Similar documents
BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives

SED2 Variable Frequency Drives

HVAC Products. Introducing the SED2 Variable Frequency Drives

Q9 ASD LOW VOLTAGE DRIVE

vacon 100 hvac for indoor climate control

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

5 MICROMASTER 420 specifications

A drive dedicated to variable speed control for HVAC applications

VFD 4x STAINLESS STEEL ENCLOSURE WITH AC. engineering data and specifications

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

PowerFlex 400 AC Drive Guide Specification

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

ADJUSTABLE SPEED DRIVES. Q9 Series

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

VLT 2800 DRIVE SPECIFICATIONS

ACH550 Product Overview

Built-in features Built-in simplicity Built for fans & pumps

Submittal Schedule Details for VFD-P101, P201, P202, P310, P302, P401, P402

Global Field Devices COMMERCIAL HVAC COMPONENTS ENGINEERED FOR SUCCESS. Application And Selection Guide

ABB Component Drives ACS55, 0.25 to 3 Hp

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

Master the elements in building automation siemens.com/sinamics-g120x

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

S-Flex Enclosed Drive

PowerXL DG1 Product Overview Eaton Corporation. All rights reserved.

5 MICROMASTER 440 specifications

Easy To Use OEMS Take Note

Technical Data and Specifications. Table 1. LCX9000 Specifications. Drive Efficiency > 95% Power Factor (Displacement).96

ENGINEERED SOLUTIONS. Solutions for Any Application. us.mitsubishielectric.com/fa/en/

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

SSW06. Soft Starters.

36.5. Adjustable Frequency Drives. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents Description H-Max Series Drives

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

S-Flex Enclosed drives

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog

SmartVFD HVAC and BYPASS

TR150 DRIVE STANDARD FEATURES

Submittal Data Information SmartDRIVE HVAC Variable Speed Drives

For additional PowerFlex 4M data and general drive information, refer to the following publications:

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

PowerFlex 40 Sample Specification

Submittal Data Information SmartDRIVE SP Variable Speed Drives

Submittal Data Information SmartDRIVE VP Variable Speed Drives

SED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

Affinity. Dedicated HVAC/R Drive for Building Automation. 1.1kW to 132kW (1.5hp to 200hp) 200V / 400V / 575V / 690V IP20 (NEMA 1) and IP54 (NEMA 12)

ACS Product Overview

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

CATALOG SELECTION / PRODUCT SELECTION

TR200 DRIVE WITH ELECTRONICALLY CONTROLLED BYPASS SYSTEM

AF-600FP Fan and Pump Drive

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Master the elements in water and wastewater applications siemens.com/sinamics-g120x

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

TR200 DRIVE STANDARD FEATURES

Andover ContinuumTM. b3850 Series Terminal Controllers

Unidrive M200 Integration through flexible communications

ABB Industrial Pump and Fan AC Drives ACS310, 0.5 to 30Hp (0.37 to 22kW)

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

P7BR. Description 5-500HP P7/Bypass NEMA 3R. Phone: Fax: Page Web: 61www.clrwtr.com -

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

SmartVFD HVAC232/402 GENERAL FEATURES SPECIFICATIONS. Frequency drives. Mains Connection Input voltage U in : Supply Network Networks:

Description 1/8-7.5HP

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

BuildingName The Description of the Project P DOCUMENTS

ADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:

AF-600 FP AC Drive AC Adjustable Frequency Drive Guide-Form Specification

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

PART 1: GENERAL PART 2: PRODUCT. Phone: Fax: Web: -

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

ATV1200A kv kva

Digistart. Soft starters for 3 phase induction motors 7.5 to 800kW (18 to 1600A) 200V, 400V, 575V, 690V

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ABB Industrial Pump and Fan AC Drives ACS310, 0.5 to 30Hp (0.37 to 22kW)

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

VLT The Real Drive for HVAC. The VLT 6000 is a. totally new adjustable. frequency drive, with. control functions and. software designed solely

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

INTRODUCING THE S V ADJUSTABLE SPEED DRIVE

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

SCC Inc. TS Series. Technical Instructions. Document No. TS-4000 March 10, TS-CE Combustion Enclosures with LMV5.

Operating comfort redefined Frequency Inverters M-MAX

Transcription:

Table of Contents Variable Frequency Drives PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE # Introduction C-3 NEW! BT300 HVAC Drives BT300 154-126 C-5 NEW! BT300 HVAC Drives with Bypass Options BT300 C-15 Legacy SED2 SED2 154-042 C-19 Legacy SED2 with Bypass Options SED2 154-044, 154-041 C-23 Legacy SED2 SED2 154-062 C-29 NEMA Type 3R & Type 3R Harsh Environment Bypass Accessories & Service Kits C-35 C-1

C-2

Introduction C-3 Siemens, a global leader in drives technology, is raising the bar with new BT300 Variable frequency Drives that are designed specifically for the demands of today s HVAC systems. Increased focus on energy efficiency of variable flow systems has increased the need for easy-to-use and highly reliable variable frequency drives that reduce the cost of installation and maintenance while maximizing energy savings. Siemens Industry s BT300 HVAC drives are designed to meet the demands of today s HVAC systems. An increased focus on energy efficiency of variable flow systems has increased the need for easy-to-use and highly reliable variable frequency drives that reduce the cost of installation and maintenance while maximizing energy savings. While constantly expected to do more with less, managing energy consumption and optimizing occupant comfort remains of utmost importance to facility managers. They also require products that will integrate seamlessly into existing equipment and building management systems. The highly efficient BT300 delivers all this and more. The BT300 comes standard with unique and industry-leading features: View/Monitor nine parameters at one time user selectable, users determine the parameters for their applications Thin Film Capacitors eliminate the need to condition or reform the capacitors before applying power Smallest Type 12 footprint on the market lower shipping cost and easy installation Motor Switch Ride Through during maintenance the motor maintenance switch can be opened and closed without stopping or tripping the drive

C-4 We re happy to assist you Our customer support teams are accessible and happy to assist you with ordering, fulfillment, and shipping questions. Call a representative at 1-800-516-9964 from 7 am to 5:30 pm (CST) Monday through Friday. Contact Customer Support or your Account Executive with any questions. We appreciate your business and look forward to helping you!

BT300 BT300 Variable Frequency Drives Energy & Atmosphere Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. BT300 without and with Integral Disconnect. Description Siemens Industry s BT300 HVAC drives are designed to meet the demands of today s HVAC systems. An increased focus on energy efficient variable flow systems has increased the need for easy-to-use and highly reliable variable frequency drives that reduce the cost of installation and maintenance while maximizing energy savings. HVAC demands are unique to other drive applications. Features Motor Switch Ride Through during maintenance the motor maintenance switch can be opened and closed without stopping or tripping the drive Thin Film Capacitors eliminate the need to condition or reform the capacitors before applying power Intuitive graphical keypad with multilingual display Monitor nine user-defined values at one time Built-in wizards for faster start-up and easy setup of advanced functions Built-in plain text help and maintenance manual shows possible causes and suggested remedies Real time clock allows up to five calendar-based schedules and three timer inputs Ready to communicate to a Building Management System, embedded RS485 and Ethernet HVAC protocols: BACnet IP, Modbus TCP, Modbus RTU, BACnet MSTP, Metasys N2, APOGEE FLN Two built-in PID controllers enable fast and accurate process control Integrated harmonic filters on the DC link reduce noise and interference and eliminate the need for additional filters and reactors Built in fire mode controller Energy Savings with > 97.5% efficiency Optimized cooling fan runs only when needed Belt failure detection with or without an external sensor Accepts a wide variety of digital and analog I/O types, including direct Ni 1000 RTD sensor level inputs One common interface throughout all power ranges Two form C relays RoHS Compliant Smallest Type 12 footprint on the market lower shipping cost and easy installation Options LON Interface Flange Mounting Kits for Frame Sizes 4-7 Varnished I/O Option Boards Door Mounting Kits PC Cable for NET Tool, USB to RS-485, cable length 9.8 ft. (3 m) Real Time Clock Battery Package SED2 to BT300 Migration Kits C-5

BT300 Specifications C-6 Input Voltage and Power Ranges (3-phase) 208V - 240V, +/-10%...1 to 125 HP (0.75 to 90 kw) 380V - 480V, +/-10%...1.5 to 250 HP (1.1 to 160 kw) Input Frequency... 45 to 66 Hz Output Frequency... 0 to 320 Hz Frequency Resolution... 0.01 Hz Power Factor... 0.98 at Nominal Load Efficiency... >97.5% Overload Capacity... 1.1 x Nominal Rated Output Current 110% for 1 Minute/10 Minutes Peak Overload Capacity...200% for 2 Seconds Every 20 Seconds Switching Frequency... 1.5 to 10kHz; Automatic Switching Frequency Derating in Case of Overheating Short Circuit Withstand Rating...100,000 AIC Frequency Reference Analog Input...0.01 Hz Resolution 0.1% (10-bit) Field Weakening Point... 8 to 320 Hz Acceleration/Deceleration Time...0.1 to 3000 sec Ambient Operating Temperature... -14º F (-10º C) no Frost to 104º F (40º C) Without De-rating and 131º F (55º C) With De-rating Storage Temperature...-40º F (-40º C) to 158º F (70º C) Relative Humidity...0 to 95% RH, Non-condensing, Non-corrosive Air Quality... IEC 60068-2-60 Chemical Vapors...IEC 60721-3-3, Unit in Operation, Class 3C3 Mechanical Particles...IEC 60721-3-3, Unit in Operation, Class 3S2 Altitude...100% Load Capacity (no De-rating) up to 3,280 ft (1,000 m) 1% De-rating for Each 328 ft (100 m) Above 328 ft (1,000 m) Maximum Altitude 14,763 ft (4,500 m) Vibration...IEC 61800-5-1 and IEC 60068-2-6 Shock...IEC 61800-5-1 and IEC 60068-2-27 Enclosures... UL Type 1, UL Type 12 EMC Immunity...Fulfills IEC 61800-3, First and Second Environment EMC Emissions...EN61800-3C2 Average Noise level (Cooling Fan) Sound Level in db(a)...fs4-65; FS5-61; FS6 and FS7: 68 FR8: 77; FR9: 78 Agency Approvals...UL 508C; CE, UL, cul Analog Inputs... 2 Voltage or Current (0-10Vdc, 0/4 to 20 ma) Analog Output...1 Selectable Voltage or Current Digital Inputs... 6 Programmable and Isolated Relay Outputs...2 Form C; 1 Normally Open Auxiliary Input Voltage...24 Vdc +/-10% 250 ma Max. Auxiliary Input Voltage...24 Vdc +/-10% 250 ma Max., Total of Both Outputs Control Method...Linear, Parabolic and Programmable V/f; Flux Current Control Low-Power Mode PWM Frequency... 2k Hz to 16k Hz (Adjustable in 2k Hz Increments) Fixed Frequencies...15 Programmable Skip Frequency Bands...3 Programmable Embedded Resident Protocols...RS485 and Ethernet P1, BACnet MS/TP, BACnet IP, Modbus RTU, Modbus TCP, Metasys N2, APOGEE FLN Protection Features...Under-voltage and Over-voltage Trip Limit, Ground Fault, Mains Supervision, Motor Phase Supervision, Over-current, Unit Over-temperature, Motor Overload, Motor Stall, Motor Underload, Short Circuit of +24V and +10V Reference Voltages Accessories & Service Kits C-35

BT300 Product Ordering Your Product Number Example Product Number B T 3 0 0-0 0 1 X 2-0 1 X Example Product Number B T 3 0 0-0 0 1 5 4-1 2 D L Model BT300 VFD only HP 1, 1.5, 2, 3, 5, 7.5, 10, 15 20, 25, 30, 40, 50, 60, 75 100, 125, 150, 200, 250 X No Fract HP, 5 1/2 HP Voltage 2 200 to 240 4 380 to 480 NEMA 01 UL Type 1 12 UL Type 12 Type X Drive Only D Disconnect Box ONLY WITH TYPE 12 Options L LON Card Installed C-7 Example Shown: BT300-001X2-01X = 1 HP, 208V Drive in Type 1 enclosure. BT300-00154-12DL = 1.5 HP, 480V Drive in Type 12 enclosure with an integral disconnect switch and LON card.

BT300 Output Ratings C-8 Voltage (±10%) 208V (3-Phase) 230V (3-Phase) 380V to 480V (3-Phase) Product Number Output Rating Rated UL Type 12 with Continuous UL Type 1 UL Type 12 HP kw Drive Disconnect Current BT300-001X2-01X BT300-001X2-12X BT300-001X2-12D 1.0 0.75 4.8 FS4 BT300-00152-01X BT300-00152-12X BT300-00152-12D 1.5 1.1 6.7 FS4 BT300-002X2-01X BT300-002X2-12X BT300-002X2-12D 2.0 1.5 8.0 FS4 BT300-003X2-01X BT300-003X2-12X BT300-003X2-12D 3.0 2.2 11.0 FS4 BT300-005X2-01X BT300-005X2-12X BT300-005X2-12D 5.0 4.0 18.0 FS5 BT300-00752-01X BT300-00752-12X BT300-00752-12D 7.5 5.5 24.0 FS5 BT300-010X2-01X BT300-010X2-12X BT300-010X2-12D 10.0 7.5 31.0 FS5 BT300-015X2-01X BT300-015X2-12X BT300-015X2-12D 15.0 11.0 48.0 FS6 BT300-020X2-01X BT300-020X2-12X BT300-020X2-12D 20.0 15.0 62.0 FS6 BT300-025X2-01X BT300-025X2-12X BT300-025X2-12D 25.0 18.5 75.0 FS7 BT300-030X2-01X BT300-030X2-12X BT300-030X2-12D 30.0 22.0 88.0 FS7 BT300-040X2-01X BT300-040X2-12X BT300-040X2-12D 40.0 30.0 105.0 FS7 BT300-050X2-01X BT300-050X2-12X 50.0 37.0 140.0 FS8 BT300-060X2-01X BT300-060X2-12X 60.0 45.0 170.0 FS8 BT300-075X2-01X BT300-075X2-12X 75.0 55.0 205.0 FS8 BT300-100X2-01X BT300-100X2-12X 100.0 75.0 261.0 FS9 BT300-125X2-01X BT300-125X2-12X 125.0 90.0 310.0 FS9 BT300-00154-01X BT300-00154-12X BT300-00152-12D 1.5 1.1 3.7 FS4 BT300-002X4-01X BT300-002X4-12X BT300-002X4-12D 2.0 1.5 5.3 FS4 BT300-003X4-01X BT300-003X4-12X BT300-003X4-12D 3.0 2.2 6.2 FS4 BT300-005X4-01X BT300-005X4-12X BT300-005X4-12D 5.0 4.0 10.6 FS4 BT300-00754-01X BT300-00754-12X BT300-00752-12D 7.5 5.5 13.2 FS4 BT300-010X4-01X BT300-010X4-12X BT300-010X4-12D 10.0 7.5 16.0 FS5 BT300-015X4-01X BT300-015X4-12X BT300-015X4-12D 15.0 11.0 23.0 FS5 BT300-020X4-01X BT300-020X4-12X BT300-020X4-12D 20.0 15.0 31.0 FS5 BT300-025X4-01X BT300-025X4-12X BT300-025X4-12D 25.0 18.5 38.0 FS6 BT300-030X4-01X BT300-030X4-12X BT300-030X4-12D 30.0 22.0 46.0 FS6 BT300-040X4-01X BT300-040X4-12X BT300-040X4-12D 40.0 30.0 61.0 FS6 BT300-050X4-01X BT300-050X4-12X BT300-050X4-12D 50.0 37.0 72.0 FS7 BT300-060X4-01X BT300-060X4-12X BT300-060X4-12D 60.0 45.0 87.0 FS7 BT300-075X4-01X BT300-075X4-12X BT300-075X4-12D 75.0 55.0 105.0 FS7 BT300-100X4-01X BT300-100X4-12X 100.0 75.0 140.0 FS8 BT300-125X4-01X BT300-125X4-12X 125.0 90.0 170.0 FS8 BT300-150X4-01X BT300-150X4-12X 150.0 110.0 205.0 FS8 BT300-200X4-01X BT300-200X4-12X 200.0 132.0 261.0 FS9 Frame Size BT300-250X4-01X BT300-250X4-12X 250.0 160.0 310.0 FS9

BT300 Type 1 and 12 Frame Sizes and Power Range Voltage KW 0.75 1.1 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 HP 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 208V Frame Size 4 5 6 7 8 9 NA 480V N/A 4 5 6 7 8 9 BT300 Dimensions and Weights Frame Size Height in. (mm) Width in. (mm Depth in. (mm (without Disconnect) Depth in. (mm (with Disconnect) Weight lb. (kg) FS4 12.9 (328) 5.0 (128) 7.5 (190) 10.6 (270) 13.0 (6) FS5 16.5 (419) 5.7 (144) 8.4 (214) 11.6 (294) 22.0 (10) FS6 21.9 (557) 7.7 (195) 9.0 (229) 11.9 (302) 44.0 (20) FS7 26.0 (660) 9.3 (237) 10.2 (259) 13.1 (332) 83.0 (37.5) FS8 38.0 (966) 11.4 (290) 13.5 (343) N/A 145.5 (66) FS9 45.3 (1150) 18.9 (480) 14.4 (365) N/A 238.0 (108) C-9

BT300 Dimensions FS4, Wall-Mount Type 1/IP21 Ø7 (.27) Ø13 (.51) 128(5.03) 100(3.93) 190(7.48) Ø25 (.98) 313 (12.32) 151 (5.94) 112 (4.40) 328 (12.91) Type 12 /IP54 Ø25 (.98) C-10 112 (4.40) 147 (5.78) mm (in.) 100(3.93) BT9080 FS5, Wall-Mount

BT300 Dimensions FS6, Wall-Mount Ø9 (.35) 195 (7.67) 148 (5.82) Ø 15,5(.61) 229(9.01) Ø33 (1.29) Ø40 (1.57) Ø40 (1.57) 43,7 (1.72) 557 (21.92) 148 (5.82) 541 (21.29) 151 (5.94) Type 1/IP21 Ø25 (.98) Ø25 (.98) 148 (5.82) 42 (1.65) 151 (5.94) C-11 mm (in) Ø9 (.35) 259 (10.19) Ø20 (.78) 148 (5.82) 660 (25.98) FS7, Wall-Mount 237 (9.33) 190 (7.48) Ø9 (.35) Ø16 (.62) 645 (25.39) Ø51 (2) Type 12 /IP54 Type 1 / IP21 Type 12 / IP54 BT9082 160 (6.29) 211 (8.30) Ø25 (.98) Ø50 (1.96) 160 (6.29) 217 (8.54) 9083bt mm (in)

BT300 Dimensions FS8, Wall-Mount C-12

BT300 Dimensions FS9, Wall-Mount C-13

C-14 Online 24/7 ordering convenience Use this Master HVAC Catalog and Siemens online ordering to maximize ordering efficiency. Go online to: Place orders Browse this catalog online Check product availability and pricing Specify FREE valve tagging Download invoices Track shipments Print out product information for submittals Link to technical documentation Download installation instructions Create a reusable template order form for frequently ordered parts See how easy it is to save time and money. Register today at: www.usa.siemens.com/buildingtechnologiesonlineordering

BT300 BT300 with Bypass Options Energy & Atmosphere Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. BT300 with Bypass Options. Description The BT300 was designed from the onset with reliability in mind. The BT300 is the first VFD in today s market which has utilized ALT testing from product design to production deployment. However in today s market, some customers want additional assurance their equipment will run regardless of the situation. To accommodate these situations, Siemens has developed a companion product for the BT300, the BT300 with Bypass Options. As the word indicates, a bypass is defined in an engineering spec as a means of taking the drive out of the electrical power loop while keeping the HVAC system up and running. BT300 is available with two types of bypass options. The BT300 with Conventional bypass is designed with 2 contactors and a service switch or the traditional 3-contactor configuration to bypass the drive, and incorporates selector switches and indicator lights to accomplish its primary functions. The second option, an Electronic bypass utilizes internal control boards that act as the brains and eliminates the control wiring, relay logic, terminal blocks and replaces them with advanced built-in features accessible from an electronic keypad. Features Contactors electronically interlocked Advanced diagnostic board built into the bypass for determining status of M1 and M2 contactors Overload Customer supplied start/stop Status of Essential Services Step-down transformer with fused primary and thermal fused secondary circuit Fused disconnect or circuit breaker Option 100,000 AIC short circuit rating Customer Supplied Terminal strip Conventional Bypass Control: Drive test switch Drive-Off-Bypass selector Bypass Light Fused disconnect or circuit breaker Optional 2-contactor with service switch or 3-contactor design (input, output and bypass) Electronic Bypass Control Auto Bypass Option to install 8 separate safety circuits Fieldbus in Bypass Essential Service Mode (Fire mode) Damper Interlock Remote start via network C-15

BT300 with Bypass Options Product Ordering C-16 Your Product Number Example Product Number B T E - 1 2 5 X 4 - B 0 1 2 L Model(s) HP BTC BTE 1, 1.5, 2, 3, 5, 7.5,10,15 20, 25, 30, 40, 50, 60, 75 100, 125, 150, 200, 250 X=no fract HP 5= 1/2 hp Voltage Disconnect Conventional Electronic 2 200 to 240 4 380 to 480 F B Enclosure Contactor Options Fused Disconnect Circuit Breaker 01 Enclosure Type 1 3 3 contactors (input/output and bypass contactors) (Conventional option only) 2 2 contactors bypass with service switch L Lon Card Installed Example shown: BTE -125X4 -B012L BT300 Electronic Bypass, 480 volt, 125hp, Type 1, circuit breaker and 2 Contactor bypass with a service switch and LonWorks card installed in drive BT300 Bypass Options Frame Sizes and Power Ranges Voltage KW 0.75 1.1 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 HP 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 208V Frame Size 4 5 6 7 8 9 NA 480V N/A 4 5 6 7 8 9 Type 1 Bypass Approximate Weights Frame Size 4 5 6 7 8 and 9 Weight lbs. (kg) 50 (23) 69 (31) 112 (51) 187 (85) 1000 (454)

BT300 Bypass Options Dimensions Frame Size 4.38 MOUNTING HOLES TYPICAL (4) PLACES 35.48 34.625 1/2" CONDUIT HOLE WITH 3/4" KNOCKOUT RING TYPICAL (5) PLACES Frame Size 6.44 MOUNTING HOLES TYPICAL (4) PLACES.38 1.49 4.000 6.76 C-17 54.75 44.10 43.250 Frame Size 5.38 MOUNTING HOLES TYPICAL (4) PLACES 1/2" CONDUIT HOLE WITH 3/4" KNOCKOUT RING TYPICAL (3) PLACES.50 53.750 1.49 6.000 8.76 1/2" CONDUIT HOLE WITH 3/4" KNOCKOUT RING TYPICAL (3) PLACES 3/4" CONDUIT HOLE WITH 1" KNOCKOUT RING TYPICAL (2) PLACES 1-1/4" CONDUIT HOLE WITH 1-1/2" KNOCKOUT RING TYPICAL (2) PLACES.38 1.49 4.000 6.76

BT300 Bypass Options Dimensions Frame Size 7 Frame Size 8 & 9.50 MOUNTING HOLES TYPICAL (4) PLACES TOP ENTRY, BLANK CONDUIT PLATES 58.50 57.375 1.18 TYPICAL (4) PLACES C-18.50 4.18 6.000 14.16 1/2" CONDUIT HOLE WITH 3/4" KNOCKOUT RING TYPICAL (3) PLACES 2" CONDUIT HOLE WITH 2-1/2" KNOCKOUT RING TYPICAL (2) PLACES 92.99 90.71 32.58 (TYPE 1 & 12) 1.28 29.409 29.409.94 (4) PLACES TYPICAL

SED2 Legacy Variable Frequency Drives Energy & Atmosphere Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. SED2 Family. Features Built-in SBT P1 and JCI N2 (Metasys ) building automation system protocols for easy network integration LON, Modbus RTU Interfaces optional Low harmonics design reduces noise and interference; eliminates need for filters/reactors in most installations Built-in PID for fast and accurate pressure control Pump staging for open loop, constant pressure, and constant flow-type applications Multi-level program access Belt failure detection with or without an external sensor Service mode for applications requiring continuous, uninterruptible operation Accepts a wide variety of digital and analog I/O types, including direct Siemens Ni 1000 RTD sensor level inputs One common interface throughout all power ranges Optional Advanced Operator Panel for uploading/ downloading parameters Full form C relay contacts for digital outputs Options LON Interface Modbus RTU Interface Advanced Operator Panel (AOP) Module PC Kit C-19

Specifications C-20 Input Voltage and Power Ranges (3 phase) 208V and 230V to 240V, 3 ac±10%...1 hp to 60 hp 380V to 480V, 3 ac ±10%...1 hp to 125 hp 500V to 600V, 3 ac ±10%...1 hp to 125 hp Input Frequency...47 Hz to 63 Hz Output Frequency...0 Hz to 150 Hz Power Factor... 0.9 VFD degree of efficiency... 96% to 97% Switch-on Current... Less than nominal input current Auxiliary Supply 24V... Glavanically separated, unregulated auxiliary supply (18V to 32V) 100 ma Overload Capacity...110% for 60 seconds Control Method...Linear, parabolic and programmable V/f; and flux current control low-power mode PWM Frequency...2k Hz to 16k Hz (adjustable in 2k Hz increments) Fixed Frequencies... 15 programmable Skip Frequency Bands... 4 programmable Setpoint Resolution...0.01 Hz digital 0.01 Hz serial 10 bit analog Digital Inputs (Sink/Source)...6: fully programmable and scalable isolated digital inputs, switchable Analog Inputs...2: 0 to 10 Vdc, 0/4 to 20 ma, can also be configured as digital inputs or Ni 1000 input Relay Outputs...2: configurable 30 Vdc/5A (resistive), 250 Vac/2A (inductive) Analog Outputs...2: programmable (0/4 ma to 20 ma, or 0 Vdc to 10 Vdc) Serial Interface...RS-485 transmission rate: Up to 38.4k Baud Protocols: USS, P1 and N2 Protection Level... IP20 NEMA Type 1 with protective shield and gland plate installed Temperature Ranges...Operating: 14 F to 104 F ( 10 C to 40 C) Storage: 40 F to 158 F ( 40 C to 70 C) Humidity...95% rh, non-condensing Operational Altitudes...Up to 3280 ft (1000m) above sea level without derating Protection Features...Under-voltage, Over-voltage, Overload, Ground fault, Short circuit, Stall prevention, Locked motor, Motor overtemperature l 2 t PTC, Over-temperature, Parameter PIN protection. Standards... UL, cul, CE, C-tick CE Conformity...Conformity with EC Low Voltage Directive 73/23/EEC Options...LON Interface, Modbus RTU Interface, BACnet MS/TP Interface, Advanced Operator Panel (AOP) Module, PC Kit Product Ordering Your Product Number Example Product Number S E D 2-0. 7 5 / 2 2 X Model SED2- kw rating VFD only 0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 90 [See Note 1 for these selections] Voltage 2 200 to 240V 3 380 to 480V 4 500 to 600V (Uses 2 to 4 spaces plus a divider / ) NEMA rating 2 (IP 20) 1 NEMA Type 1 Filter X Factory Required Designator Notes: Example Shown: 1. Available only with Voltage Codes 3 and 4. SED2-0.75/22X = SED2 VFD only, 0.75 kw (1 hp), 200 to 240V, open type IP20.

Frame Sizes SED2 IP20 and NEMA Type 1 Frame Sizes and Power Ranges VFD0163R1 HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kw.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 240V A B C D E F N/A 480V A B C 575V C D E F Dimensions and Weights IP20 SED2 VFDs Frame Size Height Width Depth Weight Lb. (kg) A 6.8 (173) 2.9 (73) 5.9 (149) 2.9 (1.3) B 8.0 (202) 5.9 (149) 6.8 (172) 7.5 (3.4) C 9.6 (245) 7.3 (185) 7.7 (195) 12 (5.5) D 20.5 (520) 10.8 (275) 9.6 (245) 35 (16) E 25.6 (650) 10.8 (275) 9.6 (245) 44 (20) F 33.5 (850) 13 (350) 12.6 (320) 116 (53) C-21 NEMA Type 1 SED2 VFDs Assembled with Protective Shield and Gland Plate Frame Size Height Width Depth Weight Lb. (kg) A 9.1 (231) 2.9 (73) 5.9 (149) 3.2 (1.5) B 11.8 (300) 5.9 (149) 6.8 (172) 8.3 (3.8) C 13.8 (351) 7.3 (185) 7.7 (195) 13.6 (6.2) D 24.6 (625) 10.8 (275) 9.6 (245) 37.5 (17) E 29.7 (754) 10.8 (275) 9.6 (245) 46.4 (21) F 54.5 (1384) 16.0 (406) 14.0 (356) 200 (91)

C-22 Online order tracking This handy online feature stores all your past and current orders online for quick and easy reference. The Order Tracker function lets you access information such as: Ordered By Order No. Shipping Date Date Placed Acknowledgement of Order Shipment Tracking To view your history and status, register online at www.usa.siemens.com/buildingtechnologiesonlineordering

SED2 Legacy with Bypass Options Energy & Atmosphere Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. SED2 with Conventional Bypass Options Family. Bypass Power 3-Contactor: Input, Output, & Bypass Overload protection in bypass mode Step-down transformer with fused primary and secondary Contactors electrically and mechanically interlocked Drive test function Complete electrical isolation of drive Input Device Fused disconnect Circuit breaker (optional) All doors are interlocked and padlockable Reactor Options Input line reactor mounted in bypass option enclosure. Line reactor supplied separately. Load reactor (in NEMA 1/3R enclosure) supplied separately. E-Bypass Control Auto Bypass Relay logic allows user to send the motor to bypass mode based on the drive s programmable relay. The drive s programmable relay, typically set to fault, can be set up for applications that run full speed for an extended period of time. put evice Drive Motor 3 Contactor Bypass Input Device Essential Services Mode Also used for smoke purge; the motor goes to bypass regardless of the selected mode. No call to stop will have an effect, including open safety or stop commands. Only turning the power off or opening this contact will stop the motor. Conventional Bypass Control Enable Input Generally used for safety tie-ins; the motor will not operate the drive or bypass when open. Essential Services Mode Typically used for smoke purge; the motor goes to bypass regardless of the selected mode. No call to stop will have an effect, including open safety or stop commands. Only turning the power off or opening this contact will stop the motor. Conventional Bypass Door Mounted Control Devices Drive-Off-Bypass selector Bypass pilot light Drive Test on/off selector C-23 Enable Input Generally used for safety tie-ins; the motor will not operate the drive or bypass when open. Common Remote Start/Stop Common remote start/stop can be used in both drive and bypass mode.

with Conventional Bypass Option Specifications Electronic Bypass Specifications Input Voltage (3-phase) 208V, 3 AC±10%...1 hp to 60 hp (2.3 amps to 154 amps) 240V, 3 AC±10%...1 hp to 60 hp (2.3 amps to 154 amps) 480V, 3 AC ±10%...1 hp to 125 hp (1.2 amps to 178 amps) 575V, 3 AC ±10%...1 hp to 125 hp (2.3 amps to 125 amps) Protection Level...NEMA Type 1 Digital Inputs Six Digital Inputs as follows...remote start input, Remote safety 1, Remote safety 2, Interlock start, Essential services, Overload trigger. Inputs require a contact closure capable of providing a low impedance path at currents less than 20 ma. Relay/Digital Outputs Six Relay/Digital Outputs as follows...vfd fault, Programmable output, Drive select, Bypass select, Running on bypass, Overload fault, Each relay has a maximum rating of 2A at 120Vac. Conventional Bypass Specifications Input Voltage (3-phase) 208V, 3 AC±10%...1 hp to 60 hp (2.3 amps to 154 amps) 240V, 3 AC±10%...1 hp to 60 hp (2.3 amps to 154 amps) 480V, 3 AC ±10%...1 hp to 125 hp (1.2 amps to 178 amps) 575V, 3 AC ±10%...1 hp to 125 hp (2.3 amps to 125 amps) Protection Level...NEMA Type 1 Temperature Operating... 32 to 104 F (0 to +40 C) Storage...-40 to +158 F (-40 to +70 C) Humidity...0 to 95% RH, non-condensing E-Bypass Door Mounted Control Devices C-24 VFD Bypass VFD0097R2 Input On/Off Enable STOP RESET VFD Input Contactor Output Contactor Bypass Contactor Motor Auto Bypass Enabled Essential Services Overload Relay Hand Start Remote Start VFD Fault Safety Fault Overload Fault Enable Commanded Proofed INTERLOCK START LOGIC Accessories & Service Kits C-35

Legacy with Conventional Bypass Option Product Ordering Your Product Number Example Product Number V B A 3 4 0. B 1 3 3 X Model VB VFD with an Extended Box Series A E Conventional Bypass Electronic Bypass Voltage HP rating 1 208 V 2 230 to 240 V 3 380 to 480 V 4 500 to 600 V 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 100, 125 [See Note 1 for these selections] Disconnect F B Fused Disconnect Circuit Breaker C-25 NEMA rating 1 NEMA Type 1 Contactor Notes: 3 3 Contactors (Input, output, and bypass contactors) 0 None (Extended box only. No bypass.) Reactor [See Note 3] 0 None 3 Line Reactor Filter X Factory Required Designator 1. Available only with Voltage Codes 3 and 4. 2. Input line reactors will be installed in bypass enclosures. Load reactors are supplied seperately in NEMA 1 or NEMA 3R enclosures. Example shown: VBA340.B133X VBA Conventional Bypass, 40 HP, 480V, Circuit Breaker, NEMA Type 1, 3-Contactor Bypass with Input Line Reactor. VBE340.F130X VBE Electronic Bypass, 40 hp, 480V, fused disconnect, NEMA Type 1, 3 contactors bypass, no reactor.

NEMA 1 Bypass Approximate Weights Frame Size Wt. Lb (kg) A 45 (20) B 55 (25) C 75 (34) D 150 (68) E 180 (82) F 470 (213) Note: Exact weight will be affected by the actual horsepower/voltage and the selected power options. NEMA 1 Bypass Frame Sizes and Power Ranges C-26 HP kw 208/240V 480V 575V 1.75 A 1.5 1.1 A 2 1.5 B 3 2.2 B 5 4 C 7.5 5.5 C 10 7.5 15 11 C 20 15 D 25 18.5 30 22 E D D 40 30 50 37 F 60 45 E E 75 55 100 75 F N/A F 125 90 HA1 N/A

NEMA 1 Dimensions Depth With Handle 9.6 (24) = Protective Shield 13.2 (34) 1.5 (3.8) Depth With Handle 9.6 (24) 11.5 (29) Depth With Handle 1 10.4 (26) (2.5) 2 (5) 20.8 (53) 2.9 (7.4) 4 (10) 34 (86) 10.5 TYP (27) 48 (122) 11 TYP (28) 53.5 (136) 11.5 TYP (29) 12.4 (31) 1.5 (3.8) 10.6 (27) 2 (5) 19.9 (51) 3.4 (8.6) Frame Size A and B Frame Size C Frame Size D C-27 Depth With Handle 12.2 (31) 58.5 (149) 20.8 (53) 2.9 (7.4) 3 (7.6) 10 TYP (25) 57.5 (146) 45.5 (116) Depth 17.4 (44) VFD0127R2 19.9 (51) Frame Size E 5.5 (14) Frame Size F Dimensions shown in inches (mm).

C-28 We re happy to assist you Our customer support teams are accessible and happy to assist you with ordering, fulfillment, and shipping questions. Call a representative at 1-800-516-9964 from 7 am to 5:30 pm (CST) Monday through Friday. Contact Customer Support or your Account Executive with any questions. We appreciate your business and look forward to helping you!

SED2 Legacy VFD NEMA Type 3R & Type 3R Harsh Environment (3RHE) Bypass Energy & Atmosphere Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. SED2 NEMA Type 3R Bypass. Features Bypass Power 3-Contactor: Input, Output, and Bypass Overload protection in bypass mode. Step-down transformer with fused primary and secondary. Contactors electrically and mechanically interlocked. Drive test function. Complete electrical isolation of drive. Input Device Fused disconnect. All doors are interlocked and padlockable. Reactor Options Line reactor mounted in bypass enclosure. Line reactor supplied separately (in NEMA Type 3R enclosure). Load reactor supplied separately. Bypass Door Mounted Control Devices Drive-Off-Bypass selector Bypass pilot light Drive Test On-Off selector C-29

NEMA Type 3R/3RHE Bypass Specifications Input Voltage (3 phase)... 208V, 3 AC ±10% * 240V, 3 AC ±10% * 480V, 3 AC ±10% 575V, 3 AC ±10%* * Not available in the 3RHE models Protection Level...NEMA Type 3R Temperature Operating...14 F to 104 F ( 10 C to 40 C), HT1 to 122 F (50 C) Storage... 40 F to 158 F ( 40 C to 70 C) High-Temperature Model (HT1 and HT2) Operating...14 F to 122 F ( 10 C to 50 C) Storage... 40 F to 158 F ( 40 C to 70 C) Humidity...0 to 95% rh, non-condensing C-30

VFD NEMA Type 3R & Type 3R Harsh Environment (3RHE) Bypass Product Ordering Your Product Number Example Product Number V B A 3 4 0. F 3 3 0 X H E 2 Model VB VFD with an Extended Box Series A Conventional Bypass Voltage 1 208 V 2 230 to 240 V 3 380 to 480 V 4 500 to 600 V HP rating Disconnect F 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 100, 125 [See Note 1 for these selections] Fused Disconnect C-31 NEMA rating 3 NEMA Type 3R Contactor 0 None 3 3 Contactors (Input, output, and bypass) Reactor [See Note 2] 0 None 3 Line Reactor Filter X Factory Required Designator Options (If no option is required, leave field blank) HT1 High Temperature [See note 3] HE2 Harsh Enviroment Nema 3R [See note 4] HT2 Harsh Enviroment Nema 3R High Temperature Rating [See note 5] Notes: 1. Available only with Voltage Codes 3 and 4. 2. Input line reactors will be installed in bypass enclosures. Load reactors are supplied seperately in NEMA 1 or NEMA 3R enclosures. 3. HT1 (122 F, 50 C) is not available for all ratings. 208V and 230 to 240V to 3 hp are all HT1; 480V to 5 hp are all HT1. 4. HE2 available only with Voltage Codes 3 and 4. (480V to 40 hp) 5. HT2 (122 F, 50 C) is not available for all ratings. 480V to 5 hp are all HT2 Example Shown: VBA340.F330XHE2 VBA Conventional Bypass, 480V, 40 hp, fused disconnect, NEMA Type 3R, 3 contactors, no reactor, harsh environment.

NEMA Type 3R Enclosure Dimensions Enclosure Frame ABC Enclosure Frame DE Enclosure Frame F 34 (864) 18 (457) 46 (1169) 30 (762) 58 (1473) 42 (1067) 30 (762) 28-1/2 (724) Depth = DEPTH 11-1/2 = Inches 11-1/2 (292) 57 (1448) 56-1/8 (1425) 75 (1905) 74-1/8 (1882) C-32 VFD0178R2 MOUNTING CLEARANCE Depth DEPTH = 12-1/2 = 12-1/2 Inches (318) (318) FOR PROPER AIRFLOW: LEAVE 1 FOOT (305 mm) BETWEEN THE NEMA TYPE 3R BYPASS AND ANY ADJACENT SOLID STRUCTURE THAT IS NOT USED FOR MOUNTING PURPOSES. LEAVE 3 FEET (914 mm) BETWEEN THE NEMA TYPE 3R BYPASS AND ANY OTHER NEMA TYPE 3R BYPASS OR VFD. Depth = DEPTH 16-1/2 = Inches 16-1/2 (419) NEMA Type 3RHE Enclosure Dimensions 30 (756) 29 (724) Enclosure Frame B Enclosure Frame C Enclosure Frame D 34 (848) 18 (457) 51 (1288) 50 (1272) 42 (1051) 26 (660) 57 (1440) 56 (1424) 44 (1099) 28 (711) VFD0222R1 VFD0225R1 VFD0228R1 Depth = 10 Inches Depth = 11 Inches Depth = 14 Inches Dimensions shown in inches (mm).

NEMA Type 3R and 3RHE Approximate Weights 3R Frame Size Wt. Lb (kg) 3RHE Frame Size Wt. Lb (kg) ABC 130 (59) B 150 (68) DE 300 (136) C 220 (100) F 550 (249) D 330 (150) Note: Exact weight will be affected by actual horsepower/voltage and selected power options VFD0179R2 NEMA Type 3R Bypass Non-HT1 Enclosure Frame Sizes and Power Ranges HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kw.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 208/240V 480V (Rated as HT1, High Temperature package) (Rated as HT1, High Temperature package) ABC DE F N/A ABC DE F 575V ABC DE F C-33 VFD0180R2 VFD0180R2 NEMA Type 3R Bypass HT1 Enclosure Frame Sizes and Power Ranges HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kw.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 208/240V ABC DE F N/A 480V ABC DE F N/A 575V ABC DE F N/A NEMA 3RHE Bypasses HE2 Frame Sizes and Power Ranges HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kw.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 208/240V N/A 480V N/A C D N/A 575V N/A NEMA 3RHE Bypasses HT2 Frame Sizes and Power Ranges VFD0180R2 HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kw.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 208/240V N/A 480V N/A B C D N/A 575V N/A

C-34 Online 24/7 ordering convenience Use this Master HVAC Catalog and Siemens online ordering to maximize ordering efficiency. Go online to: Place orders Browse this catalog online Check product availability and pricing Specify FREE valve tagging Download invoices Track shipments Print out product information for submittals Link to technical documentation Download installation instructions Create a reusable template order form for frequently ordered parts See how easy it is to save time and money. Register today at: www.usa.siemens.com/buildingtechnologiesonlineordering

Table of Contents Accessories & Service Kits PRODUCT PAGE # BT300 NEW! PC Cable for Software Tools C-36 Real Time Clock Battery Package C-36 Door Panel Kit C-36 Hand Held Panel Kit C-36 Flange Mounting Kits C-36 Varnished Option Boards C-37 SED2 to BT300 Migration Kits C-38 SED2 PC Kit C-39 C-35 Mounting Hardware C-39 Filter Kits C-39 Operator Panel C-39 LON Interface Option C-40 Modbus Interface C-40

Accessories and Service Kits BT300 Description PC Cable for Software Tools, USB to RS-485, 3m Part No. BT300-CABLE Battery package, 5 pcs BT300-BATTERY Door Panel Kit, Drive Side IP54 Protected, 3m BT300-PANEL-N12 C-36 Hand Held Panel Kit Flange Mounting Kit, for FS4 Flange Mounting Kit, for FS5 Flange Mounting Kit, for FS6 Flange Mounting Kit, for FS7 BT300-HHPANEL BT300-FLG-FS4 BT300-FLG-FS5 BT300-FLG-FS6 BT300-FLG-FS7

BT300 Description Part No. 6 X DI/DO, Programmable BT300-OPT-B1-V 2 X RO + Thermistor BT300-OPT-B2-V 1 X AI, 2 X AO (Isolated) BT300-OPT-B4-V 3 X RO BT300-OPT-B5-V C-37 1 X RO, 5 X DI (42-240VAC) BT300-OPT-B9-V LonWorks BT300-OPT-C4-V 1xAO, 1xDO, 1xRO BT300-OPT-BF-V NI1000 Sensor Card BT300-OPT-BH-V

Accessories and Service Kits BT300 Description SED2 208V to 3HP 480V to 5HP Part No. SED2-BT300-AB-4 SED2 208V to 4HP 480V to 7.5HP SED2-BT300-C-4 SED2 208V to 10HP 480V to 20HP SED2-BT300-C-5 C-38 SED2 208V 15 to 20hp 480V 25 to 40hp SED2-BT300-D-6 SED2 208V 25hp SED2 208V 30hp 480V 50 to 60hp SED2 FSC to BT300 Remote Mount SED2-BT300-D-7 SED2-BT300-E-7 SED2-BT300-C-R SED2 FSD and FSE to BT300 Remote Mount SED2-BT300-DE-R SED2 208V 40hp 480V 75hp SED2-BT300-F-7 SED2 208V 50 to 60hp 480V 100 to 125hp SED2-BT300-F-8

SED2 PC Kit. Description Part No. SED2-PC-KIT Gland Plates. (included with NEMA Type 1) Frame A Frame B Frame C SED2-GL-A SED2-GL-B SED2-GL-C Protection Shield. (included with NEMA Type 1) Frame A Frame B Frame C Frame D, E SED2-PS-A SED2-PS-B SED2-PS-C SED2-PS-DE C-39 NEMA Type 1 and 3R Enclosed Reactors. Contact Sales Partners NEMA Type 3R Floor Mounting Kit. Frames A, B, C 994-809 BOP/AOP Door Mounting Kits. BOP/AOP Single Inverter SED2-DOOR-KIT1 AOP Multi-Inverter SED2-DOOR-KIT2 Operator Panel. Basic Operator Panel (included with all SED2s) Advanced Operator Panel (AOP) SED2-BOP1 SED2-AOP1

Accessories and Service Kits SED2 LON Interface Option. Description Part No. SED2-LONI/F Modbus RTU Interface Module for SED2. SED2-MODBUS2 C-40 SED2 Modbus Configuration Kit. SED2-MODBUS2_KIT