TOA INTERCOM SYSTEM TELEPHONE LINE INTERFACE

Similar documents
N-8000 SERIES IP INTERCOM SYSTEM

Installing And Programming The Off-Premise Extension Interface On The Digital Communications System

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

SERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)

Aristel AN4004 GSM FIXED WIRELESS TERMINAL MANUAL V3.1. This manual contains important information. Please read before using the equipment.

INSTALLATION INSTRUCTIONS

Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems

Nokeval. FD100 series. User Manual

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA

SERVICE MANUAL MODEL SSW-321-X

M-1264 M-1212E STEREO MIXERS. TOA Corporation OPERATING INSTRUCTIONS. TOA 1000 series CAUTION

DI-100 DIRECT SELECT INTERFACE DI-110

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

No. 1. The World s in Compactness. Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES panasonic.net/id/pidsx/global

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

V-9964 Digital Feedback Eliminator/Message Stacker

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

Motorised actuator 0-10V EAC

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

Signal Tower KombiSIGN 50

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

bi-way starter kit lbb 7026/65 MI v.1.2 mounting guide

8. Electric Lock Connection

SERVICE MANUAL MODEL SSW-520-F

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

MODEL: 40DN. Digital Panel Meters 40 Series

TECHNICAL MANUAL EDITION 1.4 SENTRY TECHNICAL MANUAL

NTSC TOA's Digital Video Recorder series combine high reliability with all the advantages of scalable expansion flexibility.

TECHNICAL MANUAL. 25H/DDA One button DDA audio intercom kit TECHNICAL MANUAL EDITION 1.1

SERVICE MANUAL MODEL SSC-303-D (FORMERLY 303-DS)

Intercom Installation The b-red. KIT audio entry control systems AKW200/201

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

Fiberoptic G.703 Codir - IEEE C37.94 converter, Technical manual. Technical Manual 90_20_0101_r2.doc

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE

INTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual

TOA ELECTRIC CO., LTD.

INSTALLATION GUIDE. AXIS 291 1U Video Server Rack ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

CERBERUS. Cerberus multi I/O. Datasheet. Shaping the future of sound reinforcement. Cerberus. Applies to Part Number:

Technical Practice BP-2 POWER FAILURE TRANSFER UNIT. Issue 8, April 1988

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

System Components Surge Arrester HAW 261 and HAW 262

Digital Home Network system Doorphone

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

GV-EL124S Electric Strike

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

SERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS)

The World s in Compactness. * Among photoelectric sensors with built-in amplifier, as of June 2015 (survey by our company)

SERVICE MANUAL. MODEL SSW-321-Fr1

N-8000 Series IP Intercom System

INTEGRATED VOICE EVACUATION SYSTEM

IP INTERCOM SUBSTATION INTERFACE UNIT N-8010RS INSTALLATION MANUAL

Improve the appearance and accessibility of your rack

Wireless Key fob, Key pad & Receiver Range

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

LINKEO ENCLOSURES TO FIT YOUR SCS INSTALLATIONS AND BUDGET EDITION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SERVICE MANUAL MODEL SSW-521-D2-ADA

SERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE

Improve the appearance and accessibility of your rack

INSTRUCTION MANUAL SEPARATION KIT RMK-4

PAGING HORN SPEAKERS SC-630/SC-630M. Both high-impedance (70V/100V lines) models and lowimpedance (8Ω) models available.

THROWMASTER 409 T-1 System Transfer Set

Automated Remote Messaging ARM-911A RM-911D RM-911W

SP-5T Common Line Intercom System

EAR K. Installation and Programming. Manual

F271XA Fiber-Optic Telephone Modem Technical Manual

V-9964 Digital Feedback Eliminator/Message Stacker

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

TELIKOU Intercom System. FM Wire Matrix Control Station. Instruction Manual

User Manual. BP-319 / BP-351 User Station

Installation instructions for Aluminium Pantel, Pancode and Pancam C & T Telephone door access control units

WIDE-DISPERSION SPEAKER SYSTEM F-1000/F-2000 SERIES

Access Control for Houses 2 Wires Connection Doorline DR-200-SET Surface Mount Doorline DR-200-AV-SET Flush Mount

8848 GSM FWT (GATEWAY) USER S MANUAL

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

Useful Notes: Guide to Railway Telephones

INTERCOM SYSTEM Model ICA900

ISDN PABX System. Installation Manual. Profi Line: AS 100 IT

Temperature Measurement

DS-8. CircuitWerkes. Technical Manual. Touchtone Sequence Decoder

SA-36 PTZ series SS316L analogue PTZ camera station

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Temperature Switches

MULTIWAY 2-12 WAY DOOR ENTRY SYSTEM

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

Switching Power Supply

ATP-24A/PCI(2.0) ATP-24A/PCI+(2.0) ATP-24A/PCIe(3.0) ATP-24A/PCIe+(3.0) Analog Tap Passive Board

IP Intercom System. N-8000 Series. Sounding bells, stamping feet, screaming children yet still be notified clearly and in good time of every danger.

Intercom User Manual v1.1

DSTS5 DUAL STANDARD (DTMF/PULSE) TEST TELEPHONE

LB20 Premium Subwoofer

Transcription:

OPERATING INSTRUCTIONS TOA INTERCOM SYSTEM TELEPHONE LINE INTERFACE TD-600 Please follow the instructions in this manual to obtain the optimum results from this manual. We also recommend you to keep this manual handy for future reference. TOA Corporation

CONTENTS General description Part description Connections 1. Power connection 2. Intercom line connection 3. Telephone line connection 4. Facsimile connection Exchange DIP switch setting and programming Signal mode adjustment and setting 1. Receiving sound volume adjustment 2. Adjustment of current supplied to telephone 3. Jumper wire connection 4. Polarity reverse signal control Call operations Installation Specifications Accessories 2 3 4 4 5 6 6 7 8 9 10 10 11 12 12 GENERAL DESCRIPTION By using the TD-600 telephone interface in conjunction with TOA' s intercom exchange, a pushphone (*DTMF) can be used as a handset intercom station. Two pushphones can be connected per interface. DTMF=Dual tone multi-frequency 2

PART DESCRIPTION [Front view] Power indicator CH1 telephone hook-off indicator CH2 telephone hook-off indicator [Rear view] Earth terminal (Be sure to ground.) Power supply terminal CH2 intercom line terminal CH2 telephone line terminal CH1 intercom line terminal CH1 telephone line terminal 3

CONNECTIONS 1. Power connection TD-600 24V DC power supply [AD-242A (2.5A) etc] 2. Intercom line connection 2.1 When using EXES-6000 exchange TD-600 CH2 intercom line terminal CH1 intercom line terminal Twisted pair cable etc. EXES-6000 series exchange YR-810/801 BX-610/620 4

2.2 When using EX-200 exchange TD-600 EX-200 exchange CH2 intercom line terminal intercom line terminal LM-20 Twisted pair cable etc. Note: Perform jumper wire settings as instructed in page 9. 3. Telephone line connection TD-600 CH2 telephone line terminal CH1 telephone line terminal Usable telephones 1) DTMF type 2) Type with line impedance of 600 DTMF telephone 5

4. Facsimile connection TD-600 CH2 telephone line terminal CH1 telephone line terminal To facsimile line terminal Facsimile Note: Usable facsimiles are restricted that selecting signal is transmitted a pushphone. EXCHANGE DIP SWITCH SETTING AND PROGRAMMING All the lines or exchanges to connect the TD-600 should be set to the continuous call tone. 1. When using EX-200 exchange Perform the handset station registration with the station No. 24. Handset station No. Handset station No. 2. When using EX-600 exchange Set the DIP swtich (SW-B-1) of CP-60 to ON to select the continuous call tone. 3. When using EX-610/620/630 exchange Set the DIP swtich (SW-E-8) of CP-66 to ON to select the continuous call tone. 6

SIGNAL MODE ADJUSTMENT AND SETTING Perform the signal mode setting before the final installation or wiring work because the setting requires the removal of the top cover. Remove side plate screws (four places). Detach the top cover. 1. RECEIVING SOUND VOLUME ADJUSTMENT The receiving sound volume can be adjusted in 8dB steps by switching SW3 setting as shown in the figure below. Position of SW3 is factory-preset to "1". Note: Position of SW3 Receiving sound volume step 1 0dB 2 + 8dB 3 + 16dB 4 + 24dB Position 1 of SW3 is set to 0dB. [Rear] [Front] 7

2. ADJUSTMENT OF CURRENT SUPPLIED TO TELEPHONE The distance between the TD-600 and telephone can be made greater by making switch positions of both SW1 and SW2 identical to adjust the current to be supplied to the telephone. See the table below. The line loop resistance is factory-preset to 0~1500 Positions of SW1/SW2 Line loop resistance ( ) 1 0~1500 2 1500~2000 3 2000 or more [Rear] [Front] 8

3. JUMPER WIRE CONNECTION (When using the EX-200 exchange) Referring to Table 1, change settings of jumper wires JP1-JP3. All jumpers are factory-preset to the EXES-6000' s settings. Table 1 Exchange Jumper JP1 JP2 JP3 EXES-6000 Jumper installed Jumper installed Jumper not installed EX-200 Cut jumper Cut jumper Install jumper [Rear] [Front] 9

4. POLARITY REVERSE SIGNAL CONTROL When connecting the telephone line terminal to equipment that must not receive the polarity reverse signal, install the jumper wire in place marked with JP4 in the figure. Jumper JP4 is not factory-preset because the polarity reverse signal is set to transmit from the CH1 or CH2 telephone line terminal. [Rear] [Front] CALL OPERATIONS (1 )Lift up the handset and confirm that a dial tone is audible. Dial the desired station number within 10 seconds. (2)Replace the handset when terminating the conversation. (3)The intercom station's dial key corresponds to dial key of the pushphone. [Example] Intercom station (All call paging) Pushphone (All call paging) Dialing must be completed within 10 seconds after lifting up the handset. If incomplete, no dial signal can be transmitted to the exchange even when the dial keys are pressed. Thus, the pushphone cannot be used for functions such as call transfer, speech message, busy call back etc. to dial during the conversation. When transmitting the DTMF signal during the conversation in conunction with the TI-20 or TI-600 tie-line unit etc., do not press any button of pushphone. This will lead to malfuction of the exchange. 10

INSTALLATION Rack mounting Attach supplied brackets to the TD-600 to mount it in the rack. M3 Washer M3 Binding head screw M5 Rack mounting screw Rack mounting bracket Fiber washer Unit can not be built in the inside of EX-610/620 exchanges. Mount it using the optional CR-271N or CR-392N cabinet rack. Desk-top application Attach supplied rubber feet to holes ( ø 2.5mm) on the bottom surface (four places). Rubber foot 11

SPECIFICATIONS Operating voltage Current consumption Applicable telephone Permissible line resistance Frequency response Max. output signal level Line output DC voltage Ringing tone Line capacity Line connection Installation method Ambient temperature range Dimensions Finish Weight + 24V DC (20V~28V) 250 ma max. DTMF type 2500 (loop) 300~3400 Hz -10 dbm -48V 75V, 16Hz 2 lines Screw terminal Desk top or rack mounting 0 C~40 C (32 0 F~104 0 F) 432(483)(W)x44.5(H)x298(D) mm (17.01(19. 02) x 1.75 x 11.73 in.) Panel: metallic gold Case: colored steel plate-dark grey (Munsell N3.0) Rack mounting bracket: metallic gold 3.3kg (7.3lb.) ACCESSORIES Rack mounting bracket Rack mounting screw (M5x12 tapping screw) Fiber washer Binding head screw (M3x6) M3 washer Rubber foot Installation manual 2 4 4 4 4 4 1 TOA Corporation KOBE, JAPAN 133-06-171-00

TD-600 Please see the reverse side for English manual.

EXES-6000 EX-200 EX-600/610/620/630 EXES-2000

CH1 CH2 CH2 CH2 CH1 CH1 3

TD-600 TD-600 4

TD-600 TD-600 5

6 TD-600

<CH 1 > <CH2> 7

<CH1> <CH2> 8

EXES-6000 EX-200J 9

<CH1> <CH2> 10

M3 M3 M5 11

133-06-171-00