Hazardous Area Protection

Similar documents
Session Two: Effective Surge Protection Installation

Operating Instructions

Lightning and Surge Protection for PV Systems

NEW NEW NEW NEW NEW NEW Electrical specification ESP SL06 ESP SL15 ESP SL30 ESP SL50 ESP SL110 ESP SL TN

Lightning Current Equipotential Bonding SPDs

Intrinsically Safe Barriers

LIGHTNING PROTECTION of SCADA AND TELEMETRY SYSTEMS

Introduction to Surge Protection

MANUAL Surge Protectors

Novaris Global Solutions in Lightning and Surge Protection PRODUCT HANDBOOK PRODUCT HANDBOOK Global Solutions in Lightning and Surge Protection

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

Type Code No. Weight Packaging [g] [pcs]

Surge Protection Devices Ex9UE2

2 Principle of lightning protection

SPM Series. Plug-in Surge Protection

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Systems which use a conventional POTS subscriber line to dial a compatible system and transfer digital data.

Safety instructions Overvoltage protection B81-35

DBPApplication. PD Devices Ltd. Unit 1, Old Station Yard, South Brent, Devon. TQ10 9AL (0)

Remote telecom site protection

SPM Series Plug-in Surge Protection

Surge Protection for Surveillance Systems

Zener Barriers Bulletin 937Z

Easy installation automatic earthing with simple DIN-rail mounting. Ultra-slim space-saving design

MTL8000-2/x Series Modular I/O

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Data Sheet. Surge protection devices - A technical overview

10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits

FLEX Ex Spring Clamp Terminal Base

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

PHOENIX CONTACT - 12/2007

SURGE PROTECTOR. lighting. for.

IECEx Certificate of Conformity

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

NTS-protect. Description of GPS antenna and NTS time server connection via system lightning protector system /NTS-3000, NTS-4000, NTS-5000/

Commercial and Industrial LV Power Protection

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

Overvoltage Protection Devices

PHOENIX CONTACT - 01/2008

/60 ETITEC A 15/ /60 ETITEC A 15/440 Al/Fe connection*

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

MDP and FDB lightning barriers Safety for data and control systems in plants and industrial and potentially explosive

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Solving High Performance Circuit Protection Needs in Space-constrained, High Density Electronics

Data & signal protection ESP D & TN Series

Tel: Web: Lightning and surge protection help pages

PI-EX-ME-2NAM/COC-24VDC

INTRODUCTION LIGHTNING MAGNITUDE AND FREQUENCY

Company Profile Surge Protective Devices

Installation & Operation Manual

Installation & Operation Manual

Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections

Application Note TAN MTL Surge Technologies. Lightning surge protection for electronic equipment - a practical guide.

Surge & Filter Protection Addressing your industrial power quality needs.

Overvoltage Protection

ELPROMA NTSprotect Surge Protection

LPI PRODUCT Summary Brochure

APPLICATION GUIDE. Interface Modules IM Series.

FILTERS FOR DATA LINES

M E M O R A N D U M I.S.

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

Solutions for Fossil Fuel Energy

BLITZDUCTOR XTU Universal lightning current / surge arrester

AC Surge Protection Devices

ITU-T Recommendations and the Resistibility of Telecommunication Equipment

PI-EX-ME-2NAM/COC-120VAC

The Solid-State Decoupler (SSD)

2U Congestion Alert Rack Insert for UK

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

MTL SD range Ultra-slim user-friendly devices for protecting electronic equipment and systems against surges on signal and I/O cabling.

technical datasheet SD Series

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Interface and Supply module. IPC 3x0i / PSC 3x0i

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

5 Fieldbus Technology

IECEx Certificate of Conformity

Retrofitting sewage plants with lightning and surge protection measures

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

About the FLEX Ex I/O Systems

17 th Edition (BS 7671:2008) incorporating Amendment No 1

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR RJ CONNECTION. DEHNlink Surge arrester

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Fundamentals of Thyristor Overvoltage Circuit Protection

Overvoltage Protection

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

ITU-T K.118. Requirements for lightning protection of fibre to the distribution point equipment SERIES K: PROTECTION AGAINST INTERFERENCE

Test Report S

technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur

M-series Intrinsically Safe I/O

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

GLOSSARY OF TERMS. Surge and Lightning Protection ERICO Inc.

Transcription:

Hazardous Area Protection Global Solutions in Hazardous Area Surge and Lightning Protection

Intrinsic Safety When instrumentation is installed in a potentially explosive environment steps must be taken to ensure that there is no possible way a spark could cause ignition and hence an explosion of the gas, powder or dust that makes up the explosive atmosphere. One way of ensuring this is to limit the available electrical energy in the explosive environment to levels below which ignition can take place. This technique is called intrinsic safety (IS). This is achieved by placing an energy limiting IS barrier at the boundary between the safe area (non explosive) and hazardous area (explosive). Then all equipment in the hazardous area must be approved for connection, or be defined as simple apparatus. These IS barriers and field instruments are just like any other pieces of electronics susceptible to damage from surges and transients due to power faults or nearby lightning strikes. The Novaris range of IS surge protectors and IS instrument protectors are certified for connection in IS circuits on the hazardous side the IS barrier and directly to instruments located in hazardous or explosive environments. They provide effective protection to the IS barriers and field instruments.

The Novaris Systematic Approach Lightning strikes are an unpredictable natural phenomenon. However the way equipment can be protected from lightning strikes is predictable. The Novaris Systematic Approach is a step-by-step solution to lightning and surge protection that can be applied to any application. 1 2 3 4 5 Define Boundaries Boundaries divide areas of different potential. Protect Structure Novaris supports conventional lightning protection methods. Install Bonded Earthing System A single bonded earthing system within each boundary is essential. Protect Power Lines Protect all power lines crossing protection boundaries. Protect Signal/Data Lines Protect all signal/data lines crossing protection boundaries. Novaris offers: Investigation and Analysis - a complete package from analysis of your existing lightning and surge protection system to providing complete recommendations based on site surveys and technical analysis. Structural Lightning Protection and Earthing Systems - design and advice on lightning protection systems for all structures in accordance with recognised world standards. - supply of structural lightning protection and earthing components. A Comprehensive range of Surge Protection Products to suit any application - ranging from main switchboard and distribution board surge protection, PLC and control system protection, to RF coaxial protection. Custom Product Design - our innovative R&D team can engineer a surge protection solution for even the most demanding of applications. Project Management & Installation - Novaris actively seeks consultancy, project management and installation work. Our experience extends from Australia to the Pacific, Asia, Africa and the Middle East. 1

The Novaris Intrinsically Safe Surge Protection Why do I need surge protection? Surge protection is often overlooked during design and installation phases of process control systems. Experience shows that emphasis is placed on the installation of lightning protection systems with the philosophy that this will protect not only the structure, but the process control system installed. This has often been disproven by failure and damage to equipment in a process control system as a result of a indirect cloud-to-ground lightning strike many kilometres away, despite the installation of a lightning protection system. Often long, underground signal cabling connecting field instruments to the process control instrumentation create potential difference and transient inductions into the cabling all play a part in the effect of indirect lightning strikes. Therefore, the importance of surge protection must be stressed. Awareness of this often takes place after extensive damage to process control systems. In addition, surge protection must be recognised to only provide protection to connected equipment in close proximity. For example, protection fitted to equipment at one end of a cable run will not provide protection to the equipment on the other end. This must be taken into consideration when installing or specifying surge protection. Novaris Intrinsically Safe Surge Protection Novaris have designed surge protection devices specifically for Intrinsically Safe (IS) applications. Novaris products with the IS- prefix have all been certified in accordance with the requirements of the IEC Ex scheme by an authorised certification body. Every Novaris intrinsically safe surge protection device has the group IIC T4 certification making it acceptable for use with all gas/air mixtures. Novaris IS surge protection devices provide surge protection on IS circuits only. They do not take the place of the IS barrier. For complete technical specifications or to view the certificate of conformity for the Novaris intrinsically safe range of surge protection devices please visit www.novaris.com.au. 2

Intrinsically Safe Signal Line Protectors Novaris slimline surge protection devices (SPDs) provide surge protection for most twisted pair signaling schemes. Certified to be intrinsically safe Novaris IS SPDs can be installed in the hazardous zone or the field side of the IS barrier. This not only provides protection for the PLC or RTU I/O, it also provides protection for the IS barrier. The multistage, failsafe design features a high energy gas discharge tube (GDT) as primary protection plus series impedance and secondary components that provide very robust surge protection with high transient suppression offering low let-through voltages. At only 7mm wide, the Novaris Slimline Signal Line Protectors offer ease of retro-fit installations by conveniently replacing an existing pair of standard 4mm wide terminals with room to spare. This simplifies the installation into marshalling cabinets, greatly reducing down time. The plug-in design of the Novaris slimline signal line protectors provides simple and rapid replacement and testing - no rewiring needed. This also provides a convenient method of field equipment isolation if required. Novaris slimline signal line protectors easily clip onto standard 35mm DIN rail. The base provides a secure, low impedance earth connection to the DIN rail, essential for effective surge protection. In addition, screw terminals are also provided for additional earth connection. Two base options are available for different applications: G base connects directly to the mounting DIN rail for the most effective, low impedance earth connection. EC90 base connects to the mounting DIN rail through a high-energy gas discharge tube (GDT) connected to provide isolation under normal conditions. During a surge, the GDT provides equipotential bonding between the earth screw terminals and DIN rail earth connection; avoiding possible earth loops. 3

Intrinsically Safe Signal Line Protectors IS-SL Intrinsically Safe Signal Line Protectors The IS-SL range provides protection to most analogue and digital interfaces. Commonly analogue inputs and outputs are the most susceptible to damage from surge and transients induced onto the signal lines. The IS-SL range is designed exclusively for low current applications less than 350mA. For applications requiring a higher current rating Novaris recommend the IS-SSP6A range. The Novaris IS-SL range can are suitable for both input and output applications. IS-SL7V5 IS-SL18 IS-SL36 IS-SL420 Electrical Specifications Maximum continuous voltage (DC) U 0 7V 16V 34V 34V Maximum continuous voltage (AC) U c 5V 11V 24V 24V Primary GDT rating 8/20µs 10kA Maximum load current I L 350mA 30mA Signal Type Marshalling Cubicle # Field / Remote # 0-5V analogue IS-SL7V5-G IS-SL7V5-EC90 0-10V analogue IS-SL18-G IS-SL18-EC90 5V digital IS-SL7V5-G IS-SL7V5-EC90 12V digital IS-SL18-G IS-SL18-EC90 24V digital IS-SL36-G IS-SL36-EC90 0-20mA analogue IS-SL36-G / IS-SL420-G IS-SL36-EC90 / IS-SL420-EC90 4-20mA analogue IS-SL36-G / IS-SL420-G IS-SL36-EC90 / IS-SL420-EC90 High-speed data applications are catered for with the IS-SL485 and IS-SLDH models feature operation up to 20MHz. The IS-SL485 is ideal for applications such as RS485 serial communication and protocols such as Profibus and CAN. Similarly IS-SLDH is designed for other high speed protocols such as Data Highway and Data Highway Plus. Typically, these models are used in conjunction with the EC90 base to provide isolation from earth. IS-SL485 IS-SLDH IS-SL-RTD Electrical Specifications Maximum continuous voltage (DC) U 0 7V 34V 7V Maximum continuous voltage (AC) U c 5V 24V 5V Primary GDT rating 8/20µs 10kA Maximum load current I L 500mA 350mA Signal Type Marshalling Cubicle # Field / Remote # RS485 IS-SL485-G IS-SL485-EC90 Profibus DP IS-SL485-G IS-SL485-EC90 CAN IS-SL485-G IS-SL485-EC90 Data Highway IS-SLDH-G IS-SLDH-EC90 RTD applications IS-SL-RTD-G IS-SL-RTD-EC90 For complete and updated technical specification sheets go to www.novaris.com.au 4

Intrinsically Safe Series Surge Protectors IS-SSP6A Intrinsically Safe Series Surge Protectors The IS-SSP6A intrinsically safe series surge protectors complement the IS-SL range for applications of load currents up to 6A. Typical applications may include power supplies, digital outputs and other low voltage requirements up to 6A. The design of the Novaris IS-SSP6A range include high energy metal oxide varistors. The series connected design eliminates the effect of connection leads inductance encountered with shunt connected surge protectors. IS-SSP6A-14 IS-SSP6A-26 IS-SSP6A-38 Electrical Specifications Maximum continuous voltage (DC) U 0 14V 26V 38V Maximum continuous voltage (AC) U c 11V 20V 30V Maximum discharge current 8/20µs I max 9.6kA Maximum load current I L 6A Signal Type Marshalling Cubicle # Field / Remote # 12VDC IS-SSP6A-14-G IS-SSP6A-14-EC90 24VDC IS-SSP6A-26-G IS-SSP6A-26-EC90 36VDC IS-SSP6A-38-G IS-SSP6A-38-EC90 Accessories SL Test Plug SL-TEST Novaris SL Test Plug provides access to field and equipment terminals plus earth via mini banana sockets mounted in the top face of the test plug. It provides a convenient way to connect to these lines for testing. This is defined as a simple apparatus. SL Earth Comb SL-COMB The Novaris SL Earth Comb provides a convenient means of connecting the common points of SL series surge protectors. The earth comb contains nine contacts, allowing banks of 8 SL protectors to be commoned together with one overlapping contact. The earth comb can be cut to provide a lesser number of points. The earth comb contains two 6.3mm spade terminals. # Typical application For complete and updated technical specification sheets go to www.novaris.com.au 5

Intrinsically Safe Instrument Protectors Novaris threaded instrument protectors provide surge protection for most twisted pair signalling schemes. Certified to be intrinsically safe Novaris threaded instrument protectors are designed to be installed directly at the field equipment providing protection against induced surges and transients. The multistage design provides a high energy gas discharge tube (GDT) as primary protection for common mode disturbances, commonly associated with lightning strikes and power system earth faults and a secondary metal-oxide varistor clamping stages across the signal lines. This combination provides very robust surge protection with high transient suppression and low let-through voltages where needed. In addition protection is provided for cable screens which may be open circuit at the instrument. All Novaris IS instrument protectors are unique in that comply with the IEC 500V insulation breakdown requirement. This obviates the need for an additional earth bonding conductor between the instrument and the IS barrier earth. The threaded enclosure provides an easy installation by directly screwing into a free cable entry on the instrument. Common thread types such as M20 x 1.5, ½ NPT and ¾ NPT threads are accommodated for. Other threads are available by request. All Novaris threaded instruments are certified intrinsically and their enclosures explosion proof so may be installed in Ex d rated instruments without loss of integrity. Thread Type Thread Code M20 x 1.5 -M20 1/2 NPT -N12 3/4 NPT -N34 6

Intrinsically Safe Instrument Protectors IS-SLT1 Intrinsically Safe Instrument Protector The IS-SLT1 range provides protection for most single twisted pair signalling schemes. The units are shunt connected to the terminals and hence do not interrupt or interfere with the signal. Therefore, the IS-SLT1 range can be adapted to most instruments. Typical applications are analogue and digital instrument transmitters. IS-SLT1-7V5 IS-SLT1-18 IS-SLT1-36 Electrical Specifications Maximum continuous voltage (DC) U 0 7V 16V 34V Maximum continuous voltage (AC) U c 5V 11V 24V Primary GDT rating 8/20µs Signal Type 10kA Novaris Product 0-5V analogue IS-SLT1-7V5 0-10V analogue IS-SLT1-18 5V digital 12V digital 24V digital 0-20mA analogue 4-20mA analogue IS-SLT1-7V5 IS-SLT1-18 IS-SLT1-36 IS-SLT1-36 IS-SLT1-36 IS-SLT3 Intrinsically Safe Instrument Protector The IS-SLT3 range provides protection to most three-wire signalling schemes. The units are shunt connected to the terminals and hence do not interrupt or interfere with the signal. Therefore, the IS-SLT3 range can be adapted to most instruments. Applications may include instruments which are field powered with a single wire control signal. In addition, the IS-SLT4-RTD is specifically designed for resistive temperature detectors (RTD) such as PT100 types. This unit caters for all two, three and four wire RTD systems. IS-SLT3-7V5 IS-SLT3-18 IS-SLT3-36 IS-SLT4-RTD Electrical Specifications Maximum continuous voltage (DC) U 0 7V 16V 34V 7V Maximum continuous voltage (AC) U c 5V 11V 24V 5V Primary GDT rating 8/20µs 10kA For complete and updated technical specification sheets go to www.novaris.com.au 7

Intrinsically Safe Instrument Protectors SLT-Y Adapter Where a field instrument has no free cable entry Novaris can supply a Y-piece adapter to accommodate the threaded instrument protector and cable gland. The SLT-Y is available in the same thread types as the threaded instrument protectors. Thread Type Adapter Type M20 x 1.5 SLT-Y-M20 1/2 NPT SLT-Y-N12 3/4 NPT SLT-Y-N34 IS-LCP Intrinsically Safe Load Cell Protector The IS-LCP provides protection for both 4-wire and 6-wire loadcells as well as the measuring instrument. The LCP is contained within an IP65 enclosure, or alternatively it may be supplied as an assembled PCB. As well as having IS certification the IS-LCP is certified for installation into a loadcell circuit without affecting calibration. IS-LCP-18 IS-LCP-36 IS-LCP-18-PCB IS-LCP-36-PCB Electrical Specifications Maximum continuous voltage (DC) U 0 18V 36V 18V 36V Maximum discharge current 8/20µs I max 250A Lines protected 4 or 6 For complete and updated technical specification sheets go to www.novaris.com.au 8

Surge and Lightning Protection Power Protection - Surge Diverters Novaris provides a wide range of surge protection solutions to suit most industrial applications. All Novaris products comply with the relevant International and Australian standards. We manufacture shunt connected surge diverters (one port SPDs) and series connected surge filters (two port SPDs) that may be configured for any LV power distribution system worldwide. Power Protection - Surge Filters Novaris manufactures surge protection devices for signal processing, data transmission, and telecommunications applications. We specialise in the design, manufacture and installation of specialised protection solutions. With our team of experienced engineers we can provide advice across a wide range of industries. Process Control Protection For a complete listing of all Novaris products refer to The Novaris Product Handbook or visit www.novaris.com.au. LAN & CCTV Protection Coaxial Protection Telephone Protection Due to the Novaris policy of continuing product development, specifications are subject to change without notice. 9

Novaris Pty Ltd 72 Browns Road Kingston P.O. Box 2010 Kingston Tasmania 7050 Australia Telephone: +61 3 6229 7233 Facsimile: +61 3 6229 9245 Email: sales@novaris.com.au Web Page: www.novaris.com.au Copyright 2009