PQR Series. Power Quality Recorders. For SINGLE, DUAL, THREE PHASE, and ENVIRONMENTAL applications.

Similar documents
Model OM-PQR1010. Page 2

PowerTronics Probe Datalogging User s Manual PowerTronics 143 Raymond Road Candia, N.H

CT-8000 S3 digital circuit breaker analyzer

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

CT-8000 S3. digital circuit breaker analyzer

INNOVOLT P1003 USER GUIDE

Flat. PITK-W025B Flat 23W LED Driver. Features. Specification Summary. Input Specifications 1 / V / 0.57A / 23W. Mechanical Outline

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Powerware 3105 UPS User s manual

Powerware 3105 UPS User s manual

RTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

Three-Phase Power Quality Analyzer PowerPad Model 3945

Advanced Test Equipment Rentals ATEC (2832)

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

Installation and Operation Back-UPS Pro 900

Model NM512. TS1 Conflict Monitor Standard 12 Channel Unit. Naztec Operations Manual. For. Published by

UPS Series. features: uninterruptible power supply. what great systems are built on.

ME6008M Batch Monitor Printer Driver Unit

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

CT-7500 S2. Advanced Test Equipment Rentals ATEC (2832) digital circuit breaker analyzer

Single Phase Systems-North American PC125/PC420 Series

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Really Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440)

VS Series 120V 600VA 300W Line-Interactive Desktop UPS, Tower, 6 Outlets

EATON 5S 850/1200/1600

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

INTRODUCTION CT87E FEATURES AND CONTROLS

EZCT S2A current transformer test set

LCD-1 CD-LCD1-01 PRODUCT OVERVIEW. Product. Description. Specifications SKU: LCD-1. 5-Button Scene Controller

Ranger PM6000. Power Quality Monitor

Version /25/2014. User Manual. PowerLine AV 500 Passthrough Mini Adapter DHP P308AV / DHP-P309AV

Flat. PIFN-C072B Flat 75W LED Driver. Features. Electrical Specifications. Input Specifications 1 / 8 18V - 23V / 2.00A - 3.

User Manual Back-UPS BE650MC

CT-6500 S2. digital circuit breaker analyzer. Vanguard Instruments Company, Inc.

POWERWALKER. Uninterruptible Power Supply. Line Interactive VI 1000/1400/2000. Thank you for purchasing PowerWalker UPS.

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Model NM512-E123. TS1 Conflict Monitor Enhanced 12 Channel Unit With LCD Display. Naztec Operations Manual. For. Published by

8-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

LS8000 USER MANUAL. Kitchen Display Station Controller. with Android TM

Back-UPS RS 550 Installation & Operation

Surge Protectors and Digital Timer

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

EZCT-2KA. current transformer test set

EZCT-2000C current transformer test set

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

Installation and Operation Back-UPS Pro 900

HDMI and Ethernet Extender via 2 Multimode Fibers LC Duplex Connector Extends HDMI+ 10/100M Ethernet Link Up To 800 Meters

Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing

OM-DLTT DATA LOGGER INSTRUCTIONS

OVEN INDUSTRIES, INC.

Version /10/2013. User Manual. Powerline AV Mini Adapter DHP-208AV/DHP-209AV

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

MX 62 CONTROLLER. Certifications. Better detection. Better protection. Monitoring system for gas and flame detection

EZCT-2000C Plus. current transformer test set. Vanguard Instruments Company, Inc.

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

Powerware 9910-P11 and 9910-P16

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Installation Manual for D244X Series 24-volt Power Supplies

SPECIFICATION. SFX Form Factor. SST-ST45SF 450W Switching Power Supply Active PFC Circuit Full Range Input. SFX Form Factor

IST ULTRASTAB Power Supply for high precision transducers

CHAPTER 2: SETUP...5 CHAPTER 1: GENERAL INFORMATION...3 USB HUB BACKGROUND...6 CASCADING LIMITATION...7 USB BACKGROUND...6 DESCRIPTION...

Power Supplies. Chapter The McGraw-Hill Companies, Inc. All rights reserved. Mike Meyers CompTIA A+ Guide to Managing and Troubleshooting PCs

MAJOR VA Power Inverter

Total Reach ISDN/DDS Isolation Card P P30059 Isolation Card

TECHNICAL DATASHEET #TDAX023240

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

Digital Power Probes, ACL120, ACL220, ACL Internal, and DCL5 (#30015, #30023, #30024, #30025)

Version /11/2014. User Manual. PowerLine AV Gigabit Adapter/ PowerLine AV Gigabit Adapter starter kit DHP-600AV

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

USER MANUAL DHP-P500AV/DHP-P501AV VERSION 1.2

THREE-PHASE POWER QUALITY ANALYZER

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Circuit Breaker Analyzer & Timer CAT65

No actual trip output occurs if the upper paddle is removed first.

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Quick Start Guide. Installation. User s Manual 1

Model: VA/230W UPS Backup System

Gas Controller System DGC-06

Enhanced Mini-Chansim Model VCS-232

Table of Contents. Hardware Installation...7 Push Button Security...8. Using the Setup Wizard...9

Installation and Operation Manual Back-UPS BR900G-RS

4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

Model 720 Electromechanical Hour Meter

USER MANUAL 06/06 MULTIFUNCTION DIGITAL RCD TESTER. Tests RCDs, PFC, socket, mains voltage & polarity PDRC 380

EARTHWATTS 750 GREEN POWER SUPPLY USER S MANUAL

EZCT S2A. current transformer test set. Vanguard Instruments Company, Inc.

Electrical Demand Specification (Reference SOP: )

Sentinel Data Loggers

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

LCI User Manual mantracourt.com

Circuit Breaker Analyzer & Timer CAT31

Transcription:

PQR Series Power Quality Recorders For SINGLE, DUAL, THREE PHASE, and ENVIRONMENTAL applications. User - Friendly Data Logging Multiple Channel Monitoring Fast Impulse Detection Easy to Understand Reports Reasonable Pricing Made in USA The PQR Series of Power Quality Recorders are designed to meet a wide range of Power and Environmental testing needs. Models range from the simple - PQR D50, Single Phase to the Sophisticated - PQR 1010, Dual AC, Dual DC, Current, and Temperature recorder, with many Models in between.

PQR D50 * Surges Disturbance Threshold selectable by the operator 1) Plug cord into a grounded outlet 2) Let the unit monitor the line for 24-72 hours 3) Connect to computer for printouts Stores events in non-volatile FLASH RAM * 32,000 Event Storage * Data log 20 Days of readings In addition to full Text Detail and Summary reports, event information such as the Magnitude, Time, and Date of each of the disturbances is converted to useful Pie and Bar Charts on your IBM Compatible PC.

PQR 1010 User - Friendly Multi Channel - AC Voltage, DC Voltage, Current, Humidity and Temperature Disturbance Recorder and Voltage Logger Easy to Understand Reports Simple connection to a Computer or Terminal Made in USA The PQR1010 Power Quality Recorder is a state of the art, fully integrated instrument which measures, records, and reports power disturbances, aiding in the analysis of power quality in medical, commercial and industrial applications. Disturbances detected on multiple channels are recorded by their time, date, magnitude, and duration in a non-volatile RAM memory. This data is then retrieved from the analyzer through its serial communications port. Connections to the PQR-1010 are made between the safety connectors on the back of the unit, and the circuit panel to be tested. The power to operate the unit comes from any standard 110v / 220v AC outlet. Once plugged in, the PQR-1010 immediately begins testing the signals on the input connectors. The PQR 1010 is one of a series of practical power line monitors, designed and priced to be outfitted to everyone who services or installs electrical, and electronic equipment. In addition to full Text Detail and Summary reports, event information such as the Magnitude, Time, and Date of each of the disturbances is also reported. GRAPHICS SOFTWARE INCLUDED! Features Provided with the PQR 1010 is the PQR HOST COMMUNICATIONS Software. This software allows you to easily download the data and display or print the DATALOG chart over time, the PIE CHART of the summary of events or the HISTOGRAM of the detail of events. * Surges * Data Logging 1) Connect the test leads to a service panel 2) Plug the power cord into a grounded outlet 3) Periodically connect to a computer for reports Stores events in non-volatile FLASH RAM * 32,000 Event Storage * Stores the average reading every minute for up to 20 days on each channel

User - Friendly Programmable Multiple Phase Monitoring Fast Impulse Detection Easy to Understand Reports Made in USA PQR 2020 Three Phase Voltage Power Disturbance Monitor The PQR2020 Power Disturbance Analyzer is a state of the art, fully integrated instrument which measures, records, and reports power disturbances, aiding in the analysis of power quality for AC power in medical, commercial and industrial applications. Power disturbances detected on multiple channels are recorded by their time, date, magnitude, and duration in a non-volatile RAM memory. This data is then retrieved from the analyzer through it s serial communications port. Connections to the PQR-2020 are made between the safety connectors on the back of the unit, and the circuit panel to be tested. The power to operate the unit comes from any standard 110v / 220v AC outlet. Once plugged in, the PQR-2020 immediately begins testing the signals on the input connectors. By: PowerTronics

The DETECTIVE Series Models D200 & D300 * Surges Disturbance Threshold selectable by the operator 1) Plug cord into a grounded outlet 2) Let the unit monitor the line for 24-72 hours 3) Connect to printer or computer for printouts Stores events in non-volatile FLASH RAM Model D200 Shown * 32,000 Event Storage * Data log 20 Days of readings Easy to understand full 8-1/2 x 11 printed reports (when connected to a printer) Immediate viewing of disturbance events and programming menus via the unit s LCD display D300 and D200 will test Temperature, The Ground line and DC Voltage D300 is housed in a rugged carrying case, and has a built in printer

PI-500 Power Investigator Full Function Power Disturbance Monitor Very Low Cost * Surges Input Voltage Range 80-300 VAC 1) Plug cord into a grounded outlet 2) Let the unit monitor the line for 24-72 hours 3) Connect to printer for printouts EASY TO USE, EASY TO UNDERSTAND, VERY LOW COST! The Power Investigator generates a Cause and Effect Report which gives a clear understanding of what causes the type of power problems which were detected ON SITE. To fix the problems there s no more guessing. The Power Investigator Solutions Guide Report helps you find the problems and make the right power protection decision.

Probe 100 Monitor Tool Box size monitor measures common-mode noise, spikes, high frequency noise, surges, sags, power failures, and power dropouts Determines if the outlet is wired properly Detects power problems quickly and economically The PROBE continuously monitors the line for high or low AC line voltage conditions. Simple to operate Plug it in, and press the Reset button Periodically check the LEDs The Probe stores events until reset by operator! The Probe is useful in identifying types of power disturbances that are on the line. It is like a snapshot of specific power problems. If you are having a problem with a computer system or peripheral, the Probe can be plugged into the same circuit and left for a period of time. When a problem is experienced with the equipment, immediate checking of the Probe s LEDs will indicate the worst case power problem. If none of the LEDs are illuminated then the problem may be with the hardware. The LEDs that are illuminated indicate the types of disturbances that may be affecting the equipment. The LEDs on the Probe latch in the ON position when the device receives a disturbance.