Power supply unit NG3-16ib

Similar documents
Emergency power supply NV2.1-12iaE

Speaking Station LV30

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

PI-EX-ME-2NAM/COC-24VDC

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

Redundancy Module QUINT-DIODE/40

PHOENIX CONTACT - 01/2008

SolConeX Wall-Mounted Socket, 16 A

5 Fieldbus Technology

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

SolConeX extra-low voltage flange socket

PHOENIX CONTACT - 05/2007

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

M E M O R A N D U M I.S.

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

Operating Manual -ENGLISH- Page 1 KWG-ISO

C9900-P223 and C9900-P224

Product manual plug, sockets and coupler 16 A.- Z0251

PHOENIX CONTACT - 02/2008

FLEX Ex Spring Clamp Terminal Base

Installation & Operation Manual

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Power supply CP-C 24/5.0

Installation & Operation Manual

Inductive sensor with analog output BI15-M30-LI-EXI

Interface and Supply module. IPC 3x0i / PSC 3x0i

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

IECEx Certificate of Conformity Annexe

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Safety Instructions Cerabar S PMP71, PMP75

SUBCON-PLUS-PROFIB...

TEPI11 P/I signal converter

Intrinsically safe batch controller Batching Master 110i

Operating Instructions

Conveyor Belt Alignment Switches from IDEM

CMC III Temperature/Humidity Sensor

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights.

Redundancy unit CP-A RU

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

MACX MCR-EX-SD LP(-SP)

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Operating instructions. Switching amplifier DN0210 DN / / 2015

High Power Electronic Gear Installation and operation Guide

Installation manual plugs and connectors with screw connection (16/32 A)

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

PHOENIX CONTACT - 07/2006

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

C9900-P208 and C9900-P209

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

Inductive sensor NI3-EG08K-Y1-H1341

Operation Manual. Capacitor Boxes adjustable 80 A / 125 A Track, 2,04 μf to 8 μf. Order Number

QUINT-BUFFER/24DC/24DC/40

Float Switches with Permanent Magnet For Vertical Installation Model RSM

SMARTLINE RM76 Supplementary instructions

TRIO-DIODE/12-24DC/2X10/1X20

CMC III Universal Sensor

LED Driver Linear / area fixed output

IF-80x Outdoor Terminal

Demonstration Case BENNING DB 1

Isolating repeater IRU 420

MINI-PS AC/10-15DC/8

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Cable Entry Systems for Potentially Explosive Atmospheres

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Instruction Manual. T3110 T3110L T3110Ex

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Inductive sensor BI1.5-EG08-Y1-H1341

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Operating Instructions

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR UC/ESAM4/3X1/1X2/B

LED Driver Linear / area fixed output

IECEx Certificate of Conformity

STEP-PS/1AC/24DC/1.75

CPCI-PS24 24V-Power Supply

LED Driver Linear / area fixed output

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

LED Driver Compact fixed output

Transcription:

Ordering Data Designation Type Item no. Power supply unit NG3-16ib (42 V AC / ) 371 008 31 AX Power supply unit NG3-16ib (230 V AC / ) 371 008 32 AX Power supply unit NG3-16ib (100 V AC / ) 371 008 34 AX Power supply unit NG3-16ib (240 V AC / 60 Hz) 371 008 35 AX Power supply unit NG3-16ib (167 V AC / ) 371 008 36 AX Power supply unit NG3-16ib (36 V AC / ) 371 008 38 AX Power supply unit NG3-16ib (24 V AC / ) 371 008 39 AX Universal power supply unit in different input voltage versions for the power supply of intrinsically safe installations which are protected against firedamp with 16 V direct voltage. Versions for AC input () at 24 V AC 36 V AC 42 V AC 100 V AC 167 V AC 230 V AC and 240 V AC / (60 Hz) Constant DC output voltage / (limited current and voltage values) Output voltage indication through LED Output as per protection type Intrinsically safe, cat. Ib For use in type e (increased safety) terminal boxes with PG29 screw-in thread Application The power supply unit NG3-16ib enables the power supply of electrical equipment items operated in intrinsically safe systems within hazardous locations which are susceptible to firedamp. The power supply unit NG3-16ib provides protection as per I M 2 EEx m [ib] I. Based on a non-intrinsically safe AC input voltage, a regulated, currentlimited and intrinsically safe of / is generated in the output circuit. For details of the non-intrinsically safe mains voltage and of the of the intrinsically safe DC output voltage, refer to the nameplate of the power supply unit. Copyright FHF Bergbautechnik GmbH & Co. KG 12.2004 Subject to technical modifications without notice. Page 1

Configuration The power supply unit NG3-16ib is mounted into an enamel gray cast iron housing. The housing consists of a tublike bottom section and a vaulted cover. The cover is pressed onto the bottom section by means of two screws, with a sealing as intermediate layer, and constitutes the intrinsically safe terminal box. The main compartment of the housing's bottom section combines the mains transformer and the electronics module which are completely embedded in sealing compound. Only the 2-pole terminal strip for the connection of the intrinsically safe output circuit and the LED for the function indicating jut out of the compound. This LED is on, if the intrinsically safe output voltage is applied and no short-circuit has occurred on the output side. The LED is visible from the outside through a sight glass in the housing cover. The electronics module consists of a mains transformator serving as isolation between the non-intrinsically safe supply net and the downstream electronic voltage and current regulation. A voltage transformer and two electronic current / voltage-limiting stages connected in series ensure a stabilized output voltage (within the limits of the non-intrinsically safe input voltage). Two electronic overload stages which act independently from one another, switch off the intrinsically safe output voltage in case of an overload or a short-circuit on the output side. The switch-off or on again of the intrinsically safe output circuit due to overload is repeated in intervals until the short-circuit or the overload has been eliminated. The LED for indicatiang the function flashes in the cycle of the switch-off and on of the intrinsically safe output voltage. On one of the housing sides, the power supply unit NG3-16ib has a PG29- threaded bush for leading out a 3-wire connecting cable used for the connection with the non-intrinsically safe supply net. By means of threaded bush, the power supply unit is screwed in appropriate bores of housings offering protection type "increased safety" and at the same time fixed and secured. The opposite housing side is equipped with a PG16 gland for line diameters from 9 to 14 mm and a PG16 blind plug. The PG16 line entry (incl. strain relief, protection against buckling and twisting) is used for leading through the connecting cables for the intrinsically safe output circuit. Dimension drawing NG3-16ib max. screw diam. blind plug PG 16 metal PG16 line entry lead out cable for mains connection Copyright FHF Bergbautechnik GmbH & Co. KG 12.2004 Subject to technical modifications without notice. Page 2

Wiring diagram EEx e I Non-intrinsically safe Mains: 24/36/42/100/127/ 230 V AC () / 240 V AC (60 Hz) 1 2 L N PE / EEx ib I intrinsically safe Copyright FHF Bergbautechnik GmbH & Co. KG 12.2004 Subject to technical modifications without notice. Page 3

Technical Data NG3-16ib Designation Type Power supply unit NG3-16ib Item no. 371 008 31 AX 42 V AC 0.5 A Voltage tolerance + 20%; -30% Item no. 371 008 32 AX 230 V AC 0.1 A Item no. 371 008 34 AX 100 V AC 0.25 A Item no. 371 008 35 AX 240 V AC 0.1 A 60 Hz Item no. 371 008 36 AX 167 V AC 0.2 A Control better than 0.5 % for mains voltage deviations(load and temperature being within the permitted Copyright FHF Bergbautechnik GmbH & Co. KG 12.2004 Subject to technical modifications without notice. Page 4

Technical Data NG3-16ib Item no. 371 008 38 AX 36 V AC 0.7 A Item no. 371 008 39 AX 24 V AC 0.9 A Parameters: Output (supply) circuit: Max. output voltage U 0 16.2 V DC Max. output current I 0 0.46 A Capacitance (bei L 0 = 0) C 0 4 µf Inductance ( bei C 0 = 0) L 0 130 µh Indications LED output voltage indication Connections Non-intrinsically safe supply voltage: Cable entry: ON, if output voltage is applied OFF, if output voltage is not applied or shortcircuited. securely fixed plastic-sheated flexible cord YSLÖ- J, 3 x 1mm2, length: 1 m which is led out through the PG29 threaded bush (optionally connection with single cores available) 2 terminals with pressure plates (wire protection) connecting capability 2 x 1.5 mm² finely stranded each 1 x PG16 (line diameters 9-14 mm) 1 x PG16 blind plug Copyright FHF Bergbautechnik GmbH & Co. KG 12.2004 Subject to technical modifications without notice. Page 5

Technical Data NG3-16ib Further parameters Enclosure Gray cast iron, colour: dark grey Enclosure protection degree IP 54 as per IEC 529 Operating mode 100 % ED / continuous operation Operating conditions preferably in firedamp environments Operating position at choice (preferably in vertical position, with the cable entries facing downwards) Temperature range - operation - storage - transport Dimensions Weight Test and approval - type of protection - approval no. - 20 to + 40 C - 20 to + 60 C - 20 to + 60 C see dimension sheet ca. 6.8 kg I M 2 EEx m [ib] I DMT 02 ATEX E041 X Marking The nameplate is marked as follows: Company FHF Bergbautechnik GmbH D-42551 Velbert Type NG3-16ib I M 2 EEx m [ib] I DMT 02 ATEX E041 X 0158 Non-intrinsically safe circuit U / I (as per table "Technical data") Intrinsically safe circuit U = 16V / I = L ext. = 130µH C ext =4µF F. No... test...(initials, month/year) Copyright FHF Bergbautechnik GmbH & Co. KG 12.2004 Subject to technical modifications without notice. Page 6

Installation and Assembly The threaded bush of the power supply unit NG3-16ib has to be screwed into an appropriate bore of an approved housing of protection type "increased safety", and the unit has to be fixed and secured. An appropriate sealing is to be used in order to ensure that the housing protection type of at least IP54 will still be ensured after mounting of the power supply unit. If possible, the device should be installed vertically (with the cable entries facing downwards). The device may only be connected to the appropriate supply voltage. Prior to working on the mains connection, the feed lines are to be de-energized. All wires of the connecting line (optionally single cores) must be connected to appropriate terminals or insulated in compliance with the regulations of installation. To connect the intrinsically safe output circuit, remove the housing cover, lead the connecting line into the corresponding cable entry (designed for lines with diameters of 9-14mm) and connect it to the two terminals in the intrinsically safe terminal housing. In case of a fixed installation of this connecting cable, possibly, an appropriate gland fitting can be used instead of the cable entries. Maintenance The device does not contain any parts requiring maintenance. Waste Disposal The disposal of the packaging material and of used parts must be realised in compliance with the regulations of the country in which the device is installed. Copyright FHF Bergbautechnik GmbH & Co. KG 12.2004 Subject to technical modifications without notice. Page 7

Warning and Safety Advice The apparatus is a flameproof device of safety-class group I. Please pay particular attention to the following warning and safety advice: The apparatus is to be connected and installed in accordance with the specified installation instructions by qualified personnel, taking into account the protection type indicated. Only connect the device to the specified, appropriate supply voltage. Prior to working on the mains connection and on the connections of the connecting cables of protection type e (increased safety), feed lines are to be de-energized. All wires of the connecting cables of protection type e (increased safety) have to be connected to appropriate terminals or insulated in compliance with the regulations of installation. If these lines may get into contact with metallic parts, they must be protected mechanically or be fixed in order to protect them against damages. The interconnection with other electric equipment must be separately certified. The device is intended for use in firedamp mining environments. The device may only be connected and operated with the specified voltage. The polarity specifications are to be observed. Make sure the PE conductor is always properly connected as specified. Make sure the housing is not damaged. The device may only be operated under the specified ambient conditions. Unfavourable ambient conditions may damage the appliance, possibly jeopardising the user s life as a result. Unfavourable ambient conditions may be: moisture, dust (observe type of protection) air humidity too high (> 75% rel., condensing) inflammable gases, vapours, solvents not covered by the protection class of the device. ambient temperatures too high (>+40 C) ambient temperatures too low (<-20 C). The ambient temperature specified for the device may not be exceeded or failed to be reached during operation (-20 C up to +40 C), storage and transport (-20 C up to +60 C). Only use the cable glands/entries specified by the manufacturer. Preferably, the device is mounted vertically, with the cable glands and plug connectors facing downwards at the bottom side. When mounting the device, it is to be ensured that the device will not be used as climbing aid and thus be damaged. If required, additional measures must be taken to protect the device against falling objects. Any faulty connection lines on the devices shall be replaced. Repair work may only be realised by the manufacturer or by a person authorized by the manufacturer. Subsequently, a new routine test for the device must be carried out. Make sure the device is protected against damage during transport, storage and when not in use. Attention: Disregarding the above points will nullify the explosion protection. The device then represents a danger to the life of the operator and may cause a hazardous atmosphere to explode. FHF Bergbautechnik GmbH & Co. KG Eintrachtstr. 95 D-42551 Velbert Tel:(02051) 270 0 Fax: (02051) 270-366 Mail: info@fhf-bt.de URL :www.fhf-bt.de Copyright FHF Bergbautechnik GmbH & Co. KG 12.2004 Subject to technical modifications without notice. Page 8