RadioRA 2 Repeaters extend the range of Radio Frequency () signals that are sent between dimmers, switches, keypads, visor controls, shades / draperies, and other devices. Repeaters ensure error-free communication between system components and prevent interference from neighboring systems. product specifications 369-227d 09.7.0 For systems that extend up to, one () ain Repeater is required to set up the system. Up to four (4) s can be added to extend the range for larger system applications. Each Repeater has an range of, covering a total area of approximately 2500 sq ft (232 m 2 ). RR-AIN-REP-WH odel Numbers RR-AIN-REP-WH* RR-AUX-REP-WH* ain Repeater * Only available in White (WH). RR-AUX-REP-WH www.lutron.com/radiora2 Lutron
Specifications product specifications 369-227d 09.7.0 odel Numbers RR-AIN-REP-WH, RR-AUX-REP-WH ain / : 300 ma DC adapter: Input: 20 V 60 Hz 6.5 W Output: 300 ma Typical Consumption Regulatory Approvals Environment Low-Voltage Wire Type s ESD protection Surge Protection Failure ounting Connections Warranty Design Features ain Repeater: 3. W conditions: one LED on, cable plugged in, powered by the adapter supplied. : 0.6 W conditions: one LED on, powered by the adapter supplied. DC adapter: UL Listed for U.S. and Canada, NO ain / : FCC, IC, COFETEL Ambient operating temperature: 32 F to 04 F (0 C to 40 C), 0% to 90% humidity, non-condensing. Indoor use only. Two pair one pair 8 AWG (.0 mm 2 ), one pair 22 AWG to 8 AWG (0.5 mm 2 to.0 mm 2 ) twisted shielded NEC Class 2 / PELV cable. Repeaters communicate with the system through. All devices (except remote dimmers / switches) must be located within of a Repeater. All Repeaters must be within 60 ft (8 m) of another Repeater. ed to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 6000-4-2. ed to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.4-99 Recommended Practice on Surge Voltages in Low-Voltage AC Circuits. failure memory: should power be interrupted, the Repeater will return to its previous state when power is restored. ount on a wall, ceiling, or level surface using the two #6 (3) screws provided. ain Repeater:,, RS485 and (Lutron use only.) : RS485 Year Limited Warranty. http://www.lutron.com/resiinfo button - enters the system diagnostic mode. button - enters the system address mode. Can be programmed from a PC. RS485 port to connect to other Repeaters through a wired link (daisy-chain). ain Repeaters allow configuration and integration to the system through or ports. See chart below. Configuration Integration X X X 2 Lutron 24/7 Technical Support 800.523.9466
product specifications 369-227d 09.7.0 Dimensions All dimensions are shown as Front View in (mm) Side View 6 4 (59) ain Repeater 5 4 (33) /4 (6) 2 3 4 (70) CO ounting Holes 3 3 4 (95) 6 (27) 4 4 (08) ounting Vertical Horizontal Ceiling Wall #6 (3) screw recommended (2 included) Level Surface www.lutron.com/radiora2 Lutron 3
Operation product specifications 369-227d 09.7.0 ain Repeater CO LEDs Displays the status of the Repeaters in the system while in mode. and wired LEDs Displays the Tx / Rx activity on the and wired links. (Green=Tx; Orange=Rx) and Buttons Press and hold to enter the system into mode or mode. and LEDs Flashes green to indicate that the system is in mode or mode. and Configuration ain or Link (Daisy-chain) 000 ft (305 m) NEC Class 2/PELV cable Two pair one pair 8 AWG (.0 mm 2 ), one pair 22 AWG to 8 AWG (0.5 mm 2 to.0 mm 2 ) twisted shielded. Link 60 ft (8 m) 4 Lutron 24/7 Technical Support 800.523.9466
CO CO CO CO RadioRA 2 Repeaters product specifications 369-227d 09.7.0 Using Two ain Repeaters for Qualified Dealers/Installers Qualified Level 2 (L2) dealers/installers can upgrade their software to provide support for a 200 device system by enabling the addition of a second main repeater subnet to the system. Note: For questions on how to become a qualified L2 dealer/installer, please contact your local Lutron representative. Connection Diagram for 2 ain Repeaters PC Router/HUB/Switch 2 ain repeater subnet # ain repeater subnet #2 ain Repeater ain Repeater ain ain Auxiliary Optional 3 RS485 Dimmer Keypad Auxiliary Dimmer Keypad The two main repeaters must be connected by during and after PC programming. The two main repeaters do not communicate over the link. 2 The two main repeaters may be connected over by one of the following: a. Router b. HUB or switch (only if static IP addresses are being used) c. After PC programming is complete, direct connection without a router, HUB, or switch (only if static IP addresses are being used) 3 Auxiliary repeaters and main repeaters on the same subnet can be optionally connected by RS485 wired links when the repeater range is exceeded. a. The RS485 wired link cannot be connected between the two main repeater subnets b. The RS485 wired link cannot be connected between two main repeaters. c. RS485 wired links can be used between any combination of main and auxiliary repeaters on the same subnet. www.lutron.com/radiora2 Lutron 5
Connections product specifications 369-227d 09.7.0 ain Repeater Top View ini-b Cable: (Lutron use only) Bottom View range: Link (Daisy Chain) To Repeater: 000 ft (305 m) 60 ft (8 m) GND To other devices: CAT5 Cable: 328 ft (00 m) Antenna 9V RS485 Jack (to adapter) odel: T20-9DC-3-BL NEC Class 2 / IEC PELV Cable: 50 ft (5 m) and Pin Numbering 6 7 8 9 5 8765432 Top View Antenna range: To Repeater: 60 ft (8 m) To other devices: Bottom View Link (Daisy Chain) 000 ft (305 m) GND 9V Pin # TxD 2 RxD 3 GND 5 Pin # T+Ve T-Ve 2 R+Ve 3 R-Ve 6 RS485 Jack (to adapter) odel: T20-9DC-3-BL NEC Class 2 / IEC PELV 6 Lutron 24/7 Technical Support 800.523.9466