OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide

Similar documents
CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Certification Testing Quick Reference Guide

OFS 300 Optical Fiber Scope User s Guide

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide

Operation Manual for OLS-1315 Optical Light Source

Operation Manual for OPM-1315 Optical Power Meter

FlexScan OTDR With SmartAuto and LinkMap

HCC-CW-201A. CWDM Analyzer. Operation Guide

LTS-2A LTS-10 LTS-10C LTS-11 LTS-12

OLS-55/56 Sm a r t Optical Laser Source A Sm a r t, Future-Proof Optical Laser Source

Model RP450. Optical Power Meter

M-Series OTDRs. User s Guide. (800) or (603)

Rev. F January 13, 1999 Part Number: OFL Operations Manual for the OFL 100 Mini-OTDR

OPM-50 Optical Power Meter User s Manual

OTS-400 Series Optical Meters, Sources and Testers A LANscape Solutions Product

PPM-30 PON Power Meter. User s Manual. Shineway Technologies, Inc. All rights reserved.

FlexScan FS200 OTDR With SmartAuto, FleXpress and LinkMap

OLP-55 Sm a r t Optical Power Meter A Sm a r t, Future-Proof Optical Power Meter

PM-204A/B. Power Meter. Operation Guide

Optical Power Meter. TrendCommunications. User Guide Testing the World s Networks

LTS-1 LTS-1C LTS-2 LTS-5 LTS-6 LTS-7 LTS-10 LTS-11 LTS-12. Wilcom. Optical Loss Test Kits. Description LTS-2

FlexScan OTDR With SmartAuto and LinkMap

Machine Layout Basics

FlexScan FS200 OTDR With SmartAuto, FleXpress and LinkMap Quick Reference Guide

Light-Source Mainframe

PM-100 SERIES. Operation Guide. Power Meter V

10G SFP+ Checker 2012 VER B. Page 1 of 9 3F-5, No. 30 Taiyuan Street, Chupei City, Hsinchu County 302, Taiwan

FIBER. WP-TEST-FIBER-400 Optical Power Meter Owner s Manual

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

Technical Specification. for. 10 Gbps SFP+ Checker

SmartPocket Optical Power Meter OLP-34/35/38

OTS-400 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities A LANscape Solutions Product

OTDR Testing Quick Reference Guide

FTE-6000 Hand Held Tuneable Laser Source

Handheld Optical Power Meter. Model SSF-TKITP-400 OPTICAL POWER METER. Manual

KI 2400/2800 SERIES HAND HELD FIBER SOURCE FEATURES. kingfisher.com.au. OPTICAL COMMUNICATIONS TEST APPLICATIONS (in combination with a power meter)

OLT-55. Intelligent Optical Loss Tester. User s Manual

C2000 POWER METER With Data Storage

USER MANUAL FOT-PM Optical Power Meter

VFS 2 Video Fiber Scope User s Guide. Test & Inspection

FX40/45 Series Manual D P RevA00 Page 1 of 25. FX40/45 Series Manual D P RevA00 Page 1 of 25

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

AF-OLK5A Series Fiber Optic Test kit

Training Training Manual: Manual: KI9800A Series Pocket Fibre Sources Level 1

FOCIS Flex Fiber Optic Connector Inspection System User Guide

M200 Handheld OTDR User s Guide

LTK-400 Series Optical Sources, Meters and Kits Without Data Storage Capabilities

Annexure-I: Technical Specification of Handheld Optical Power Meter Purchase Ref: Parameter ITI Specification Vendor-1 Vendor-2 Vendor-3 Remarks

JDSU Optical Handheld Testers. Family of light sources, power meters, attenuators, loss test sets, return loss meters, and optical talksets

FOCIS Duel Fiber Optic Connector Inspection System User Guide

V-9908 MESSAGE/PAGE PANEL

VIAVI. OLA-54 and OLA-55. SmartClass. Data Sheet. Optical Level Attenuator. VIAVI SmartClass optical handhelds go beyond the basics.

Optical Power Meter With VFL. User Manual

VIAVI SmartClass OLA-55M

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

FiberBasix 50 Handheld Testers

AE3100 Series User Manual. Version 1.02

SCT-MMA / SCT-SMA Fiber Optic Adapters

RA3301Optical Multimeter

Test Port Adapters Reference Guide

True RMS AC Voltage/Current Datalogger

RA3211 PON optical power meter

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

VIS Video Inspection Scope

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

OFSR-X. Users Manual. OptiFiber Smart Remote Options

Optical Sources/Power Meter/Attenuator

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

HD-CVI / AHD / HD-TVI Video + Bi-Directional Data

12 Digital Photo Frame Instructional Manual

Optical CWDM Power Meter

Four (4) fibers Detachable HDMI Extender

User's Guide. Vibration Meter and Laser Combination Tachometer Model

5100 Series. Fiberlink. 10/100/1000 Base-T Etheret over one or two single mode or multimode fibers. User s Manual

10 Digital Photo Frame Instructional Manual

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL

CS Contractor Series Live PON OTDR

User Manual Fiber Certification Testing

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R

Stretch FireWire TM. User s Manual M4-200 & 201. Manual Contents.

AQ2170 Optical Power Meter

6400 CWDM Series. Fiberlink. 4 or 8 Channel Coarse Wave Division Multiplexers for Single Mode Fiber. User s Manual

MiniSim 330 EEG Simulator

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

TOM103. Optical Power Meter OPTICAL POWER METER

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

BUYER S GUIDE AND PRICE LIST June 1, 2003

OFL 200 Single-mode Optical Time Domain Reflectometer User s Guide

ES-600 Ozone Controller Operation Manual

HDMI VIDEO SYSTEM USER S MANUAL

User Manual. OLC II Fiber Optic DVI Extension Cable

OZONE SWITCH Model OS-6. OS-6 Features

Mini OTDR MOT-700 USER MANUAL

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125

User s Manual. Two (2) PCs Switchable Dual-head DVI Optical KVM Extender, KVMX-100-TR. Opticis Locations.

Transcription:

OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide

Warranty All NOYES test equipment products are warranted for a period of (1) one year from the date of delivery to the end user. Extended warranties start at the end of the standard (1) one year warranty period. 1 year, 2 year, and 4 year extended warranties are available for NOYES products with or without annual calibration included. Any product that is found defective within the warranty period will, at the discretion of AFL, be repaired or replaced. Warranty will be voided if the product has been repaired or altered by other than an authorized NOYES product repair facility, if the void sticker has been compromised, or which have been subject to misuse, negligence, or accident. In no case shall AFL liabilities exceed the original purchase price. Exclusions The warranty on your equipment shall not apply to defects resulting from the following: Unauthorized repair or modification Misuse, negligence, or accident CE Information These instruments have been designed and tested to comply with the relevant sections of any applicable specifications including full compliance with all essential requirements of all applicable EU Directives. Returning Equipment To return equipment, please contact NOYES to obtain additional information and a Service Request (S.R.) number. To allow us to serve you more efficiently, please include a brief description specifying the reasons for the return of the equipment. AFL NOYES Test and Inspection 16 Eastgate Park Road, Belmont, NH 03220 Tel: 800-321-5298, 603-528-7780 Fax: 603-528-2025 2010-2011, AFL, all rights reserved. OLTK-00-1ENG Revision A, 2011-06-15

OPM Series Optical Power Meters OPM5 New Feature File Management system allows simple organization of power or insertion loss measurements into multiple files. Using the supplied Test Results Management - TRM software and USB connection, test records are transferred to a PC for analyzing, generating professional test reports, and printing. OPM Saved Data USB TRM Laptop/ PC Professional Reports TRM archiving and reporting capabilities take your OPM5 to a new level. Simple USB transfer of saved files (cable supplied) View test results Save test results on your PC / Network Organize standard loss test data into bi-directional loss test data Create Professional Reports for your customers Add link length to loss data and select standard rules to generate Network Certification Reports for your customers. For more information, refer to the TRM software User s Guide (available on supplied CD and www.aflglobal.com/go/software). 3

OPM Series Function Keys Dual Function Keys Legend YY XX Secondary function of a key Primary function of a key Press and hold to activate Press and release to activate File Fiber Power key Provides two functions: Press to turn On/Off (OPM turns off after five minutes of inactivity). Press and hold to disable/enable the Auto Off feature. Arrow/File key (OPM5 models only) Provides several functions: Testing mode: press and hold to enter File mode. File mode: Press to increment the File number. Fiber and Recall mode: press to increment the Fiber number. Arrow/Fiber key (OPM5 models only) Provides several functions: Testing mode: press and hold to enter Fiber mode. Fiber mode: press to decrement the Fiber number. File and Recall mode: press to decrement the File number. Wavelength/Backlight key Provides two functions: Press to cycle through the calibrated wavelengths. Note: When an OPM is receiving a wavelength ID d light, it automatically switches to the ID wavelengths. [WAVE ID] indicator appears on the display. Press and hold to toggle the Backlight on or off. 4

OPM Series Function Keys W db dbm Set Ref Store Recall db/dbm/µw key Provides two functions: Press to toggle test readings between insertion loss in [db] and power in [dbm]. Press and hold to view power in [µw]. Ref/Set key Provides two functions: Press to display the stored reference level for the currently selected wavelength or multiple wavelengths. Press and hold until [HELD SET] is displayed to store the currently measured level or multiple levels as the new reference levels. Once the new reference is set, an OPM switches to the [db] measurement mode. Store key (OPM5 models only) Provides two functions: Test mode: press to save the currently displayed measured data in the next available memory location (next Fiber) of the current File. File/Fiber/Recall/Clear mode: press to return to the Test mode. Recall key (OPM5 models only) Press to enter the Recall mode that allows viewing and deleting stored test records. Press again to exit the Recall mode. Store Clear Recall Clear The Clear mode screen may be accessed and used as follows: From the File mode screen to delete a file From the Recall mode screen to delete a fiber 5

OLS Series Light Sources Dual Function Keys Legend YY Secondary function of a key XX Primary function of a key Press and hold to activate Press and release to activate Keys and Indicators common for all models Power key - Press and hold until all indicators light up to turn OLS On/Off. 9V External Power indicator - Lights up, whether the unit is on or off, when the correct AC power adapter is connected Low Battery indicator - Lights up when a Low Battery condition exists; batteries require replacement Refer to keys and indicators that are applicable to your OLS light source model. OLS1-Dual LED Light Source Keys and Indicators CW 850nm 1300nm 850nm 1300nm Wavelength/CW select key Press to select multimode single or dual Wave ID wavelengths Press and hold to switch to the CW mode at the currently transmitted wavelength, then press the key to toggle between wavelengths Active Output indicators - Light up when the corresponding output port is ON Single or dual Wave ID - ON continuous light CW - ON blinking light 6

OLS2-Dual Laser Source Keys and Indicators l 1310nm 1550nm Wavelengths select key Wave ID mode - selects SM single or dual Wave ID wavelengths CW or Tone mode - selects single wavelength Active Output indicators - will be illuminated when the corresponding output port is ON Mode Wave ID CW Hz Mode key - Press to select operating mode (Wave ID, CW, Tone) Active Mode indicators - light up as the corresponding mode is enabled Output Adjust keys - allow entering Output Adjust mode and increase ( ) or decrease ( ) current power level within ~ 3 db range between the factory preset maximum and minimum power levels OLS4 Integrated LED & Laser Source Keys and Indicators CW 850nm 1300nm 850nm 1300nm Multimode Wavelength/CW select key Press to select single or dual Wave ID wavelength(s) Press and hold to switch to the CW mode at the current wavelength, then press the key to select a single wavelength Active Output indicators - Light up when the corresponding output port is ON Single or dual Wave ID - ON continuous light CW - ON blinking light 7

OLS4 Integrated LED & Laser Source Keys and Indicators CW 1310nm 1550nm 1310nm 1550nm Tone Single-mode Wavelengths/CW select key Press to select single or dual Wave ID wavelength(s) Press and hold to switch to the CW mode at the current wavelength, then press the key to select a single wavelength Active Output indicators - Light up when the corresponding output port is ON Single or dual Wave ID - ON continuous light CW or Tone (at 1550 nm) - ON blinking light Tone key - Press to enable/disable 2 khz Tone on the SM port at 1550 nm wavelength Tone indicator is ON when OLS4 is transmitting a Tone signal OLS7 Triple Wavelength Laser Source Keys and Indicators l Mode Wave ID CW Hz Wavelengths select key Wave ID mode - selects single, dual, or triple Wave ID wavelengths CW or Tone mode - selects single wavelength 1310nm 1550nm 1625nm or 1310nm 1490nm 1550nm Active Output indicators - will be illuminated when the corresponding output port is ON Mode key - Press to select operating mode (Wave ID, CW, Tone) Active Mode indicators - light up as the corresponding mode is enabled 8

Measuring Optical Power with OPM meter It is important to keep all optical connections and surfaces clean to ensure accurate measurements and operation. Always clean all test jumpers before conducting tests. 1. Turn on OPM (optical power meter). 2. Select the appropriate fiber optic test jumper. The fiber type of this jumper must be the same as the fiber type normally connected to the output being measured. 3. Mount the appropriate adapter cap on the OPM port. This adapter cap must match the connector on the end of the test jumper you will connect to the OPM. 4. Connect one end of the test jumper to the OPM adapter cap and the other end to the optical output to be measured. 5. Press [λ] to select wavelength that matches the nominal wavelength of the source being measured. 6. Press [db/dbm/µw] to display power in [dbm] or press and hold to display power in [µw]. 7. OPM5 only: Press [Store] to save the displayed measurement in the next available memory location. Test jumper 4 4 3 Adapter cap Output Input Fiber optic equipment -20 dbm OPM 9

Testing Multimode or Single-mode Links Step I - Set the Reference (One Jumper Method) 1. Turn on the OPM and OLS. Allow OLS to stabilize (minimum of 2 minutes). 2. If not using WAVE ID feature, set both instruments to the desired wavelength. 3. Select transmit and receive jumpers (fiber type must match link to be tested). 4. MM: Wrap and secure transmit jumper five times around mandrel. SM (TIA testing only): Make and secure 30 mm loop in a transmit jumper. Clean both ends of the transmit jumper! 5. Connect the transmit jumper to the OLS output port (MM or SM respectively). 6. Mount adapter cap on the OPM (must match free connector on transmit jumper). 7. Connect transmit jumper (free end) to the OPM. Display optical power in [dbm]. 8. If measured power is outside of the normal range (specified by manufacturer), clean all fiber connections or replace the transmit jumper. Repeat steps 4-7. 9. Set reference level: on OPM, press and hold [Ref/Set] until [HELD SET] is displayed to store currently measured level as the new reference level. Once set, OPM switches to [db] mode. OPM should display [0 db] ± 0.05 db. 4 Transmit jumper Mandrel wrap - MM (shown), or 30 mm loop - SM 7 5 6 OLS 10 0 db OPM

Testing Multimode or Single-mode Links Step II - Verify Test Jumpers 10. Disconnect the transmit jumper from the OPM. Do not disturb the transmit jumper at the OLS end! 11. If needed, change OPM adapter cap to match receive jumper connector. Clean both ends of the receive jumper! 12. Connect the receive jumper to the OPM. 13. Mate free ends of transmit and receive jumpers using the appropriate adapter. 14. Verify that the insertion loss of this mated connector pair is under 0.75 db - maximum allowed by TIA (NOYES recommends 0.4-0.5 db typical): Observe the displayed value - insertion loss of the test jumpers in [db]. If value is not acceptable, disconnect transmit and receive jumpers at the adapter, clean free ends of both test jumpers and repeat steps 13 & 14. If value is still not acceptable, replace test jumpers and repeat steps 1-14. 15. If loss value is acceptable, disconnect transmit and receive jumpers at the adapter. 16. Move the OPM and OLS to opposite ends of the link to be tested. Transmit jumper Adapter Receive jumper Do NOT disturb this connection 13 12 Mandrel wrap - MM (shown), or 30 mm loop - SM 11 OLS 11 0.4 db OPM

Testing Multimode or Single-mode Links Step III - Measure Multimode Link Insertion Loss 17. Connect free ends of transmit and receive jumpers to the link under test. Clean jumper end that connects to patch panel prior to every test! 18. OPM will measure and display the insertion loss of the link under test. 19. Perform one of the following: If using OPM4: Record link insertion loss at the current test wavelength. If using OPM5: Press the [Store] key on the OPM5 to save the displayed measurement in the next available memory location. 20. Repeat steps 17-19 for all links to be tested at the current wavelength. Transmit jumper Patch panel ~ Patch panel Receive jumper Link under test Mandrel wrap - MM (shown), or 30 mm loop - SM 2 db OLS OPM www.aflglobal.com/go/noyes or (800) 321-5298 or (603) 528-7780 12