PV Rapid Shutdown device

Similar documents
Installation/User Manual

M215 (M215-60) Safety

M250 (M LL) Safety

Enphase S-Series Microinverter and Engage Cable Safety

Installation/User Manual

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

Installation/User Manual

Solis Single Phase Inverter

M215-Z Safety Information (M LL-IG-ZC)

-5K-2G. Solar PV Grid Tie Inverter. inverter. Installation and Operation Manual. 2013, Ningbo Ginlong Technologies Co., Ltd.

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

SAVE THESE INSTRUCTIONS

5504 Thermocouple Analog Input Module

GCI-2G-W Single Phase Inverter

GCI-5K INSTALLATION AND OPERATOR S MANUAL

P216 Series Condenser Fan Speed Controller

Installing Enphase IQ 7, IQ 7+ and IQ 7X Microinverters

Replacing the Power Supply

Solis Single Phase Inverter

Rapid Shutdown Requirements for NEC 2017

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Solis Single Phase Inverter

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

Installing Enphase IQ 6 and IQ 6+ Microinverters

Solis Three Phase Inverter

Solis 4G Single Phase Inverter

iconverter 2-Module Power Chassis

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Installation and Operations Manual. Enphase Microinverter Model M215

Please read these instructions carefully before installing This will ensure an easy start and a great first customer experience with TS4 installation

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

PanelView Plus/VersaView CE Terminals and Display Modules

Meikai N220/N300 Micro-Inverter Installation and Operation Manual

Model Number Electrical Compatibility Module Connector Type M LL-S22 M LL-S22-NA M LL-S23 M LL-S23-NA

Solar Combiner Enclosure

Installation / User Manual

M215 Microinverter Installation Planning

Solis 4G Single Phase Inverter

Installation Job Aid for Ethernet Routing Switch 5900 Series

SLK Grid PV-inverter (UL) Installation and Operation Manual

Installation and Operations Manual. Enphase Microinverter Models M190 and M210

P216. Condenser fan speed controller. Product bulletin. Features

Installation, Operation and Maintenance Manual

TRC-190 User s Manual

Microinverters And The Solar Industry

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Installation and Operations Manual. Enphase Micro-Inverter Models M and M

DOWNLOAD PDF ENPHASE M250 INSTALLATION GUIDE

Installing Enphase IQ 6 and IQ 6+ Microinverters

FHOTON WI-FI MODULE Owner's Manual

System Design Guide. APsystems YC Photovoltaic 3-Phase Grid-connected Microinverter. APsystems. Version 1.1 3/15

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

S66 Series Electronic Fan Speed Control

Enphase Microinverter Model M215

Bulletin Installation of solar photovoltaic systems Rules , , , , and

Enphase M215 Microinverter , Rev 06

Installation Job Aid for VSP 4850GTS

Enphase M215 Microinverter , Rev 06

Installing Enphase M250 and M215 Microinverters

HT2000 Transverter Installation & Operation Manual

TRC-190 User s Manual

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Installation and Operations Manual INVOLAR MAC250 Microinverter

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Conergy PH Series Modules. Solar module user manual

Rev1 QP-10-IM21UL/Rev Rev2 QP-10-IM21UL/Rev Rev3 QP-10-IM21UL/Rev Rev4 QP-10-IM21UL/Rev4

5401 and 5402 Digital I/O Modules

Instruction Sheet Board Style Low Water Cutoff

A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Installation Job Aid for VSP 4450GTX-HT- PWR+

Operating Instructions

Installing Enphase IQ 7, IQ 7+ and IQ 7X Microinverters

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

PRO-75 SERIES. User manual

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Installa and Opera Manual

Table of Contents Product Overview Before using the product Installation Procedure... 5

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Installation and Operations Manual. Enphase Microinverter Models M190 and M210

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Analog Monitor Installation Manual

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Satellite INSTALLATION GUIDE

Solis Three Phase Inverter

Power Supply Installation

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Installation Instructions

Installing the Enphase Envoy-S Metered

Installing the Cisco AS5400XM Universal Gateway

SEM3 - Embedded Micro Metering Module

Installation / User Manual

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

Transcription:

PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl. S. Suite 3214, Dublin OH 43017, USA Toll-free: 866.438.8408 I Email: sales@ginlong.com I sales@ginlong-usa.com Web: www.ginlong.com I www.ginlong-usa.com Please record the serial number of your Rapid Shutdown Device and quote this when you contact us. C 2016, Ningbo Ginlong Technologies Co., Ltd. Ver 1.0

Contents 1. Introduction 2 1.1 Product Description 2 1.2 Packaging 3 2. Safety Instructions 2.1 Safety Symbols 2.2 General Safety Instructions 3. Installation 3.1 System diagram 4 4 4 6 6 3.2 Installation 4. Commissioning 5. Troubleshooting 7 12 12 6. Specifications 13 6.1 Technical Specifications 13.1.

Installation and Operation Manual C Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) 2016, Ningbo Ginlong Technologies Co., Ltd. Ver 1.0 1. Introduction 1. Introduction 1.1 Product Description The Solis Rapid Shutdown Devices (RSD) are certified to the UL 1741 inverter standard and comply to all 2014 National Electrical Code 690.12 Rapid Shutdown requirements. Solis RSD's are packaged inside NEMA 4X enclosures that fit neatly under the modules. The RSD is controlled by an AC signal circuit. A green LED on the RSD indicates that AC power is supplied to the RSD and that RSD PV output circuits may be energized. When first responders cut AC power to the building, the RSD(s) will force the PV array and DC capacitors inside the inverter(s) to drop to less than 30VDC and less than 240VA in less than 10 seconds. 1.2 Packaging When you receive the RSD, please ensure that all the parts listed below are included: PV Rapid Shutdown device 1 2 3 Figure 1.3 Parts Part # Description 1 Rapid Shutdown Device 2 AC Terminal Assembly 3 Manual Number 1 1 1 Figure 1.1 Front side view Table 1.1 Parts list Figure 1.2 Back side view.2..3.

2.Safety Instructions 2.Safety Instructions Improper use may result in potential electric shock hazards or burns. This manual contains important instructions that must be followed during installation and maintenance. Please read these instructions carefully before use and keep them for future reference. 2.1 Safety Symbols Safety symbols used in this manual, which highlight potential safety risks and important safety information, are listed as follows: WARNING symbol indicates important safety instructions, which if not correctly followed, could result in serious injury or death. CAUTION: CAUTION, RISK OF ELECTRIC SHOCK symbol indicates important safety instructions, which if not correctly followed, could result in electric shock. CAUTION: CAUTION, HOT SURFACE symbol indicates safety instructions, which if not correctly followed, could result in burns. CAUTION: An electric shock can be fatal. Inadequately sized electrical components can cause serious injury and damage to property. - All electrical connections must be made in accordance with the National Electrical Code, ANSI/NFPA 70, and any other regulations applicable to the installation site. - Use min.194 F (90 C) copper wire for all grounding wires (see NEC table 250.122). - Voltage drop and other considerations may mean larger cable cross sections need to be used. The PV array (i.e. the solar panel ) supplies a DC voltage when it is exposed to sunlight. ATTENTION: ATTENTION; Installers of the RSD shall have a reflective, white-on-red, permanent plaque or directory that includes the following wording; PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN CAUTION: The surface temperature of the RSD can reach up to 75C (167F). To avoid risk of burns, do not touch the surface of the RSD when it is operating. 2.2 General Safety Instructions Incorrect operation or maintance can cause serious injury and damage to property. Only qualified personnel to commission the Rapid Shutdown Device and only within the scope of the respective technical regulations. Read the safety rules before commissioning and performing maintenance work. Work performed incorrectly can cause serious injury and damage. The Rapid Shutdown Device should only be installed by qualified personnel. Follow the safety rules! Before any installation or connection work is carried out, disconnect the AC supply to the inverter and the DC supply to the Rapid Shutdown Box..4..5.

3. Installation 3. Installation 3.1 System Diagram The Ginlong Rapid Shutdown Device is controlled by an AC signal circuit. If AC power is cut at the utility service entrance and/or at the inverter AC output circuit disconnect, the RSD will be activated and the PV array will drop to less than 30 volts in less than 10 seconds (per 2014 NEC 690.12). 3.2 Installation RSD is designed to mount on the rack under PV modules. Step 1. Attaching RSD to the racking. Solis-RSD-1G(1:1) Figure 3.2 Attaching RSD to rack Solis-RSD-1G(2:2) a. Evaluate the location of the RSD with respect to the PV module junction box or any other obstructions. Allow a minimum of 3/4 inches between the top of the roof and the bottom of the RSD. We also recommend that you allow 1/2 inches between the back of the PV module and the top of the RSD. Do not mount the RSD in a location that allows exposure to direct sunlight. Figure 3.1 System diagram b. If using grounding washers (e.g. WEEB) to ground the RSD chassis to the PV module racking, choose a grounding washer that is approved for the racking manufacturer. Install a minimum of one grounding washer for RSD. The Torque for the fasteners values listed below: 1/4 mounting hardware 45 inlbs minimum 5/16 mounting hardware 80 inlbs minimum..6..7.

3. Installation 3. Installation Figure 3.3 Fix the screws Step 2 - Using MC4 connectors, connect the DC input and DC output wires. RSD-1G(1:1) DC connection: The single channel RSD-1G (1:1) enclosure is rated for 20 amps. Installers may parallel wire more than 1 pair of PV string conductor to the single channel RSD-1G (1:1) input connectors. However, the total Imax current must be less than 20 amps and Isc current less than 31.2 amps. Any parallel wiring of PV module strings on the roof must be accomplished per NEC guidelines. RSD-1G(2:2) DC connection: The dual channel RSD-1G (2:2) enclosure is rated for 30 amps. Either channel can accept 20 amps (31.2 Isc). Installers may parallel wire more than 1 pair of PV string conductors to one of the channels on the dual channel RSD-1G (2:2). However, when the installer connects a PV string(s) to the second channel, they must be sure that the 30 amp total RSD-1G (2:2) enclosure rating has not been exceeded. Any parallel wiring of PV module strings on the roof must be accomplished per NEC guidelines. a. Connect PV string to RSD STR DC side, connect inverter DC input to RSD INV DC side. Each RSD includes an AC 3-pin weathertight bulkhead receptacle on a short pigtail. One (1) AC 3-pin mating connector assembly comes with each unit. Follow the instructions below to assemble the AC signal circuit connectors and make all connections. a. Use an appropriate 3-wire cable for the AC signal circuit connection. The AC signal circuit cable wire size can range from 18AWG to 14AWG. b. Follow the wiring sequence below to connect the cable to the AC 3-pin weathertight connector The string input PV+ and PV- must match RSD PV+ and PV-. Reverse PV input polarity could damage the RSD and void the warranty. 240V AC Black - L1 Red - L2 Green - Ground (Optional) Figure 3.4 Connect DC input and DC output MC4 connectors Step 3 - Connect AC terminal of RSD Pin 1 - Black L1 Pin 3 - Red L2 Pin 2- Ground Table 3.1 AC cable connection sequence.8..9.

3. Installation 3. Installation c. Please see Figure 3.5 for proper assembly of the 3-pin AC connector. After assembly, connect the connector to the RSD bulkhead receptacle. a. Follow instructions in the Ginlong Inverter Installation Manual to connect the RSD DC output conductors to the inverter DC input terminal blocks inside the inverter wire box. Check to ensure that DC polarity is correct. Step 4 - Grounding the System Figure 3.5 Assembly of the AC connector b. Connect RSD GRID Connect the RSD GRID conductors (i.e. AC signal circuit conductors) to a 240VAC termination point, inside or outside the Ginlong Solis inverter wire box. A 2-amp ac fuse is integrated in RSD to protect the RSD AC signal circuit components and conductors. Attention To ensure AC signal quality, the AC signal circuit conductors must be no longer than 100 meters. Attention After installation of one or more RSD's on site, the system installer will install a plaque (per 2014 NEC 690.56(C)) that reads: PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN. Additional signage on site can include a plaque next to the Inverter AC Disconnect Switch that reads: OPERATION OF THE PV SYSTEM AC DISCONNECT SWITCH WILL RESULT IN RAPID SHUTDOWN OF THE PHOTOVOLTAIC ARRAY AND INTERRUPTION OF SYSTEM POWER. Figure 3.6 Ground connection If you are not using grounding washers to ground the RSD chassis please follow the step below. Each RSD comes with a ground clip that can accommodate a single #6, #8, or #10 AWG conductor. Check your local code for grounding conductor sizing requirements. a. Connect the grounding electrode conductor to the RSD ground clamp. Torque the RSD ground clamp to 20 in-lbs, 2.25 N-m. The racking and module could be grounded to this conductor using a crimp connection. Step 5 Complete the RSD installation by routing the RSD DC output conductors and the AC signal circuit conductors to the wire box on the Solis inverter. The RSD and all ac connections to the utility grid must only be made by qualified personnel. Ensure that all AC and DC wiring is correct. Ensure that none of the AC and DC wires are pinched or damaged. Ensure that all wiring boxes are properly closed. a. Follow instructions in the Ginlong Inverter Installation Manual to connect the RSD DC output conductors to the inverter DC input terminal blocks inside the inverter wire box. Check to ensure that DC polarity is correct..10..11.

4. Commissioning 6. Specifications To commission the PV system with the Solis RSD(s) installed: a. Move the Inverter AC output circuit disconnect switch to the ON position b. Move the PV system inverter output circuit breakers to the ON position c. Ensure that RSD AC signal circuit conductors are energized d. Confirm the correct polarity of the DC input circuit conductors. e. Move the DC switch on the inverter to the ON position f. Confirm the inverter turns ON in 300 seconds (5 minutes) 5. Troubleshooting The RSD and all ac connections to the utility grid must only be made by qualified personnel. Failure of the RSD could interrupt DC power to the inverter. If the installer checks the DC input terminals at the inverter and does not detect PV voltage, the installer should follow the procedure below: a. Check DC string voltage at the inverter as a way to isolate the issue to the RSD or to the inverter. b. If the DC voltage can be measured at the DC input terminals at the inverter, follow inverter troubleshooting instructions. c. If DC voltage cannot be measured at the DC input terminals at the inverter, Check the AC signal circuit connection point to confirm that AC power is available at these terminals. d. If there is AC power at the AC signal circuit connection point, check to see if the RSD LED is lit. This would indicate that the RSD has AC signal circuit power. Check for loose MC4 connections at the RSD DC inputs and outputs. e. If the RSD LED is off, check all AC and DC cable connections. f. After confirming the integrity of the DC cable connections and confirming that the RSD is receiving AC power, but the LED is still OFF, replace the RSD. 6.1 Technical Specifications DC Maximum Input and Output Voltage DC Input Voltage Range Maximum Number of PV Source Circuits Maximum Input / Output Current Maximum Short Circuit Current DC Input / Output Cable Whips DC Input / Output Wire Size Ground Wire Size AC Rated AC Input Voltage Rated AC Input Current Rated Frequency AC Control Wire Size Maximum AC Fuse Rating GENERAL Ambient Temperature Range Enclosure Type Roof Mount Style Status Indicator Efficiency Response Time Dimensions (W*H*D) Weight Warranty Certification & Safety Standard Compliance Solis-RSD-1G 1:1 600VDC 30-600VDC 1 input / 1 output 20A 31.2A PV Wire with MC4 Locking Connectors AWG #12 to #6 AWG #10 to #6 208/240VAC 0.1A 50/60Hz AWG #18 to #14 2A -25 to +65 C (-13 to 158 F) NEMA 4X Rail-mount plate (WEEB Compatible) LED >99.5% <2 seconds 262*240*43 cm / 10.3*9.4*1.7 in 2.3 kg / 5.1 lb 10 Year UL1741, FCC Part 15 Class B, NEC 690.12.12..13.

6. Specifications DC Maximum Input and Output Voltage DC Input Voltage Range Maximum Number of PV Source Circuits Maximum Input / Output Current Maximum Short Circuit Current DC Input / Output Cable Whips DC Input / Output Wire Size Ground Wire Size AC Rated AC Input Voltage Rated AC Input Current Rated Frequency AC Control Wire Size Maximum AC Fuse Rating Solis-RSD-1G 2:2 600VDC 30-600VDC 2 input / 2 output 10/20A 31.2A PV Wire with MC4 Locking Connectors AWG #12 to #6 AWG #10 to #6 208/240VAC 0.1A 50/60Hz AWG #18 to #14 2A GENERAL Ambient Temperature Range Enclosure Type Roof Mount Style Status Indicator Efficiency Response Time Dimensions (W*H*D) Weight Warranty Certification & Safety Standard Compliance -25 to +65 C (-13 to 158 F) NEMA 4X Rail-mount plate (WEEB Compatible) LED >99.5% <2 seconds 262*240*43 cm / 10.3*9.4*1.7 in 2.4 kg / 5.2 lb 10 Year UL1741, FCC Part 15 Class B, NEC 690.12.14.