FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

Similar documents
FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I

SIRCO Load break switches for power distribution from 125 to 5000 A

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

FUSERBLOC and high speed fuses (ur) Fuse combination switches protection of power semi-conductors up to 1250 A

Contents. Volume 5 Motor Control and Protection CA E December

References. References. Rating (A) Référence

Complete UL/CSA Disconnect Switch Kits

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Non-Fusible Disconnect Switches

Non-Fusible Disconnect Switches

FUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

References. For SIRCO MV. References

UL 98 Fusible Disconnect Switches

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

Catalog Number A, up to two ACs max (F-, G-Frame) Number of Poles. Rating (Frame) (D-Frame) 400 (E-Frame)

The safest way to switch power on and off in your industrial control panels.

FUSERBLOC from 30 to 800 A

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Disconnect Switches. Safe Switching and Disconnecting

194E FA 32 E P11 P11 6

Manual Motor Control Switches and Disconnects

60103 Circuit Breaker

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Circuit Breakers Type CTI 25M, CTI 45MB

Motor protection relays

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Magnetically Actuated Safety Interlock Switches

SWITCH DISCONNECTORS 11

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Mini Contactors & Overloads

DISCONNECT SWITCHES > QUICK REFERENCE GUIDE north american edition

MOTOR PROTECTION CIRCUIT BREAKERS

CS8 Industrial Control Relays

Allen-Bradley 1492-RCDA4A40

the Santon FCS-type switch Disconnect Superior Switch Solutions

194E FA 32 E P11 P11 6

Magnetically Actuated Safety Interlock Switches

RiLine Compact The smart power distribution system

Motor protection circuit breakers

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

MOTOR & CIRCUIT PROTECTION

Protection Equipment

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

TeSys IEC Contactors and Overload Relays

Compact Coded Magnetic Safety Interlock Switch and Control Units

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

UL 489 DIN Rail Miniature Circuit Breakers

Section 4 Ground-Fault Protection Devices

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

UL 489 DIN Rail Miniature Circuit Breakers

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Switch rated plugs and receptacles with NEMA 4X protection

CS7 Industrial Control Relays

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Large Frame IEC Contactors

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

920 Remote Control (RC) Switches

Miniature Circuit Breakers and Supplementary Protectors. Contents

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Safety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2

Introduction Circuit Protection

Switch Disconnectors, Main and EMERGENCY-STOP Switches

1492-SP Supplementary Protectors

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Micro Contactor MA Series

Performance. Standards. Technical data

8.2 R5 Series (UL 508) Non-Fusible 16 80A. 8.4 MTS Manual Transfer/Double Throw Switches

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Allen-Bradley Bulletin 100 Contactors

22mm Non Illuminated Metal Operators

Go to:

SECTION DISCONNECT SWITCHES

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

3RV1 Circuit-Breakers

WMS SUPPLEMENTARY PROTECTORS

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

CONTROL PANEL WIRING SPECIFICATIONS

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

ALLEN BRADLEY RELAY Bulletin 700-HF

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

Manual Motor Protectors

Transcription:

Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches are heavy duty switches that break and make power circuits on and off load. The switches employ double break contacts per pole that ensure complete isolation of the fuse when the switch is in the OFF position. These switches are extremely durable and are tested and approved for use in the most demanding applications. The TEST position function is enabled with handles with the TEST position. This function tests the control circuit auxiliaries without switching the main contacts. It is a simple alternative to a separately wired push button. fuser-ul_005_a > Improved safety > High breaking capacity > A complet range of functions Conformity to standards (1) > IEC 60947-3 > NFPA79 (02 Edition) > UL489, Guide WAZ, file E255272 (Frame size 1 and 2) > UL98, Guide WHTY, file E1138 (Frame sizes 3 to 8) > CSA22.2 #5, Class 4652-06, file 112964 (Frame size 1 and 2) > CSA22.2 #4, Class 4651-02, file 112964 (Frame sizes 3 to 8) (1) Product reference on request. Advantages Improved safety On load make and break power circuit applications. Double break by phase. Touch safe covers. High breaking capacity. Up to 0 ka Short circuit rating. A complet range of functions Compact footprints. Front or side operation. Flange operation. NFPA 79 compliant kits. Voltage sensing terminals. 284 General Catalogue 17-18

References Fusible disconnect Rating (A) Fuses Frame size No. of poles Switch body Direct handle Front external handle External right side handle (1) Shaft external handle NFPA79 kit U-type auxiliary contacts Terminal shrouds CD 30 A CC 1 CD 30 A 2 3 P 3710 3003 3 P + switched neutral 3 P + solid neutral 3710 4003 3710 5003 3 P 3710 3004 3 P + switched neutral 3 P + solid neutral 3710 4004 3710 5004 2 P 3861 04 3729 4012 3729 40 S0 type IP65 1, 3R, 12 93 0111 9D 0111 S1 type IP65 1, 3R, 12 1F 2111 1D 2111 S0 type 0 mm 7.9 inches 05 06 3 mm 12.6 inches 05 0632 400 mm 15.7 inches 05 0640 S1 type 0 mm 7.9 inches 01 05 3 mm 12.6 inches 01 0532 400 mm 15.7 inches 01 0540 3729 4532 1 contact NO 3999 0701 1 contact NC 3999 0702 not required 30 A 4 60 A 4 3 P 3861 3004 4 P 3861 6004 2 P 3861 05 3 P 3861 3005 3629 7910 S1 type 1, 3R, 12 Defeatable 1F 2111 Defeatable 1D 2111 - Test Defeatable 1D 2115 S1 type 1H 6111 S1 type Red / yellow 1I 6111 S1 type 0 mm 7.9 inches 00 10 3 mm 12.6 inches 00 1032 3729 7540 4 P 3861 6005 (1) No door interlocking. General Catalogue 17-18 285

References (continued) Rating (A) fuses Frame size No. of poles Switch body Direct handle Front external handles External right side handle (1) Shaft for external handle NFPA79 kit U-type auxiliary contacts Terminal shrouds 60 A 5 100 A 5 0 A 6 400 A 7 2 P 3861 06 3 P 3861 3006 4 P 3861 6006 2 P 3861 10 3 P 3861 3010 S2 type S2 type 0 mm 4 P 3861 6010 1, 3R, 12 7.9 inches Defeatable 2H 6111 00 10 3629 7910 2 P 3861 2F 2111 3898 Red / yellow 3 mm 12.6 inches 3 P 3861 30 Defeatable 00 1032 3898 30 2D 2111 2I 6111 1 contact type 4 P 3861 60 NO 3898 40 2 P 3851 38 S2 type 3729 7540 3999 0701 1 contact type NC 3999 0702 not required 3898 40 3 P 3851 3038 3729 7544 3898 3040 4 P 3851 6038 3898 6040 600 A 8 800 A L 8 2 P 3850 60 3 P 3850 3060 4 P 3850 6060 2 P 3850 80 3 P 3850 3080 4 P 3850 6080 3859 6011 S3 type 1, 3R, 12 Defeatable 3F 3111 Defeatable 3D 3111 S3 type 0 mm 7.9 inches 00 12 3 mm 12.6 inches 00 1232 3729 7552 2 P 3898 80 3 P 3898 3080 4 P 3898 4080 (1) No door interlocking. Accessories Electronic fuse operation indication (FMD) For fuse cartridge BS88, DIN and UL. References For FUSERBLOC 100 to 800 A Nb of leds Type Operating voltage Ph/Ph Reference 1 FMD10 1-260 VAC 3899 11 1 FMD10 380-690 VAC 3899 1380 3 FMD30 1-260 VAC 3899 31 3 FMD30 380-690 VAC 3899 3380 Accessories Reference Kit for connection accessories Standard 3819 91 Kit for connection accessories Door mounted 3829 91 Principle The FMD detects fuse operation using a bistable relay and a signaling LED. It can be mounted on a DIN rail, a back plate, next to the FUSERBLOC, or on the door. acces_319_a acces_310_a Relay characteristics Relay operating current I c (A) Type AC-15 DC-13 FMD10 and FMD30 2.5 A 0.2 FMD10 1-led version FMD30 3-leds version 286 General Catalogue 17-18

NFPA79 accessories Flange handle for flange operation Meets both UL508A and NFPA79 requirements. The handle will operate the switch by cable or rod. Rating (A) Type Nema type Reference 30 0 Standard handle 1, 3, 3R, 4, 12 3729 9002 (1) 30 0 Chrome plated handle 1, 3, 3R,, 12 3729 9003 (1) (1) Defeatable handle. sirco_246_a_1_cat Cable operator Link between the flange handle and the switch, please order the flange handle, the mechanism and a cable length of your choice. Rating (A) Description Reference 30 0 Cable flange mechanism 3729 9903 Cable length (inches) Cable length (mm) Reference 36 900 3729 9992 60 1500 3729 9993 1 3000 3729 9994 ul_042_b_1 sirco_247_a_1_cat Rod operator Link between the flange handle and the switch. The rod flange is an economical solution, please order the flange handle and a rod kit. Rating 30 0 A For enclosure depth (inches) For enclosure depth (mm) Reference 8 24 3 613 3729 9904 ul_043_a NFPA79 "Through the door" kit Meets both UL508A and NFPA79 requirements. Allows retrofitt of your installations for ratings. Please order an S-type external handle separately. Number of auxiliary contact installed on the switch will be limited to 1 layer (instead of 2). If more needed please use the S type auxiliary contacts ul_121_b Rating (A) Frame size Reference CD 30 1/2 3729 4532 30 0 3 6 3729 7540 400 7 3729 7544 600 800 8 3729 7552 General Catalogue 17-18 287

Accessories Direct handle Rating (A) Color Fuses Fig. Reference CD 30 CC 1 3729 4012 CD 30 1 3729 40 30 400 2 3629 7910 600 800 / L 2 3859 6011 Fig.1 acces_7_a_2_cat acces_261_a Fig. 2 External handle The locking function of the front external handle prevents the user from opening the door of the enclosure when the switch is in the "ON" position, and when the switch is padlocked in the OFF position (S1, S2, S3 and S4 type handles only). Front operation Opening the door when the switch is in the "ON" position is possible by defeating the interlocking function with the use of a tool (authorised persons only). The interlocking function is restored when the door is re-closed. Handle Standard Heavy duty Rating (A) Frame size type Nema type Test Handle color Reference Reference CD 30 1 S0 1, 3R, 12 93 0111 CD 30 1 S0 1, 3R, 12 Red/Yellow 94 0111 CD 30 1 S0 9D 0111 CD 30 1 S0 Red/Yellow 9E 0111 CD 30 60 3/4 S1 1, 3R, 12 1F 2111 CD 30 60 3/4 S1 1, 3R, 12 Red/Yellow 1G 2111 CD 30 60 3/4 S1 1D 2111 1D 2911 CD 30 60 3/4 S1 Red/Yellow 1E 2111 1E 2911 CD 30 60 3/4 S1 - Test 1D 2115 CD 30 60 3/4 S1 - Test Red/Yellow 1E 2115 60 0 (1) 5 7 S2 - Test 2D 2115 60 0 (1) 5 7 S2 - Test Red/Yellow 2E 2115 60 400 5 7 S2 1, 3R, 12 2F 2111 60 400 5 7 S2 1, 3R, 12 Red/Yellow 2G 2111 60 400 5 7 S2 2D 2111 2D 2911 60 400 5 7 S2 Red/Yellow 2E 2111 2E 2911 600 800 8 S3 1, 3R, 12 3F 3111 600 800 8 S3 1, 3R, 12 Red/Yellow 3G 3111 600 800 8 S3 3D 3111 3D 3911 600 800 8 S3 Red/Yellow 3E 3111 3E 3911 S0-type handle S- type handle S2-type handle acces_263_a_2_cat acces_9_a_2_cat acces_164_a_2_cat (1) No test position on 400 A. Right side operation Frame Handle Standard Heavy duty Rating (A) size type Nema type Test Handle color Reference Reference 30 60 3/4 S1 1H 6111 1H 6911 30 60 3/4 S1 Red/Yellow 1I 6111 1I 6911 100 400 5 7 S2 2H 6111 2H 6911 100 400 5 7 S2 Red/Yellow 2I 6111 2I 6911 600 800 8 S3 consult us consult us 600 800 8 S3 Red/Yellow consult us consult us S3-type handle acces_151_a_1_cat 288 General Catalogue 17-18

S-type handle raiser Enables S-type handles to be fitted in place of existing older style SOCOMEC handles. Adapter can also be used as a spacer to increase the distance between the panel door and the handle lever. Dimensions Increases distance to door by 0.47 in / 12 mm. Handle color Pack qty External degree of protection (IP) Reference 10 IP65 93 0000 acces_187_a_1_cat Alternative color S-type handle cover For single lever handle S-type S1, S2, S3 and double lever handle, type S4. Other colors: please consult us. Handle color Pack qty Handle type Reference Light grey 50 S2, S3 01 0001 Dark grey 50 S2, S3 01 0011 Light grey 50 S4 01 0031 Dark grey 50 S4 01 0041 acces_198_a_1_cat Shaft for external handle Standard lengths: - 7.9 in / 0 mm, - 12.6 in / 3 mm, - 15.7 in / 400 mm. Other lengths: please consult us. Dimensions X Length Rating (A) (in) (mm) Handle type (in) (mm) Reference CD 30 4.02 9.65 102 245 S0 7.9 0 05 06 CD 30 4.02.37 102 365 S0 12.6 3 05 0632 CD 30 4.02 17.52 102 445 S0 15.7 400 05 0640 CD 30 4.02 9.65 102 245 S1 7.9 0 01 05 CD 30 4.02.37 102 365 S1 12.6 3 01 0532 CD 30 4.02 17.52 102 445 S1 15.7 400 01 0540 30 100 5.3 9.06 135 230 S2 7.9 0 00 10 30 100 5.3 13.78 135 350 S2 12.6 3 00 1032 30 100 5.3 16.93 135 430 S2 15.7 400 00 1040 30 100 5.3.87 135 530 S2 19.7 500 00 1050 0 5.7 9.06 5 230 S2 7.9 0 00 10 0 5.7 13.78 5 350 S2 12.6 3 00 1032 0 5.7 16.93 5 430 S2 15.7 400 00 1040 0 5.7.87 5 530 S2 19.7 500 00 1050 400 7.87 10.24 0 260 S2 7.9 0 00 10 400 7.87 22 0 560 S2 19.7 500 00 1050 400 7.87.96 0 380 S2 12.6 3 00 1032 400 7.87 18.1 0 460 S2 15.7 400 00 1040 600 800 10.63 11.97 270 304 S3 7.9 0 00 12 600 800 10.63 16.69 270 424 S3 12.6 3 00 1232 600 800 10.63 19.84 270 504 S3 15.7 400 00 1240 600 800 10.63 23.78 270 604 S3 19.7 500 00 1250 X acces_2_a_1_cat acces_369_a_1_cat acces_5_b_1_cat General Catalogue 17-18 289

Accessories (continued) Shaft guide for external handle This accessory enables handle to engage shaft with a misalignment of up to 15 mm. Required for a shaft length over 400 mm for S1 to S3 handles and for a shaft from 12.6 in / 3 mm for S0 handle. Description Reference Shaft guide for S1 to S3 handles 29 0000 Shaft guide for S0 handle 19 0000 acces_260_a_2_cat U-type auxiliary contacts U-type AC can be configured to be operated on both, standard and TEST position switches from CD 30 to 800 A. Each slot can accommodate up to 2 interlocked ACs. - For CD 30A/CC, a maximum of 4 ACs (8 with an additional holder): - For CD 30A/, maximum 2 ACs (6 with an additional holder), - For 30 to 0A/, maximum 4 ACs, - For 400 to 800A/L, maximum 8 ACs. Electrical characteristics A600. When FUSERBLOC is front operated, ACs are prebreak and signaling position I and 0. When FUSERBLOC is side operated, Acs are signaling positions I and 0. acces_056_a_1_cat A B S-type auxiliary contacts Side operated auxiliary contacts for FUSERBLOC 30 to 400 A, position OFF and ON signalled by 1 to 4 NO + NC auxiliary contacts. Electrical characteristics A600/D600. S-type auxiliary contacts are signaling position I and 0. NO+NC auxiliary contacts Rating (A) Number of contacts Reference 30 800 1 3999 U041 30 800 2 3999 U042 acces_083_a_1_cat NO auxiliary contacts Rating (A) Number of contacts Reference CD 30 800 1 3999 0701 NC auxiliary contacts Rating (A) Number of contacts Reference CD 30 800 1 3999 0702 Contact holder for additional auxiliary contacts Rating (A) Fuses Reference CD 30 CC 3999 0710 CD 30 3999 0710 CD 30 : U-type auxiliary contacts cannot be mounted on switches with direct operation handle acces_043_a_1_x_cat acces_051_a_1_cat 290 General Catalogue 17-18

Terminal shrouds Top or bottom protection against direct contact with terminals or connection parts. 2 sets required to fully shroud both line and load terminals. Front and side operation Rating (A) No. of poles Reference (1) 30 100 2/3/4 P as standard 0 2 P 3898 0 3 P 3898 30 0 4 P 3898 40 400 2 P 3898 40 400 3 P 3898 3040 400 4 P 3898 6040 600 800 2 P 3898 80 (2) 600 800 3 P 3898 3080 (2) 600 800 4 P 3898 4080 (2) (1) Top or bottom. (2) Line side delivered as standard. fuser_3_a_1_cat Terminals lugs Connection of cables to the terminals. Rating (A) Wires range No wires per lug Lugs per kit Wires Reference CD 30 # - #10 1 Cu as standard 30 # - #10 1 Cu as standard 30 60 #10 - #6 1 Cu as standard 60 100 #12 - #1 1 Cu as standard 0 #6-300MCM 1 2 Cu / Al 3954 0 #6-300MCM 1 3 Cu / Al 3954 30 0 #6-300MCM 1 4 Cu / Al 3954 40 400 #2-600MCM 1 2 Cu / Al 3954 40 400 #2-600MCM 1 3 Cu / Al 3954 3040 400 #2-600MCM 1 4 Cu / Al 3954 4040 400 2 x (#6-350 MCM) 2 2 Cu / Al 3954 41 400 2 x (#6-350 MCM) 2 3 Cu / Al 3954 3041 400 2 x (#6-350 MCM) 2 4 Cu / Al 3954 4041 600 800 2 x (#2-600MCM) 1 2 Cu / Al 3954 60 600 800 2 x (#2-600MCM) 2 3 Cu / Al 3954 3060 600 800 2 x (#2-600MCM) 2 4 Cu / Al 3954 4060 ul_032_a Solid links Rating (A) Fuses No of links per kit Reference 100 3 3799 9010 100 4 3799 8010 0 3 3799 90 0 4 3799 80 400 3 3799 9040 400 4 3799 8040 600 800 / L 3 3799 9080 600 800 / L 4 3799 8080 fuser-ul_019_a_1_cat Class T fuse adapter The adapter makes it possible to fit class T fuses in the FUSERBLOC fuse switches. Size Class T fuse Rating (A) (in) (mm) No. of poles Reference 100 2.34 59.5 3 P 3729 8010 0 2.48 63 3 P 3729 80 400 2.71 69 3 P 3729 8040 600 2.95 75 3 P 3729 8060 800 3.17 80.5 3 P 3729 8080 100 2.34 59.5 4 P 3729 9010 0 2.48 63 4 P 3729 90 400 2.71 69 4 P 3729 9040 600 2.95 75 4 P 3729 9060 800 3.17 80.5 4 P 3729 9080 fuser-ul_0_b_1_cat General Catalogue 17-18 291

Characteristics according to UL98/CSA22.2 #4 CD 30 to 800 A Characteristics UL and CSA CD 30A (3) CD 30A (3) 30A 60A 60A 100A 0A 400A 600A 800A Short circuit rating at 600 VAC (ka) 100 100 0 100 0 0 0 0 0 0 Type of fuse CC L Max. fuse rating (A) 30 30 30 60 60 100 0 400 600 800 Max. motor hp / FLA 3 ph motor max. 2-240 VAC 7.5 / 22 7.5 / 22 7.5 / 22 15 / 42 15 / 42 30 / 80 60 / 154 125 / 312 0 / 480 0 / 480 440-480 VAC 15 / 21 15 / 21 15 / 21 30 / 40 30 / 40 60 / 77 125 / 156 250 / 302 500 / 590 500 / 590 600 VAC / 22 / 22 / 22 50 / 52 50 / 52 75 / 77 150 / 4 350 / 336 500 / 472 500 / 472 125 VDC (1) 3 / 25 3 / 25 3 / 25 3 / 25 3 / 25 7.5 / 58 15 / 112 / 8 250 VDC (2) 5 / 5 / 5 / 10 / 38 10 / 38 / 38 40 / 0 50 / 173 Mechanical endurance Endurance (number of operating cycles) 10 000 10 000 10 000 10 000 10 000 10 000 8 000 6 000 5 000 5 000 Operating torque (lbs.in / Nm) 31 / 3.5 31 / 3.5 71 / 8 71 / 8 71 / 8 71 / 8 90 / 10.2 150 / 17 586 / 66.2 586 / 66.2 Connection Min. connection cross-section/ (mm 2 ) (2) # # #10 #10 #10 #10 #6 #2 or 2 x #6 2 x #2 2 x #2 Max. connection cross-section/ (mm 2 ) (2) #10 #10 #6 #6 #2/0 #2/0 300MCM 600MCM or 2 x 350MCM 2 x 600MCM 2 x 600MCM (1) 2 pole in series. (2) 3 pole in series. (3) UL 489/CSA22.2 #5. Dimensions (in/mm) CD 30 A / CC - Frame size 1 H Z F 1 fuser_655_a_1_x_cat AA N N1 H1 Switch body Switch mounting Connection Rating (A) / Fuse Unit F H H1 1 N N1 AA Z in 3.78 3.28 5.19 1.47 0.59 3.13 1 4.56 1.12 CD 30 A / CC mm 96 83.5 132 37.5 15 79.5 25.5 116 28.5 292 General Catalogue 17-18

CD 30 A / - Frame size 2 H F Z 1 fuser_656_a_1_x_cat Switch body Switch mounting Connection Rating (A) / Fuse Unit F H 1 N N1 AA Z in 4.13 3.89 1.47 0.59 3.30 1 4.56 1.12 CD 30 A / mm 105 99 37.5 15 84 25.5 116 28.5 30 to 60 A / - Frame size 4 1.41 36 5.87 9.3 1.46 37.2 1.41 36 4.84 123 5.35 136 4.02 102.1 fuser-ul_001_a_1_x_cat AA N N1 Note for width : For 2 pole device decrease overall width by 1.41 in / 36 mm. For 4 pole device increase overall width by 1.41 in / 36 mm. General Catalogue 17-18 293

Dimensions (in/mm) (continued) 60 to 100 A / - Frame size 5 5.87 9.3 1.41 36 1.46 37.2 1.41 36 4.81 122.2 7.32 186 6.77 172 5.23 133 fuser-ul_002_a_1_x_cat Note for width : For 2 pole device decrease overall width by 1.41 in / 36 mm. For 4 pole device increase overall width by 1.41 in / 36 mm. 0 A / - Frame size 6 7.72 196.2 6.61 168 6.18 157 5.28 134.2 6.50 165.2 7.67 195 11.46 291.3 fuser-ul_003_a_1_x_cat 1.41 36 5.11 130 Note for width: For 2 pole device decrease overall width by 1.96 in / 50 mm. For 4 pole device increase overall width by 1.96 in / 50 mm. 1.96 50 294 General Catalogue 17-18

400 A / - Frame size 7 7.09 180 4.37 111 0.29 7.5 Ø 0.35 Ø 9 Ø 0.27 Ø 7 10.24 (3P) - 12.83 (4P) 260 (3P) - 326 (4P) 198 (3P) - 264 (4P) 198 (3P) - 264 (4P) 7.99 / 3 3.98 3.98 101.5 101.5 15.35 390 2.95 9.44 75 240 2.95 75 7.64 194 8.23 9 0.98 25 fuser-ul_004_d_1_x_cat 2.6 2.6 3.27 66 66 83 Note for width: For 2 pole device decrease overall 3 pole width by 2.59 in / 66 mm. 600 to 800 A / - Frame size 8 min 10.43 min 265 9.84 250 6.10 155 3.12 79.5 3.36 85.5 0.43 11 fix 11.18 (3P) - fix.88 (4P) fix 284 (3P) - fix 378 (4P) 2.56 1.34 65 34 0.27 7.96 380 0.27 7 2.32 59 0.27 7 11.81 300 Note for width: For 2 pole device decrease overall 3 pole width by 3.7 in / 94 mm. 3.54 90 11.81 300 3.36 85.5 10.23 260 fix 9.84 fix 250 5 126.5 Ø 0.51 Ø13 2 51 3.7 3.7 94 94.33 (3P) - 18.03 (4P) 364 (3P) - 458 (4P) 0.35 9 18.54 471 fuser_631_b_1_gb_cat General Catalogue 17-18 295

Dimensions (in/mm) (continued) 30 to 400 A Front direct handle 1.57 40 1.79 45.5 600 to 800 A Front direct handle 2.36 60 5.31 135 External handle dimensions (in/mm) CD 30 A - Frame size 1 / 2 sirco-ul_027_a_1_x_cat 7.48 190 3.35 85 sirco_267_b_1_x_cat Handle type Front operation Direction of operation Side operation Direction of operation Door drilling S0 type Ø 3.07 Ø 78 1.45 37 3.46 88 0 90 I 0 90 I With 4 fixing screws 1.57 40 4 Ø 0.27 4 Ø 7 1.1 28 Ø 1.22 Ø 31 With fixing nut 0.11 3 0.53 13.5 Ø 0.88 Ø 22.5 fuser-ul_015_a_1_gb_cat CD 30 to 60 A - Frame size 1 / 2 / 4 Handle type Front operation Direction of operation Door drilling Side operation (1) Direction of operation Door drilling S1 type Ø3.07 Ø78 1.73 44 2.75 70 0 65 90 TEST I 4 Ø 0.27 4 Ø 7 Ø 1.46 Ø 37 0 90 I 4 Ø 0.27 4 Ø 7 Ø 1.46 Ø 37 fuser-ul_015_b_1_gb_cat (1) Not for frames 1 and 2. 296 General Catalogue 17-18

External handle dimensions (in/mm) 60 to 400 A - Frame size 5 / 6 / 7 Handle type S2 type Ø3.07 Ø78 TEST 0 90 Front operation Direction of operation Door drilling I Ø 1.46 4 Ø 0.27 Ø 37 4 Ø 7 Side operation Direction of operation Door drilling I 0 90 4 Ø 0.27 4 Ø 7 Ø 1.46 Ø 37 1.77 45 4.92 125 65 fuser-ul_016_b_1_gb_cat 600 and 800 A - Frame size 8 Front operation Handle type Direction of operation Door drilling S3 type Ø 3.07 Ø 78 90 I 4 Ø 0.27 4 Ø 7 Ø 1.46 Ø 37 0 2.40 61 8.27 210 fuser-ul_017_b_1_gb_cat Terminal lugs (in/mm) 0 A 400 A 400 A 600 to 800 A 1.52 38.8 1 25 0.45 Ø11.6 1.3 35 2.8 71.5 Ø 0.4 Ø 4.7 0.63 15.88 1.94 49.30 2.88 2 73.15 51 0.53 13.46 3.15 80 0.40 Ø10.2 1.49 38 1.12 28.6 sirco_115_b_1_us_cat 1.8 46 0.44 11.13 sirco-ul_010_a_1_us_cat 1.19 30.23 0.25 6.35 1.25 31.75 sirco-ul_026_b_1_us_cat 2.87 73 sirco_116_b_1_us_cat 300 kcmil 600 kcmil 2 x 350 kcmil 2 x 600 kcmil max General Catalogue 17-18 297