Signal Isolators & Conditioners

Similar documents
Signal Isolators & Conditioners

Signal Isolators & Conditioners

Signal Isolators & Conditioners

RTD Temperature acquisition converter WJ25

Analog signal to RS485 or RS232 Converter, A/D Converter

JSD81 series products are based on SCM's intelligent monitoring and control system, users set the calibration value,

Signal Isolators & Conditioners

Amazing Electronic (HK) Limited Serial RS232/RS485 to analog signal converter

ISO AD A08 8-channel isolated 4-20mA Signal Acquisition Module ⅠProduct Introduction

8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user

I-7021, I-7022, I-7024, M-7022, M-7024 and M-7028 Series User Manual

Input Channels: 4 differential or four single-ended. Address / Baud rate / range configurable by the user

ZB-2024 Series User Manual

OMR-6021 Analog Output OMR Channel Analog Output

EX9017H-M is a analog input module with 8 input channels. Eight channels are differential type and individual channel configuration support.

Warranty. Warning. Copyright. Contact Us

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

I-7000 and M-7000 DIO User Manual

SY Series Data Acquisition Isolation Transmitter

8520/8520R. User Manual

I-7000 and M-7000 DIO User Manual

NuDAM. ND-6021 Analog Output ND Channel Analog Output

SER-4485-SI-M USER S MANUAL

ADAM Data Acquisition Modules User's Manual

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

CAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port

KTA-250 Anemometer Alarm Card

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

Features. Target Applications. V1.6 TBS07 RS485 to SDI-12 Converter

8017, 8018, 8019, 8017, M-8018, M-8019 Series User's Manual

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

Analog Input Modules User s Guide

4.6 Digital I/O and Relay Output Module Command

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Carbon Monoxide Sensor - ModBus

RS-FX-N01 wind transmitter user's Guide (485type)

I-7017, I-7018, I-7019, M-7017, M-7018 and M-7019 Series User Manual

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Trident and Trident X2 Digital Process and Temperature Panel Meter

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

GFK-2415A March Type of sensor connection

The I-7530A-MR Modbus RTU to CAN Converter

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

INSTRUCTION SHEET. Eaton Logic Controller DeviceNet Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CADNET

Forcom Technology Co., Ltd. Intelligent RS-485/422 to RS-232 converter

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

NuDAM-6011/ NuDAM-6014D NuDAM-6012/D NuDAM-6017 NuDAM-6013/ NuDAM-6018 Analog Input Modules User s Guide

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

RS-FS-N01 Wind speed transmitter user's Guide (485type)

User Manual ADAM 4000 Series. Data Acquisition Modules

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

I/O SIGNAL CONDITIONER

Eaton Logic Controller Modbus Distributed I/O Adapter Module INSTRUCTION SHEET

USB-1208LS Specifications

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

i-7005 and M-7005 User s Manual

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

MDA-8000 DIO User Manual

OMR-6011/D OMR-6014D OMR-6012/D OMR-6017 OMR-6013 OMR Analog Input Modules

RS485 MODBUS Module 8AO

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

User s manual. Programmable panel meter IPD

Product Specification for SAB-S-MODBUS

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE

Specifications minilab 1008

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ISO-DA16/DA8. Hardware Manual

MODEL 9250 Preliminary data sheet

1. Introduction. 2. Installation MODBUS INTERFACE

The I-7530A RS-232/485/422 to CAN Converter

USER GUIDE PEL 8K / PEL 8K-M

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

RS 485 Mini Modbus 1AO

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

ZM24x Quick-Connect Industrial Modem. User s Manual

UniPak UP448 Bridge Input Isolating Signal Conditioner

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.

USER GUIDE PEL / PEL-M

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

PAS 9737/AI-SMT ENGINEERING SPECIFICATION

iologik E1200H Series

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

General Specifications. P2-SCM Serial Communications

RS-485 I/O Modules: ADAM-4000

Masibus Automation And Instrumentation Pvt. Ltd.

FP-RTD-122. Introduction CALIBRATION PROCEDURE. Version 2.0

8013,8013D, 8033 User Manual

Electrical Energy Meter with integrated Serial Modbus interface

P3-SCM. General Specifications

Features and Benefits. Certifications

TIP550. Optically Isolated 8/4 Channel 12-bit D/A. Version 1.2. User Manual. Issue October 2009

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Transcription:

RS485/232 to Analog Signal Converter Signal Isolators & Conditioners (D/A Converter,WJ31 series) Features: >> RS-485/232 interface, isolation convert standard analog signal output >> Analog signal output accuracy is better than 0.2% >> Can calibrate module output accuracy >> Signal output / communication interface isolation voltage 3000VDC >> Wide supply range: 8 ~ 32VDC >> High reliability, easy programming, easy to install and wiring >> User-programmable settings module address, baud rate, etc. >> set the host to read the WJ21 product data to the remote collection >> Supports Modbus RTU protocol >> DIN35 Rail-mounted Typical Application: >> Standard analog signal output >> Intelligent building control, security and engineering applications >> RS-232/485 industrial automation control system >> Industrial control signal isolation and long-term transmission >> Equipment debug and control >> Sensor signal remote transmission >> Implementation of the industrial field data given Figure 1 WJ31 >> Medical, industrial products development >> 4-20mA signal output Product Overview: The WJ31 series realize host RS-485/232 interface signal isolation converted into a standard analog signal, to control the remote device. WJ31 products can be applied to RS-232/485 bus industrial automation control system,4-20ma / 0-5V/0-10V standard signal output, to control industrial site execution set equipment, control equipment and display instrument. Products include power supply isolation, signal isolation, linearization, D/A conversion and RS-485 serial communication. Each serial interface can connect up to 256 pieces WJ21 Series modules, communication using ASCII code or MODBUS RTU communication protocol, and its instruction set compatible with the ADAM modules, baud rate can been set by the code, with other manufacturers control module hang in the same RS-485 bus for easy programming. Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 1 of 12

WJ31 series products are based on SCM's intelligent monitoring and control system, users set the calibration value, address, baud rate, data format, checksum status, and configuration information are all stored in nonvolatile memory EEPROM. WJ31 products are according to industry standard design, isolation between signal output / communication interface, can withstand voltage 3000VDC, high anti-interference ability and reliability. Operating temperature range is - 45 ~ +85 C. Function Description: WJ31 signal isolation D / A converter module can be used to output one channel voltage or current signal, can also be used to output two common ground current or voltage signal. 1. Analog signal output 12-Bit acquisition accuracy, all products signal input range have been calibrated. In use, users also can program calibration easily. About the specific current or voltage input range, please see product selection. when need two channels signal output, signal value must be the same. 2. Communication protocol Communication Interface: one channel standard RS-485 communication interface, or one standard RS-232 communication interface, specify when ordering. Communication Protocols: supports two protocols, characters protocol of the command set defined and MODBUS RTU communication protocol. Can be programmed using the kind of communication protocol, can be achieved with PLC, RTU of many Brands or computer monitoring system for network communication. Data Format: 10 Bits. 1 start bit,8 data bits,1 stop bit. Address: (0 to 255) and baud rate (2400,4800,9600,19200,38400 bps) can be set, the most long-distance about communication networks is up to 1200 meters, through the twisted-pair shielded cable. Communication interface of high anti-jamming design, ± 15KV ESD protection, communication response time is less than 100mS. 3. Anti-jamming According to need to set the checksum. Module internal has transient suppression diodes, can inhibit a variety of surge pulse, protection module, and internal digital filter can also be well suppressed from the grid frequency interference. Product Selection: WJ31 U(A) Interface Output Voltage or Current Signal 485:Input is RS-485 interface U1:0-5V A1:0-1mA 232:Input is RS-232 interface U2:0-10V A2:0-10mA U3:0-75mV A3:0-20mA U4:0-2.5V A4:4-20mA U5:0-±5V A5:0-±1mA U6:0-±10V A6:0-±10mA U7:0-±100mV A7:0-±20mA U8:user-defined A8:user-defined Sample 1: part No.:WJ31 485-A4 Input is RS485 interface, 4-20mA signal output Sample 1: part No.:WJ31 232-U1 Input is RS-232 interface,0-5v signal output General parameters: (typical @ +25, Vs to 24VDC) Output type: current / voltage signal Accuracy: 0.2% Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 2 of 12

Output maladjustment: current output ± 0.5 ua / C, voltage output of ± 0.1 mv / C Temperature drift:± 20 ppm / (± 30 ppm /, maximum) Output load capacity: current output 350Ω (4-20mA/0-20mA/0- ± 20mA current output) voltage output 10mA (0-5V/0-10V/0- ± 5V voltage output) Communication: RS-485 protocol or RS-232 standard characters protocols and MODBUS RTU communication protocol Baud Rate (1200,2400,4800,9600,19200,38400 bps) can be selected via software Address (0 to 255) can be selected via software Communication Response Time: 100 ms maximum Power Supply: +8 ~ 32VDC wide range power supply, internal anti-reverse and over-voltage protection circuit Power Loss: less than 1.5W Operating Temperature: - 45 ~ +80 Humidity: 10 ~ 90% (no condensation) Storage Temperature: - 45 ~ +80 Storage Humidity: 10 ~ 95% (no condensation) Isolation Voltage: communication interface / output: 3KVDC, 1 minute, leakage current:1ma Which communication interface and power supply are common ground. Shock Voltage: 3KVAC, 1.2/50us (peak) Dimensions: 106.7 mm x 79 mm x 25mm Footprint Function: PIN Name Function PIN Name Function 1 PW+ Power+ 7 OUT 0+ Analog signal output 0+ 2 GND Power- 8 GND 1 Analog signal output 0-3 INIT Initialization state set 9 NC NO PIN 4 D+ RS-485 signal+ 10 OUT 1+ Analog signal output 1+ 5 D- RS-485 signal- 11 GND 1 Analog signal output 1-6 GND Power-,Output port ground 12 NC NO PIN Figure 3 Top View WJ31 Wiring Diagram Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 3 of 12

Initialization WJ31 modules: All WJ31 modules, if you use RS-485 network, must be assigned a unique address code, address code value of hexadecimal numbers between 00 and FF. However, all new WJ21 module uses a factory initial settings, as follows: Address code: 01 Baud rate: 9600 bps Checksum is disable As the new module address codes are the same, their address will be contradictory to other modules, so when you set up the system, you must reconfigure each WJ31 module address. WJ31 module can be connected the power cord and RS485 communication lines, through configuration commands to modify the WJ31 module address. Baud rate, parity and status, communication protocols also need to be adjusted according to user requirements. In the modified baud rate, parity and status, communication protocol, you must first enter the module to the default state, or can not be modified. Let the module into the default state: WJ31 module has a special INIT pin. Connecting the INIT PIN to ground (GND PIN), then open power, the module into the default state. In this state, the module is configured as follows: Address code 00 9600 bps baud rate Checksum is disable At this time, via configuration commands you can modify the WJ31 module baud rate, parity, checksum state and other parameters, by setting the module communication protocol command to select the communication protocol. When are not sure a module specific configuration, can also be configured by installing the jumper, so that the module into the default state, then reconfigure the module. If clients need set the module to MODBUS RTU communication protocol, see the MODBUS protocol section for instructions. WJ31 character protocol command set: Order is by a series of characters, such as first code, address ID, variables, an optional checksum byte and a terminator (cr) which can show command. In addition to wildcard address ** synchronization command, the host only commands a WJ21 module once. Command format: (Leading Code) (Addr) (Command) [data] [checksum] (cr) (Leading code) prefix is the first letter of the command. All commands require a command prefix, such as %,$,#,@,... etc. 1 - Character (Addr) module address code, if not specified below, range is from 00 ~ FF (hexadecimal). 2 - Character (Command) shows the command code or variable values. Variable length [Data] some output command needs data Variable length [Checksum] brackets Checksum (checksum) shows an optional parameter, only the checksum is enabled, need this option. 2 - Character (Cr) a control code character as identify, (cr) as a carriage return character, its value is 0x0D. 1 - Character When enabled checksum (checksum), users need [Checksum]. It accounted for 2 - character. Commands and responses must be attached checksum feature. Checksum used to check all input commands to help you find the host to the module command module to the host response to errors and mistakes. Checksum characters placed in command or in response to the character after the carriage return before. Calculated as follows: two characters, the hexadecimal number for all issued prior to the ASCII values of and, then with hexadecimal digits 0xFF phase proceeds. Examples: Disable checksum (checksum) command: $002(cr) response:!00020600 (cr) Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 4 of 12

Enable checksum command: $002B6 (cr) response:!00020600 A9 (cr) $ = 0x24 0 = 0x30 2 = 0x32 B6=(0x24+0x30+0x30+0x32) AND 0xFF! = 0x21 0 = 0x30 2 = 0x32 6 = 0x36 A9=(0x21+0x30+0x30+0x30+0x32+0x30+0x36+0x30+0x30) AND 0xFF Command response: Response message depends on a variety of commands. Response also is consists of several characters, includes leading code, variables and end tags. The first code of response signal has two:'!' Or '>' indicates that a valid command and '?' means invalid. By checking the response information, you can monitor whether the command is valid Note: 1. In some cases, many commands use the same command format. To ensure that you use a command in the address is correct, if you use the wrong address and this address represents another module, then the command will take effect in another module, resulting in an error. 2. the command must be entered in uppercase letters. 1 Set Channel N Analog Output Value Command Description: set analog output module channel N output value Command Format:#N(data)(cr) Parameter:# delimiter character module address, (range 00-FF). Factory address is 01, converted to hexadecimal ASCII code for each character. Such as address 01 into hexadecimal are 30H and 31H. N Channel code 0 or 1.Change to hexadecimal are 30H and 31H (data) set channel N reset output analog value.the data format is in Engineering Units,Percent of FSR, Two s complement hexadecimal. Refer to Chapter 3 Command Set. (cr) is the terminating character, carriage return (0Dh) Response : >(cr) command is valid.?(cr) invalid command or illegal operation Parameter: > delimiter character Example: Command(Character format) #010+16.000(cr) (Hexadecimal format) 233031302B31362E3030300D Response (Character format) >(cr) (Hexadecimal format) 3E0D The channel 0 output value is +16.000mA at setting address 01H module. 2 Set Channel N Reset Analog Output Value Command Description:Set Channel N Reset Analog Output Value as the present data formats. Command Format:#SN(data)(cr) Parameter: # delimiter character module address (range 00-FF) hexadecimal. Factory address is 01, converted to hexadecimal ASCII code for each character. Such as address 01 into hexadecimal are 30H and 31H. S set reset analog output value N Channel code 0 or 1. Change to hexadecimal are 30H and 31H (data) set channel N reset output analog value.the data format is in Engineering Units,Percent of FSR, Two s complement hexadecimal. Refer to Chapter 3 Command Set. Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 5 of 12

(cr) is the terminating character, carriage return (0Dh) Response : >(cr) command is valid.?(cr) invalid command or illegal operation Example: Command #01S0+04.000(cr) Response >(cr) The channel 0 reset output value is +04.000mA at setting address 01H module. 3 Set Analog Output Module Command Description: Set address, output ranges, baud rate, data formats, checksum and state for a analog output module, counter data are stored in a EEPROM. Command Format: %NNTTCCFF(cr) Parameter : % delimiter character module address, (range 00-FF) hexadecimal. Factory address is 01, converted to hexadecimal ASCII code for each character. Such as address 01 into hexadecimal are 30H and 31H. NN indicates new module hexadecimal address, value NN range is 00~FF TT hexadecimal indicates type code.wj31 must been set 00 CC Baud Rate code (hexadecimal) Baud rate code Baud rate 04 2400 baud 05 4800 baud 06 9600 baud 07 19200 baud 08 38400 baud FF Table 2 Baud rate code Hexadecimal 8-bit represents the data format, checksum. Note: from bits2 to bits5 need not been set to zero. Bit7 Bit 6 Bit 5 Bit 4 Bit 3 Bit2 Bit 1 Bit 0 Table 3 Data format, checksum and code Bit7:Reserved bits (must set to 0) Bit6:checksum states, if 0:Disabled, if 1: Enabled Bit5-bit2:Not used(must set to 0) Bit1-bit0:Data Format Bit 00:Engineering Units 01:% of FSR 10:Twos complement hexadecimal 11: ohms(only for RTD products ) Response:!(cr) command is valid?(cr) command is invalid or illegal operation, or do not set up line before changing baud rate or checksum Parameter Description:! delimiter character which indicates a valid command.? delimiter character which indicates a invalid command. represents input module address Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 6 of 12

If you configure module for the first time, =00 and NN equal to new address. If reconfigure module changing address, input range, data formats, equals to present configured address, NN equals to the current or new address. If reconfigure module changing baud rate or checksum state, must install command string, make them in listening mode, module address is 00H, also =00H, NN=present or new address. Example: command %0011000600(cr) response!11(cr) Description: % delimiter character 00 indicates analog output WJ31 module original address set to 00H. 11 indicates new module hexadecimal address is 11H 00 indicates type code, WJ31 must been set to 00 06 indicates baud rate: 9600 baud 00 indicates data format is Engineering Units,checksum is disabled 4 Read Set Status Command Description: Read configuration for a specified WJ31 module. Command Format: $2(cr) Parameter: $ delimiter character module address, (range 00-FF) represents the 2-character hexadecimal 2 indicates read set state command Response:!TTCCFF(cr) command is valid?(cr) command is invalid or illegal operation Parameter:! delimiter character TT represents input module address Type Code CC Baud rate code, Table 3 FF Table 4 Example: command $302(cr) response!300f0600(cr)! delimiter character 30 indicates WJ31 module address is 30H 00 indicates input type code 06 represents that baud rate is 9600 baud 00 represents that data format is Engineering Units, disable checksum 5 Offset Calibration Command Description: Calibrates an analog output module ZERO offset errors Command Format: $1N(cr) Parameter: $ delimiter character module address, (range 00-FF) represents the 2-character hexadecimal 1 represents offset calibration command N channel code 0~1 Response:! (cr) command is valid Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 7 of 12

?(cr) command is invalid or Illegal operation! delimiter character which indicates a valid command.? delimiter character which indicates a invalid command. represents input module address Signal Isolators & Conditioners Products have been calibrated, user can use them directly. After calibrating offset command, then calibrate gain errors. In the calibration, analog output modules need to be calibrated channel connected to the multimeter to monitor the output signal, through the first command set command to set the analog output, regulated to multimeter inside shows the value of the output signal is zero, and then enter the calibration offset command. See the specific calibration methods calibrate the module sections. Example: command $0110(cr) response!01 (cr) Calibrate channel 0 offset at address 01H module. 6 Gain Calibration Command Description: Calibrate module channel N full gain of the output value Command Format: $0N(cr) Parameter: $ delimiter character module address, (range 00-FF) represents the 2-character hexadecimal 0 represents gain calibration command N channel code 0~1 Response:!(cr) command is valid?(cr) command is invalid or illegal operation Parameter:! delimiter character which indicates a valid command.? delimiter character which indicates a invalid command. represents input module address Products have been calibrated, user can use them directly. After calibrating offset command, then calibrate gain errors. When the calibration, the analog output module is required to connect to the multi-meter monitored output signal On been calibrated channel, through the command set command to set the analog output, adjusted to the output signal is full- scale, displays in the multi-meter, and then enter calibration gain command. The specific calibration method, see calibration Module chapter. Example: command $0100(cr) Response!01 (cr) Calibrate channel 0 at address 01H module. 7 Read Module Name Command Description: Read a analog output module name Command Format: $M(cr) Parameter: $ delimiter character module address, (range 00-FF) represents the 2-character hexadecimal M read module name command Response:!(Module Name)(cr) command is valid?(cr) command is invalid or illegal operation Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 8 of 12

Parameter:! delimiter character which indicates a valid command.? delimiter character which indicates a invalid command. represents input module address (Module Name) WJ21,WJ31 or WJ71 or other module name Signal Isolators & Conditioners Example: command $08M(cr) Response!08WJ31 (cr) At address 08H module is WJ31 8 Channel N Analog Output Value Read-Back Command Description: Analog output module channel N output value read-back Command Format: $DN(cr) Parameter: $ delimiter character module address, (range 00-FF) represents the 2-character hexadecimal D analog output value read-back command N channel code 0~1 Response:!(Data)(cr) command is valid?(cr) command is invalid or illegal operation Parameter:! delimiter character represents input module address(range 00-FF) (Data) read-back channel N analog output data. Data format may be engineering units, the percentage of FSR, Hexadecimal complement. Detailed description see command 3. (cr) terminating character, carriage return (0DH) Example: command $01D0 (cr) Response!01+12.000 (cr) At address 01H, module channel 0 current output value is +12.000mA (Data format is engineering units) 9 Set Communication Protocol Command Description: Set the module communication protocol to characters protocol or Modbus RTU protocol. Command Format: $PV(cr) Parameter: $ delimiter character P module address, (range 00-FF) represents the 2-character hexadecimal set communication protocol command V protocol code: 0 or 1. Change to hexadecimal is 30H or 31H. 0:characters protocol 1:Modbus RTU protocol Response:!(cr) command is valid?(cr) command is invalid or illegal operation Parameter:! delimiter character which indicates a valid command.? delimiter character which indicates a invalid command. represents output module address Set command protocol must be effective by default. Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 9 of 12

Example 1: command $00P1(cr) response!00 (cr) Setting the communication protocol is Modbus RTU protocol. Example 2: command $00P0(cr) response!00 (cr) Setting the communication protocol is characters protocol. Output Range and Data Format: WJ31 uses three data formats: 00:Engineering Units 01:% of FSR 10:Twos complement hexadecimal Input Range Data Format Max. Min. Engineering Units +20.000 +04.000 A4: 4-20mA % of FSR +100.00 +020.00 Twos complement hexadecimal FFF 333 Engineering Units +20.000 ±00.000 A3: 0-20mA % of FSR +100.00 ±000.00 Engineering Units +5.0000 ±0.0000 U1: 0-5V % of FSR +100.00 ±000.00 Engineering Units +10.000 ±00.000 U2:0-10V % of FSR +100.00 ±000.00 Engineering Units +5.0000-5.0000 U5: 0-±5V % of FSR +100.00-100.00 Engineering Units +10.000-10.000 U6: 0-±10V % of FSR +100.00-100.00 Engineering Units +20.000-20.000 A7: 0-±20mA % of FSR +100.00-100.00 Engineering Units +100.00 ±000.00 U8/A8: user-defined % of FSR +100.00 ±000.00 Table 4 Output Range and Data Format Example: 1. Output Range is A4:4-20mA, setting output is 4mA: Engineering Units user command #010+04.000(cr) Percent of FSR user command #010+020.00(cr) Twos complement user command #010333(cr) 2. Output Range is U1:0-5V, setting output is 3V: Engineering Units user command #010+3.0000(cr) Percent of FSR user command #010+060.00(cr) Twos complement user command #010999(cr) Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 10 of 12

Module Calibration: We have calibrated the module, the user can use directly. You can also use the product calibration function to re-calibrate the module. During calibration, the module needs using a precision multi-meter to monitor the output value. In order to improve calibration accuracy, it is recommended to calibrate using the following equipment: 1. A five and a half or more high-precision voltage / current measuring instruments to monitor the accuracy of the output signal Calibration: 1. Select to need been calibrated output channel, in accordance with the module output scope connects to the corresponding voltage or current measuring instruments. 2. Set output zero signal, usually is 0mA, 4mA or 0V. Set the analog output by the first command of command sets, adjusted to the output signal is zero value which the measuring instruments display. 3. Until the signal stabilized, send the offset calibration $ 1N command to WJ31 module.(n: channel code 0 or 1) 4. Set output full- scale signal. Set the analog output by the first command of command sets, adjusted to the output signal is full- scale value which the measuring instruments display. 5. Until the signal stabilized, send the offset calibration $ 0N command to WJ31 module.(n: channel code 0 or 1) 6. Finished Modbus RTU communication protocol: Module default protocol is character communications protocol. If you need to set the module to Modbus RTU protocol, please follow these settings: 1. Short connect INIT pin (pin 3) and GND pin (pin 6). 2. Connect the power cord and the communication interface cable. 3. Turn on the power, the module enters the default state automatically, address 00, baud rate 9600. 4. Wait 1 minute, module is initialization. 5. Send the command $00P1(cr), check the response, if is!00 (cr), set successfully. 6. Turn off the power, disconnect the INIT and GND connections. 7. The module has been set to the Modbus RTU protocol mode successfully. Register Description: Address 4X(PLC) Address(PC,DCS) Data Property Data Explanation channel 0 analog output 40001 0000 Out0(0x0000-0x0FFF) read/write value channel 1 analog output 40002 0001 Out1(0x0000-0x0FFF) read/write value channel 0 analog output 40003 0002 Sout0 (0x0000-0x0FFF) read/write value after power channel 1 analog output 40004 0003 Sout1 (0x0000-0x0FFF) read/write value after power Table 5 Modbus RTU register description Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 11 of 12

Size(unit:mm) Standard DIN35 Rail Warranty Two years (but violate operating rules and requirements to create damage, clients need pay maintenance costs) Copyright Copyright 2011 Shenzhen WAYJUN Industrial Automation Specifications subject to change without notice. Brand In this manual, mentioned other trademarks and copyright belongs to their respective owners. Shenzhen WAYJUN Industrial Automation E-mail:sales@wayjun.net www.wayjun.net Page 12 of 12