Energy Usage in Cloud Part2. Salih Safa BACANLI

Similar documents
Virtualization and consolidation

Power & Cooling Considerations for Virtualized Environments

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Overcoming the Challenges of Server Virtualisation

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

84 kw, Tier 3, Direct Expansion, 937 ft 2

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

MSYS 4480 AC Systems Winter 2015

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Green Computing: Datacentres

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Green Computing: Datacentres

White Paper - Infrastructure in an energy-efficient data centre

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

Warehouse-Scale Computers to Exploit Request-Level and Data-Level Parallelism

Trends and legislations in the data center industry. Pär Åberg - Business Development Manager - Swegon

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Avoiding Costs From Oversizing Datacenter Infrastructure

Distributed Pervasive Systems

DATA CENTER COLOCATION BUILD VS. BUY

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

MEASURE MONITOR UNDERSTAND

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Close Coupled Cooling for Datacentres

DC Energy, Efficiency Challenges

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Continuity Insights Chicago: Evolving Data Center Trends & Design Standards. 19 June Jose Hernandez, 30+ years of design/build experience

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

Data Center Design: Power, Cooling & Management

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

White paper adaptive IT infrastructures

Rittal Cooling Solutions A. Tropp

Energy Efficient Data Centers

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Application of TileFlow to Improve Cooling in a Data Center

Newave s approach for protecting mission critical application

Data Center Energy and Cost Saving Evaluation

SIX Trends in our World

Efficiency of Data Center cooling

Data Center Design: Power, Cooling & Management

9.6 MW, Traditional IT and OCP-compatible, Indirect Air Economizer, m 2

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Maximise Data Center Value

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

5.2 MW, Pod-based build, Chilled Water, ft 2

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

EP s approach to Power & Energy efficiency in DCs & paradigms

Lecture 20: WSC, Datacenters. Topics: warehouse-scale computing and datacenters (Sections )

IT Air Conditioning Units

> Executive summary. Virtualization: Optimized Power and Cooling to Maximize Benefits. White Paper 118 Revision 2. Contents.

How to Increase Data Center Efficiency

PowerWAVE 9000DPA Designed to meet the requirements of today and tomorrow

Data Center Trends and Challenges

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

Data Center Infrastructure Management (D.C.I.M.)

Industry leading low energy evaporative fresh air cooling.

Next Generation Cooling

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Cooling Solutions & Considerations for High Performance Computers

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

LCS Value Proposition November 2014

Cloud environment. dr inż. Piotr Boryło , Kraków

Commercialization of the Cloud Platform Suite and Endeavors toward a High-Efficiency Server

ABB Automation & Power World: April 18-21, 2011 CLP CEU Myth Busting: The Truth behind Data Center Marketing Trends

PowerWave 9000DPA Designed to meet the requirements of today and tomorrow

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

How to improve efficiency in Data Processing Centres (DPCs) The importance of knowing the PUE. center DPC

Data Center Fundamentals: The Datacenter as a Computer

HPC Solutions in High Density Data Centers

Thermal management. Thermal management

APC APPLICATION NOTE #74

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

Green Cloud: Emerging trends and their Impacts

Reducing Data Center Cooling Costs through Airflow Containment

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime

Liebert DCW CATALOGUE

Charles Nolan. Do more with less with your data centre A customer s perspective. Director IT Infrastructure, UNSW. Brought to you by:

The Evolving Data Center

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Energy Efficiency and WCT Innovations

IBM eserver Total Storage, On Demand

The End of Redundancy. Alan Wood Sun Microsystems May 8, 2009

ΕΠΛ372 Παράλληλη Επεξεργάσια

1008 kw, Tier 2, Chilled Water, ft 2

Delivering Next Generation DCIM for a Mobile Workforce

Data center redundancy. Air traffic High-speed pipes. Training Design. Costs. Guy with a wrench. Terrorism

Transcription:

Energy Usage in Cloud Part2 Salih Safa BACANLI

Cooling Virtualization Energy Proportional System Conclusion

Cooling After servers, the second largest consumer of power in a data center is the cooling system.(kava, 2012) This cloud-computing hardware must be cooled by something, regardless of the hardware s location or owner. Required cooling infrastructure depends on the computing resources power density and layout.(infotech,2011)

Air cooling is popular, inexpensive,simple to scale to fit room needs. Fine for systems up to 15 KW You need to move the air through the equipment (air s heat transfer coefficient is nearly constant). Ventilation air and natural winds OR You need to cool the air in the cloud room.

Raised Floor The equipments (racks) are put on a platform higher than the ground. The area is used for air space or water cooling pipes.

For systems who energy consumption is bigger than 15 KW/rack you need to use liquid. Moving large volumes of air can be very expensive for very-high-density racks. Mineral oil and water can be used for liquid.

Virtualization as solution? Virtualization is nice if used properly. Having many computers in the same hardware. Scaling: Horizontal: Increasing VM Vertical:increase resource allocation of current VMs (increase their CPU share) (Paya & Marinescu, 2013)

Disadvantageous Virtualization 1) The rise of high density Higher power density is likely to result from virtualization, at least in some racks. Areas of high density can pose cooling challenges that, if left unaddressed, could threaten the reliability of the overall data center. 2) Reduced IT load can affect PUE After virtualization, the data center s power usage effectiveness (PUE) is likely to worsen. This is despite the fact that the initial physical server consolidation results in lower overall energy use. If the power and cooling infrastructure is not right-sized to the new lower overall load, physical infrastructure efficiency measured as PUE will degrade.

3) Dynamic IT loads Virtualized IT loads, particularly in a highly virtualized, cloud data center, can vary in both time AND location. In order to ensure availability in such a system, it s critical that rack-level power and cooling health be considered before changes are made. 4)Lower redundancy requirements are possible A highly virtualized data center designed and operated with a high level of IT fault-tolerance may reduce the necessity for redundancy in the physical infrastructure. This effect could have a significantly positive impact on data center planning and capital costs.

To improve post-virtualization PUE, the data center s infrastructure efficiency curve must be improved (lowered) by optimizing power and cooling systems to reduce the waste of oversizing and better align capacity with the new, lower load. In addition to improving efficiency, optimized power and cooling will directly impact the electric bill by reducing the power consumed by unused power and cooling capacity.

Energy proportional system Normal System

For normal server Utilization is measure of application perfomance like requests per second on a web server

Energy efficiency of servers have increased as the time passed.

For Energy Proportional Server

Conclusion The introduction of more efficient CPUs based on chip multiprocessing has also contributed positively toward more energy-efficient servers. However, long-term technology trends invariably indicate that higher performance means increased energy usage. As a result, energy efficiency must improve as fast as computing performance to avoid a significant growth in computers energy footprint. (Barroso & Hölzle, 2007)

To a first-order approximation, both cooling and provisioning costs are proportional to the average energy that servers consume, therefore energy efficiency improvements should benefit all energy dependent components

References N.A (2011).Cooling the Cloud,Infotech. [ONLINE] Retrived from http://it.tmcnet.com/topics/it/articles/216010-cooling-cloud.htm [24.10.2013] Kava,J. (2012). Cooling the cloud: A look inside Google s Hot Huts.Google Green Blog[ONLINE]Retrieved from http://googlegreenblog.blogspot.com/2012/10/coolingcloud-look-inside-googles-hot.html [24.10.2013] Barroso,L.A. & Hölzle,U. (2007). The case for energy proportional computing.computer,december 2007,33-37. Schneider Electricity-Data Center Science [ONLINE] Retrieved from http://www.facilitiesnet.com/microsite/energy-efficient-data-centerstrategies/pdf/whitepaper118.pdf [24.10.2013] Paya, A. & Marinescu, D.C.(2013). Energy-aware Application Scaling on a Cloud.Arxiv.org[ONLINE] Retrieved from http://arxiv.org/abs/1307.3306 [24.10.2013]