Industrial Power Supplies

Similar documents
Industrial Power Supplies

Industrial Power Supplies

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable)

Universal Power Supplies

Enclosed Power Supplies

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

Industrial Power Supplies

Industrial Power Supplies

Industrial Power Supplies

Switching Power Supplies

TEP 100WIR Series, 100 Watt

VP ELECTRONIQUE MASSY - Tel

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

TEP 75WI Series, 75 Watt

Output Amps Model Number Output Voltage (max), (Note 2) Load Reg (max) Ripple & Noise pk-pk Efficiency typ.

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

C B. Models. Operating up to 5000m altitude 5 year product warranty

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

Packaging (5) Protection (3) Isolation Voltage (4)

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Output Current Input Current Max. capacitive Load

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Rhino PSM Power Supplies. Operating Instructions

IEC/EN/UL60950 & CE certified, EN55032 Class B

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Universal input VAC <150mW No load power consumption

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

20A DRR Module / 40A DRR Module

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Constant Voltage Mode

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Simple but elegant look and ease of installation make it ideal for various industrial applications.

DC/DC Converters. TSM Series, 1 Watt. Features. Models

Safety Standards. Model Number:

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

Vin= 24VDC Vout= full load with normal start-up time, no external components with <1 second start-up time + diode protection circuit

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

DeltaV Bulk Power Supplies

SITOP 3-phase 24 V DC, 20 to 40 A

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

FMP VDC RECTIFIER 42 Amps 2000 Watts

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

R0.5S_D ECONOLINE. Features. 0.5 Watt SMD Isolated Single or Dual Output. Derating-Graph (Ambient Temperature) DC/DC-Converter with 3 year Warranty

Safety Standards. Model Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Safety Standards. Model Number:

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Protection (3) alternative Pinning Option (4) Single or Dual

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Safety Standards. Model Number:

MMA-30 series 30W Medical Grade Ultraminiature Switching Power Supplies. Single / Dual / Triple Outputs

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

RM- S/_ Protection (3) Isolation Option (4) Single

DeltaV Bulk Power Supplies

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Datasheet. ACF-10 Series AC/DC Power Module 10W

MMA-15 series. 15W Medical Grade Ultraminiature Switching Power Supplies. Single / Dual / Triple Outputs. Universal 90 to 264VAC Input

ORDERING INFORMATION SEE PAGE 6

Safety Standards. Model Number:

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Safety Standards. Model Number:

Safety Standards. Model Number: Unit Weight:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

STEP-PS/1AC/24DC/1.75

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

Safety Standards. Model Number:

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

Transcription:

, Features For industrial, office and residential applications Ultracompact plastic housing Connection by spring clamp terminals or detachable screw terminal block Reliable snap-on mounting on DIN-rails Adaptor for wall mounting Universal input 85 264 VAC, 50/60 Hz Models with 5, 12, 24 & 48 VDC output able Power OK signal Low ripple and noise Overload and short-circuit protection Parallel operation possible Worldwide safety approvals Redundancy module 3-year product warranty UL 60950 UL 508C UL 60950-1 The TRACOPOWER TCL series is a family of DIN-rail power supplies with an excellent price/performance ratio. With tightly regulated output voltage and high immunity against electrical disturbances on the mains they provide a reliable power source for sensitive loads in industrial process controls, machine tools and other equipment exposed to a difficult industrial environment. Compact size, light weight, easy snap-on mounting on DIN-rails and the choice of two connection terminal versions are other features of these power supplies. The TCL series complies with all major safety standards for Europe (EN60950-1, EN50178), North America (UL/ cul 60950, UL 508C listed) or elsewhere in the world (CB-Report). Models Order Code Voltage Power * Voltage Current Connection Ranges max. nom. max. TCL 024 105 5.1 VDC 4.0 A TCL 024 112 24 W 12 VDC 2.0 A TCL 024 124 85 264 VAC 24 VDC 1.0 A TCL 060 112 Universal 12 VDC 4.0 A TCL 060 124 50/60 Hz 60 W 24 VDC 2.5 A Detachable screw TCL 060 148 85 375 VDC 48 VDC 1.25 A terminal blocks TCL 120 112 120 W 12 VDC 8.0 A TCL 120 124 24 VDC 5.0 A TCL 240 124 85 132/187 264 VAC 240 W 24 VDC 10.0 A TCL 024 124C 24 W 24 VDC 1.0 A TCL 060 112C 85 264 VAC 12 VDC 4.0 A TCL 060 124C Universal 60 W 24 VDC 2.5 A TCL 060 148C 50/60 Hz 48 VDC 1.25 A Spring clamp TCL 120 112C 85 375 VDC 12 VDC 8.0 A terminals 120 W TCL 120 124C 24 VDC 5.0 A * able http://www.tracopower.com Page 1 of 6

Specifications voltage range Industrial Power Supplies 85 264 VAC/85 375 VDC TCL 240 model: 85 132/187 264 VAC autoselect (no DC input) derating at operation between 85...93 VAC/85...130 VDC 15% for TCL 060 & TCL 120 20% for TCL 024-112 & TCL 024-124 & TCL 240 30% for TCL 024-105 frequency Harmonic limits current at full load (typ.) (115 VAC / 230 VAC) Recommended circuit breaker (characteristic C or slow blow fuse) Specifications 47 63 Hz EN 61000-3-2, Class A TCL 024 models: 0.35 A / 0.2 A TCL 060 models: 1.2 A / 0.6 A TCL 120 models: 2.0 A / 1.0 A TCL 240 model: 3.3 A / 1.7 A able range 5.1 VDC model: 5.0 5.25 VDC (potentiometer on frontpanel) 12 VDC models: 12 15 VDC (12-16 VDC for TCL 024-112) 24 VDC models: 24 28 VDC 48 VDC models: 48 56 VDC 5.0 A regulation (10 to 90% load variation) 2.5 % (1 % for TCL 60-112) Ripple and noise (20MHz bandwidth) Electronic short circuit protection Parallel operation Overvoltage protection, trigger point Hold-up time (115 VAC / 230 VAC) <50 mv pk-pk 5.1 VDC model: <6.5 VDC 12/24 VDC models: <40 VDC 48 VDC models: <60 VDC current limitation at 120 % typ. (constant current, automatic recovery TCL 24 models: foldback, automatic recovery) output current characteristic suitable for parallel operation of max. 5 units (not for TCL 240-124) min. 15 ms / min. 125 ms TCL 240 model: min. 15 ms / min. 40 ms Power OK signal (TCL 60 & TCL 120 only) trigger output signal point (reference to Vout) 12 VDC models: >11V 11.0 V ±1.0 V / 60 ma max. 24 VDC models: >22V 22.0 V ±2.0 V / 30 ma max. 48 VDC models: >44V 44.0 V ±4.0 V / 15 ma max. General Specifications Temperature ranges Operating 10 C to +70 C max. Storage (non operating) 25 C to +85 C Temperature derating at 187...264 VAC or 265...375 VDC operation 1.7 %/K above 50 C at 93...132 VAC or 130...187 VDC operation 1.1 %/K above 40 C at 85...130 VDC operation 1.3 %/K above 30 C Humidity (non condensing) Temperature coefficient Switching frequency Efficiency 95 % rel. H max. 0.02 %/K 55 180 khz depending on load (frequency modulation) 88 % typ. http://www.tracopower.com Page 2 of 6

General Specifications Reliability, calculated MTBF at +25 C (according to IEC-1709) TCL 024 models: >2.68 Mio h TCL 060 models: >2.94 Mio h TCL 120 models: >1.62 Mio h (TCL 240 tbd.) Safety standards Information technology equipment IEC 60950-1, EN 60950-1 (output SELV), UL Std. 60950-1 (2nd Edition) +Am1:2011, CAN/CSA-C22.2 No. 60950-1-07 +Am1:2011 Industrial control equipment UL 508 Electronic equipment for power installation EN 50178 Electrical equipment for machines EN 60204 Safety transformers for SMPS EN 61558-2-16 Limited power source NEC Class 2 (TCL 60 models only) Safety approvals CB test certificate (IEC 60950-1) www.tracopower.com/products/tcl-cb.pdf UL approval UL 508C listed, CSA C22.2 No. 14 File e210002 www.ul.com -> certifications UL approval UL 60950, File e181381 (except TCL 240) www.ul.com -> certifications CSA certification UL 60950-1, CSA 60950-1-03 www.tracopower.com/products/tcl-csa.pdf BG certificate (by SIQ) www.tracopower.com/products/tcl-bg.pdf Environmental compliance Reach www.tracopower.com/products/tcl-reach.pdf RoHS RoHS directive 2011/65/EU Electromagnetic compatibility (EMC), emissions EN 61000-6-3 Electromagnetic compatibility (EMC), immunity EN 61000-6-2 Voltage sag inmmunity www.tracopower.com/products/tcl-semif47.pdf Safety class degree of protection class 1 Case protection IP 20 (IEC 60529) Enclosure material Mounting Options Installation instructions Industrial Power Supplies plastic 94V-0 rated DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) Adapter for wall-/chassis mounting (included) output characteristic optimized for battery charging available on request www.tracopower.com/products/tcl-inst.pdf All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. http://www.tracopower.com Page 3 of 6

TCL REM240 Redundancy Module This module enables redundant operation of any two TCL models by decoupling the 2 power supplies. It can also be used to separate sensitive loads from the main power source. Order Code Nominal Voltage Max Power Voltage Current Voltage Range per max. TCL REM240 5...48 VDC 5...60 VDC 200 W Vin 0.9 VDC 8 A Specifications Operating temperature 10 C to +70 C max. (14 F... +158 F) derating above +40 C (104 F): 1.5 %/K Electromagnetic compatibility in correspondence to connected units (no internal switching device) Dimensions same as model TCL 024 (see page 4) Connection Installation instructions detachable screw terminal block www.tracopower.com/products/tcl-rem-inst.pdf Case Dimensions TCL 024 and TCL-REM240 models 1 2 100.0 (3.94) 75.0 (2.95) 2 Vout 2 Neutral 3 Live 27 (1.06) 2.2 (0.09) Weight: 140 g (4.9 oz) Dimensions in [mm], ( ) = Inch Tolerances: ±0.5 mm (±0.02) http://www.tracopower.com Page 4 of 6

Case Dimensions TCL 60 models 4 5 100.0 (3.94) 75.0 (2.95) 2 +Vout 2 Neutral 3 Vout 3 Live 4 Vout 5 Power OK 3.2 (0.13) Weight: 265 g (9.4 oz) 45 (1.77) TCL 120 models 4 5 100.0 (3.94) 75.0 (2.95) DIN rail mounting hooks 20mm (0.79) wide 3.2 (0.13) 2 +Vout 2 Neutral 3 Vout 3 Live 4 Vout 5 Power OK 85 (3.35) Weight: 440 g (15.5 oz) Dimensions in [mm], ( ) = Inch Tolerances: ±0.5 mm (±0.02) http://www.tracopower.com Page 5 of 6

Case Dimensions TCL 240 model 4 5 125 (4.92) 110 (4.33) 2 +Vout 2 Neutral 3 Vout 3 Live 4 Vout 5 Power OK Weight: 950 g (33.5 oz) 85 (3.35) Wall Mounting Bracket Instead on a DIN-rail, the modules can be also mounted on a chassis or wall with help of a mounting bracket which is supplied as standard with each power supply Dimensions in [mm], ( ) = Inch Tolerances: ±0.5 mm (±0.02) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com Rev. May 16. 2014 Page 6 of 6