AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Similar documents
AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Output Module, IP20

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes

AS-i Safety Input Modules (M12), IP67

AS-i Safety Analog Input Module, IP20

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Analog Modules AS-i, IP67, M12

Digital Modules AS-i in IP20, 22,5 mm

Active Distributors ASi Safety, IP67

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Active Distributors AS-i Safety, Active Distributors AS-i

AS-i 3.0 motor module

Digital Modules AS-i, IP67, M12

AS-i 3.0 motor modules

AS-i 3.0 Motor modules

Analog Modules AS-i IP65, M12

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave

System manual AS-i safety monitor AC041S /00 05/2013

PCB AS-i modules, board based solutions

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

QUINT-PS/ 1AC/24DC/ 5

Phone: Fax: Web: -

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

IL CAN BK-TC-PAC. Extract from the online catalog. Order No.:

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Faults on the system Proximity switch connection technology:

CSI 6300 SIS Overview

Original operating instructions Safety relay with relay outputs G1501S / / 2016

QUINT-PS/ 1AC/24DC/20/CO

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

MSR178DP. Description. Features. Specifications

NX integrated safety System configuration. Integrated safety into machine automation

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Operating instructions. Speed monitor D / / 2014

CONFIGURABLE SAFETY RELAYS

Datasheet - CSS 11-30S-D-M-ST

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Compact Coded Magnetic Safety Interlock Switch and Control Units

The safety control of the next generation

AS-interface modules CESA

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Making Hazardous Operations Safe and Productive

Power Supply HARTING pcon

to 12a Added Standard and Electrical requirements for UL table 1.1

Rotary Measurement Technology Absolute Encoders, Multiturn

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

TwinSAFE Compact Controller

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Rotary Measuring Technology Absolute encoders, Multiturn, Profibus-DP

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

E-STOP relays, safety gate monitors

Compact Multiprotocol I/O Module for Ethernet 16 Universal Digital Channels, Configurable as PNP Inputs or 2 A Outputs TBEN-L4-16DXP

Compact multiprotocol I/O module for Ethernet 16 digital channels, configurable as 2 A PNP inputs or outputs TBEN-L1-16DXP

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Multiturn absolute encoder

QUINT-PS/24DC/48DC/ 5

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Bulletin 817 Thermistor Protection Relay

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Pluto AS-i. Safety PLC. Approvals: Control of: Features:

Power Supply HARTING pcon

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

PSR UC/ESAM4/3X1/1X2/B

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Transcription:

safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 64 release circuits up to 6 safe output circuits CAT4, SIL 3 on the Monitor safe relays or fast electronic Safe AS-i outputs are supported up to 32 independent AS-i outputs Multiple safe AS-i outputs possible via a single AS-i address 1 Safety Monitor for 2 s Operation using a single Monitor configuration! Monitor processes safety slaves on two s Coupling between the two networks superfluous Safe speed and standstill monitoring Applications up to category 4/PLe/SIL 3 Chip card for storage of configuration data AS-i Power24V capable (1) The device can be operated directly on a 24V (PELV) power supply with integrated data coupling coils and adjustable self-resetting fuses for safe use also of powerful 24V power supplies (Figure similar) (1) BWU2615, BWU2647, BWU2794, BWU2805, BWU2819, BWU3367 Figure Type Inputs Safety, SIL 3, cat. 4 PRO- FIBUS BUS BUS 3x 2 Inputs safety, expandable to max. 31 x 2-kanalig, max. 62 x 2 max. 62 x 2 Outputs Safety, SIL 3, cat. 4 6 release circuits; 6 x fast electronic 4 release circuits; 2 x relay, 2 x fast electronic 4 release circuits; 2 x relay, 2 x fast electronic Safety outputs, independent according to SIL 3, expandable to max. 31 max. 16 max. 16 Safety communication safe safe safe Number of s, number of AS-i Master (1) 1, 1 AS-i Masters 2 s, 2 AS-i Masters 2 s, 1 AS-i Master 1 power supply, 1 gateway for 2 s, inexpensive power supplies (2) Diagnostic and configuration interface (3) Article No. BWU2819 BWU2615 BWU2598 BUS max. 31 x 2 max. 16 safe (F-CPU) 1, 1 AS-i Masters RS 232 BWU2479 page 1 Mannheim, 7.4.16 We reserve the right to change any data www.bihl-wiedemann.de

safe via BUS or NET Figure Type Inputs Safety, SIL 3, cat. 4 PRO- FINET NET NET 3x 2 3x 2 Inputs safety, expandable to max. 62 x 2, 1922 in max. configuration max. 31 x 2 max. 62 x 2 Outputs Safety, SIL 3, cat. 4 6 release circuits; 6 x fast electronic 6 release circuits; 6 x fast electronic 4 release circuits; 2 x relay, 2 x fast electronic Safety outputs, independent according to SIL 3, expandable to max. 64, 1984 in max. configuration max. 31 max. 16 Safety communication safe + Safe Link safe safe Number of s, number of AS-i Master (1) 2 s, 2 AS-i Masters 1, 1 AS-i Masters 2 s, 2 AS-i Masters 1 power supply, 1 gateway for 2 s, inexpensive power supplies (2) Diagnostic and configuration interface (3) fieldbus; fieldbus; RS 232 + fieldbus Article No. BWU3367 BWU2794 BWU2647 NET max. 62 x 2 max. 16 safe 2 s, 2 AS-i Masters fieldbus; BWU2805 (1) Number of s, number of AS-i Master "Single Master": 1, 1 AS-i Master. "Double Master": 2 s, 2 AS-i Masters. "Optional AS-i Safety coupling circuit": 2 s, 1 AS-i Master. (2) 1 power supply, 1 gateway for 2 s, inexpensive power supplies "": Cost-effective power for 2 s with 1 power supply. (3) Diagnostic and configuration interface " fieldbus + diagnostic": Access to AS-i master and safety monitor via Bihl+Wiedemann proprietary software over interface or fieldbus interface. " diagnostic": Access to AS-i master and safety monitor via Bihl+Wiedemann proprietary software over interface. " fieldbus + RS 232": Access to AS-i master and safety monitor via Bihl+Wiedemann proprietary software over fieldbus interface or RS 232 interface and adapter cable. "RS 232": Access to AS-i master and safety monitor via Bihl+Wiedemann proprietary software over RS 232 interface and adapter cable. The latest version of the device description file of the gateway with integrated safety monitor is available in the "Downloads" section of the respective device. Article no. BWU2479 BWU2598 / BWU2615 Interface Fieldbus interface BUS (RS 485) Baud rates Function Card slot BWU2819 BWU2647 BWU2805 BWU2794 / BWU3367 NET (RJ-45) acc. to IEC 61158 / IEC 61784-1 2 x RJ-45,integrated 2-Port-Switch IRT capability Conformance Class B integrated switch complies with Conformance Class C (IRT capability) 9,6 KBaud... 12000 KBaud, 10/100 MBaud automatic recognition DP function: imaging of the AS-i Slaves as I/O of the BUS complete diagnosis and configuration via the DP Master chip card for storage of configuration data AS-i AS-i specification 3.0 Cycle time 150 μs * (number of slaves + 2) Operating voltage 30 V DC (20... 31,6 V) (PELV voltage) NET IO Device Media Redundancy Protocol (MRP) Shared Device www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 7.4.16 page 2

safe via BUS or NET Article no. BWU2479 BWU2598 / BWU2615 Display LCD indication of slave addresses and error messages in plain text LED NET (green / red) green: NET communication active red: no NET communication LED BUS (green) BUS communication active LED power (green) power on LED config error (red) configuration error LED U AS-i (green) AS-i voltage OK LED AS-i active (green) AS-i normal operation active LED prg enable (green) automatic addresses ming enabled LED prj mode (yellow) configuration mode active LED AUX (green) auxiliary power LEDs 1.Y1, 1.Y2, 2.Y1, 2.Y2 (EDM/Start) (yellow) state of inputs: LEDs K1... K4 (yellow) state of outputs: LEDs SI1... SI6 (yellow) state of inputs: LEDs SO1... SO6 (yellow) state of outputs: UL-specifications (UL508) External protection In general BWU2819 BWU2647 BWU2805 BWU2794 / BWU3367 state of inputs: state of outputs: state of inputs: state of outputs: An isolated source with a secondary open circuit voltage of 30 V DC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the above devices. ctüvus the devices BWU2479 BWU2598 BWU2615 BWU2647 from Bihl + Wiedemann GmbH were safety certified by TÜV Rheinland of North America, Inc. according to UL-standards and meet the safety requirements for the North American market. Applied standards EN 60529 EN 50295 EN 61000-6-2 EN 61000-6-4 EN 62061, SIL 3 EN 61508, SIL 3 EN ISO 13849-1, Performance-Level e EN ISO 13849-2 Environment Operating altitude max. 2000 m Ambient temperature 0 C +55 C Storage temperature -25 C +85 C Housing stainless steel, for DIN rail mounting Protection category IP20 Maximum tolerable shock and according EN 61131-2 vibration stress Voltage of insulation 500 V Weight 800 g Dimensions (B / H / T in mm) 75 / 120 / 96 100 / 120 / 106 109 / 120 / 96 85 / 120 / 106 109 / 120 / 106 page 3 Mannheim, 7.4.16 We reserve the right to change any data www.bihl-wiedemann.de

safe via BUS or NET Article no. BWU2479 / BWU2805 Safety monitor BWU2598 / BWU2615 / BWU2647 BWU2794 / BWU2819 / BWU3367 Start delay < 10 s Max. turn-off time < 40 s Antivalent switches for local yes inputs Standstill monitors for local inputs 6 axes up to 50 Hz (2) Speed monitors for local inputs 3 to 6 axes up to 400 Hz (3) Connection Connection COMBICON Length of connector cable I/O: max. 15 m unlimited (4) Input Inputs Safety 3 x 2 Inputs digital, EDM 4 up to 6 standard inputs Switching current statical 4 ma at 24 V, dynamic 30 ma at 24 V (T=100 μs) (1) Protection via external fuse, max. 4 A semi time-lag. (2) connection at all SI or SO terminals possible. (3) connection only at terminals SO1... SO6 configured as standard inputs (see Variations of terminal configuration for BWU2794, BWU2819, BWU3367 ) (4) loop resistance 150 Ω statical 4 ma at 24 V, dynamic 15 ma at 24 V (T=100 μs) Power supply out of AS-i out of AUX Tolerated test pulse adjustable Output Number of release circuits 4 6 on the monitor Outputs relay outputs (output circuits 1 and 2) max. contact load (1) : 3A AC-15 at 30 V, 3 A DC-13 at 30 V Power supply (semiconductor outputs) Test pulse (semiconductor outputs) semiconductor outputs (output circuits 3 and 4) max. contact load: 0,5 A DC-13 at 30 V out of AUX if output is on: minimum interval between 2 test pulses: 250 ms (as from Safety Version 4.3); maximum pulse width 1 ms semiconductor output max. contact load: 1,2 A DC-13 at 30 V, = 7,2 A in sum (5) if output is on: minimum interval between 2 test pulses: 250 ms; maximum pulse width 1 ms (5) BWU2794, BWU2819, BWU3367 Derating output current 7,2A I AUX, max [A] 5A 40 55 T amb [ C] www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 7.4.16 page 4

safe via BUS or NET Article no. Master power supply, ca. 300 ma out of AS-i circuits Operating current Master power supply, max. 300 ma out of AS-i circuit 1 (approx. 70 ma... 300 ma), max. 300 ma out of AS-i circuit 2 (approx. 70 ma... 300 ma); in sum max. 370 ma Version 1 gateway, 1 power supply, for 2 s, approx. 300 ma (PELV voltage) BWU2479 BWU2598 BWU2615 BWU2647 BWU2794 BWU2805 BWU2819 BWU3367 Redundant power supply out of AS-i: all fundamental functions of the device remain available even in case of power failure in one of the two s Safety outputs block diagram BWU2598, BWU2615, BWU2647: BWU2479 / BWU2598 BWU2615 / BWU2647 / BWU2794 / BWU2805 / BWU2819 / BWU3367 Current measurement of the AS-i circuits Self-resetting adjustable fuses AS-i earth fault monitor distinguishes between AS-i cable and sensor cable In version 1 gateway, 1 power supply for 2 AS-i circuits : only 1 gateway + 1 AS-i power supply is needed for both 2 AS-i circuits 24V 1.13 2.13 3.14 4.14 1.14 2.14 Safety outputs block diagram BWU2794, BWU2819, BWU3367 24 V SO1 0 V SO2 SO3 SO4 SO5 SO6 page 5 Mannheim, 7.4.16 We reserve the right to change any data www.bihl-wiedemann.de

safe via BUS or NET Variations of terminal configuration for BWU2794, BWU2819, BWU3367 Terminal Safe output Safe input for mechanical contacts in combination with T1, T2 Safe antivalent input Safe electronic input Standard input SI1,2 SI3,4 SI5,6 SO1,2 (1) SO3,4 (1) SO5,6 (1) (1) If outputs are configured as inputs, the input current has to be limited by an external element at 100mA Connections: Gateway + Safety Monitor: BWU2598, BW2615 BWU2647 1.13 2.Y2 + 4 24V 2.Y1 2.13 + 3 output switching elements EDM/Start inputs 1.13 2.Y2 + 4 24V 2.Y1 2.13 + 3 output switching elements EDM/Start inputs +ASI 2 + 1 1.14 1.Y1 3.14 + 2 4.14 1.Y2 2.14 EDM/Start inputs output switching elements +ASI 2 + 1 1.14 1.Y1 3.14 + 2 4.14 1.Y2 2.14 EDM/Start inputs output switching elements ASI 1 +PWR- (max. 4A) ASI +PWR- (max. 8A) BWU2479 BWU2805 24V ext. +ASI 2 ASI 1 +PWR- (max. 4A) ASI +PWR- (max. 8A) www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 7.4.16 page 6

safe via BUS or NET BWU2794 T2 T1 SI2 SI1 SI4 SI3 Safe inputs / Standard inputs SI6 SI5 Connection Description SI1, SI3, SI5 Safe input terminal (T1) SI2, SI4, SI6 Safe input terminal (T2) T1 Clock output 1 T2 Clock output 2 SO1... SO6 Safe semiconductor outputs 1... 6 24V, Power supply for local I/Os +ASI 1- Connection of AS-i circuit ASI +PWR- Power supply for Gateway and s SO5 24V SO1 SO2 Safe outputs SO3 SO6 SO4 ASI +PWR- (max. 4A) BWU2819 T2 T1 SI2 SI1 SI4 SI3 SI6 SI5 Safe inputs / Standard inputs Connection Description SI1, SI3, SI5 Safe input terminal (T1) SI2, SI4, SI6 Safe input terminal (T2) T1 Clock output 1 T2 Clock output 2 SO1... SO6 Safe semiconductor outputs 1... 6 24V, Power supply for local I/Os +ASI 1- Connection of AS-i circuit ASI +PWR- Power supply for Gateway and s SO5 24V SO1 SO2 SO3 SO6 SO4 Safe outputs ASI +PWR- (max. 4A) page 7 Mannheim, 7.4.16 We reserve the right to change any data www.bihl-wiedemann.de

safe via BUS or NET BWU3367 Connection Description T2 SI2 SI4 SI6 T1 SI1 SI3 SI5 Safe inputs / Standard inputs SI1, SI3, SI5 Safe input terminal (T1) SI2, SI4, SI6 Safe input terminal (T2) T1 Clock output 1 T2 Clock output 2 SO1... SO6 Safe semiconductor outputs 1... 6 24V, Power supply for local I/Os +ASI 1-, +ASI 2- Connection of AS-i circuits ASI +PWR- Power supply for Gateway and s +ASI 2 SO5 24V SO6 SO1 SO2 SO3 SO4 Safe outputs ASI +PWR- (max. 8A) Accessories: AS-i Power Supply 4A (art. no. BW1649) / AS-i Power Supply 8A (art. no. BW1997 Safe contact expander, 1 or 2 independent (art. no. BWU2548 / BWU2539) 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in Stainless Steel (art. no. BW2071) Software for, service and approval measurements (art. no. BW2902) For devices with BUS interface: Serial BUS Master (art. no. BW1258) BUS-DP Master simulator (art. no. BW1257) For devices with NET interface: NET Master simulator Plus (art. no. BW3057) www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 7.4.16 page 8