SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

Similar documents
SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Preface. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Parameters 2.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information

ST (6ES7132-6FD00-0BB1)

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Readme SiVArc V14 SP1 Update 6

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

ST (6ES7522-1BH00-0AB0)

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

Digital output module. DQ 4x24VDC/2A ST (6ES7132-6BD20-0BA0) SIMATIC. ET 200SP Digital output module DQ 4x24VDC/2A ST (6ES7132-6BD20-0BA0) Preface

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

Digital output module. DQ 16x24VDC/0.5A ST (6ES7132-6BH00-0BA0) SIMATIC. ET 200SP Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH00-0BA0)

Digital output module. DQ 8x24VDC/0.5A HF (6ES7132-6BF00-0CA0) SIMATIC. ET 200SP Digital output module DQ 8x24VDC/0.5A HF (6ES7132-6BF00-0CA0) Preface

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

ST (6ES7522-5HF00-0AB0)

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Digital output module. DQ 16x24VDC/0.5A HF (6ES7522-1BH01-0AB0) SIMATIC

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. S7-1500/ET 200MP Digital output module DQ 32x24VDC/0.5A BA (6ES7522-1BL10-0AA0) Preface. Documentation guide. Product overview.

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

Siemens Drives & PLCs

Digital output module. DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) SIMATIC

S7-300 Programmable Controller

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

SIMATIC. Function modules FM 351 First Steps in Commissioning. Purpose of the Getting Started. Requirements 2

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

English. SIMATIC Sensors. RFID-Systems RF600. Getting Started. Edition 11/2005; J31069-D0172-U001-A1-7618

Analog Output Module AQ 4xU/I ST (6ES7135-6HD00-0BA1) SIMATIC. ET 200SP Analog Output Module AQ 4xU/I ST (6ES7135-6HD00-0BA1) Preface

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

First Steps with S7-PDIAG and ProAgent

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

SIMATIC. ET 200SP Digital output module DI 8x24VDC SRC BA (6ES7131-6BF61-0AA0) Preface. Documentation guide. Product overview.

HawkEye 45T Display User Manual

SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009

PROFIsafe SITRANS. Pressure transmitter SITRANS P, DS III PROFIsafe series. Product Information 7MF4*34 04/2008 A5E

Manual Edition 03/2010

SIMATIC. ET 200SP Digital output module RQ 4x120VDC-230VAC/5A NO ST (6ES7132-6HD01-0BB1) Preface. Documentation guide. Product overview.

SIMATIC. Industrial software WinAC RTX F Introduction 1. Selecting suitable hardware 2. Installing/removing the WinAC RTX F 2009 software

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

Technological Functions SIMATIC. ET 200S Technological Functions. Preface 1. 1Count24V. 1Count5V 3 1SSI 4 2PULSE. Operating Instructions

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. S7-1500/ET 200MP Digital input module DI 16x24VDC BA (6ES7521-1BH10-0AA0) Preface. Documentation guide. Product overview.

SIMATIC. S7-1500/ET 200MP DI 16x230VAC BA Digital Input Module (6ES7521-1FH00-0AA0) Preface. Documentation guide. Product overview.

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

PD PA AP How To Configure Maxum II TimeServer Access

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

SIMATIC. Process Control PCS 7 V7.0 PCS 7 OS Process Control. Preface, Contents. Additional Documentation 1 Functions of the PCS 7 OS in Process Mode

CM PtP RS422/485 BA communication. module (6ES7540 1AB00 0AA0) SIMATIC. S7-1500/ET 200MP CM PtP RS422/485 BA communication module (6ES7540 1AB00 0AA0)

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SIMATIC Distributed I/O Product information for the ET 200iSP Operating Instructions (A5E ) 01/2010

Siemens Industrial s

Digital input module. DI 8x24VDC HF (6ES7131-6BF00-0CA0) SIMATIC. ET 200SP Digital input module DI 8x24VDC HF (6ES7131-6BF00-0CA0) Preface

SIMATIC. Distributed I/O Device ET 200iSP. Preface, Contents. Product Overview Getting Started with Commissioning. Configuration Options.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

SIMATIC. ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Preface. Guide to the documentation. New properties. Product overview 3

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

Analog output module AQ 2xI ST (6ES7135-6GB00-0BA1) SIMATIC. ET 200SP Analog output module AQ 2xI ST (6ES7135-6GB00-0BA1) Preface. Documentation guide

SIMATIC. ET 200SP Digital input module DI 8x24VDC BA (6ES7131-6BF01-0AA0) Preface. Documentation guide 1. Product overview 2.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Transcription:

Preface 1 Properties 2 SIMATIC Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual 01/2008 A5E01254028-01

Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE Qualified Personnel Prescribed Usage Trademarks indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Note the following: Disclaimer of Liability WARNING This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Automation and Drives Postfach 48 48 90327 NÜRNBERG GERMANY A5E01254028-01 P 02/2008 Copyright Siemens AG 2008. Technical data subject to change

Table of contents 1 Preface... 5 2 Properties... 7 2.1 Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-...7 3 Diagnostics... 11 3.1 Diagnostics using LED display...11 Index... 13 Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual, 01/2008, A5E01254028-01 3

Table of contents Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-4 Manual, 01/2008, A5E01254028-01

Preface 1 Purpose of the manual This manual supplements the ET 200S Distributed I/O System Operating Instructions. General functions for the ET 200S are described in the ET 200S Distributed I/O System Operating Instructions. The information in this document along with the operating instructions enables you to commission the ET 200S. Basic knowledge requirements To understand these operating instructions you should have general knowledge of automation engineering. Scope of the manual This manual applies to this ET 200S module. It describes the components that are valid at the time of publication. Recycling and disposal Thanks to the fact that it is low in contaminants, this ET 200S module is recyclable. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste. Additional support If you have any questions relating to the products described in these operating instructions, and do not find the answers in this document, please contact your local Siemens representative. http://www.siemens.com/automation/partner The portal to our technical documentation for the various SIMATIC products and systems is available at: http://www.siemens.com/automation/simatic/portal The online catalog and ordering system are available at: http://www.siemens.com/automation/mall Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual, 01/2008, A5E01254028-01 5

Preface Training center We offer courses to help you get started with the ET 200S and the SIMATIC S7 automation system. Please contact your regional training center or the central training center in D -90327, Nuremberg, Germany. Phone: +49 (911) 895-3200. http://www.siemens.com/sitrain Technical Support You can reach technical support for all A&D projects using the support request web form: http://www.siemens.com/automation/support-request Phone: + 49 180 5050 222 Fax: + 49 180 5050 223 For more information about our technical support, refer to our Web site at http://www.siemens.de/automation/service Service & Support on the Internet In addition to our documentation services, you can also make use of our comprehensive online knowledge base on the Internet. http://www.siemens.com/automation/service&support There you will find: Our Newsletter, which constantly provides you with the latest information about your products. The right documentation for you using our Service & Support search engine. The bulletin board, a worldwide knowledge exchange for users and experts. Your local contact for Automation & Drives in our contact database. Information about on-site services, repairs, spare parts. Lots more can be found on our "Services" pages. Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-6 Manual, 01/2008, A5E01254028-01

Properties 2 2.1 Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Properties Digital electronic module with four outputs Output current 0.5 A per output Rated load voltage 24 VDC Short-circuit protection Suitable for solenoid valves, DC contactors, and indicator lights Supports isochronous operation Extended temperature range from 0 to 55 C with vertical installation Peculiarity When you connect the 24 VDC rated load voltage to the power module by means of a mechanical contact, depending on the circuit the digital outputs carry the "1" signal for approximately 50 µs. You need to take this into account if you connect the module to fast counters. General terminal assignment Note Terminals 4, 8, A4, A8, A3 and A7 are only available on specified terminal modules. Terminal assignment for 4DO DC24V/0.5A ST (6ES7132-4BD02- Terminal Assignment Terminal Assignment Notes 1 DO0 5 DO1 DOn: Output signal, Channel n 2 DO2 6 DO3 M: Chassis ground 3 M 7 M AUX1: Protective-conductor terminal or voltage bus (freely usable up to 230 VAC) 4 M 8 M A4 AUX1 A8 AUX1 A3 AUX1 A7 AUX1 Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual, 01/2008, A5E01254028-01 7

Properties 2.1 Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Usable terminal modules TM-E15C26-A1 (6ES7193-4CA50- TM-E15S26-A1 (6ES7193-4CA40- TM-E15N26-A1 (6ES7193-4CA80- Usable terminal modules for 4DO DC24V/0.5A ST (6ES7132-4BD02- TM-E15C24-A1 (6ES7193-4CA30- TM-E15S24-A1 (6ES7193-4CA20- TM-E15N24-A1 (6ES7193-4CA70- TM-E15C24-01 (6ES7193-4CB30- TM-E15S24-01 (6ES7193-4CB20- TM-E15N24-01 (6ES7193-4CB70- TM-E15C23-01 (6ES7193-4CB10- TM-E15S23-01 (6ES7193-4CB00- TM-E15N23-01 (6ES7193-4CB60- Spring terminal Screw-type terminal Fast Connect Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-8 Manual, 01/2008, A5E01254028-01

Properties 2.1 Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Block diagram Figure 2-1 Block diagram of the 4DO DC24V/0.5A ST Technical specifications of 4DO DC24V/0.5A ST (6ES7132-4BD02- Dimensions and weight Width (mm) 15 Weight Approx. 40 g Module-specific data Supports isochronous operation Yes Number of outputs 4 Cable length Unshielded Max. 600 m Shielded Max. 1000 m Parameter length 1 byte Address space 1 byte Address space (packed) 4 bits Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual, 01/2008, A5E01254028-01 9

Properties 2.1 Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Voltages, currents, potentials Rated load voltage L+ (from the power module) 24 VDC Reverse polarity protection Yes 1 Total current of the outputs (per module) 2 A Galvanic isolation Between the channels No Between the channels and backplane bus Yes Permissible potential difference Between the different circuits 75 VDC / 60 VAC Insulation tested 500 VDC Current consumption From the rated load voltage L+ (no load) Max. 10 ma per channel Power dissipation of the module Typically 0.8 W Status, interrupts, diagnostics Status display Green LED per channel Diagnostics function No Data for selecting an actuator Output voltage At signal "1" Min. L+ (-1 V) Output current At signal "1" Rated value 0.5 A Permitted range 7 ma to 0.6 A With signal "0" (leakage current) Max. 0.5 ma Output delay (for resistive load) At "0" to "1" Max. 50 µs Typically 45 µs At "1" to "0" Max. 120 µs Typically 90 µs Load resistor range 48 Ω to 3.4 kω Lamp load Max. 5 W Connecting two outputs in parallel For redundant triggering of a load Yes (per module) To increase performance No Control of a digital input Yes Switch rate For resistive load Max. 800 Hz On inductive load 2 Hz For lamp load 10 Hz Limitation (internal) of the voltage induced on Typically L+ (-55 V to -60 V) circuit interruption Reverse-voltage proof Yes, if using the same load voltage as at the power module Short-circuit protection of the output Yes 2 Threshold on Typically 0.7 A to 1.5 A 1 Polarity reversal can lead to the digital outputs being connected through. 2 Per channel Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-10 Manual, 01/2008, A5E01254028-01

Diagnostics 3 3.1 Diagnostics using LED display LED display 1 1 Status display for output status (green) Status displays Event (LEDs) Cause 1 5 2 6 On Output on channel 0 activated. On Output on channel 1 activated. On Output on channel 2 activated. On Output on channel 3 activated. Remedy Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual, 01/2008, A5E01254028-01 11

Diagnostics 3.1 Diagnostics using LED display Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-12 Manual, 01/2008, A5E01254028-01

Index B Basic knowledge requirements, 5 L LED display, 11 D Digital electronic module 4DO DC24V/2A ST Block diagram, 9 Properties, 7 Technical specifications, 9 Terminal assignment, 7 Disposal, 5 I Internet Service & Support, 6 R Recycling, 5 S Scope Manual, 5 Service & Support, 6 T Technical Support, 6 Training center, 6 Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual, 01/2008, A5E01254028-01 13

Index Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-14 Manual, 01/2008, A5E01254028-01