Agilent 68xx Agilent 68xx

Similar documents
Clarity Controls Clarity Controls Agilent 5890 Agilent 5890

ERC REFRACTOMAX 520. Clarity Control Module. Code/Rev.: M190/70C Date: 8/23/2018

Clarity Hardware. Duratec DDT 3200 USB. Code/Rev.: M064/24C 27 September 2006

HT3X00A. Clarity Control Module. Code/Rev.: M153/50E Date: 11/13/2018. Fax: Petrzilkova 2583/ Prague 5

HITACHI LACHROM ELITE

MULTICOM. Clarity Hardware. Code/Rev.: M110/80A Date: 8/15/2018. Fax: Petrzilkova 2583/ Prague 5

Contents 1 Opt-USB 2 Requirements 3 Installation 4 Troubleshooting 5 Tables and specifications

COLIBRICK A/D CONVERTER

U-PAD2 A/D CONVERTER

INT7 A/D CONVERTER. Clarity Hardware. Code/Rev.: M058/80A Date: 6/6/2018

U-PAD A/D CONVERTER. Clarity Hardware. Code/Rev.: M059/80A Date: 6/6/2018

AGILENT 1100/1200. Clarity Control Module. Code/Rev.: M060/70D Date: 10/5/2017

SHIMADZU LC-10/20 SYSTEM

DESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Clarity. Clarity Demo. Code/Rev.: M003/60A Date: Fax: Petrzilkova 2583/ Prague 5

SCN 848 Release Notes

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

WinCT-Plus Instruction Manual

D8000 SERIES QUICK START GUIDE

EDS4100 Quick Start Guide

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

NetBiter Serial Server User Manual

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

XPress DR+W Quick Start Guide

RANGER SERIES. 150Mbps Wireless Green Broadband Router DG-BR4000NG. 150 Mbps V

Data Acquisition with 3400/3600 GC Control

EDS8/16/32PR Quick Start Guide

Use a hardwired Ethernet to RS232 Converter [Moxa N Port Express ]

WIZ220IO / WIZ220IO-EVB User s Manual (Ver. 1.0)

TTL TO ETHERNET Module. MODEL No: TTL-Sereth1P VER 1.0

CLARITY DEMO. Clarity Demo Software. Code/Rev.: M003/70E Date:

User Manual Anybus Serial Server

IntesisBox Modbus Server Siemens Synova FC330A

Communication adapter RS232 over the Wi-Fi ELO E231. User manual

WiBox 2100 Quick Start Guide

PDA EXTENSION. Clarity Extension. Code/Rev.: M054/80A Date: 6/8/2018. Fax: Petrzilkova 2583/ Prague 5

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

TCP/IP TO SERIAL (SINGLE PORT) MODEL No: SerEth-1P VER 2.0

IntesisBox Modbus Server Fidelio IP

Data Acquisition Software and Hardware Demonstration Guide

SP PRO Communications LAN Connectivity

3.1 I-7560 Pin Assignment and Specifications: Introduction

8 TS4-DDH T i g e r S t o p M a n u a l D a t a D o w n l o a d i n g. May 2006 Version 3.5 ~ 4.72 Hardware

LC UNI - SSI PUMPS. Clarity Control Module. Code/Rev.: M038/40D Date:

USB ph MONITOR. DataApex Clarity Control. Doc. #: DI Rev. A Praha, March 2013

Data Acquisition Software and Hardware. Demonstration Guide. For: NetDAQ Logger, Hydra Logger, and Trend Link for Fluke V3.1

Fluke Metrology Software

UCI-50 and UCI-100. Universal Chromatography Interfaces. Operating Instructions. Revision: 3.1 Date: October Dionex

1 IBM-compatible PC running Windows 98, 2000 or XP, and one Network Interface Card (NIC) with TCP/IP communication protocol enabled

Instrument Network (INET) or Local Area Network (LAN) Communications Interface Board Installation Guide

GNOME485. Ethernet to RS485 converter Eas y to use. Security features. Virtual serial port. 2/16/2006 w w w. p a p o u c h.

ez80190 Development Kit Quick Start Guide

Data Acquisition. Software and Hardware. Demonstration Guide. For: NetDAQ Logger for Windows Hydra Logger for Windows Trend Link for Fluke

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual

SICO-300 COLUMN OVEN

Chemical Analysis Group Gas Chromatograph Common Cabling \ Pin-outs Document A15707

TigerStop Ethernet-to-Serial Converter Installation & User s Guide v4.2

SCS1600/3200 Quick Start Guide

MODBUS TCP/IP TO MODBUS SERIAL GATEWAY. MODEL No: MGate-1024-DC VER 2.0

SCADALink IP100 SCADA Terminal Server QUICK START GUIDE Revision 1.42 June 19, 2012

C5100 Computer Connections & Software Install Guide

ELK-IP232 INSTALLATION AND CONFIGURATION MANUAL. Ethernet to Serial Bridge /07

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

User s Guide. Ethernet Module for Barcode Printer

RS-232/422/485 Over IP Adapter

Agilent GC Drivers A

HVR LINE INSTALL GUIDE

FSA-CU Configuration Utility Programming Guide

NM-541-MUX TECHNICAL APENDIX V1.00

Before you install the hardware, ensure the following components are included in your shipment:

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

Model 375 Ethernet Software LMI Part No Software Manual Version October 2013

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

SWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

Longshine Technologie Europe GmbH

USB-C to RJ45 FTDI Console Cable USB-A to RJ45 FTDI Console Cable

EQ7000. User Manual. Rev 1.00

WiSpan Quick Start Guide

Wireless PC Network Settings

Installing the Ampire UART TFT

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

(1) Device Management tool: enables you to remotely manage AX220xx RS232-to-WiFi devices.

Hardware Installation Guide Installation (x3350)

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

TOSVERT VF-AS1/PS1. Trace Tool PCT001Z-E. Instruction Manual

Installation Guide of Hi-Speed USB-to-Optically Isolated RS-422/485 Adapter

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

Installation Guide of Hi-Speed USB Industrial I/O Adapter

898 XYZ Sample Changer

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

MOXA VPort 2110/2140/2141 Video Server Quick Installation Guide

factory field upgrade

LC1003A IP Security CCTV Connector Installation Guide

Using SIMDIS Expert 9 (Separation Systems) with Clarity

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command

imcu7100evb User s Guide

Product Family: Networking Hardware Number: AN-NH-012

Transcription:

GC Clarity Controls Clarity Controls Agilent 68xx Agilent 68xx ENG Code/Rev.: M041/24F 1. February 2007 Phone: +420-251 013 400 DataApex Ltd. 2007 Fax: +420-251 013 401 Podohradská 1 clarity@dataapex.com 155 00 Prague 5 www.dataapex.com The Czech Republic

Clarity, DataApex and are trademarks of DataApex Ltd. Microsoft and Windows TM are trademarks of Microsoft Corporation DataApex reserves the right to make changes to manuals without prior notice. Updated manuals can be downloaded from www.dataapex.com.

Table of Contents 1 Agilent 68xx GC Control Module...4 2 Accessories Needed:...5 3 Installation Procedure...6 3.1 GC Chromatograph setup...6 3.2 Installing the GC module in the PC...7 3.3 Clarity configuration:...8 3.3.1 Configure the Agilent 68xx GC control module:...8 3.4 Host Ready Control (Digital Output)...11 4 Using the Control Module...13 4.1 Method Setup GC Control...13 4.2 Method Setup - Acquisition...15 4.3 Method Setup AS Control...16 4.4 Hardware Configuration...17 5 Connections...18 5.1 Wiring...18 5.2 Description of connectors:...19 6 Troubleshooting...20 3

1 Agilent 68xx GC Control Module Agilent 68xx GC Control Module The Agilent 68xx GC driver can control Agilent 6890, 6890N, 6820 and 6850 GC chromatographs and the Agilent 7683 autosampler (including tray). Agilent 7683 autosampler can be controled only through 6890N, 6820 and 6850 chromatographs. Fig. 1. GC 6890 with autosampler The direct control can be performed via COM (RS232) LAN 6890N, 6820 and 6850 models only Data Acquisition can be performed via COM (RS232) Clarity Digital Data Acquisition LAN Clarity Digital Data Acquisition ANALOG analog signal to A/D converter (eg. INT7 or U-PAD). 4

Accessories Needed: 2 Accessories Needed: Caution! Installation CD ROM Clarity with GC module. When using LAN communication LAN communication is supported since Clarity ver. 2.4. LAN cable. There are two types of LAN cables - straight used for connection of PC or instrument to hubs or network sockets and crossed used for direct connection of device to PC. Use of the appropriate type is neccessary. LAN card in PC When using COM communication Serial cross cable DB9F DB9F (Rx to Tx and vice versa) If serial communication cannot be established and all parameters of communication are correctly set (speed, parity, etc.), then we recommend to remeasure the cable according to the following scheme (especially pin connection 2 and 3). Fig. 2. Serial cross cable DB9F DB9F Free serial port in the PC (fast - 16550 UART) 5

3 Installation Procedure Installation Procedure 3.1 GC Chromatograph setup It is necessary to find out the communication parameters for the desired type of communication (LAN or COM). These parameters will then have to be set in the Clarity GC Control module. Connect the appropriate cables between the GC chromatograph and PC. Agilent 6850 GC can be purchased also without the display unit for setting the communication parameters. It is then necessary to obtain the communication parameters from the Agilent service technician. When connecting the 6850 model it is necessary to observe following sequence of steps: 1) connect the cables, 2) then switch on the PC and then switch on the GC.This model detects the type of communication (COM or LAN) automatically. When using the LAN communication it is recommended to attach the GC chromatograph directly to the PC avoiding HUBs, Switches etc. Contact your local LAN administrator who can make the appropriate settings. Do not use the Agilent 68xx DHCP server feature. 6

Installation Procedure 3.2 Installing the GC module in the PC Caution! Select and if necessary install a fast serial port in the PC. In the following procedure the setup of HP 68xx with digital acquisition (without A/D converters) will be described. Install Clarity station, in the HW Setup dialog check the No Card option during installation. Fig. 3. HW Setup Connect the GC chromatograph to the PC by serial cable (COM) or by LAN, turn the power GC on. 7

Installation Procedure 3.3 Clarity configuration: 3.3.1 Configure the Agilent 68xx GC control module: Invoke the System Configuration dialog acessible from the Clarity window using the System Configuration command. Press the Add button (see Fig. 8) to invoke the Available Control Modules dialog. Fig. 4. Available Control Modules Select the Agilent 68xx GC Driver and press the Add button. The Setup dialog dialog will appear. Fig. 5. Connection Setup Select the Communication Protocol, which can be RS232 (COM) or LAN. For RS232: Set COM port and Baud Rate according to the setting in the chromatograph. 8

Installation Procedure For LAN: Set the IP Address according to the setting in the chromatograph. The GC communication settings are accesible by the Options button from the GC keyboard, then scroll to the Communications section. For RS 232 the settings should be set to 8 data bits, 2 stop bits, No handshake. Baud rate and terminating sequence must comply with the settings in Clarity. For LAN communication settings, the Enable DHCP option should be OFF (it is not supported by Clarity). For direct connection to PC use crossed LAN cable and manually set the IP address and Subnet mask in both PC and the GC. Following settings example can be used (the IP address should differ in the last digit group) : In the PC IP address: 192.168.0.1 Subnet mask: 255.255.255.0 In the GC IP address: 192.168.0.2 Subnet mask: 255.255.255.0 If your computer is connected into a local LAN, assign the GC a free IP address from the relevant IP range. Contact your LAN administartor for details. When you have the 6850 model without display and you do not know the Baud Rate it will most probably be 9600. The Controller Module may be needed to determine or change the settings during isntallation; it is not needed for normal operation. 9

Go to the Devices tab Installation Procedure Fig. 6. Devices Setup Use the Autodetect button to read in instrument configuration and check the communication. Control the detected parameters against the GC parameters. When the Agilent 7683 Autosampler controlled through the GC is present (6890N, 6820, 6850), check the Use Sampler checkbox and select present towers (Front and/or Back). Go to the Detectors Setup tab Fig. 7. Detectors Setup Check the Digital Acquisition checkbox and fill in the names of your detectors. Press the OK button. The Agilent 68xx GC Driver item will appear in the Setup Control Modules list in the left part of System Configuration dialog. 10

Installation Procedure Switch to the desired Instrument X tab in the right part of the System Configuration dialog. The Instrument Type must be set to GC. Fig. 8. System Configuration Drag the Agilent 68xx GC Driver from the Setup Control Modules in the left to the instrument on the right or use the --> button. Drag only one detector to the Instrument tab if you do not wish to acquire both signals simultaneously 3.4 Host Ready Control (Digital Output) The Host Ready Control dialog defines the initial state of Agilent 68xx digital output, used for synchronisation with autosamplers or other external devices. It is accessible using the System Digital Outputs command from the Clarity window. 11

Installation Procedure Fig. 9. Host Ready Control When multiple devices are configured on Clarity, select the Agilent 68xx driver from the list. Fig. 10. Select control window Caution! The default settings (Ready) are necessary for operation without autosampler, otherwise the GC will be still in HOST NOT READY state. For Active Sequence, it must be changed to NOT READY state. The Active Sequence changes the digital output state level when the command for injection is sent out and again back, when the injection is performed. If it was initially READY, it would have been changed to NOT READY and the sampler would be prevented from injection by the HOST NOT READY state. 12

Using the Control Module 4 Using the Control Module New tab GC Control appears in the Method Setup dialog, enabling the setting of the GC control method. If the 7683 sampler is configured there will appear also AS Control tab for setting the autosampler method. 4.1 Method Setup GC Control Use the From GC button to download current method parameters from Agilent 68xx (and save it under suitable name). You can use this procedure to copy the parameters of your methods already stored in the GC memory to Clarity. Use the To GC button to upload the Clarity method GC parameters to Agilent 68xx. Use the GC Status button to see the current GC configuration (inlets, detectors etc.). Fig. 11. Method Setup GC Control Oven/Zones In DEMO mode it enables selecting them) 13

Caution! Using the Control Module Use the upper tabs in the Method Setup - GC Control dialog to set or modify the GC control parameters. The apparance of the individual dialogs depends on actual configuration of the Agilent 68xx chromatograph. Individual options (e.g. its availability) may also depend on the settings of other options across the tabs. For example setting in one tab can disable another option in another tab. On the Signals tab, it is possible to determine the source for the output Signals. The Signal 1 or 2 will be then sent to the Clarity chromatography station either through analog output to Detector 1 or 2 of INT7/U- PAD A/D converter or using the digital output to the Detector 1 or 2 of the Clarity Digital Acquisition. These detectors can be configured in the System Configuration dialog (displayed on p. 11). Fig. 12. Method Setup GC Control - Signals 14

Using the Control Module 4.2 Method Setup - Acquisition In the Method Setup - Acquisition dialog, check the External Start/Stop checkbox and select the voltage range to be acquired. Signals exceeding this value will be cut. Fig. 13. Method Setup Acquisition Caution! When using another sample rate (Rate) then the default (10 Hz) in Single Run analyses it is necessary to send the method to the device manually before starting the acquisition (using the To GC button in the Method Setup GC Control dialog). The GC "forgets" the setting every time it gets into sleep mode or when switched off. 15

Using the Control Module 4.3 Method Setup AS Control In the Method Setup AS Control dialog, set the parameters of the sampler method. Fig. 14. Method Setup AS Control Front Tower The From AS button loads the sampler method from the sampler. To AS button sends the sampler method from Clarity to the autosampler. 16

Using the Control Module 4.4 Hardware Configuration AS Status opens the Hardware Configuration dialog listing the available hardware features of current configuration. Fig. 15. Hardware Configuration 17

5 Connections Connections 5.1 Wiring Signal 1 Signal 2 PC Protective key must be present. Remote Agilent 6890 RS 232 Cannon (9F) Serial line (GC Control + digital data acquisition) COMx Cannon 9/25 Male LAN LAN AGILENT 6890 - RS232 with digital acquisition Signal 1 Signal 2 PC Protective key must be present. Remote Agilent 6890 RS 232 Cannon (9F) COMx Cannon 9/25 Male LAN LAN (GC Control + digital data acquisition) LAN AGILENT 6890 - LAN with digital acquisition Agilent AS 7683 Autosampler Agilent GC 6890 (6850) Autosampler RS 232 Cannon (9F) LAN Serial line (GC Control + digital data acquisition) PC COMx Cannon 9/25 Male LAN AGILENT 6890N (6850) - with AS 7683 18

5.2 Description of connectors: Connections Signal 1 (2) PS/2 connectors with output of both analog amplifiers (connected to detector). Not necessary when using the digital acquisition. Remote 9 pins male Cannon connector dedicated to send start signal to Clarity. Not necessary when using digital acquisition RS232 9 pins male Cannon connector for direct control and digital acquisition. It also may be labeled "Modem" on some 6890 models. LAN RJ45 connector Consult the servis manual relevant to the GC type. 19

Troubleshooting 6 Troubleshooting Host not Ready message Check the Initial State of the digital outputs of the Host Ready Control Agilent 68xx. For manual injection, the state should be READY, while for active sequence with autosampler it must be NOT READY. This dialog can be invoked by the System Digital Outputs command from the main Clarity window. Error while starting the sequence The Active Sequence should be started from Clarity. If it is started from both Clarity and the GC Keyboard simultaneously an error message will be issued. Agilent 68xx LAN connection When connecting the 68xx to a PC using the LAN cable do not use the Agilent 68xx feature when it can work as a DHCP server. Check the IP address settings and type of cable used. 20