Configuration Note Iwatsu ADIX * / ADIX M *

Similar documents
Inter-Tel IMX 1224/2448/2460*

Lucent Merlin Legend. Configuration Note Lucent Merlin Legend. Revised 1/24/00

Mitel 200 Light. Voice Board(s) Analog Ports. Personal Computer. Configuration Note Mitel SX200 Light * ONS. Revised 6/2/99

Smooth Operator Configuration Note

Smooth Operator Configuration Note

Smooth Operator Configuration Note

Smooth Operator Configuration Note

Smooth Operator Configuration Note

Smooth Operator Configuration Note

Panasonic KX-T30810/T61610 *

Smooth Operator Configuration Note

Mitel SX200D / SX200 Light

AVAYA Merlin Legend/Magix

Cisco CallManager w/vg-248

Toshiba DK280/424 with SMDI

Sopho-S/iS3000 Series

Intecom E / PointSpan 6880

Nortel DMS-100, SL-100 & DMS-250, DMS-500

Mitel SX-200D*/SX-200 Light*

Mitel SX-2000/SX-2000 LIGHT

Cisco CallManager & VG-248 Gateway

ROLM CBX 9751 (9005) Set Emulation (RP400) Configuration Note Version D (09/05)

Lucent 5ESS. with 3A Translator. Configuration Note Ver. D 6/06

Integration Note. Title: Panasonic KX-TD Integration. Overview. Theory of Operation. PBX Requirements and Programming. Programming

Cisco Call Manager T-1 / QSIG. Configuration Note Rev. M (7/09)

Cisco Call Manager T-1 / QSIG. Configuration Note Rev. K (07/08)

Cisco Call Manager T-1 / QSIG. Configuration Note Rev. O (1/10)

Toshiba CIX Telephone End User Training Reference

Cisco Call Manager E1/QSIG - EMEA. Configuration Note Version M (1/10)

East-Central Vermont Community Fiber-Optic Network

PARTNER Messaging System User s Guide

AVAYA IP600 - Set Emulation

Single-Line Telephone. User Guide

AVAYA MultiVantage S8700/S Set Emulation

Multiline Telephone User Guide

Placing Calls. Using Your Single Line Telephone. Placing an Outside Call... Calling a Co-Worker, Voice Mail and Paging...

Administration for the Nortel Norstar Switch

Executone Medley Phone Instructions (Not All Phones Have All Features)

Configuration Note 6102 Rev. D (12/03) GPT isdx - DPNSS (UK & Ireland)

Single-Line Telephone User Guide

VOICE PROCESSING. VP 100, 200 and 300 USER GUIDE TOSHIBA VOICE PROCESSING

Onyx VS Base Release Notes

IP Office Essential Edition PARTNER Mode M7100 Phone User Guide

2018/06/14 00:32 1/2 KX-TDA TAPI

Panasonic KX-TDA TAPI

Axxess Phone Instructions (NOT ALL PHONES HAVE ALL FEATURES)

Analogue Single Line Telephone (SLT) Quick Reference Guide Version 1.0

Serial and Inband Switch Integration

User Guide KX-NT321 Key Communications, Inc Junction Marketplace

DIGITAL TELEPHONE USER GUIDE

i-series Digital Single Line (DSL) Analog Single Line (SLT) Quick Reference Guide

ANALOGUE TELEPHONE USER GUIDE

Inter-Tel Axxess Executive Digital Terminal Reference Guide to Frequently Used Features

Using Your Single Line Telephone

Norstar ICS Telephone Feature Guide

Installing And Programming The Digital Voice Announce Equipment On The DXP, DXP Plus, And FX Series Systems

Application Notes for DuVoice DV2000 with Avaya Communication Manager Using Analog Mode Code Integration Issue 1.0

Humboldt State University. 203 Digital User Guide. ITS Technology Help Desk Digital

SNOM 360 USER GUIDE TABLE OF CONTENTS

Internet Phone. User Guide

Voice Mail System User s Guide

InMail Feature Manual

Integration Notes-Switch # 925

Super Display Telephone Quick Reference Guide DQG05 April Printed in U.S.A. (2562)

IP Office Basic Edition Quick Mode T7100 Phone User Guide

DuVoice Voice Mail provides hospitality and business messaging for the Avaya IP Office, as well as unified messaging and fax capabilities.

Digital Telephone User Guide

Using Your Telephone. The Soft Keys provide quick and easy access to features - just follow the menu on the display (not available on all models).

Oregon Phone Quick Reference Guide For Partner Mail VS R5 Setup

Elite & InnLine 2020 Voice Mail PBX Installation and Testing Guide. Mitel SX-2000 DNIC Integration Using D/82U voice cards

Vertical 2-Line Desk Phone Quick Reference Guide

DS-5000 Series. Keysets. Quick Reference Guide

FEATURE OPERATION CODES

TC-308, TC-616 TC-308-VM, TC-616-VM TC-616-NHR, TC-616-NHR-VM

Application Notes for DuVoice DV2000 with Avaya Communication Manager Using Digital Station Interface Issue 0.2

Dear Valued Customer:

InMail Feature Manual

NVM-2e Installation Instructions and Release Notes for Versions 1.08, , and 1.20

LED Indications. Lamp Status

Using Your Single Line Telephone

SIP Communicator Spitfire S300 User Guide

Digital Voice Services Residential User Guide

Abstract. Avaya Solution & Interoperability Test Lab

Super Display Telephone User Guide

Enterprise Edge ATA 2 User Guide

DS 24D. Digital Keyset. Quick Reference Guide. Samsung Means Business

LET YOUR PHONE WORK FOR YOU.

NEC NEAX 2000 IPS USER GUIDE

CHAPTER 1 INSTALLATION & TRAINING IN THIS CHAPTER:

Industry Standard Telephone (IST) Station User s Guide. DXP, DXP Plus, and FX Digital Telephone Systems

STANDARD TELEPHONE USER GUIDE

Humboldt State University. Analog User Guide. ITS Technology Help Desk Analog Phone

F9600 F9600c SINGLE LINE TELEPHONE USER GUIDE

M7324 Telephone User Card

DIGITAL PHONE USER GUIDE

1.4 Receiving Calls. Receiving Calls Operations. PT and SLT. or INTERCOM

Mitel SX-2000 DNIC Integration using Dialogic Media Gateways 1841 Bourbon Road Cross Plains, Wisconsin

STANDARD TELEPHONE USER GUIDE

ShoreTel 115 IP Phone User Guide

Engineering Bulletin

Transcription:

Octel 50 Messaging Server Configuration Note 77105 Iwatsu ADIX * / ADIX M * Revised 1/31/00 Iwatsu ADIX / ADIX M Analog Ports Voice Board(s) Personal Computer Inband signaling is used for integration Supported Voice Processing Module 1.0 METHOD OF INTEGRATION Inband signaling is used for integration. Call forward to personal greeting is achieved via DTMF signals passed from the Iwatsu ADIX to the Octel 50 family of products. Message waiting indicators are set and canceled by dialing a feature access code followed by the extension number. A hookflash followed by the extension transfers the caller to the operator. 1.1 SUPPORTED VOICE PROCESSING MODULE The Octel 50 is a Year 2000 (Y2K) compliant, PC based, enhanced voice messaging product release intended to replace the Smooth Operator, Smooth Operator Lite and Cooperator product lines. Disclaimer: Configuration Notes are designed to be a general guide reflecting Octel Corporation, a subsidiary of Lucent Technologies Inc., experience configuring its systems. The information contained in this note is based on knowledge available at the time of publication and is subject to change without notice. Please understand that you may experience a problem not detailed in a Configuration Note. If so, please notify Sales Design Support Center (SDSC) at (888) 297-4700, and if appropriate we will include it in our next revision. Lucent Technologies accepts no responsibility for errors or omissions contained herein.

Iwatsu ADIX / ADIX M Confidential Page 2 Ordering Information Octel 50 integration will support up to 16 ports. 2.0 ORDERING INFORMATION This integration supports up to 16 Octel 50 ports. For installed systems that have port capacities above 16 ports contact your CAG representative for the proper solution. Voice Boards supported: Dialogic DIALOG/4 Optional Fax Boards supported: Brooktrout TR114 Series Universal Port Optional Remote Service External Modem PBX hardware requirements For ADIX 3.0 PBX HARDWARE REQUIREMENTS FOR ADIX Single Line Subscriber Card (IX-8SUBS, IX-SUBS-1 or IX- SUBS-2) (IX-SUBS-1or IX-SUBS-2 can provide drop in loop current for disconnect.) For IX-SUBS or IX-SUBS-1 you will need a minimum of 2 IX4RCVS DTMF Receiver cards. (this will provide 8 DTMF receivers.) Ring Generator IXRNGU PBX hardware requirements For ADIX M PBX HARDWARE REQUIREMENTS FOR ADIX M Single Line Subscriber Card IX8SUBS-2 Ring Generator RNGU-M PBX software requirements 3.2 PBX SOFTWARE REQUIREMENTS ADIX 16 bit processor 4.20 to 4.50 ADIX 32 bit processor 5.20 to 5.50 ADIX 32 bit processor ACD 1.52 to 2.10 ADIX M 4.20 to 4.50 Additional Material Requirements 3.3 ADDITIONAL MATERIAL REQUIREMENTS The voice board used to interface Octel 50 VoiceMail is a four-port board. System configurations may reflect partial use of a board. The board used to interface Octel 50 FaxMail is a two-port board. You will need: One RJ-14 jack with 4-conductor line cord for every two Octel 50 ports. For optional remote service access: One analog line

Iwatsu ADIX / ADIX M Confidential Page 3 One RJ-11 Jack for above and 2-conductor modular telephone cord. If optional FaxMail is installed: One analog line per fax port One RJ-11 jack for every Brooktrout TR114 fax port Supported integration features 4.0 SUPPORTED FEATURES [] Items are supported System Forward to Personal Greeting Message Waiting All Calls [] LCD Display [ ] Ring/no answer [] LED [] Busy [] Lamp 1 [] Busy/No Answer [] Audible / Stutter Dial Tone [ ] Do Not Disturb [ ] Multiple Return to Operator [] Station Forward to Personal Greeting Direct Call 2 [] All Calls [] Auto Attendant [] Ring/no answer [] Outcalling [] Busy [] Personal Greeting of Original-Called Party Busy/No Answer [] Multiple Call Forward [] Do Not Disturb [ ] Double Call Forward [ ] Flexible Forwarding Call Coverage [ ] Forward to No Answer Greeting [ ] Intercom Paging [ ] Forward to Busy Greeting [ ] Supervised Transfers 3 Intercom/CO Forwarding [ ] Call Screening 4 [] Call Queuing [] Intercom Paging [ ] Record Telephone Conversation [ ] Notes: 1 See Section 7.1 4 See Section 7.4 2 See Section 7.2 3 See Section 7.3 4.1 DISCONNECT TYPE Disconnect is achieved via programmable hang-up string or Drop in Loop current. For proper external disconnect supervision, Ground start trunks or Supervised loop start CO lines are recommended. (See section 3.0). Programming PBX system parameters 5.0 CONFIGURING THE ADIX / ADIX M Define the DTMF Packet timers and Disconnect type DTMF Packet Speed Element: 10 Data: 4 (Sets the DTMF packet speed to 150 ms on and 50 ms off) In-Packet Pause Time Element: 11 Data: 0

All references to Octel 50 pertain to the entire family of products Iwatsu ADIX / ADIX M Confidential Page 4 (Sets the pause time before the packet is sent to 0 seconds.) Pre-disconnect packet Pause Time Element: 12 Data: 1 (Sets the pause time before disconnect to 1 second.) Disconnect Signal Type Element: 13 Data: 0 = disconnect by packet (see note: section 7.3) or Data: 1 = disconnect by loop open (IX-8SUBS-1 and 2 only) (Sets the type of disconnect) Loop Open Duration (set only if using loop open disconnect) Element: 15 Data: 70 (Sets Loop open time to 700 ms.) DTMF Packet Programming AA/VM Packet Code Class 04, Item 77 Elements: 01-20 Valid packets are up to 4 digits (0-9, *, #) Packets 5 through 12 deal with all the different forwarding conditions. They are very flexible and can be used in many ways. For this example, we have set them all to 7 so that the ADIX will send the Octel 50 a 7 for all the different forward conditions. In the Octel 50 setup we have Code to Go To Voice Mail set as 7. Define the following Elements: Element 05 = 7 Element 06 = 7 Element 07 = 7 Element 08 = 7 Element 09 = 7 Element 10 = 7 Element 11 = 7 Element 12 = 7 (consultation hold recall to VM) (ICM call to Mailbox forwarded to VM) (CO call xfered to Mailbox forwarded to VM) (ICM xfered to Mailbox forwarded to VM) (CO call forwarded to VM) (ICM call forwarded to VM) (CO/ICM camp on recall to VM on No Answer) (CO/ICM camp on recall to VM on Busy) Elements 11 and 12 can be used to forward calls to a No Answer or Busy greeting by setting them to send a unique code. IE: Element 11 = 5 and Element 12 = 6. This would send the Octel 50 a 5 plus the extension number for a ring no answer, and a 6 plus the extension number for a busy. This should be set up as customer needs dictate.

All references to Octel 50 pertain to the entire family of products Iwatsu ADIX / ADIX M Confidential Page 5 Element 13 = 8 (Sets packet for Auto login/direct Call to 8) (ICM call to VM to retrieve a message) Element 19 = 55** (CO/ICM disconnect packet.) (Sets disconnect packet. Use Element 19 only if is set to 0 to disconnect by packet.) Note: All of the Forwarding, Direct Call and Disconnect packets are programmable, we recommend 7 for Forwarding (Elements 5 through 12), 8 for Direct Dial (Element 13) and 55** for the Disconnect (Element 19). The integrator module reflects these recommendations. Define the Message Waiting Light Codes Message Waiting Cancel Code Class 7, Item 06 Element 1 Data: 501 (ADIX default for MWL cancel) Message Waiting Set Code Class 7, Item 06 Element 19 Data: 519 (ADIX default for MWL set) Configuring Octel 50 Ports 5.1 CONFIGURING THE OCTEL 50 PORTS Define all Octel 50 Ports Port Definition Class 01, Item 03 Data: 0-4-1-nnn (nnn = Logical Port Number) Valid Range = 0-4-1-001 through 0-4-1-448 (Defines the Logical Port Numbers as Voice Mail Integration ports.) Define the type of Voice Mail Integration for ports. Port Configuration Class 01, Item 04 Data: 0 (Sets the Voice Mail Integration ports to VM/AA) Assigning Extensions to Hunt Group 5.2 ASSIGNING OCTEL 50 EXTENSIONS TO HUNT GROUP Define the Hunt Group Access Number. Hunt Group Access Number Class 07, Item 02 Element: 47-50 (These hunt groups are reserved for AA/VM

Iwatsu ADIX / ADIX M Confidential Page 6 Element 47 use only) Data : 400 Access Number Range = Up to 4 digits (0-9, *, #) (Programmable code/number that is used to access the hunt group. For this example we will use access code 400 programmed to Element 47.) Define Ports designated as VM/AA in Class 1, Item 04. Hunt Group - Station Class 08, Item 02 Element: 47-50 Element 47 = VM/AA Hunt Group No. 47 Element 48 = VM/AA Hunt Group No. 48 Element 49 = VM/AA Hunt Group No. 49 Element 50 = VM/AA Hunt Group No. 50 Element 47 Data : (Enter the logical numbers of the Voice Mail Ports designated VM/AA in Port Configuration Class 1, Item 04.) Range = 001-448 (This is where you define the logical ports that you wish to assign to the hunt group that you will access by dialing, in this example, 400. The hunt group used in this example is 47.) Configuring the Subscribers Stations 5.3 CONFIGURING THE SUBSCRIBERS STATIONS Assign Fixed Call Forward as needed. Fixed Call Forward Mode Class 10, Item 73 Element : 1 Data : 0 = All Calls: 1 = Busy/No Answer: 2 = No Answer Note: If you program forward All Calls to a station it will never receive calls. Forwarding set from a phone overrides any fixed call forwarding. Configure the Fixed Call Forward Destination Fixed Call Forward Destination Class 10, Item 78 Element : 1 Data : Extension number or Hunt Group Access Number.

Voice Mail System programming Iwatsu ADIX / ADIX M Confidential Page 7 6.0 CONFIGURING THE OCTEL 50 During the install process, run the Integrator program and choose the Iwatsu ADIX / ADIX M. The Integrator will place appropriate feature codes into the Octel 50 Setup. The integrator inserts the following codes with three digit extensions assumed. Adjust to match site requirements. Outside Line Access Code 9, Off Hook Delay (OFFHDLY) 25 Hook Flash Interval (FLINTVL) 50 DTMF Tone Length (TONELEN) 8 Message Waiting Parameters Permit Message Waiting Lights Enabled Message Waiting Light Prefix ON 519 Message Waiting Light Prefix OFF 501519 Light Message Waiting Light for Every Message Enabled Hangup Detection Parameters Hangup String (HANGUPSTR) 55** Hangup String Timeout (HANGUPDLY) 100 Inband Parameters Total Number of DID Digits 4 DID Terminating Character (blank) Seconds to Wait for DID 1 Location of Inband Signaling Code 1 Number of Milliseconds to Wait for Digits 750 Code for Go to Voice Mail 7 Start at End of String for Go to Voice Mail Enabled Location of Mailbox Number for Go to Voice Mail 3 Code for Immediate Subscriber Login to Mailbox 8 Start at End of String for Immediate Login Enabled Location of Mailbox Number for Immediate Login 3 Start at End of String for Default Code Enabled Location of Mailbox Number for Default Code 3 Note: Verify these dialing sequences for your PBX 6.1 CCA PROGRAMMING CONSIDERATIONS CCA must be run manually to a station. To run CCA manually set Channel IN to 0, leave Channel OUT as it is, enter a physical extension number in the Phone Number field. It is best to use the extension of a phone that is next to you as you will be asked to make the phone busy, let the phone ring and answer the phone etc. Make sure the extension you are

Iwatsu ADIX / ADIX M Confidential Page 8 using does not have hands free announce or any type of call forwarding active. Important notes concerning this integration 7.0 CONSIDERATIONS/ALTERNATIVES The following items should be considered, below: MWL To Single Line Phones Direct Call / Auto Login Supervised Transfers Call Screening 7.1 MWL/ LAMP TO SINGLE LINE PHONES In order to provide Message Waiting lamps to Single Line phones you will need a IXDC-8. The IXDC-8 supplies 90 volts message waiting voltage to the Single Line phones. Message Waiting Lamps to a Single Line phone require an additional wire pair, one pair to the phone and the other pair is used to light the Message Waiting Lamp. 7.2 DIRECT CALL / AUTO LOGIN Direct Call / Auto login will only work when the MSG key is lighted. To retrieve a message from an extension with the MSG key lighted you must: Go off hook; Press the MSG key then press #. To retrieve a message from an extension with the MSG key not lighted you must: Dial the main pilot hunt group number; Press the # sign then enter the mailbox number. 7.3 SUPERVISED TRANSFERS If the Octel 50 is programmed to execute a supervised transfer, Handsfree Announce must be disabled. If you are using supervised, transfers the caller and the called party will hear beep tones when the call is connected or cut through. Also it has been noticed that on some systems the prompts, such as I m sorry there is no answer at that extension..., tend to get the first words clipped off. 7.4 CALL SCREENING If you wish to use, call screening it is recommended that you use packet 19 to disconnect instead of Drop in Loop current. On call screening Reject and Redirect with Drop in Loop current, if the called party hangs up the phone before the system performs a hook flash to get the caller back, the caller will be dropped.

Iwatsu ADIX / ADIX M Confidential Page 9 *Trademark of Iwatsu America, Inc. DIALOG/4 is a registered trademark of Dialogic Corporation Brooktrout TR114 Series Universal Port registered trademark of Brooktrout Technology A BROOKTROUT COMPANY Copyright 1995-2000 Octel Corporation, a subsidiary of Lucent Technologies Inc. All rights reserved. All trademarks identified by the and are registered trademarks or trademarks respectively of Octel Corporation, a subsidiary of Lucent Technologies. All other trademarks are the properties of their respective owners. The above information is based on knowledge available at the time of publication and is subject to change without notice. Printed in the United States Lucent Technologies Inc. 1001 Murphy Ranch Road Milpitas, CA 95035-7912 1-800-444-5590 Www.lucent.com/Octel Lucent Technologies, USA +408 324-2000 Lucent Technologies, Canada +1 416 730-8700 Lucent Technologies, Europe, Middle East, Africa +44 (0) 1252 303 000 Lucent Technologies, Central America, Latin America +1 408 324-3372 (USA) Lucent Technologies, Asia Pacific +65 430 2100 (CFN 77105)