Part I USB Communication. Part II User Interface. Part III User Settings (Tab Control) DFS-1000 Dataview. 2 File Menu.

OM-DLTH DATA LOGGER INSTRUCTIONS

INSTRUCTION MANUAL Sound Level Meter NL-27

7XI Console Set-Up. Warehouse Set-Up. 1 P age

The SolarTrak Prospector. CR-1000 Datalogger

The uscope Getting started

RT1. Real Time Spectrum Analyser Preliminary Operating Instructions

Computer Interface for Multi-Sensor Instruments

Calibration. Calibration Overview CHAPTER

Student Quick Reference Guide

SWR Director. (Version 1.11)

6. VELOCITY/TEMPERATURE CALIBRATION

DOWNLOAD KIT CYCLOCOMPUTER INTRODUCTION. Download unit & Download Software [e-train Data Ver.3] for Windows 98/ME/2000/XP

Note: For more information on creating labels in CDS, watch Volume 22 of the Fast Class Update: Label Creation.

CEL 240 Series Digital Sound Level Meters Frequently Asked Questions

NUAGE MASTER Ncs500-CT

GC-10 Wireless Control Box. User Guide

14 Digital Interface Operations

1 How do I download my PrimeTest 350 to PATGuard 2?... 2 How do I upload my PrimeTest 350 from. 4 How do I upload a logo to my tester for printing?...

METS methane sensor SOFTWARE MANUAL UNDERWATER SENSORS FOR DISSOLVED GASES

EUROLyser ConneXport

OM-DLTT DATA LOGGER INSTRUCTIONS

Precision Sound & Vibration Analyser Nor150

Transcription:

RION NA-27: SHORT-FORM INSTRUCTIONS 1. Quick-Start Guide 2. Guide to Downloading Stored Data JANUARY 2002

QUICK START GUIDE FOR THE RION NA-27 PRECISION INTEGRATING 1/3 OCTAVE REAL-TIME SOUND LEVEL ANALYSER 1. When the instrument is first switched on, the display will go through a self-test routine, the red INDICATOR will flash once a second and then the instrument display will present the SLM (L p or L a ) mode of operation. 2. The display is now indicating instantaneous sound pressure level L p and the bar graph display should be changing accordingly. 3. A calibration check can now be performed by using the supplied Rion NC-74 class 1 calibrator (94.0dB). 4. Check that the level range is sufficient for the measurement application. To change level ranges press the UP or DOWN keys to change level in 10dB increments. (NA-27 has a 70dB dynamic range (1/1 or 1/3 mode) and a measurement range of 10dB - 140dB). 5. Frequency weightings can be selected from a choice of LIN, A, & C, by pressing the FREQ WEIGHT key. 6. Time weightings can be selected from a choice of FAST, SLOW, 35mS or 10mS by pressing the TIME CONST key. 7. To obtain a Real-time 1/1 octave or 1/3 octave display, press the SLM 1/1 1/3 key to step through the Sound Level Meter mode, the real-time 1/1 octave display and the realtime 1/3 octave display, respectively. 8. The CAL key generates an internal calibration signal of 94.0dB @ 1kHz. 9. The OPE MODE key steps through the available measurement parameters such as:- L p, L eq, L max, L min, L 10, & L 90. 10. The GRP/NUM key will display the numerical data from either of the 1/1 octave or 1/3 octave display. 11. To start a measurement press the START/STOP key and a flashing icon will appear at the top of the display, (replacing the ) and is located in between MEAS and the elapsed time clock. In addition, the elapsed time clock will start to count up and the red LED INDICATOR lamp will flash once a second. 12. The PAUSE/CONT key has a 5-second back erase facility and can be used to erase unwanted events. An װ icon will appear in place of the flashing icon. 13. In the 1/1 or 1/3 octave display modes, and in order to highlight a particular frequency of interest there is a vertical Marker line which can be moved by pressing the right or left arrow keys to step through the centre frequencies and read off the frequency & level. This information is located under the MARK logo, situated to the centre & right of the display.

14. Whilst the instrument is in measurement mode, each of the measurement parameters can be observed without affecting the current measurements by pressing the OPE/MODE key repeatedly and stepping through:- L p, L eq, L E, L max, L min, & L 90. 15. To stop a measurement, press the START/STOP key. The measurement time is displayed at the top of the display. 16. Press the STORE key to store data in the instruments internal memory ( MANU manual store). The memory location number [00001] is located at the bottom right hand corner of the display. 17. To observe stored data press the RECALL key and RECL appears at the bottom left hand corner of the display, denoting that the information being observed is from memory. 18. To look at the contents of other memory locations, press the increment INC key or the decrement DEC key to step through the memory locations (maximum of 200 memory locations). 19. To return to real time measurement mode, press the RECALL key.

GUIDE FOR DOWNLOADING STORED DATA FROM THE RION NA-27 TO A PERSONAL COMPUTER OR LAPTOP PC 1. Switch instrument off using the POWER switch. 2. Connect one end of the RS-232-C interface lead to the 9-pin connector on the NA-27 and the other end to a vacant comms port on the PC. 3. Switch instrument on using the POWER switch. 4. Run the NA-27 software. 5. Set the comms baud rate to 38400 by selecting Instrument in the toolbar, clicking on Communication and selecting 38400 baudrate from the choices available. Ensure that the comms port number matches the one on the PC being used to download data. Click OK to accept. 6. Click on the sound level meter icon in the toolbar:- 7. A pop-up box appears where a filename, details of the measurement procedure, weather conditions, instruments used, etc., etc., can be added if required. (See Fig. 1) Click OK to accept. Fig. 1: Comments & Description

8. A second pop-up box appears titled Select store mode. The default is Manual store mode, therefore, (See Fig. 2) Click OK to accept. Fig. 2: Store Mode Selection Box 9. A third pop-up box appears titled Reading data, click OK to continue. 10. A fourth pop-up box appears in which the number of memory locations required to be downloaded is selected. Select the start memory location and the end memory location. (See Fig. 3) Click OK to accept. Fig. 3: Memory location selection box 11. A progress bar titled Reading data appears next (See Fig. 4) and will disappear once all of the selected data has been downloaded to the PC. Fig. 4: Data Download Progress Bar

12. To see the downloaded data in numerical format, click on View in the toolbar and click on View data. A pop-up box appears showing data from the first memory location (Address 1). To see subsequent data, click on Next. 13. To see downloaded data in graphical format, click on View in the toolbar and click on Bar graph view. A colour barchart representation of the data is shown and by use of the left or right cursor keys on the keyboard, an individual centre frequency can be identified. (See Fig. 5) Fig. 5: Bar Chart Display of 1/3 Octave Data 14. To save data as a Rion file *.NA click on File in the toolbar and select Save as option. Choose filename and file location as appropriate. Fig. 6: Save File Option Box

15. To save data as an ASCII text file *.TXT click on Data in the toolbar, then click on Export and a pop-up box appears. Select an appropriate filename and file location and before saving data, click in the Data separation box, delete the semi-colon (;) and insert a comma (,) in place of the default semi-colon. (See Fig. 3) Click on OK to save file to disk. Fig. 3: Data Export Settings Page ALWAYS CHECK THAT THE FILE HAS BEEN SAVED TO DISK 16. To close the NA-27 program click on File in toolbar and click on Exit to close the program.