EM2020 Selectable AC transducer A (UK)

Similar documents
DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

DATA SHEET Selectable AC transducer, TAS-331DG

DATA SHEET Selectable AC transducer, TAS-321 DG

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

SUBJECT TO CHANGE WITHOUT NOTICE

MINI MCR-SL-PT100-UI-200

Displays Transducers. Displays and transducers

Universal Power Supplies

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Time Counters mini "h", DC Version

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

02/11/2015

Industrial Power Supplies

Industrial Power Supplies

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Installation / Control Technique

E-STOP relays, safety gate monitors

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Output Voltage* (nom.)(adjustable)

Contact protection relay

DATA SHEET IOM 200 analogue interface for AGC 200

Industrial Power Supplies

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

Installation Manual. Multi Power Controller MPC-1 multi-line D

Enclosed Power Supplies

Electronic monitoring relays PMDsrange

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

PHOENIX CONTACT Features

Digital Multifunction Meters. Digital Multifunction Meters

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Circuit diagram. Time ranges. Function. Function diagrams. Notes. Dimension diagram. Page 1

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

MIC-2 Multi-instrument DATA SHEET

MINI-PS AC/10-15DC/8

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

VariTrans P The Problem The variety of tasks results in a large number of different devices.

MINI MCR-SL-UI-REL(-SP)

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

MINI MCR-SL-CVS NC

Non-communicating room controllers

ASI QUINT /2.4 EFD

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

RTU500 series Data Sheet Power Supply CP-E 24/2.5

E-STOP relays, safety gate monitors

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

QUINT-PS/ 1AC/24DC/ 5

Huba Control. Pressure, vacuum and differential pressure transmitter. 0 3 / 5 / 10 / 30 / 50 mbar EDITION 12/2005

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

EngyVolt RV12 and RV15

QUINT-PS AC/24DC/10

VariTrans P Standard-Signal Isolators

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Datasheet - SRB 402EM-24V

Output Voltage* (nom.)(adjustable)

Power Supply HARTING pcon

XU1-DC DC voltage relay. (June 1998) Manual XU1-DC (Revision New)

Standard-Signal Isolation Amplifiers. VariTrans A 21000

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

Multifunction Transducer MT440

Data sheet. CI-TI TM Contactors and Motor Starters Timers ATI, BTI, MTI 520B1307

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A)

E-STOP relays, safety gate monitors

MINI MCR-SL-UI-2I(-SP)(-NC)

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

SPECIFICATIONS: PSAK650

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Power supply module, bus connection module

UNIVERSAL DIMMER DIM02SA/500U

Power Supply HARTING pcon

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

ISOMETER isopv with coupling device AGH-PV

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

STEP-PS/1AC/24DC/1.75

ETD-BL-1T-OFF-CC- 10S

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Power supply CP-C 24/5.0

Electronic timer CT-AHD.22

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Priva Blue ID Digital input module DI4/DI8/DI16

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Transcription:

Installation and start up instructions EM2020 Selectable AC transducer 4189300016A (UK) Watt or var transducer Supply and measuring voltage up to 690V Configuration via PC-interface possible FAGET 35 mm DIN rail or base mounting FAGET BV Tel.: ++31 (0) 521533333 Postbus 12, 8330AA Steenwijk Fax: ++31 (0) 521533398 Nederland E-mail: sales@faget.nl

Description EM2020 is a micro controller based power transducer with 1 analog output for measurement of Watt or var. The transducer holds no mechanical moving parts like potentiometers and therefore the calibration stability is excellent. Label The configured transducer is provided with a label with the following data: Coupling Type designation Faget s order ack. no. To be stated when contacting Faget Measuring range Primary values Condition of external voltage transformer Measuring range Secondary values Condition of external current transformer Output range Output limited to ±22mA Auxiliary voltage FAGET Max. output load current output Min. output load voltage output Distributor s ID Other information If. special product The un-configured transducer is provided with a label with the following data: Faget s order ack. no. can be found on a paper label on the transducerbox. About configuration see special manual. FAGET Page 2 of 8 Tel.: ++31(0)521 533333 Fax: ++31(0)521 533398 E-mail: sales@faget.nl

Installation and start up instructions, EM2020 Mounting instructions EM2020 is designed for panel mounting, being mounted on a 35 mm DIN rail, or by means of two 4-mm screws. Weight: Approx. 0.650 kg The design of the transducer makes mounting of it close to similar equipment possible, however make sure there is min. 50 mm between the top and bottom of the transducer and other equipment. The DIN rail must always be placed horizontally when several transducers are mounted on the same rail. 4189300016A (UK)

Connection diagram It is not necessary to protect the measuring voltage inputs. But it is recommended to use a 2A fuse for the supply input (terminals 1 and 3). The transducer is protected against ESD (electrostatic electricity), and further special protection against this during the mounting of the transducer is not necessary. Page 4 of 8 Tel.: ++31(0)521 533333 Fax: ++31(0)521 533398 E-mail: sales@faget.nl

Installation and start up instructions, EM2020 The voltage inputs are connected as follows, if the current transformers are placed in other phases than indicated in the above diagram: 2W3/2var3 External current transformer Connected to L1 (23 + 24) and L2 (29 + 30) Connected to L2 (23 + 24) and L3 (29 + 30) Connect L1 to term. no. 17 L2 to term. no. 17 L3 to term. no. 19 L1 to term. no. 19 L2 to term. no. 21 L3 to term. no. 21 Couplings 1W/1var and 1W4/1var4: Connect terminal no. 17 to the phase to which the external current transformer is connected. 1W3/1var3 External current transformer Connected to L2 Connected to L3 Connect L2 to term. no. 17 L3 to term. no. 17 L3 to term. no. 19 L1 to term. no. 19 L1 to term. no. 21 L2 to term. no. 21 Connection / set up The transducer is equipped with a red LED for indication of wrong phase connection or errors in the calibration / configuration. This LED is placed under the front plate. The function of the LED is as follows: Constant light. The wiring may be wrong. There is not equal power direction on all phases. There must be signal on all inputs to ensure correct testing and current flow in all phases. Note this function is only activated in coupling 2W3, 2var3 and 3W3(4), 3var3(4). Fast pulse 5Hz. The calibration data are corrupted. Contact Faget BV. Slow pulse 1Hz. The configuration data are wrong or corrupted. Make a reconfiguration or contact Faget BV. About configuration see special manual. 4189300016A (UK)

Opening of the unit The front panel is removed by means of a screwdriver. The front panel may be loosened in the right side first and is then totally demounted by moving the screwdriver towards left. Mounting of the front panel Press with a screwdriver as indicated by the arrow and press the front panel down with your thumb, simultaneously. It is recommended that one side of the front panel snaps into place before the other. Page 6 of 8 Tel.: ++31(0)521 533333 Fax: ++31(0)521 533398 E-mail: sales@faget.nl

Installation and start up instructions, EM2020 Technical specifications Accuracy: Class 0.5 (-10 15 30 55 C) according to IEC 60688 Meas. current (In) 0.75/1.5/3.0/6.0A Meas. range: 0 200% I n I n can be set between 0.375 6A Overload, currents: Load: Meas. voltage (Un): Overload, voltages: Load: Frequency range: Indication: Output: 20A max., continuously 75A max. for 10 s 240A max. for 1 s Max. 0.5VA per phase 73/140/254/400V phase to neutral Meas. range (U n): 30 120%U n (57...400V) U n can be set between 57 400V 127/240/440/690V phase to phase Meas. range(u n): 30 120%U n (100...690V) U n can be set between 100 690V 1.2 x U n max., continuously, 2 x U n max. for 10 s Min. 480kΩ 30 45 65 80Hz Note: For fundamental frequency (1. harmonic) outside 20Hz 80Hz the input is fixed to 0 Red LED function: (The LED is located behind the front plate) Incorrect wiring = constant light, only active for coupling 1W3, 2W3, 3W3(4) and 1var3, 2var3, 3var3(4) Calibration error = flash frequency 5Hz Configuration error = flash frequency 1Hz Other ranges possible 1 analog output Standard range: Output (0...100%): 0...1mA, 0...5mA, 0...10mA, 0...20mA, 0...1V, 0...5V, 0...10V Output (10...100%): 0.1...1mA, 0.5...5mA, 1...10mA, 2...20mA, 0.1...1V, 0.5...5V, 1...10V Output (20...100%): 0.2...1mA, 1...5mA, 2...10mA, 4...20mA, 0.2...1V, 1...5V, 2...10V Output (-100...0...100%): -1...0...1mA, -5...0...5mA, -10...0...10mA, -20...0...20mA, -1...0...1V, -5...0...5V, -10...0...10V 4189300016A (UK)

Limit: Max. ±120% of nominal output Output load: Current: Max. 10V (max. 1kΩ) Voltage: Max. 20mA Ambient temperature: -10 55 o C (nominal) -25 70 o C (operating) -40 70 o C (storage) Temperature coefficient: Max. ±0.2% of full scale per 10 C Response time: Ripple: Galvanic separation: Coupling 2W3/2var3, 3W3/3var3, 3W4/3var4 <225ms, typically 200ms Coupling 1W/1var, 1W3/1var3, 1W4/1var4 <150ms, typically 125ms Twice the class index according to IEC 60688 (1%pp) Between inputs, outputs and aux. supply: 3750V-50Hz-1 min. Supply voltage: 57.7-63.5-100-110-127-200-220-230-240-380-400-415-440- 450-660-690VAC ±20% 24-48-110-220VDC -25/+30% Consumption: (Aux. supply) 3.5VA/2W Climate: HSE, to DIN 40040 EMC: According to EN 50081-1/2, EN 50082-1/2 Protection: Housing: IP40. Terminals: IP20, to IEC 529 and EN 60529 Connections: Materials: Weight: Max. 2.5mm² multi-stranded Max. 4.0mm² single-stranded All plastic parts are self-extinguishing to UL94 (V1) 0.650kg Page 8 of 8 Tel.: ++31(0)521 533333 Fax: ++31(0)521 533398 E-mail: sales@faget.nl