USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

Similar documents
USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

An ISO-9001 Certified Company

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL KiloModem II AC Powered, High-Speed X.21 Short-Range Modem

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

USER MANUAL. MODEL 1090 High Speed Synchronous Short Range Modem. Dear Valued Customer,

USER MANUAL MODEL 222N9. Ultra-miniature RS-232 (EIA-574) to RS-422 Interface Converter

USER MANUAL MODEL 1018RC. Powered High Speed Short Range Modem: Rack Mount Card

USER MANUAL. MODEL 1082 and 1082/144 idsl Modem with V.35 or X.21 Interface. An ISO-9001 Certified Company

USER MANUAL MODEL User Network Access Bridge. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 503P & 503PC. Parallel Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL CopperLink Ethernet Extender SALES OFFICE (301) TECHNICAL SUPPORT (301)

ME500A BLACK BOX SPECIFICATIONS: BOTTOM OF UNIT INTRODUCTION: CONFIGURATION: Async Sync Industrial Line Driver PWR TX RX RTS CD. DB25 Female Conn.

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

USER MANUAL MODEL 1010RC. Miniature Short Range Modem with Transformer Isolation: Rack Mount Card

USER MANUAL MODELS 2156 & CopperLink Ethernet Extenders SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 515 DB-15 Surge Protector

ME758C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: DB25 RJ45 CONN. INTERFACE MODULE (REAR CARD)

USER MANUAL. MODEL 2500 Series. Models 2500, 2510, 2520 All-Rate CSU/DSU SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. TS Series (Model 52X) Terminal Strip Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 570-R8/570-R R8/580-R Base-T (CAT-5) Surge Protectors

USER MANUAL MODEL 536S Token Ring (STP) Surge Protector. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Miniature Asynchronous 4-Wire High Speed Modems

USER MANUAL. MODEL 56X Series 564, 566, 568, 562. Hub Surge Protectors

DB9 Microdriver CUSTOMER SUPPORT INFORMATION JULY 1994 ME792A ME793A ME794A

USER MANUAL MODEL 571/ Base-T (CAT-5) Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

XC300 VDSL Network Extender Owners Manual

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 1089 C and D HDSL Modem with V.35 or X.21 Interface

Enclosure TS-530 User Manual

Conitel ASYNC Adapter

USER MANUAL. MODEL 1082/I and 1082/144/I idsl Modem with 10Base- T Interface. An ISO-9001 Certified Company

USER MANUAL MODEL CopperLINK High Speed Ethernet Extenders

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

DATA CONNECT ENTERPRISE

Instruction Guide. Two Port ISA Serial Card ISA2S550. The Professionals Source For Hard-to-Find Computer Parts

SPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

Chapter 2. Installing the Chapter 2. Contents

Enhanced Mini-Chansim Model VCS-232

USER MANUAL MODEL 1095

USER MANUAL MODEL 1089/I 10BaseT HDSL Rocket

USER MANUAL MODEL IM 1/I. Ethernet Bridge Module. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

SCADA Point-to-Point Multiplexer

F280XD Fiber-Optic RS-232 Modem Technical Manual

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

COMM+16.PCIe User Manual Part Number 7161e

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

M82xxD Fiber Optic RS-232 MicroModem Technical Manual

ASYNC/MULTIDROP DB-25, DB-9. LOW SPEED UNITS Basic Multipoint Long Range & Multipoint ASYNC/SYNC

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

USER MANUAL. Model 2070 Series. V.24/X.21/V.35 to G.703 Interface Converter

Interface Converter. Installation Manual IC485S IC485SGB IC485SEU. RS-232 to RS-485/422 Serial Interface Converter

IMS-9000 Intelligent Modem Switch USER S MANUAL. Document Part #: RDC-HDWIMS9K100

Xtreme/104. PC/104 Serial Communications. User Manual

Boca s Family of Ethernet Products

RS-232/RS-422 Optical Isolator

NT1B-300 Rack Installation Instructions

F271XA Fiber-Optic Telephone Modem Technical Manual

DSU 5600 Data Service Unit USER MANUAL

USER MANUAL. MODEL 1095RC NetLink mdsl Multi-Rate Symmetric DSL Rack Mount Modem Card

COMM+8.LPCI Users Manual Part Number 7803

ZM24x Quick-Connect Industrial Modem. User s Manual

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

DATA CONNECT ENTERPRISE

fiber optic gateway control box

Plus-X 300. Installation and Operation Manual

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

The Tri-State Box User s Manual

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Optical Multiplexer. Quick Start Guide

F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM


SeaLINK+8/USB. Sealevel Systems, Inc P.O. Box 830 Liberty, SC USA. Phone: (864) FAX: (864)

SeaLINK+16.VC User Manual Part Number 2167

Multi-Port Controller

Miniature Asynchronous Modems

Transcription:

USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007

1.0 WARRANTY INFORMATION Patton Electronics warrants all Model 1018 components to be free from defects, and will at our option repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user. 1.1 RADIO AND TV INTERFERENCE The Model 1018 generates and uses radio frequency energy, and if not installed and used properly that is, in strict accordance with the manufacturer's instructions may cause interference to radio and television reception. The Model 1018 has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 1018 does cause interference to radio or television reception, which can be determined by disconnecting the unit, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches). 1.2 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at (301) 975-1007. Packages received without an RMA number will not be accepted. Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1018. Technical Service hours: 8AM to 5PM EST, Monday through Friday. 1 2.0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007. 2.1 FEATURES Switch-selectable carrier control Asynchronous operation Data rates of 1.2, 2.4, 4.8, 9.6, 19.2, 28.8, 38.4 & 57.6 Kbps Flow control (RTS/CTS) Session control (DTR/DCD) Distances to 2.4 miles Point-to-point operation V.54 loopback tests and V.52 compliant BER tests Five easy-to-read LED indicators AC powered Transformer isolation Silicon Avalanche Diode surge protection 2.2 DESCRIPTION The Patton Model 1018 high speed short range modem passes two session control signals (DTR/DCD), as well as two channelindependent flow control signals (RTS/CTS). This capability makes the Model 1018 suitable for SLIP (Serial Line Internet Protocol) and PPP (Point-to-Point Protocol) applications, as well as other serial applications requiring extra controls. The Model 1018 supports asynchronous data rates to 57.6 Kbps and distances to 2.4 miles over two twisted pair. Diagnostics include V.54 loopback tests, a built-in V.52 BER test generator, and tri-state LED indicators. Communication is protected from transient surges by built-in surge protectors, and from ground loops by 1500V RMS isolation transformers. The Model 1018 s miniature size (3.55 x 2.10 x 0.78 ) allows the unit to plug directly into the RS-232 port of a host, terminal server, PC or other device. Power is supplied to the Model 1018 by a wall-mount AC transformer. Configuration is facilitated by two sets of externally accessible DIP switches, so there is no need to open the case to set switches. The Patton Model 1018 made in the USA. 2

3.0 CONFIGURATION The Model 1018 provides sixteen configuration switches, which allow selection of data rates, clocking methods, V.54 test modes, and extended signalling rates. This section describes switch locations and explains all possible switch configurations. 3.2 OPENING THE CASE Open the unit by gently inserting a screwdriver into the special pry slot on the plastic case (below). You don't have to worry about breaking the plastic. 3.1 CONFIGURATION SWITCHES The Model 1018 s unique set of sixteen internal DIP switches allows configuration to an extremely wide range of applications. These switches are grouped into two eight-switch sets and are located on the inside of the unit (Figure 1). For instructions on opening the Model 1018 case, see Section 3.2. 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 OFF OFF SW1 SW2 3.3 SWITCH SETTINGS Figure 1. The inside of the Model 1018 All possible settings for the Model 1018 s configuration switches are presented in the summary table and descriptions below. If you have additional questions regarding configuration, contact Patton Technical Support at (301) 975-1000. Figure 2 shows the orientation of the switches, including the ON/OFF positions. 1 2 3 4 5 6 7 8 ON SWITCH SET SW1 The configuration switches on switch set SW1 set analog loopback, digital loopback and V.54 enable/disable. The default settings are summarized in Figure 3. OFF DHS-8 OFF Figure 2. Close up of configuration switches 3 4

S1-1: DTE Initiation of Local Analog Loopback Test The setting for switch S1-1 determines whether or not the Model 1018 s local analog loopback test can be initiated by raising pin 18 on the DTE. S1-1 Setting On Pin 18 Initiation Enabled Off Pin 18 Initiation Disabled S1-2: DTE Initiation of Remote Digital Loopback Test The setting for switch S1-2 determines whether or not the Model 1018 s remote digital test can be initiated by raising pin 21 on the DTE. S1-2 Setting On Pin 21 Initiation enabled Off Pin 21 Initiation Disabled S1-3: Not Used S1-4: Microprocessor Reset S1 SUMMARY TABLE Position Function Factory Default S1-1 DTE Control of LAL Off Disabled S1-2 DTE Control of RDL Off Disabled S1-3 Not Used Off N/A S1-4 Microprocessor Reset Off Normal S1-5 Data Rate On } S1-6 Data Rate On 57.6 Kbps S1-7 Data Rate On S1-8 V.52/V.54 Tests Off Enabled Figure 3. Summary of DIP switch default settings for set S1 Switch S1-4 may be used to reset the microprocessor and associated circuitry. The switch should remain in the OFF position for normal operation. S1-4 Setting On Reset microprocessor Off Normal operation 5 S1-5 through S1-7: DTE Data Rate Setting Switches S1-5 through S1-7 are set in combination to determine the asynchronous DTE data rate for the Model 1018. S1-5 S1-6 S1-7 Setting Off Off Off 1.2 Kbps On Off Off 2.4 Kbps Off Off On 4.8 Kbps On Off On 9.6 Kbps Off On Off 19.2 Kbps On On Off 28.8 Kbps Off On On 38.4 Kbps On On On 57.6 Kbps S1-8: V.54 Enable/Disable The setting for switch S1-8 determines whether or not the Model 1018 s V.54 circuits are enabled. S1-8 Setting On V.54 Test Functions Disabled Off V.54 Test Functions Enabled SWITCH SET S2 The configuration switches on switch set S2 set data rate, clock source, carrier control and RTS/CTS delay. The default settings are summarized in Figure 4. S2 SUMMARY TABLE Position Function Factory Default S2-1 Not Used Off } S2-2 Not Used Off N/A S2-3 Not Used Off S2-4 Clock Source On } Internal S2-5 Clock Source On S2-6 Carrier Control On DTR Controlled S2-7 RTS/CTS Delay Off S2-8 RTS/CTS Delay Off Figure 4. Summary of DIP switch default settings for S2 6 } No Delay

S2-4 and S2-5: Clock Source Switches S2-4 and S2-5 are set in combination to determine the synchronous link clock source for the Model 1018. (Note: Although the Model 1018 supports only asynchronous DTE communication, the link between two Model 1018s is actually synchronous.) The Model 1018 may be set for either internal clock or receive recover clock. S2-4 S2-5 Setting On On Internal Transmit Clock Off On Receive Recover Clock S2-6: Carrier Control Method The setting for switch S2-6 determines whether the carrier is constantly on or controlled by DTR. This setting allows for operation in switched carrier, multipoint and/or hardware handshaking applications. S2-6 Setting Off Constantly On On Controlled by DTR S2-7 and S2-8: RTS/CTS Delay The combined settings for switches S2-7 and S2-8 determine the amount of delay between the time the Model 1018 sees RTS and when it sends CTS. Currently, the Model 1018 does not have optional delay settings. No Delay is defined as between 500 nsec and 1 msec. The switches should remain in the OFF position. S2-7 S2-8 Setting Off Off No Delay No Other Valid Settings 4.0 INSTALLATION Once the Model 1018 is properly configured, it is ready to connect to your system. This section tells you how to properly connect the Model 1018 to the twisted pair and RS-232 interfaces. 4.1 CONNECTION TO THE TWISTED PAIR INTERFACE The Model 1018 supports communication between two RS-232 devices at distances to 2.4 miles and data rates to 57.6 Kbps. Here are the two essential requirements for installing the Model 1018: 1. These units work in pairs. Therefore, you must have one Model 1018 (or a compatible model) at each end of a two twisted pair interface. 2. To function properly, the Model 1018 needs two twisted pairs of metallic wire. These twisted pairs must be unconditioned, dry, metallic wire, between 19 and 26 AWG (the higher number gauges may limit distance somewhat). Standard dial-up telephone circuits, or leased circuits that run through signal equalization equipment, or standard, flat modular telephone type cable, are not acceptable. For your convenience, the Model 1018 is available with two different twisted pair interfaces: RJ-11 jack and RJ-45 jack. 4.1.1 TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45 The RJ-11 and RJ-45 connectors on the Model 1018's twisted pair interface are pre-wired for a standard TELCO wiring environment (see Figure 5). The signal/pin relationships are shown on the table on the following page: 1 2 3 4 5 6 1 2 3 4 5 6 7 8 Figure 5. Standard AT&T color codes 7 8

RJ-11 SIGNAL RJ-45 SIGNAL 1...GND 1...N/C 2...RCV 2...GND 3...XMT 3...RCV 4...XMT 4...XMT 5...RCV 5...XMT 6...GND 6...RCV 7...GND 8...N/C Connection to ground is optional When connecting two Model 1018s, it is necessary to use a twisted pair crossover cable. The diagram below shows how a crossover cable should be constructed for an environment where both Model 1018s use a 6-wire RJ-11 connector. Similar logic should be followed when using RJ-45 connectors or a combination of the two. SIGNAL PIN# PIN# SIGNAL GND 1................. 6 GND RCV 2................. 4 XMT XMT 3................. 5 RCV XMT 4................. 2 RCV RCV 5................. 3 XMT GND 6................. 1 GND Connection to ground is optional Standard color codes yours may be different If you must use a cable to connect the Model 1018 to the DTE port, make sure it is a straight through cable of the shortest possible length we recommend 6 feet or less. 4.2.2 CONNECTION TO AN RS-232 DCE DEVICE Since the Model 1018 is wired as a DCE, you cannot connect it directly to another DCE such as a modem, multiplexer or printer. If you need to connect the Model 1018 to another RS-232 DCE device, you must use a null modem cable wired according to diagram below. We recommend a cable of the shortest possible length, preferably 6 feet or less. Connection to Model 1018 DB-25 Pin No. Connection to DCE Device DB-25 Pin No. 1...1 2...3 3...2 4...8 8...4 6...20 20...6 17...24 24...17 7...7 Note: When connected to another DCE device, the Model 1018 should be configured for external clock (see Section 3.3). 4.2 CONNECTION TO THE RS-232 INTERFACE Once you have connected the twisted pair wires correctly, simply plug the Model 1018 directly into the DB-25 port of the RS-232 device. After doing so, remember to insert and tighten the two captive connector screws. 4.2.1 CONNECTION TO A DTE DEVICE The Model 1018 is wired as a DCE, and therefore wants to plug into a DTE such as a terminal, PC or host. A direct connection to the RS-232 DTE port is most desirable. (continued) 9 10

5.0 OPERATION Once the Model 1018 is properly configured and installed, it should operate transparently as if it were a standard cable connection. Section 5.0 describes reading the LED status monitors, powering-up and using the built-in V.52 and V.54 test modes. The Model 1018 is powered by a 7.5V DC external wall mount transformer. To power up the unit, connect the power supply cord to the power jack on the rear of the Model 1018 and plug the power adapter into the wall. There is no ON/OFF switch. 5.1 FRONT PANEL SWITCHES During normal operation, both front panel switches should be in the normal center position. To operate a test mode, see Section 5.3. 5.2 LED STATUS MONITORS The Model 1018 features five front panel LEDs that monitor transmit data, carrier detect, two test modes and power. Figure 6 shows the front panel location of each LED. Following Figure 6 is a description of each LED s function. PWR BERT LOOP 511/E RDL NORMAL 511 LAL TD CD 5.3 TEST MODES The Model 1018 offers two V.54 test modes to evaluate the condition of the modems and the communication link. These tests can be activated physically from the front panel, or via the interface. Note: V.54 test modes on the Model 1018 are available for point-to-point applications only. 5.3.1 Local Analog Loopback (LAL) The Local Analog Loopback (LAL) test checks the operation of the local Model 1018, and is performed separately on each unit. Any data sent to the local Model 1018 in this test mode will be echoed (returned) back to the user device. For example, characters typed on the keyboard of a terminal will appear on the terminal screen. To perform a LAL test, follow these steps: A. Activate LAL. This may be done in one of two ways: First, by moving the front panel toggle switch DOWN to LAL. Second, by raising pin 18 on the interface. (Note: Make sure DIP switch SW1-8 is OFF). Once LAL is activated, the Model 1018 transmit output is connected to its own receiver. The test LED should be lit. B. Verify that the data terminal equipment is operating properly and can be used for a test. If a fault is indicated, call a technician or replace the unit. C. Perform a BER (bit error rate) test on each unit. If the BER test equipment indicates no faults, but the data terminal indicates a fault, follow the manufacturer s checkout procedures for the data terminal. Also, check the interface cable between the terminal and the Model 1018. Figure 6. Model 1018 s LED indicators and test switches PWR = Glows green when the Model 1018 is powered up. TD = Glows red for a space on transmit data. CD = Glows red for high on carrier detect. BERT = Glows red when bit errors occur in test mode (511 pattern); Lights when 511/E test pattern has been selected. LOOP = Glows red when the Model 1018 is in remote digital loopback or local analog loopback mode. 11 5.3.2 Remote Digital Loopback (RDL) The Remote Digital Loopback (RDL) test checks the performance of both the local and remote Model 1018s, and the communication link between them. Any characters sent to the remote Model 1018 in this test mode will be returned back to the originating device. For example, characters typed on the keyboard of the local terminal will appear on the local terminal screen after having been passed to the remote Model 1018 and looped back. To perform an RDL test, follow these steps: A. Activate RDL. This may be done in two ways: first, by moving the front panel toggle switch UP to RDL. Second, by raising pin 21 on the interface. (Note: Make sure SW1-8 is OFF). 12

B. Perform a BER (bit error rate) test on the system. C. If the BER test equipment indicates a fault, and the Local Analog Loopback test was successful for both Model 1018s, you may have a problem with the twisted pair line between the modems. You should then check the twisted pair line for proper connections and continuity. 5.3.3 Using the V.52 BER Test Independently The V.52 BER test can be used independently of the V.54 loopback tests. This requires two operators: one to initiate and monitor the test at the local Model 1018, and one at the remote Model 1018. To use the V.52 BER test by itself, both operators should simultaneously follow these steps: 1. Locate the 511/511E toggle switch on the front panel of the 1018 and move it DOWN. This activates the V.52 BER test mode and transmits a 511 test pattern to the other unit. If any errors are present, the receiving modem s red Error LED will blink sporadically. Note: For this test to function, the 511 switch on both Model 1018s must be on. 2. If the test indicates no errors are present, move the V.52 toggle switch UP, activating the 511/E test with errors present. If the test is working properly, the receiving modem's red Error LED will glow. A successful 511/E test will confirm that the link is in place, and that the Model 1018 s built-in 511 generator and detector are working properly. 5.4 POWER-DOWN Turn off the Model 1018 by unplugging the AC power adapter from the wall. There is no power switch on the Model 1018. APPENDIX A SPECIFICATIONS DTE Transmission Format: Asynchronous Link Transmission Format: Synchronous Transmission Line: Unconditioned twisted pair 19-26 AWG Link Clocking: Internal Distance: 2.4 miles Interfaces: EIA RS-232 / CCITT V.24 DTE Data Rates: 1.2, 2.4, 4.8, 9.6, 19.2, 28.8, 38.4 and 57.6 Kbps (switch selectable) Isolation: Minimum 1500 V RMS via isolation transformers Surge Protection: 600W power dissipation at 1 ms and response time of 1 ps Carrier: Constantly on or Controlled by DTR Connectors: DB-25 female or male on RS-232 side; RJ-11 or RJ-45 on line side Power Supply: 7.5V DC wall mount transformer Temperature Range: 0-60 C (32-140 F) Altitude: 0-15,000 feet Humidity: Up to 95% non-condensing Dimensions: 3.55 x 2.1 x.80 Weight: 2 oz. 13 14

APPENDIX B PIN CONFIGURATIONS APPENDIX C BLOCK DIAGRAM DIRECTION RS-232 PIN-OUT REFERENCE (DB-25) DIRECTION To Model 1018 Local Analog Loopback - 18 To Model 1018 Data Term. Ready (DTR) - 20 From Model 1018 Remote Digital Loopback - 21 1 - (FG) Frame Ground Common 2 - (TD) Transmit Data To Model 1018 3 - (RD) Receive Data From Model 1018 4 - (RTS) Request to Send To Model 1018 5 - (CTS) Clear to Send From Model 1018 6 - (DSR) Data Set Ready From Model 1018 7 - (SG) Signal Ground Common 8 - (CD) Carrier Detect From Model 1018 From Model 1018 Test Mode - 25 15 16