LogicMachine5 Power (LM5p-DW1)

Similar documents
LogicMachine5 Reactor IO V2

LogicMachine5. LogicMachine (LM) is your easiest way to program complex logic in KNX/EIB, Modbus, BACnet, DALI, 1-wire LM will enable you to

LogicMachine5 Reactor GSM

CANx / LoRa 433 MHz 8 x Analog inputs / Digital ouputs

Amati.linea Streaming Player light

DALI RS485 gateway. ENG - Data sheet Issue date Application

DALI RS485 gateway. ENG - Data sheet Issue date Application. Types of product. Standards and norms compliance.

DALI RS485 gateway. ENG - Data sheet Issue date Application

Manual and application description 4 channel 0-10V dimmer V2.0

User Manual. cmt-svr Startup Guide

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Manual and application description KNX/EIB LED driver V2.0

mark150s mark150/485s DDC controllers Summary

Operating and mounting instructions

DIRIS Digiware D and C Communication and control power interfaces

USER S MANUAL TP series

ABB i-bus KNX AC/S Application Controller

Industrial L2/L4 Managed Gigabit Switch. With 4-Port 802.3at PoE+ IGS P4T/IGS P4T2S. Quick Installation Guide

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

IMIO100 IMIO105. DDC controllers. Summary

USER MANUAL FOR GS100/GS1003G

Quick Start Guide. Industrial Managed Gigabit Ethernet PoE+ Switch LPH2008A-4GSFP

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Lighting Control Panel

Connections, displays and operating elements C D

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

User Manual. cmt-svr Startup Guide

Technical Manual MDT IP Router

Product and Applications Description

Contents 1. Summary

Technical Manual MDT IP Router

UR51 Industrial Cellular Router

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Product and Application Description

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

MU110-6U. Analog output module 6 channel. User guide

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

BACnet/IP to BACnet MS/TP Router

QUICK-START EMU M-BUS CENTER ENGLISH

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Connections, displays and operating elements

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

USER S MANUAL TP1043 series

IntesisBox Modbus Server KNX

RTU560 Remote Terminal Unit Connections and Settings

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

User Manual. cmt-iv5 Startup Guide

EnerSure Installation Guide

connecdim Gateway G1 Ethernet TCP/IP to DALI

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

584 5WG AB_1 DELTA

5-Port Industrial Ethernet Switch - DIN Rail Mountable

IntesisBox BACnet/IP Server DALI

Metaphase DDC-3. Technologies USER MANUAL. Version 7.X August metaphase-tech.com. pg. 1

F Series Indoor Fixed IP Camera. Quick Start Guide

IntesisBox KNX - BACnet/IP Client

Cimetrics, Inc. B6000 BACnet/IP to BACnet/MSTP Router. User Manual V.2

Gateway configuration manual IP - KNX EK-BE1-TP

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

BACnet/IP Web Interface

Installation and User Guide

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

FGC LON System. Technical Specification

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TN-5308 Quick Installation Guide

ProtoConvert Modbus RTU / Modbus TCP/IP / BACnet MSTP / BACnet IP / SNMP - Telnet (Lighting Controller) PG

IntesisBox Modbus Server - BACnet/IP Client

SCADALink IP100 SCADA Terminal Server QUICK START GUIDE Revision 1.42 June 19, 2012

ENGLISH KNXCONVERTER PARLEZ VOUS ASCII?

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

BAS Router BACnet Multi-Network Router

DomiOP ebis400 Series A new generation of Building HMI s. embedded building information system

Web interface BACnet/IP

Power Serial Device Server

Click! 301. Serial to Ethernet Converter

MED102A. Industrial Serial to Single-mode Fiber Converter

PR-WS Web SCADA device for Modbus RTU, Modbus TCP/IP, BACnet MSTP and BACnet IP with JSON/XML for remote Data Logging & Monitoring

Industrial 8-Port 10/100/1000T 802.3af/at PoE + 2-Port 100/1000X SFP Managed Switch with Wide Operating Temperature

Product and functional description

PG AB Omron FINS to Modbus RTU Protocol Converter

Quick Start Guide V5.0

Ethernet Interface Module

GW1000 User s Guide. Revision 1.04 Mar 30, 2008

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Buffered Power Supply PS-30DR v1.0

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

DMX2DALI. Setup Manual. e:cue lighting control An OSRAM Company Rev

Technical Manual Nova: Cabinet Security Management System (CSMS)

7NOX User Manual for Site Device. Book after-hours air conditioning in commercial buildings with ease.

INJ-24A Series Quick Installation Guide

MINI-PS AC/10-15DC/8

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

Transcription:

Embedded Systems SIA, VAT No LV40003411103 47. Katolu str., Riga, LV 1003, LATVIA Phone: +371 67648888, fax: +371 67205036, e-mail: sales@openrb.com LogicMachine5 Power (LM5p-DW1) LogicMachine (LM) is your easiest way to program complex logic in KNX/EIB, Modbus, BACnet, DALI, 1-wire networks. LM will enable you to efficiently customize building automation processes, easily delivering unlimited flexibility benefit to end users in a cost-effective way. LM5 Power is an embedded platform with integrated Ethernet, USB, KNX/EIB, DALI, 1-wire, Serial interfaces. LM allows to use it as crossstandard gateway, logic engine, visualization platform, IP Router. Scripting templates provides user-friendly, flexible configuration interface and integration with cloud/web services, 3 rd party devices. Via applying custom scripts LM can simultaneously act as thermostat, security panel, lighting controller, etc. LogicMachine application store and external app development possibility allows to extend device functionality and adjust to a specific market segment LM5 Power has Power-over-Ethernet support. Further, LM5 Power is 3x more powerful than all previous LogicMachine versions due to more powerful CPU and RAM. ENG - Data sheet Issue date 1.12.2016 1

Application Logical functions WEB SCADA visualization for PC and touch-devices cross-standard gateway integration with third party devices over USB, RS485 serial port, Ethernet AV, IR, HVAC Data logger with trends KNX IP Router Presence monitoring Lighting regulation Universal controller (lighting, shutter etc.) Health/activity monitoring Internet-of-Things Cloud server/client 2

Types of product LogiMachine5 Power LM5p-DW1 Standards and norms compliance EMC: PCT EN61000-6-1 EN61000-6-3 Certificate Technical data: Power supply: Power consummation: 1.3W 12V-30V DC on terminal connectors or 12V-30V DC Passive Power-over-Ethernet Interface: KNX/EIB TP1 1 10BaseT/100BaseTX 1 RS-485 1 RS-485/RS-232 1 (switchable in software full-duplex=rs232, half-duplex=rs485) DALI master 1-wire 2 2 (up to DALI 128 ballasts in total) Connections: KNX bus Bus Connection Terminal 0.8mm2 Power supply Screw, 1.5 mm2 Serial Screw, 1 mm2 DALI Screw, 1 mm2 1-wire Screw, 1 mm2 Operating elements LED 1 CPU load 1 - Activity Enclosure: Material: Polyamide Color: Gray Dimensions: 71(W)x90(H)x61(L) mm Usage temperature: 0C... +45C 3

Storage temperature: -15C... +55C Net Weight: 119g Gross Weight: 137g Warranty: 2 years Relative Humidity: 10...95 % without condensation Note! In first batch of LM5 devices, the 24V DC clamp powering ports are placed vice versa rather than showed on diagrams! 4

Caution Security advice The installation and assembly of electrical equipment may only be performed by skilled electrician. The devices must not be used in any relation with equipment that supports, directly or indirectly, human health or life or with application that can result danger of people, animals or real value Mounting advice The devices are supplied in operational status. The cables connections included can be clamped to the housing if required. Electrical connection The devices are constructed for the operation of protective low voltage (SELV). Grounding of device is not needed. When switching the power supply on or off, power surges must be avoided. 5

KNX connection 6

RS-485 connection There can be used max two RS-485 on LM5p Power. First one is definitive, second one is software switchable either it works as RS-485 or as RS-232 : - If it is set up as full-duplex it will operate as RS-232 and respective TX/RX/GND screw terminals should be used - If it is set up as half-duplex (*) it will operate as RS-485 and respective A/B/GND screw terminals should be used *RS-485 is chosen in this case, RS-232 is not activated 7

RS-232 connection If second serial port is set as full-duplex in LogicMachine configuration, it will operate as RS-232 and respective TX/RX/GND screw terminals should be used. *RS-232 is chosen in this case, RS-485 is not activated 8

Powering LM5 supports two powering modes: - regular powering over screw terminals (Jumpers up or down) - passive PoE powering over 24V DC (Jumpers down) Please note that there are two PoE types of PoE switches/adapters passive and active (802.3af). In passive mode 4 Ethernet cable wires are used for data and 4 are used for power. In active PoE mode data and power goes together. Note! In first batch of LM5 devices, the 24V DC clamp powering ports are placed vice versa rather than showed on diagrams! 9

Passive PoE switch Passive PoE adapters 10

DALI connection There are two DALI master interfaces in this device. You can connect up to 64 DALI ballasts to each master interface. 11

1-wire connection There are two 1-wire interfaces in this device. 12

Quick startup guide 1) Mounting the device on DIN rail 2) Connect the KNX bus cable 3) Connect 24V power supply to the device (either through separate 24V screw terminals or through Passive 24V DC Power-Over-Ethernet) 4) Connect Ethernet/LAN cable coming from the PC Default IP configuration Login name admin Password admin IP address 192.168.0.10 Network mask 255.255.255.0 Reset device You can either reboot the device by pressing RESET button or reset the configuration to factory defaults: Press and hold for <10 sec reboot the device Press and hold for >10 sec reset networking with IP to factory default Press and hold for >10 sec and again press and hold for >10 sec full reset of configuration to factory defaults 13