HC900 Controller. Controller CPU and Scanner Module Installation and Replacement

Similar documents
ControlEdge HC900 Controller

Series 3700 Screw Terminal Assemblies Installation Instructions

HC900 Remote Termination Panel (RTP) For Relay Outputs

Replacing the Power Supply

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

Power Supply and Fan Module Installation

Removing and Installing the ISA and the ISM

Oracle <Insert Picture Here>

P/N Operation & Installation Manual Serial Control Transfer Switch Model TM-STS

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

Installing the PSU for the S50 and S50N

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Certificate of Compliance

Installation Instructions

VP-1231-CE7 Quick Start

EMC 10/4 "CE" Mechanical Upgrade Procedure

7403-K131/132/133/K138. Memory Modules. Kit Instructions. Issue C

Maintaining the ERX System

MacBook Pro 13" Unibody Mid 2010 SSD Dual Drive Installation

HC900 Controller Redundancy Overview & System Operation

Installing and Managing the Switch

Maintaining E-Series Routers

ControlEdge HC900 Process & Safety Controller User and Installation Manual

Installing Sentor. Hardware Installation

Introduction. Overview

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

EMC 10T "CE" Mechanical Upgrade Procedure

INSTALLATION INSTRUCTIONS

SCSI Cable Installation Instructions

PSA200 User s Manual

Sony Vaio VPCCW21FX System Board Removal

SYSTEM 8/10 Plus PROJECTOR COMMUNICATIONS KIT ATTENTION! PLEASE READ THIS DOCUMENT FOR IMPORTANT INSTALLATION INSTRUCTIONS

Cardfiles (MicroLok II Applications)

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Installing MacBook Pro 15" Unibody Mid 2009 Dual Hard Drive

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

Installing the Cisco SFS 3504 Server Switch

PACSystems* RX3i Genius* Communications Gateway, IC695GCG001. Quick Start Guide, GFK-2891C August 2016

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

MPP1700 User s Manual

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

XCM8800 PSU Cover. Installation Guide. 350 East Plumeria Drive San Jose, CA USA. May v1.0

REMOTE HEAD ADAPTER INSTALLATION GUIDE

HC900 Control Station Model Numbers 900CS10-00 and 900CS15-00 Installation

PACSystems RX7i IC698CHS009/119

MPP200 User s Manual

PEM Faults and Blower Failures

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction

Instructions to printer DO NOT PRINT THIS PAGE

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

X500 EXPANSION UNIT QUICK START GUIDE. Rugged Mobile Computing Solutions

PLC Racks IC697CHS782/783

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

HC900 Controller Redundancy Overview & System Operation

Maintaining the ERX System

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Appendix G. CJ1W-CIF11 RS-422A Converter

VP101-BT Installation Guide

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

Use flat head screws for the out side of chassis and pan head screw for inside of chassis.

Power Supply, 17-inch

Allen-Bradley Drives

Removal / Replacement Manual

IBM Systems. Quick start guide for IBM System p5 505 ( )

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

Adding or Replacing a PCI Card

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

Replacing the Hardware Configuration Option EPROM on the 1822

MacBook Unibody Model A1278 SSD Dual Drive

Customer Replacement Procedure

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.

Allen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon

Rear Consumer LCD Hinge Assembly Large Displays

PCIE FIVE SLOT EXPANSION SYSTEM USER S MANUAL

HP EVA4400 M6412 drive enclosure

EMAX II MEMORY EXPANSION

SCXI SHIELDED MULTI-CHASSIS CABLE ADAPTER

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

Removal and Replacement of the Serrano and Corsica Boards

(Cat. No A1B, -A2B, -A3B, -A3B1, -A4B Series B) Installation Data. Make sure you have these items:

Installation and Maintenance

^2UMAC-CPCIAccessory Cx Family

Dell Networking C9010 Getting Started Guide

Installation Instructions

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

HP ProLiant DL165 G7 Server

PowerFlex 700S Phase II Drives DriveLogix Option Card Battery Extension Cable

Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide

Rack Installation Instructions

A+ Guide to Managing and Maintaining Your PC. Electricity and Power Supplies

Integrated Headend Unit (IHU) Quick Installation Sheet

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Perle MCR200 Installation Guide

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Transcription:

HC900 Controller and Scanner Module Installation and Replacement Scanner 1 Scanner 2 (for redundant controller) 900C51 - (current revision number) 900C52 - (current revision number) 900C31 - (current revision number) 900C32 - (current revision number) 900C71 - (current revision number) 900C72 - (current revision number) 900C53 - (current revision number) 900C73R - (current revision number) Document Number Form: 51-52-33-126 Effective Date: 2/2007 Supersedes: 6/2006 Summary Enclosed is a new, Scanner 1, or Scanner 2 module for your HC900 Controller. Use the following procedures to install or replace a module. Table 1 and 3 Scanner 1 Table 2 and 3 Scanner 2 Table 4 WARNING Never attempt to add or remove the Controller or Scanner modules from the controller rack with power applied. See the HC900 Controller Installation and User s Guide for more information. HC900 Hardware Controller Rack Assembly 1. Rack, available in 4-8-, or 12-slot versions 2. Power Supply 3. or Scanner 1 Module (for Scanner 2, see Figure 4) 4. Grounding bars (for I/O wiring; optional) 5. Input/Output modules 6. I/O Terminal Blocks RIUP Figure 1 2/07 and Scanner Module Kit # 51-52-33-126 1

Contents Each and Scanner module is supplied in a shipping container and static protective shipping bag. For protection, leave the modules in their shipping containers until ready for installation. Each container has a label identifying the contents. C30 Controller C50 Controller C70 Controller Scanner 1 Port Scanner 2 Port Installation Guidelines The and Scanner modules may only be inserted into a dedicated slot location in the rack. The modules are labeled by name at top front; for example, C30, C50, C70, Scanner 1 Port, Scanner 2 Port. Most of the components in an I/O expansion rack are identical to those used in the Controller Rack. The is installed in the controller rack (Figure 1, item 3) whereas the Scanner 1 or Scanner 2 is installed in the I/O expansion rack (Figure 2). 2 and Scanner Module Kit # 51-52-33-126 2/07

Installation Procedure Follow the procedure in Table 1 to install a module in a controller rack. Table 1 Installation 1 Orient the controller rack to have the open side of the enclosure facing forward with the power supply module located on the left and I/O module slots on the right (See figure 1). 2 Remove the module from its shipping container. 3 On the new CPU set/verify serial port switch settings. S1 (SW1) is shipped set to RS-232. S2 (SW2) is shipped set to RS-485. Only port S2 (SW2) can be used with a Honeywell operator interface model 559 or 1042). For this, the port must be RS-485, ELN protocol. Only one port may be a Modbus Master. It can be assigned to either port. Modbus Master can be used on either RS-232 or RS-485. A small slotted screwdriver or paperclip works well; avoid using pencils because their residue can damage the switch. RS-232 RS-485 RS-485 Port disabled terminated unterminated 4 Insert the module into the dedicated slot location in the rack adjacent to the power supply. Orient the module with module name at top. Align the module printed circuit board with the card guide slots in the chassis. Press the CPU module into the slot until the rear connector engages the mating connector of the rack backplane. (See figure 2.) Figure 2 5 Secure the module top and bottom with the captive mounting screws. 6 Do not install the battery at this time. See instructions in the Controller Installation and User s Guide (document #51-52-25-107) for additional setup information and battery installation. 2/07 and Scanner Module Kit # 51-52-33-126 3

Follow the procedure in Table 2 to install a Scanner 1 module in an expansion I/O rack. Table 2 Scanner 1 Installation 1 Orient the I/O expansion rack to have the open side of the enclosure facing forward with the power supply module located on the left and I/O module slots on the right (See figure 1). 2 Remove the Scanner 1 module from the shipping container. Set scanner address for the I/O rack using the DIP switches on. A small slotted screwdriver or paperclip works well; avoid using pencils since the residue can damage the switch. DIP switches 5, 6, 7, 8 must be OFF. Honeywell Only 1 DIP switch may be. DIP switch 1 = Scanner 1 DIP switch 2 = Scanner 2 DIP switch 3 = Scanner 3 DIP switch 4 = Scanner 4 Figure 3 Scanner 1 DIP switches 3 Insert the module into its dedicated slot location in the rack adjacent to the power supply. Orient the module with the module name at top. Align the module printed circuit board with the card guide slots in the chassis. Press the Scanner module into the slot until the rear connector engages the mating connector of the rack backplane. (See Figure 2) 4 Secure the Scanner module top and bottom with the captive mounting screws. 4 and Scanner Module Kit # 51-52-33-126 2/07

or Scanner 1 Follow the procedure in Table 3 to replace a or Scanner 1 Replacement module in an existing rack. Table 3 Controller or Scanner Module replacement 1 Before replacing the module verify a copy of the current configuration file is available and a method of loading the file is understood. See Hybrid Control Designer User s Guide or HC900 Hybrid Controller Operator Interface User s Guide. 2 Remove power from the rack. 3 Remove the screws that secure the module assembly to the rack. Note that these screws function to jack the module board assembly away from the rack. 4 Pull the assembly to remove. For modules, go to step 6. 5 Remove the Scanner 1 module from the shipping container. Set scanner address for the I/O rack using the DIP switches on. A small slotted screwdriver or paperclip works well; avoid using pencils since the residue can damage the switch. DIP switches 5, 6, 7, 8 must be OFF. Honeywell Only 1 DIP switch may be. DIP switch 1 = Scanner 1 DIP switch 2 = Scanner 2 DIP switch 3 = Scanner 3 DIP switch 4 = Scanner 4 Scanner 1 DIP switches 6 On the new CPU set/verify serial port switch settings. See Table 1 3. 7 Insert the new module into the dedicated slot location in the rack. Orient the module with module name at top. Align the module printed circuit board with the card guide slots in the chassis. Press the module into the slot until the rear connector engages the mating connector of the rack backplane. (See figure 2) 8 Secure the module top and bottom with the captive mounting screws. 9 Re-apply power to the rack. 10 See instructions in the Controller Installation and User s Guide (document #51-52-25-107) for additional setup information and battery installation. 2/07 and Scanner Module Kit # 51-52-33-126 5

Scanner 2 Overview One Scanner2 Module is installed in each I/O Rack of a redundant system. I/O ports A and B connect to CPU-A and CPU-B of the redundant C70R Controller CPUs. Maintains communications with both Lead and Reserve C70R CPU s to facilitate failover. Reads inputs from modules in rack & writes outputs to modules in rack. Required for interface to C70R redundant controllers (cannot use Scanner1 module with C70R s). RIUP Cannot be replaced under power. Cannot use with non-redundant systems. Scanner 2 Port Scanner 2 Installation The Scanner 2 module may only be inserted into a dedicated slot Guidelines location in a Remote I/O Rack. (Figure 4) PSM Power Supply #1 Power Status Module Power Supply #2 Dual Port Scanner for C70R CPU, Input/Output Modules 8 slot and 12 slot I/O Racks Figure 4 6 and Scanner Module Kit # 51-52-33-126 2/07

Scanner 2 Follow the procedure in Table 4 to install or replace a Scanner 2 Installation or module in a redundant power rack. Replacement Table 4 Scanner 2 Module installation or replacement 1 If you are installing a new Scanner 2, go to step 6. If you are replacing the Scanner 2, go to step 2. 2 Remove power from the rack containing the Scanner 2 module to be replaced. 3 Remove the screws that secure the module assembly to the rack. Note that these screws function to jack the module board assembly away from the rack. 4 Pull the Scanner 2 module to remove. 5 Remove the Scanner 2 module from the shipping container and position the scanner address DIP switches on the module for the appropriate address position (see 6). 6 Set rack address for the I/O rack using the Scanner 2 Module DIP switches on (shown at right). (Scanner Address = 1 is shown.) DIP switches 6-8 must be OFF. Only 1 DIP switch may be. DIP switch 1 = Scanner 1 DIP switch 2 = Scanner 2 DIP switch 3 = Scanner 3 DIP switch 4 = Scanner 4 DIP switch 5 = Scanner 5 A small slotted screwdriver or paperclip works well; avoid pencils. 7 Insert the new module into the dedicated slot location in the rack. Orient the module with the I/O ports on the bottom. Align the module printed circuit board with the card guide slots in the chassis. Press the Scanner 2 module into the slot until the rear connector engages the mating connector of the rack backplane. 8 Secure the new Scanner 2 module top and bottom with the captive mounting screws. 9 Re-apply power to the rack. 2/07 and Scanner Module Kit # 51-52-33-126 7