Absorbed Fractions for Multi-Region Models of the Kidneys in ICRP/ICRU Voxel Phantoms

Similar documents
Towards patient specific dosimetry in nuclear medicine associating Monte Carlo and 3D voxel based approaches

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.

ICRP Symposium on Radiological Protection Dosimetry

Construction of Voxel-type Phantom Based on Computed Tomographic Data of RANDO Phantom for the Monte Carlo Simulations

OBJECT ORIENTED DESIGN OF ANTHROPOMORPHIC PHANTOMS AND GEANT4-BASED IMPLEMENTATIONS ABSTRACT

Development and Use of Computational Anthropomorphic Phantoms for Medical Dosimetry Nina Petoussi-Henss

Anthropomorphic Phantoms

Voxel phantoms and Monte Carlo methods applied to internal and external dose calculations.

EFFECTIVE DOSE RATIOS FOR TOMOGRAPHIC AND STYLIZED MODELS FROM EXTERNAL EXPOSURE TO PHOTONS

Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code

Katja the 24 th week of virtual pregnancy for dosimetric calculations

Basics of treatment planning II

Three Dimensional Dosimetry Analyses In Radionuclide Therapy Using IDL And MCNP-based Software Tools

MODELLING RADIATION TRANSPORT IN VOXEL GEOMETRIES WITH THE MONTE CARLO CODE MCNPX

Mathematical methods and simulations tools useful in medical radiation physics

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS

Design and Fabrication of Kidney Phantoms for Internal Radiation Dosimetry Using 3D Printing Technology

Image-based Monte Carlo calculations for dosimetry

Computational Phantoms of the ICRP Reference Male and Reference Female

State of the art of voxel phantom development

DRAFT TO BE SUBMITTED TO HEALTH PHYSICS JOURNAL

Library of Mesh and NURBS female phantoms for pulmonary in vivo counting studies

IMPLEMENTATION OF SALIVARY GLANDS IN THE BODYBUILDER ANTHROPOMORPHIC PHANTOMS

84 Luo heng-ming et al Vol. 12 Under the condition of one-dimensional slab geometry the transport equation for photons reads ±()N(x; μ; ) du d N(

Dose Point Kernel calculation and modelling with nuclear medicine dosimetry purposes

Internal radionuclide dosimetry of model and patient based voxelised phantoms using the GATE toolkit

Study of scattered photons from the collimator system of Leksell Gamma Knife using the EGS4 Monte Carlo Code

FASH and MASH: Female and Male Adult human phantoms based on polygon mesh surfaces Part II: Dosimetric calculations

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43

ANALYSIS OF CT AND PET/SPECT IMAGES FOR DOSIMETRY CALCULATION

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Tomographic Anthropomorphic Models. Part IV: Organ Doses for Adults due to Idealized External Photon Exposures

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

gpmc: GPU-Based Monte Carlo Dose Calculation for Proton Radiotherapy Xun Jia 8/7/2013

GSF MALE AND FEMALE ADULT VOXEL MODELS REPRESENTING ICRP REFERENCE MAN THE PRESENT STATUS

Dosimetry Simulations with the UF-B Series Phantoms using the PENTRAN-MP Code System

Comparison of measured and Monte Carlo calculated electron beam central axis depth dose in water

Evaluation of RayXpert for shielding design of medical facilities

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Indrin Chetty Henry Ford Hospital Detroit, MI. AAPM Annual Meeting Houston 7:30-8:25 Mon 08/07/28 1/30

Deformation of mesh-type ICRP reference computational phantoms in different statures and postures for individualized dose calculations

CT vs. VolumeScope: image quality and dose comparison

Geant4-DICOM Interface-based Monte Carlo Simulation to Assess Dose Distributions inside the Human Body during X-Ray Irradiation

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Improvements in Monte Carlo simulation of large electron fields

Limitations in the PHOTON Monte Carlo gamma transport code

Mesh Human Phantoms with MCNP

ARTCOLL PACKAGE FOR GAMMA ART6000 TM ROTATING GAMMA SYSTEM EMISSION SPECTRA CALCULATION

Lecture notes: Photon Monte Carlo simulation. Alex F Bielajew. Institute for National Measurement Standards. National Research Council of Canada

Determination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation

Room scatter effects in Total Skin Electron Irradiation: Monte Carlo simulation study

Monte Carlo Simulations for In Vivo Internal Dosimetry (including phantom development)

Development of the Efficient Modeling Method with Complicated Human Geometry for Monte-Carlo Treatment Planning System

MEASUREMENTS OF AIR KERMA AS FUNCTION OF POTENTIAL IN X-RAY TUBES FOR ESTIMATES STANDARD QUANTITIES USED FOR DOSIMETRIC EVALUATION

TWENTY YEARS OF VISUAL MONTE CARLO

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

SESAME: A NEW TOOL FOR THE NUMERICAL DOSIMETRIC RECONSTRUCTION OF A RADIOLOGICAL ACCIDENT CAUSED BY AN

Monte Carlo evaluation of the dosimetric uncertainty in matched 6 MV Elekta and Varian linear accelerators

Script Script Generator. write display Classes. Parser. read. interface VUI. Generic Code Interface (OO HOWFAR, AUSGAB) EGS5

Michael Speiser, Ph.D.

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.

Development and anatomical details of Japanese adult male/female voxel models

The OpenGATE Collaboration

Application of MCNP Code in Shielding Design for Radioactive Sources

THE SIMULATION OF THE 4 MV VARIAN LINAC WITH EXPERIMENTAL VALIDATION

Handling of high resolution imaging data for usage in Monte Carlo calculations

Author's Accepted Manuscript

Computational Anthropomorphic Models of the Human Anatomy: The Path to Realistic Monte Carlo Modeling in Radiological Sciences

A CT-based Monte Carlo Dose Calculations for Proton Therapy Using a New Interface Program

4. Conclusions. 5. References

3D/4D HUMAN MODELING AND MONTE CARLO DOSE CALCULATION FOR RADIATION PROTECTION, IMAGING AND RADIOTHERAPY

Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Effects of the difference in tube voltage of the CT scanner on. dose calculation

Monte Carlo modeling of a Novalis TX Varian 6 MV with HD-120 multileaf collimator

Simulations in emission tomography using GATE

Development of a mouse computational model for MCNPx based on Digimouse images and dosimetric assays

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

Av. Professor Lineu Prestes São Paulo, SP ABSTRACT

Source Model Tuning for a 6 MV Photon Beam used in Radiotherapy

GSF Male and Female Adult Voxel Models Representing ICRP Reference Man

Suitability Study of MCNP Monte Carlo Program for Use in Medical Physics

GPU-based fast Monte Carlo simulation for radiotherapy dose calculation

Application of efficient Monte Carlo photon beam simulations to dose calculations in voxellized human phantoms

Basics of treatment planning II

SHIELDING DEPTH DETERMINATION OF COBALT PHOTON SHOWER THROUGH LEAD, ALUMINUM AND AIR USING MONTE CARLO SIMULATION

Impact of X-ray Scatter When Using CT-based Attenuation Correction in PET: A Monte Carlo Investigation

Disclosure 7/24/2014. Validation of Monte Carlo Simulations For Medical Imaging Experimental validation and the AAPM Task Group 195 Report

VIEWING MORSE-CG RADIATION TRANSPORT WITH. 3-D COLOR GRAPHICS* Abstract

Evaluation of latent variances in Monte Carlo dose calculations with Varian TrueBeam photon phase-spaces used as a particle source

Monte Carlo simulations

Investigation of photon beam output factors for conformal radiation therapy Monte Carlo simulations and measurements

Computer-assisted segmentation of CT images by statistical region merging for the production of voxel models of anatomy for CT dosimetry

Attenuation Coefficients for Layered Ceiling and Floor Shields in PET/CT Clinics

Comparison Study of Monte Carlo Simulations and Measurements of Relative Output Factors of 6 MV Photon Beam

A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Monte Carlo Treatment Planning

A Radiometry Tolerant Method for Direct 3D/2D Registration of Computed Tomography Data to X-ray Images

Transcription:

Absorbed Fractions for Multi-Region Models of the Kidneys in ICRP/ICRU Voxel Phantoms Sakae KINASE *, Masanori KIMURA, Shogo TAKAHARA and Toshimitsu HOMMA * 2-4 Shirane, Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1195, Japan Kidney dosimetry is indispensable in internal dose evaluations since the kidneys appear to represent radioactivity uptake in both diagnostic and therapeutic nuclear medicine. The Medical Internal Radiation Dose () Committee of the Society of Nuclear Medicine has presented multi-region kidney models and evaluated absorbed fractions () fraction of energy emitted in a source region which is absorbed in some target regions for regional kidney doses in the schema. However, it is needed to update the for the kidneys since the kidney models, which are stylized models, do not reflect realistic anatomy. The International Commission on Radiological Protection (ICRP) has developed reference computational models i.e. ICRP/ICRU voxel phantoms of the Reference Male and Reference Female, which have more realistic and detailed information about the kidney than the kidney models. The ICRP/ICRU kidney model consists of 3 regions for each kidney: cortex, medulla and pelvis. In the present study, the ICRP/ICRU kidney models were applied to evaluating for the kidneys. Uniformly distributed photon sources with the energy range from 10 kev to 10 MeV were assumed to be in the cortex, medulla and pelvis. The radiation transport was simulated using a Monte Carlo code. Consequently, it was found that the with the ICRP/ICRU kidney models were consistent with those with the kidney model for adult. In the case of cross-irradiation, the largest differences between the two kidney models (ICRP/ICRU and ) were found to be 3.3 for the female and 2.6 for the male in the low-energy region. The obtained in the present study would be useful for non-uniformly distributed source of photons in kidney dosimetry. Key Words: Kidney, ICRP,, voxel, AF 1. Introduction The present study is of internal dosimetry for the adult kidneys. Kidney dosimetry is important since the kidneys represent a frequent source of radioactivity uptake. Recent interest in sophisticated approaches in kidney dosimetry with incorporated radionuclides, has spurred a great deal of research into the application of computational models. The Medical Internal Radiation Dose () Committee of the Society of Nuclear Medicine has presented the stylized mathematical models of the kidneys for use in regional dose assessment and evaluated absorbed fractions () the fraction of the energy emitted by source region that is absorbed in

target region in the radiation energy range from 10 kev to 4 MeV[1]. The kidney models and the are capable of evaluating regional kidney doses not previously supported by single-region kidney models. However, the kidney models are not always appropriate in kidney dosimetry since the models represented with ellipsoids are not realistic. The International Commission on Radiological Protection (ICRP) and the International Commission on Radiation Units and Measurements (ICRU) has introduced the anatomical models of Reference Male and Reference Female ICRP/ICRU voxel phantoms[2]. The ICRP/ICRU voxel phantoms, which are based on medical image data of real people, have multi-region models of the kidneys. The purpose of the present study was to evaluate for photons in the ICRP/ICRU kidney models and to examine the relationship of between those for the ICRP/ICRU kidney models and those for the kidney model. 2. Materials and Methods 2.1. ICRP/ICRU kidney models The ICRP/ICRU adult male and female reference voxel phantoms were used in the present study. The voxel phantoms, based on computed tomographic data sets, were developed by the Helmholtz Zentrum München in collaboration with DOCAL of ICRP committee 2 and ICRU. The voxel sizes are 2.137 2.137 8.0 mm 3 for the adult male voxel phantom and 1.775 1.775 4.84 mm 3 for the adult female voxel phantom. Many organs and tissues are segmented and identified. Three regions are segmented in each kidney: cortex, medulla and pelvis. The mass of each kidney region in the voxel phantoms is shown in Table 1. The kidneys are adjusted to approximate the reference mass values with high precision. For comparison, the mass of each region for the kidney model of adult are also shown in the table. 2.2. Absorbed fractions () Absorbed fractions for photons were evaluated for the ICRP/ICRU kidney models using the Monte Carlo code, EGS4[3], in conjunction with an EGS4 user code, UCSAF[4]. In the EGS4-UCSAF code, the radiation transport of electrons, positrons and photons in the phantoms was simulated, and correlations between primary and secondary particles are included. In the present study, the sources of the photons were assumed to be mono-energetic in the energy range from 10 kev to 10 MeV and uniformly distributed in the source region. The source regions were cortex, medulla and pelvis in kidneys. Photon histories were selected to be numbers sufficient to reduce statistical uncertainties below 5%. The cutoff energies were set to 1keV for the photons and 10keV for the electrons. The Parameter Reduced Electron-Step Transport Algorithm (PRESTA) [5] to improve the electron transport in the low-energy region was used. The cross-section data for photons were taken from PHOTX[6,7] and the data for

electrons are taken from ICRU report 37[8]. 3. Results and Discussions for mono-energetic photons were evaluated by the EGS4-UCSAF code for the multi-region kidney models in the ICRP/ICRU voxel phantoms and compared with published data[1,9]. Table 2 compares self-irradiation (source=target) for photon energies of 30 kev, 100 kev and 1 MeV. The result shows that the self-irradiation for photons in the ICRP/ICRU kidney models are consistent with those for the kidney model. The self-irradiation for the multi-region kidney models are smaller than those for total kidneys single-region kidney models. It should be noted that kidney dosimetry conducted using single-region kidney models are not always accurate since the radioactivity is concentrated non-uniformly in the kidneys. Figures 1 (a)-(c) show photon for the multi-region kidney models of the ICRP/ICRU voxel phantoms in the energy range from 10 kev to 10 MeV. for the kidney model of adult are also plotted in the figures. The self-irradiation decrease with an increase in photon energy on the whole. The cross-iradiation (source target) increase up to about 20 kev and then they decrease. From a comparison with the results it can be stated that the for the ICRP/ICRU kidney models are in harmony with those for the kidney model of adult. However, there are deviations between them in the low-energy region. In the case of cross-irradiation, the largest differences between the two kidney models (ICRP/ICRU and ) were found to be 3.3 for the female and 2.6 for the male in the low-energy region. This is due to the different shape and size of the regional kidneys. Since the mean free path of the photon with low-energy is not large compared with the size of the regional kidneys, low-energy photons could not be considered pure penetrating for the dosimetry. From the standpoint of the schema, the for the kidney model of adult were validated except for those for low-energy photons and electrons. 4. Conclusions The for the multi-region kidney models of the ICRP/ICRU voxel phantoms were evaluated using Monte Carlo simulations in the photon energy range from 10 kev to 10 MeV. The obtained were compared with those for the kidney model. It was found that the for the ICRP/ICRU kidney models are consistent with those for the kidney model and that the self-irradiation for the multi-region kidney models are smaller than those for single-region kidney models. The obtained in the present study as well as those for the kidney models would be useful for non-uniformly distributed source of photons in kidney dosimetry.

Table 1 Mass of each regional kidney in the ICRP/ICRU and the models[1] Suborgan Mass (kg) ICRP/ICRU male ICRP/ICRU female [1] 2.2 1.9 2.1 7.8 6.9 7.5 1.6 1.4 1.3 Total kidney 3.1 2.8 3.0 * * including the mass of papillae (2.5 10-3 kg). Table 2 Self-irradiation absorbed fractions in ICRP/ICRU kidney models and kidney model of adult[1] for photon energies of 30 kev, 100 kev and 1 MeV Absorbed fraction Suborgan ICRP/ICRU male ICRP/ICRU female [1] Energy, 30 kev 0.25 0.24 0.226 0.19 0.18 0.167 0.11 0.11 0.102 Total kidney[9] 0.36 0.35 Energy, 100 kev 0.051 0.051 0.0495 0.036 0.033 0.0336 0.019 0.018 0.0186 Total kidney[9] 0.076 0.073 Energy, 1 MeV 0.047 0.047 0.0471 0.034 0.031 0.0328 0.018 0.017 0.0184 Total kidney[9] 0.069 0.068

(a) source=cortex 10-3 10 1 10 1 10 1 10 1 10 1 10-3 10 1 (b) source=medulla 10 1 10 1 10-3 10 1 (c) source=pelvis Figure 1. Comparison of absorbed fractions in the kidneys for the ICRP/ICRU and models in the photon energy range 10 kev 10MeV.

References [1] Bouchet, L. G., Bolch, W. E., Blanco, H. P., Wessels, B. W., Siegel, J. A., Rajon, D. A., Clairand, I. and Sgouros, G., 2003. Pamphlet No.19: Absorbed fractions and radionuclide S values for six age-dependent multiregion models of the kidneys, J. Nucl. Med. 44, 1113-1147. [2] ICRP, 2009. Adult reference computational phantoms, ICRP Publication 110 (Oxford, UK: Elsevier). [3] Nelson, W. R., Hirayama, H. and Rogers, D. W. O., 1985. The EGS4 code system, SLAC-265. [4] Kinase, S., Zankl, M., Kuwabara, J., Sato, K., Noguchi, H., Funabiki, J. and Saito, K., 2003. Evaluation of specific absorbed fractions in voxel phantoms using Monte Carlo simulation, Radiat. Prot. Dosim. 105 (1-4), 557-563. [5] Bielajew, A. F., and Kawrakow, I., 1997. The EGS4/PRESTA-ІІ electron transport algorithm: Tests of electron step-size stability, Proceedings of the XІІ th Conference on the Use of Computers in Radiotherapy 153-154 (Madison, WI:Medical Physics Publishing). [6] RSIC, 1989. DLC-136/PHOTX Photon interaction cross section library (contributed by National institute of standards and technology). [7] Sakamoto, Y., 1993. Photon cross section data PHOTX for PEGS4, KEK Proceedings 93-15, 77-82 (in Japanese). [8] ICRU, 1984. Stopping powers for electrons and positrons. ICRU Report 37 (Bethesda, MD, USA: ICRU). [9] Kinase, S., Kimura, M., Takahara, S. and Homma, T., Using ICRP/ICRU voxel models to evaluate specific absorbed fractions, Prog. Nucl. Sci. Tech. (in press).