KNX DALI Gateway Plus - User Manual

Similar documents
1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

Operating Instructions. DALI-Gateway

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

Product documentation

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions

Operating and mounting instructions

Product and functional description

1 Safety instructions. 2 Device components. 3 Function. DALI transformer W. Art.-No.: D SNT 105. Operationsmanual

LED DMX WiFi Controller Touch RGBW 4 Zonen - User Manual

picture 1: Device components

The LED display (1) turns green when the load is switched on.

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Operating Instructions. Power-DALI-Potentiometer

LED DMX/RDM Decoder - RGBW (4CH) - User Manual

DALI Professional Controller-4. Control unit Operating instructions

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Product and functional description

Lighting Control System for Indoor Applications LIGHT CONTROLLER L LIGHT CONTROLLER L

picture 1: Device components

Figure 1: Device components

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

OT EASY 60 II. LED control unit Operating instructions

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

Product and functional description

Light Control SLS ADRIA

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Contents. GAMMA instabus Application program description. August 2017

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Product and functional description

1-channel shutter actuator 6A UP Installation Instructions

Operating instructions

Product and functional description

Lighting Control System for Indoor Applications LIGHT CONTROLLER LW RADIO-OPERATED VERSION ENOCEAN RADIO-OPERATED CONTROLLER

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Manual and application description KNX/EIB LED driver V2.0

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

Operating Instructions

Blind actuator 4-gang 230 V AC Order-No

Push Button Interface UP 220D31

Data sheet. Function description. Benefits

Product documentation

Product documentation

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

4-gang and 8-gang switch actuator 16A C-load SE

PRODUCT MANUAL. ABB i-bus KNX DG/S x DALI-Gateway Basic

1 Safety instructions. 2 Device components. KNX Touch/Glass sensor comfort

Product documentation

The output variables can be force-controlled from a coordinating control system.

Bus coupler 3 Bus coupler 3 external sensor Order No

Product and functional description

Connections, displays and operating elements

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

MTN MTN

Product manual. Mylos KNX 350w Dimmer 2CSYK1205C/S

KNX/EIB Product documentation. Issue:

4 CHANNEL UNIVERSAL DIMMING ACTUATOR

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Operation and installation manual KNX IP LineMaster 762 (Art. # 5212) KNX Power supply with integrated KNX IP Router and diagnosis functions

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

UNIVERSAL DIMMER DIM02SA/500U

Installation and User Guide

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Power Supply System KNX PS640-IP

Tebis application software

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Technical Manual. DALI GATEWAY Art A

/ 2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. Room temperature controller with display 6108/18-500

DELTA profil wall switch, single UP 241/2 5WG AB_2

Power Supply Systems KNX PS640 and KNX PS640 USB

System Installation guide

Application description

Description TR D

PX175. DMX-DALI Converter MANUAL

1 Safety instructions. 2 Device components. Smart Panel. Art.-No.: SP 9 KNX. Operating instructions

DALI Link User Manual

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Product and function description

PSR UC/ESAM4/3X1/1X2/B

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

Operating instructions Memory plug E /02 11/2011

DALI Installations Application AEL-DALI

Manual and application description 4 channel 0-10V dimmer V2.0

Technical Manual MDT DaliControl IP Gateway w/ Webinterface

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Four-channel Venetian blind actuator 230 V Installation Instructions

Operating instructions. Monitor FS-2 / FS-2N / / 2013

SAVE THESE INSTRUCTIONS

Transcription:

KNX DALI Gateway Plus - User Manual Item No.: LC-013-064 1. Product Description The KNX DALI gateway Plus is the interface between the KNX installation and the DALI lighting system. It allows up to 64 DALI devices in a maximum of 32 groups to be switched and dimmed via the KNX system. Can be used as a DALI master and power supply for DALI devices. To switch and control ECG and Tronic transformer with DALI interface. Brightness or lighting error can be read out via KNX. 2. Specification Power supply rated voltage KNX Operating voltage KNX Power input DALI Voltage max. wire cross-section Dimensions (L x W x H) weight DC 110-240V 29V (21-32VDC) 150mA 16VDC (9,5-22,5VDC) 4mm² 72 x 90 x 70 mm 154g 3. Description 1. Control of up to 64 DALI devices in up to 32 groups 2. Individual, group or central addressing 3. Suitable for operation in emergency lighting systems 4. 16 light scenes 5. Effect control for dynamic lighting effects or colour games 6. Read out DALI device state via KNX, e.g. brightness or luminaire error 7. Manual operation of the DALI groups

8. Restraint 9. Feedback of switching state and brightness value in bus and manual mode 10. Collective feedback 11. Central switching function 12. Disabling function for each DALI group 13. Separate ON and OFF delay 14. Staircase lighting timer with run-on time 15. Corridor function: when combined with motion detectors, reduced continuous lighting, if no motion is detected 16. Online or offline project planning of the DALI devices with ETS plug-in 17. Short circuit protection 18. Surge protection 19. Overload protection 20. Operating hours counter 21. Signal of the global switching status of the DALI devices, e.g. to switch off the mains voltage of the DALI devices to avoid standby losses 22. An individual DALI device can be exchanged during operation without software. 4. Device components (1) Button field for manual operation (2) Programming button and LEDs (3) KNX connection (4) Display of DALI devices or DALI group (5) Connection for mains supply (6) DALI output

5. Operating elements (4) Display of DALI number (1...64)(4a) DALI group(4b) Individual DALI devices (7) Button Manual operation (8) LED On: Continuous manual mode active (9) ON/nbutton switch on or increase brightness (10) LED ON/n On: DALI device or group switched on, brightness 1...100 % (11) OFF/o button switch off or reduce brightness (12) LED OFF/o On: DALI device or group switched off, brightness 0 % (13) ALL OFF button Switch off all DALI devices In operation with the button field the device distinguishes between a short and a long press. Short: pressing for less than 1 second Long: Pressing for between 1 and 5 seconds Operating modes Bus operation: Operation via push-button sensors or other bus devices Short-term manual operation: Manual operation locally with button field, automatic return to bus operation. Continuous manual mode: Exclusively manual operation on the device i - No bus operation is possible in manual mode. i - No manual mode is possible in case of bus failure. i - After a bus failure and restoration the device switches to bus operation. i - After a power failure and restoration the device switches to bus operation. i - The manual mode can be disabled in ongoing operation via a bus telegram. Switching on the temporary manual control Operation using the button field is programmed and not disabled. Press the button briefly. Display (4) shows 01, LED remains off. - or - Display (4) shows bc: all connected DALI devices are controlled jointly. i - After 5 seconds without a button-press, the device returns automatically to bus operation.

Switching off temporary manual operation The device is in short-term manual mode. No button-press for 5 seconds. - or - Press button briefly as many time as necessary until the device leaves the short-time manual mode. The display (4) is off. Switching on permanent manual control Operation using the button field is programmed and not disabled. Press the button for at least 5 seconds. LED c is illuminated, display (4) shows 01, continuous manual mode is switched on. - or - Display (4) shows bc: all connected DALI devices are controlled jointly. Switching off permanent manual control The device is in continuous manual mode. Press the button for at least 5 seconds. LED is off, display (4) is off, bus operation is switched on. Operating DALI devices The device is in continuous or short-term manual mode. Press button briefly as many times as necessary until the display shows the desired DALI number. The LEDs ON/n and OFF/o indicate the status. Operate output with ON/n or OFF/o button.short: switch on/off.long: dim brighter/darker.release: Stop dimming. The LEDs ON/n and OFF/o indicate the status. i - Short-term manual operation: after running through all of the available DALI numbers, the device exits manual mode after another brief press. i - The display (4) firstly shows the numbers of the available DALI groups (4a), followed by the individu al addresses of the DALI devices (4b). Switch off all DALI devices The device is in continuous manual mode. Press the ALL OFF button. All DALI devices switch off. Disabling individual DALI devices or groups The device is in continuous manual mode. Press button briefly as many times as necessary until the display shows the desired DALI number. Status display via LEDs ON/n and OFF/o. Press ON/n and OFF/o buttons simultaneously for at least 5 seconds. The selected DALI number flashes in the display (4). DALI device or group is blocked. Activate bus mode (see section Deactivating permanent manual control). i - DALI devices blocked via manual operation can be operated in manual mode.

Unblocking a DALI device or group The device is in continuous manual mode. Press button briefly as many times as necessary until the display (4) flashes the desired DALI number. Press ON/n and OFF/o buttons simultaneously for at least 5 seconds. DALI device or group is enabled. The display (4) no longer flashes. Activate bus mode (see section Deactivating permanent manual control). 6. Wiring Diagram/ Fitting and electrical connection Observe the temperature range. Ensure adequate cooling. Mount device on DIN rail. Output terminals must be at the top. Control cable: appropriate type, cross-section and routing for the specifications for 250 V cables. DALI and mains voltage wires can be run together in a cable, e.g. NYM 5x1.5 mm². i - DALI participants from some manufacturers have expanded functions and can e.g. be controlled via mains voltage on the DALI connection. When existing DALI installations are refitted, remove all corresponding operator controls. i - The DALI control voltage is a functional extra-low voltage (FELV). When performing installation, perform the installation in such a way that when an area is disconnected the lines carrying both the DALI and also the mains voltage are disconnected. Connect device as shown in the connection example (Figure 3). If multiple miniature circuit breakers supply dangerous voltages to the device or load, couple the miniature circuit breakers or label them with a warning, to ensure disconnection is guaranteed. Connect bus line with connecting terminal. i - DALI devices can be connected to various phase conductors.

Operation in emergency lighting systems The device can be used in decentrally-powered or in centrally-powered emergency lighting systems. In decentrally-powered emergency light systems, emergency luminaires with individual batteries and special DALI devices are used. i - Observe the number of DALI devices in the emergency luminaires used. Emergency lighting systems with a central safety supply are required in buildings larger than 2000 m². Depending on the scope of functions of the system, only the emergency luminaires are supplied by the central safety supply (Figure 4), or the KNX system and DALI gateway are also supplied. In the latter case, in emergency operation, the DALI gateway can transmit the appropriate fault messages to a central system and other DALI gateways in the system. Emergency luminaires supplied through a central safety supply Emergency luminaires, KNX system and DALI gateway supplied through a central safety supply

Installing the cover It is necessary to install a cover to protect the bus connection against hazardous voltages in the connection area. Route the bus line towards the rear. Install cover on top of the bus terminal so that it snaps into place Removing the cover Press the cover to the side and pull it off Commissioning Load the address and the application software Switch on mains voltage. Switch on the bus voltage. Assign physical address and note on the device label. Commission DALI system using commissioning software. i - For more detailed information on commissioning of the DALI system, see the technical product information for this device. Load the application software into the device. i - No programming is possible if no mains voltage is connected.

7. Troubleshooting Display shows Er, connected DALI devices have no function, no operation possible Cause: Mains voltage on DALI cable. Installation error. Disconnect device and connected DALI devices from mains voltage and disconnect bus voltage. Correct installation. Display shows bc in manual mode, control of individual luminaires not possible. Cause: The device has not been programmed or is programmed to Broadcast. Check the device status. If necessary, program the device and put DALI system into operation. Individual DALI devices have no function Cause 1: Load is defective, e.g. lamp. Exchange load. Cause 2: DALI device is defective. Exchange defective device. Switch on voltage. Press and ALL OFF buttons together for at least 10 seconds. The device detects the exchanges DALI device and loads in the necessary data. The display (4) shows LE. i - Simultaneous exchange of multiple DALI devices is only possible with commissioning software and project data. None of the DALI groups can be operated. Cause 1: All DALI groups disabled via bus or manual operation. Cancel disabling. Cause 2: Continuous manual mode switched on. Switching off permanent manual control Cause 3: Application software has been stopped, programming LED is flashing. Perform reset: Disconnect device from bus, switch on again after approx. 5 seconds. Cause 4: Application software missing or faulty. Check programming and correct.

8. Safety warnings 8.1. To avoid installed the product in minefield, strong magnetic field and high voltage area. 8.2. To ensure the wiring is correct and firm avoiding short circuit damages to components and cause fire. 8.3. Please install the product in a well ventilated area to ensure appropriate temperature environment. 8.4. The product must be worked with DC constant voltage power supply. Please check the consistence of input power with the product, if the output voltage of the power comply with that of the product. 8.5. Connect the wire with the power on is forbidden. Ensure proper wiring first then check to ensure no short-circuit, then power on. 8.6. Don t repair it by yourself whenever an error occur. Contact the supplier for any inquiry. 8.7. Electrical equipment may only be installed and fitted by electrically skilled persons. 8.8. Serious injuries, fire or property damage possible. Please read and follow manual fully. 8.9. Danger of electric shock. Always disconnect before carrying out work on the devise or load. At the same time, take into account all circuit breakers that supply dangerous voltage to the device or load. 8.10.Danger of electric shock. Device is not suitable for disconnection from supply voltage. 8.11.The DALI control voltage is a functional extra-low voltage (FELV). On installing, ensure safe isolati on between KNX and DALI. 8.12.These instructions are an integral part of the product, and must remain with the end customer.