Smart Grid Tie Microinverter User Manual

Similar documents
22-60VDC Grid Tie Microinverter User Manual

Smart Grid Tie Microinverter User Manual

GTI 300W GTI 500W GTI 600W GTI 800W GTI 1000W

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

Installation and Operations Manual INVOLAR MAC250 Microinverter

PRO-75 SERIES. User manual

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

Enphase S-Series Microinverter and Engage Cable Safety

User Guide. Control Box. RoscoLED TM.

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

Pure sine wave inverter. Product Manual

icore Kiosk system Installation Guide

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

M250 (M LL) Safety

User manual. Microinverter EVT248

EPS Power Supply

M215 (M215-60) Safety

Solis Single Phase Inverter

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

XTM1250SA DIN rail three phase four wire LCD display energy meter

GCI-2G-W Single Phase Inverter

-5K-2G. Solar PV Grid Tie Inverter. inverter. Installation and Operation Manual. 2013, Ningbo Ginlong Technologies Co., Ltd.

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

Octostrip ORDERCODE 42220

PV Module Installation Instructions

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

DOWNLOAD PDF ENPHASE M250 INSTALLATION GUIDE

Network Camera. Quick Guide DC-B1203X. Powered by

Installation/User Manual

1 Channel Strobe Controller ORDERCODE 40226

Operating instructions. Switching amplifier DN0210 DN / / 2015

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

SUN2000P-375 W Smart PV Optimizer. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

Solis Three Phase Inverter

Installation Guide for America Solar Wholesale Photovoltaic Modules

Redundancy unit CP-A RU

Solis Single Phase Inverter

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

MODEL C-HOMWA-1 CONNECTIVITY KIT, CONNEX (USB)

Network Camera. Quick Guide DC-D1223WX. Powered by

Flexoled FTP3HP RGB LED DMX Driver

D-Pack 6 Classic ORDERCODE 50315

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Installation, Operation and Maintenance Manual

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

MDM 011-Z1 Regen Resistor

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Electronic Temperature Controller. Instruction Manual Version

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

Meikai N220/N300 Micro-Inverter Installation and Operation Manual

Robot Light V2. User Manual

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11

Installation/User Manual

Ultra Slim Relays 24

DC-D2212R / DC-D2212WR

P OCKET POWER 6000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

PRO2DM DIN rail single phase two wire energy meter

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

LEGA ENERGY ELECTRONIC RELAY VOLTAGE STABILIZER VA USER MANUAL

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2

M215-Z Safety Information (M LL-IG-ZC)

V /06/ Velleman nv

LED SPIDER MOVING HEAD LIGHT

Operating instructions. Standstill monitor A / / 2011

HX1 Bluetooth Stereo Headset

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Operating instructions. Speed monitor D / / 2014

User Manual PUH4-H2. 4K HDMI Splitter 1x4. All Rights Reserved. Version: PUH4-H2_2016V1.2

Manual. Polaron SMPS Watt power supply for chargers. No. S2024. Copyright Graupner/SJ GmbH

PV Rapid Shutdown device

4 Port USB Power Hub. Model: JH-800 USER MANUAL

Manual Version: V1.00. Video Decoder Quick Guide

TeckNet N9 Laptop Cooling Stand

Installing and Configuring Rialto Analytic Appliances

Crossfire. User Manual. Order code: EQLED061

PHOENIX CONTACT - 07/2006

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

MC 11 EB-2 Power supply cabinet with external bus, AC version

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

B-Box H Installation Guidance

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Party Dimmer IEC ORDERCODE 50324

UV Power Flood. User Manual. Order code: EQLED029

Blitzer Strobe. User Manual. Order code: EQLED366

CS2 DMX Distribution Splitter

CEM-C6 INSTRUCTION MANUAL (M187B B)

4170 POS System Installation Guide

Transcription:

Smart Grid Tie Microinverter User Manual Thanks for choosing Smart Microinverters. Read the following instruction carefully before installation and operating, install and operate as specified by this user manual strictly.

Catalogue Smart Microinverter Introduction......1 Important Safety Information 2 Technical Parameters.....4 Installation.....5 LED Indicators......7 General Troubleshooting.....8 Stack Wiring Diagram.. 9 Warranty...10 Warranty Card....11 Explore Applications Diagram.....13 Any relevant alteration is subject to the latest version without any prior notice.

Smart Microinverter Introduction Smart grid tie inverter is a compact unit, which directly converts direct current into alternating current for powering appliances and/or office equipments and connecting to utility grid. The output from Smart Microinverter is synchronized and in-phase with the utility grid. It is a key device of power generation systems such as PV power generation system, wind turbine power generation system. Smart Microinverter specially optimized design to work with modularization of power supplies which includes the mainstream solar modules, 18V (36 cells), 24V (60 cells) and 36V (72 cells) monocrystal and/or Polycrystalline solar panels, wind turbines and batteries. Smart Microinverters are stabilization, reliable and high conversion efficiency items. It is the best choice for PV power generation systems. Smart Microinverter can be easily placed and attached to the rack underneath of PV module. No need spaces for independent installation and low voltage wire connects from the PV module to Smart Microinverter can eliminate the risk of high voltage. Distributed modularization design philosophy for Smart Microinverter insures the productiveness of the whole system and will not affect by a single point of failure. Each Smart Microinverter is individually connected to each PV module in the array. This unique configuration means that an individual Maximum Peak Power Point Tracker (MPPT) controls each PV modules and insures that the maximum power available from each PV module is exported to the utility grid regardless of the performance of the other PV modules in the array which may be affected by shading, soiling, orientation or mismatch, etc. Smart Microinverter insures top performance for maximizing energy production from the whole PV system and gets return on investment in less time. 1

Features of Smart Microinverter 1. Unique circuit design, choice of import industrial electronic components, higher efficiency, more stable performance. 2. Creative MPPT technology, efficiency more than 99%, faster and more sensitive reaction, more reliable. 3. Parallel type design for input and modularization design for inverter, small volume, distributed installation, easy for system configuration, flexible for combination, strong expansibility of system. 4. Adopting high-frequency isolation transformer type, high efficiency, and high security. 5. Perfect electrical protection function. 6. Aluminum alloy housing, not rust, heat-resisting and cold-resistant as well as anti-corrosion. 7. Getting electronic circuit design, appearance design and other core technology patents. 8. Wide input voltage (15-60V), classification processing for different input voltages. It can work with different power supplies. Important Safety Information Read This First This manual contains important instructions for use during installation and maintenance of the Smart Microinverter. To reduce the risk of electrical shock, and to ensure the safe installation and operation of the Smart Microinverter, the following safety symbols appear throughout this document to indicate dangerous conditions and important safety instructions. DANGER! This indicates a hazardous situation, which if not avoided, will result in death or serious injury. WARNING! This indicates a situation where failure to follow instructions may be a safety hazard or cause equipment malfunction. Use extreme caution and follow instructions carefully. NOTE: This indicates information particularly important for optimal system operation. Follow instruction closely. 2

Safety Instruction Do not use Smart Microinverter in a manner not specified by the manufacturer. Doing so may cause death or injury to persons, or damage to equipment. Perform all electrical installations in accordance with all applicable local electrical codes. Be aware that only qualified personnel should disassemble and repair the Smart Microinverters and non-qualified personnel should not install and/or repair. Do not attempt to repair the Smart Microinverter; it contains no user-serviceable parts. If it fails, contact customer service to claim a return merchandise authorization and start the replacement process. Tampering with or opening the Smart Microinverter will void the warranty. If the cable connector on the Microinverter is damaged or broken, do not install the unit. Before installing or using the Smart Microinverter, read all instructions and cautionary markings in the technical description and on the Smart Microinverter System and the PV equipment. Connect the Smart Microinverter to the utility grid only after you have completed all installation procedures and after receiving prior approval from the local electrical utility company. Be aware that the body of the Smart Microinverter is the heat sink. Under normal operating conditions, the temperature is 15 C above ambient, but under extreme conditions the Microinverter can reach a temperature of 75 C. To reduce risk of burns, use caution when working with Microinverters. Our suggestion is that do NOT disconnect the PV module from the Smart Microinverter without first removing power when Smart Microinverter still operation because it may cause of components damaged. Keep away from children, no touching, no playing so as not to electric shock when using. Please installed in place of low humidity and well-ventilated so as to avoid inverter overheating, as well as clear around the inflammable and explosive materials. 3

Technical Parameters Suitable for 72 cells solar panel which Vmp is 35-39V and as Voc is 42-46V. Rated Power 200W 300W 400W 500W 600W Solar Panels 200W 300W 400W 500W 600W Input Range 15-60V MPPT Voltage 18-48V MAX. Current 15A 20A 30A 45A 50A Output Range Frequency Range 120V(90-140V) or 230V(190-260V) 50Hz/60Hz(Auto control) Power Factor >97.5% THD <5% Phase Shift <2% Efficiency 120V(90-140V) Peak Efficiency >88% >88% >86% >85% >85% Stable Efficiency >86% >86% >85% >84% >83% Efficiency 230V(190-260V) Peak Efficiency >90% >90% >88% >88% >85% Stable Efficiency >88% >88% >86% >86% >84% Protection Islanding; Short-circuit; Converse Connection; Low Voltage; Over Voltage; Over Temperature Protection Work Temperature -25-65 Work Humidity Grade of Waterproof Show Cooling Stand-by Power EMC Grid Disturbance Grid Detection Certificate Mounting dimension 0%~90%RH non-condensing Indoor Design Luminous Diode (LED) Fan <2W EN61000-6-3:2007 EN61000-6-1:2007 EN 50178+EN 62109-1+VDE0126-1-12 DIN VDE 1026 UL1741 CE 16 x 13CM 4

50Hz 60Hz 230V 125V FAULT voltage display frequency display LOW ST HIGH Voltage Range Display Adjustment Powe r Output Display Packing Specification Packing Accessory Mechanical Size Net Weight/PCS Inner Box (L x W x H) Carton(L x W x H) Microinverter, Cord, User Manual, Warranty Card 21 x 16.5 x 5.3CM 1.3KGS/PCS 31 x 21 x 11.5CM 42 x 31.5 x 35.5CM; 6PCS/CTN, 8/11KGS Installation 1. Diagrammatize input and output terminals. Cooling Fan Input Positive Led Indicators FUSE 30A 30A Fuses Input Input Negative MAINS (Grid Tie Output) Air Intake GRID TIE INVERTER START SWITCH Switch Output Socket 2. Attach the Smart Microinverter to the racking or fix onto the wall. Fixed Screw Grid tie inverter 3. Properly connect the positive and negative of solar panel and Smart Microinverter. FUSE Input 30A 30A 5

4. power cable connects with Smart Microinverter and residential power grid which refers to low voltage civilian single-phase power grid. Connecting with family grid MAINS (Grid Tie Output) GRID TIE INVERTER frequency display 50Hz LOW HIGH 60Hz Voltage Range Display 230V ST 125V Adjustment FAULT Power Output Display voltage display START SWITCH Switch Power Cord 5. Switch on power grid after check for input and output connections are correct and then switch on the Smart Microinverter. All LEDs lights up and off, and next LEDS flash start from fault red LED, it means that Smart Microinverter operating for working environment detection. When Fault red LED, voltage display LEDs, frequency display LEDs, voltage range display LEDs lights up at the same time and then fault red LED lights off follow on and blue ST LED and power output display LEDs flash quickly, it means that Smart Microinverter is working and power is increasing. When blue LED starts flash slowly, it means that Smart Microinverter is run for MPPT operation. Finally when blue LED long light, it means that maximum power point lock-in. When red power output display LEDs start to run up and down, it means Smart Microinverter proper functioning and output steady. The more output power, the faster red power output display run. Grid tie inverter 6

LED Indicators 50Hz 60Hz frequency display LOW HIGH 230V 125V FAULT voltage display Voltage Range Display ST Adjustment Power Output Display 1. Red LED 1.1 Red FAULT LED indicator lights up under any conditions as listed below: a) Low-voltage protection( input voltage lower than Min. input voltage of inverters ). b) Over-voltage protection ( input voltage higher than Max. input voltage of inverters). c) Over-temperature protection (inverters will be shut down for power output when the temperature of body of inverters higher than 65-75.) And inverter will be automatically restart up when the temperature of body of the inverter down to 40-50. d) Power grid fault protection (when 110V or 220V grid power outage and/or tripped. e) Islanding protection: inverter will be automatically shut down for power output when disconnect with power grid. f) Short-circuit protection: inverter stops work when output line short-circuits. 1.2 Red LOW indicator: input voltage lower than 37V 1.3 Red High indicator: input voltage higher than 37V 1.4 Red Power LED indicator: Follow the inverter power output size flow flashing quickly or slowly. 2. Blue ST LED a) Blue LED flash: adjusting for power output, MPPT operating for tracking. b) Blue LED long light: indicates inverter locking-in Max. output power operation status. 3. Green LED a) 120V/230V indicators: associated LED lights up when run for power grid voltage detection. b) 50/60Hz indicators: associated LED lights up when run for frequency detection. 4. Please note that above operations only run at grid-connected status. 7

Troubleshooting a Non-operating Smart Microinverter 1. System halted and /or without power output a) Check if switch of Smart Microinverter is turn on or not. b) Check if the connections to Smart Microinverter are correct or not. c) Check if any reverse connections for positive or negative or not. d) Check if input voltage is within the range of the Smart Microinverter s or not. e) Check if the utility grid voltage and frequency are fit in with the serviceable range of Smart Microinverter or not. f) Check if fuses of side are fusing or not. g) Check if utility grid voltage properly connecting to Smart Microinverters or not. 2. power supply is normal but no power output: a) Check if utility grid voltage is connecting to Smart Microinverter or not. b) Check if utility grid voltage is fit in with the serviceable range of Smart Microinverter or not. c) Please visual inspection for the LED operation status, red LED will turn off and green LED will flash or run when inverter connecting with power supply which input voltage is fit in with the range as specified and power grid properly. If still no power output when green LED flash or run, probably internal components are damaged, in such case, please turn the defective inverter back for further analyze. d) Please visual inspection for the LED operation status, red LED still turn on and green LED without any flash or run when inverter connecting with power supply which input voltage is fit in with the range as specified and power grid properly, probably internal components are damaged, in such case, please turn the defective inverter back for further analyze. 8

Smart Microinverter Stack Wiring Diagram Solar Panel Solar Panel Solar Panel Grid tie inverter Grid tie inverter Grid tie inverter 1 2 3 N Power Grid Meter Two-way Meter Family Load Smart Microinverter Three Phase output Wiring Diagram Solar Panel Solar Panel Solar Panel Grid tie inverter Grid tie inverter Grid tie inverter N N 1 1 1 N L1 L2 L3 N 9

Warranty Warranty Conditions Warranty Period: 15-year limited warranty period. Warranty Evidence: The B/L, Product(s) series number(s), Product(s) model, and a completed warranty card. We grant from date month year to date month year. If your device has a defect or malfunction during the warranty period, please contact your retailer or installer. Warranty claims are excluded for: Alterations or repairs to the unit without prior authorization Improper use or operation of device Improper and non-standard installation Operating the equipment with defective safety devices Impact of foreign objects and force majeure (lightning, surge, storm, fire) Inadequate or nonexistent ventilation of the device Disregarding of safety regulations Shipping damage The Product has been improperly stored or was damaged while in possession of the Dealer or end user; WARNING! Only qualified electrical professionals can do the trouble shooting of the Smart Microinverter system. WARNING! Please turn off the Smart Microinverter first and then disconnect the grid before disconnecting the Smart Microinverter from the PV module when remove the inverter from the rack. WARNING: Do not attempt to repair the Smart Microinverter. This may bring electrical hazard to the person and it will also void the Microinverter warranty. If troubleshooting methods fail, please contact customer support to return the Microinverter and initiate for replacement process. 10

Warranty Card(Invalid Duplicate) Customer Feedback: Name Country and/or Territory Telephone Email Purchase Channels and/or Sources Models/Power Date of Purchase Date of Installation Time of Using Brief Fault Description Improvement Suggestions Distributor and/or Sales Representative Distributor Name Telephone and/or Email Sales Representative Date of finish Disposal Date of Customer Feedback Disposal QC Others Technician 11

Other Supplementary Comments or Descriptions from Customers 12

Explore Applications Diagram 1. Work with 72cells solar panel(vmp: 35-39V, Voc: 42-46V) Solar Panel Feed into Residential Grid Power Grid Grid tie inverter Two-way Meter 2. Work with wind turbine, output voltage is fit in with the range as specified and a 36V charge controller needed to be used if the wind turbine without build-in TO charge controller. Small Power Wind generator Controller Wind Generator / Charge Controller Grid tie inverter Feed into Residential Grid 3. Work with battery, PV module and wind turbine charging the battery and battery discharging to inverter for converting power which will feed into power grid. Two-way Meter Power Grid Solar Panel Solar Charge Controller Battery Feed into Residential Grid Power Grid Grid tie inverter Small Power Wind generator 控制器 Wind Generator / Charge Controller Two-way Meter 13