Heavy Duty Datalogger Module

Similar documents
Heavy Duty Datalogger Module

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

3-Axis G-Force Datalogger

User's Guide. Cup Thermo-Anemometer. Model AN400

Integrating Sound Level Datalogger Model

User s Manual. Model and Sound Level Calibrators

Heavy Duty Mini Vane CFM Thermo Anemometer

Digital Vane Thermo-Anemometer Model

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

User's Guide. Datalogging Light Meter with PC Interface. Model

User's Guide. Model Laser Photo Tachometer

Heavy Duty Datalogging Light Meter

Heavy Duty Vibration Meter

True RMS AC Voltage/Current Datalogger

User's Guide. Heavy Duty Differential Pressure Manometer. Model

User's Guide. Temperature / Humidity Datalogger. Model 42270

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

Heavy Duty CFM Thermo-Anemometer Model

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

User's Guide. Hot Wire Thermo-Anemometer Model

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

User's Guide. Vibration Meter and Laser Combination Tachometer Model

Mini Photo Tachometer Model Mini Contact Tachometer Model

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

User's Guide. Video Borescope. Model BR100

User's Guide Video Borescope Model BR200

User's Manual Sound Level Alert Model SL130

Hygro Thermo-Anemometer Model

User Guide. Moisture Meter. Model MO250

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

User's Guide. Digital Sound Level Meter. Model

SuperHeat Psychrometer Models RH350 and RH355 (kit)

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

User's Manual. Digital Sound Level Meter. Model

Dual Input, 3-Display Thermometer/Datalogger Model

Power Analyzer Datalogger Model

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

Laser Photo/ Contact Tachometer. m/min. ft/min

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

APO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

Heavy Duty Psychrometer + IR Thermometer Model HD500

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide. Phase Sequence and Motor Rotation Tester Model

Digital Sound Level Meter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. Model High Precision Quad Output DC Power Supply

12-Channel Thermocouple Datalogger

Datalogging Hygro-Thermometer

User's Guide. Extech AM A AC Analog Clamp Meter

4-Channel Thermometer / Datalogger

3 Channel Datalogging Thermometer

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

Hygro-Thermometer / Datalogger

Barometric Pressure / Humidity and Temperature Datalogger

User Guide. ExStik FL700. Fluoride Meter

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. Mini Microscope. Model MC108

ph/orp Meter SD Card real-time Datalogger

Vibration Meter SD Card real-time datalogger

Light Meter SD Card real-time datalogger

Mini Digital Multimeter

Sound Level Meter SD Card real-time Datalogger

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

User's Guide. Datalogging Hygro-Thermometer Model SD500

User's Guide. 3 Channel Datalogging Thermometer Model SD200

Datalogging Hygro-Thermometer

Heavy Duty Hot Wire CFM Thermo-Anemometer

Heavy Duty Vibration Meter

4-Channel Vibration Datalogger

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Temperature & Humidity Datalogger

User's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700

Indoor Air Quality Meter/Datalogger

3-Axis G-Force Datalogger

Datalogging Hot Wire CFM Anemometer

RS Stock No Instruction Manual RS Input Data Logging Thermometer

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Humidity & Temperature Datalogger

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200 UNITS NEXT AREA RECALL. cf m/cmm Anemometer Thermometer AN200

Large Vane CFM/CMM Thermo-Anemometer

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

Anemometer SD Card Datalogger. Instruction Manual

Vibration Meter and Laser Combination Tachometer

Visible Light SD Card Datalogger

User's Guide. Hot Wire Thermo-Anemometer. Model

Datalogging Conductivity/ TDS Meter. Instruction Manual

Large Vane CFM/CMM Anemometer / Psychrometer

RH/Temperature SD Card Datalogger. Instruction Manual

USER GUIDE. Differential Thermometer Datalogger. Model HD200

User Manual. Thermocouple Datalogging Thermometer. Model EA15

Heavy Duty Datalogging Light Meter

Humidity & Temperature Datalogger

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments

Transcription:

User's Guide Heavy Duty Datalogger Module Model 380340

Introduction Congratulations on your purchase of Extech s 380340 Datalogger Module. The Datalogger connects to and records data from Extech Heavy Duty Series Meters. The sample rate at which data is recorded is user selectable. Readings stored in the Datalogger can later be transferred to a PC using the supplied software and communication cables. This device is shipped fully tested and, with proper use, will provide years of reliable service. Meter Description FRONT PANEL VIEW 1. Input / Output terminals 2. LCD Display 3. Buttons 4. Battery compartment (on rear) 5. AC adaptor input AUTO MANUAL % REC OUT 1 2 3 5 4 TOP VIEW 1. Optically isolated INPUT jack 2. Optically isolated OUTPUT jack 3. Non-isolated INPUT jack 4. Non-isolated OUTPUT jack TOP VIEW ISOLATE DIRECT IN OUT IN OUT 1 2 3 4 BUTTON DESCRIPTION 1. Power switch 2. Date/Time 3. Function 4. Enter/Clear 5. Sample Rate 6. Pause 1 2 3 4 5 6 2

Compatible Meters Model No. Meter Type Display In/Out Port COM Cable 407026 Light Meter Single Direct UPCB-01 407112 Vane Anemometer Dual Direct UPCB-01 407113 Vane Anemometer Dual Direct UPCB-01 407114 CFM Thermo-Anemometer Dual Direct UPCB-01 407117 Mini Vane Thermo-Anemometer Dual Direct UPCB-01 407119 Hot Wire CFM Anemometer Dual Direct UPCB-01 407119A Hot Wire CFM Anemometer Dual Isolated UPCB-02 407123 Hot Wire Anemometer Dual Direct UPCB-01 407227 ph / mv / Temperature Dual Direct UPCB-01 407303 Conductivity Meter Dual Direct UPCB-01 407401 Dual Thermometer Dual Direct UPCB-01 407412 Thermo-Anemometer / Humidity Dual Direct UPCB-01 407428 IR Thermometer Single Direct UPCB-01 407445 RH / Temperature Meter Dual Direct UPCB-01 407495 Pressure meter Single Direct UPCB-01 407510 Dissolved Oxygen (DO) Meter Dual Direct UPCB-01 407768 Sound Level Meter Single Isolated UPCB-02 407777 Moisture Meter Single Direct UPCB-01 407820 Torque Meter Single Direct UPCB-01 407850 Vibration Meter Single Direct UPCB-01 407907 RTD Thermometer Single Direct UPCB-01 407910 Differential Pressure Manometer Single Direct UPCB-01 42525A IR Thermometer Single Isolated UPCB-02 475055 Force Gauge Single Direct UPCB-01 3

Operation Note: The Heavy Duty Meters have an Auto-Shutoff feature that automatically turns off the meter (after 10 to 30 minutes depending on the model). This feature must be disabled during a datalogging session. Press the RECORD button on the meter to disable the Auto-Shutoff feature. Setting the Date and Time The actual date and time should be programmed into the data logger prior to use. To program the date and time: 1. Turn the data logger on. 2. Press the Date/Time button to enter the date and time setting mode. 3. While in the date and time setting screen hold down the Date/Time button until SET appears on the screen, then release the Date/Time button. The screen will begin blinking. 4. While the screen is blinking, pressing the Date/Time button allows the user to scroll through Year, Month, Date, Hour, Min and Sec. 5. While the screen is still blinking, press the up arrow, (Function Button), to adjust the number on the screen to the desired year, month, date, etc. Holding the up arrow button down allows for rapid changing of the numerical value. 6. When the desired date and time is programmed, the logger will exit the time and date setting function after a few seconds with no button presses. Automatic Datalogging This function sets the Datalogger to automatically collect readings at a sample rate set by the user. 1. Connect the Dataloggers IN port to the Heavy Duty Meter as shown in the illustration. (The supplied UPCB-03) cable connects the meter to the Datalogger). Use the Isolated or Direct port on the Datalogger according to the chart on page 3. 2. Turn the power on. 3. Press the Function button until AUTO is displayed on LCD. 4. To set a new recording interval Press and Hold Sample Time button until display flashes SET and HOUR. Press to set hour. Then press Sample time to go to minutes Press to set minutes. Then press Sample time to go to seconds Press to set seconds. Then press Enter to save your interval setting. Begin Automatic Datalogging 1. Press the PAUSE button to begin logging. The display will change from PS to RC and begin logging. 2. Press PAUSE again the stop logging. 3. Use the PAUSE button to toggle recording ON (resume) and OFF (pause). When datalogging is resumed, new readings are recorded right where the datalogger left off so that readings are not overwritten. 4

Clearing Logger Memory 1. Press and hold Clear button until CLR appears and display begins to flash. The number displayed shows the % of memory used. 2. Press to select YS (Yes) 3. Press Enter. Display will flash 00. Memory is now clear. NOTE: Data will remain in memory until the Datalogger memory is cleared (see previous section) or until the batteries are removed. Manual Datalogging Manual datalogging allows the user to record one reading at a time. 1. Turn the Datalogger On. 2. Press the Function button until MANUAL is displayed on the LCD. 3. Press the PAUSE button to log one measurement. Display will change from PS to RC and return to PS each time a recording is made.. 5

AUTO MANUAL % REC OUT Transferring Data to a PC Once data is collected, the next step is to connect the Datalogger to a PC and transfer the collected readings. Hardware Connection Connect the Datalogger s OUT port to the PC COM port shown) via the supplied 3.5mm phono to DB-9 cable. the compatible meter list for the correct cable and OUT your meter.. Windows TM Datalogger Software (as Refer to port for Install the supplied software from the Windows TM program CD-ROM using the instructions provided on the CD-ROM. The following software screen will appear. Software Screen Description 2 1 5 4 6 3 7 1. COM Port Selection (Use pull down menu to select port) 2. Data Transfer Status 3. Transferred Data View 4. Data File Name (type desired filename) 5. Number of readings 6. Instructional steps describing the data transfer process (additional steps are listed in the next section). 7. Function buttons: START (click to begin data transfer); VIEW DATA (click to see all transferred data as shown in item 3 above), and EXIT (click to close program) 6

Data Transfer To transfer data from a Heavy Duty meter to a PC. 1. Connect appropriate cable to PC and the logger. (See Compatible Meter List) 2. Power the Datalogger. 3. Select your com port. 4. Type a file name in the Data File Name field on the software screen. 5. Click on the START key in the software window 6. Press the Function button until LCD displays OUT 7. Press the PAUSE button on the Datalogger to begin the data transfer. 8. The LCD will count down as it transfers your data. 9. Press the PAUSE button to halt the transfer. 10. After the data points have been transferred, turn off the datalogger. Data will remain in the datalogger as long as the batteries are fresh. The data points are transferred to the file named in step 4 above. To view the transferred data, click the VIEW DATA button on the software screen. Record Format The file stored on the PC can now be opened in other applications such as spreadsheet, wordprocessor, database or graphics programs. Records are comma delimited. When imported, each reading will appear as follows. 1,"060306120458","Time" 2,1173,"LUX " Row ID, Time stamp, Unit Row ID, Reading, Unit Note: Each time stamp is saved as a 16 character reading as follows. Year, Month, Day, Hours, Minutes, Seconds Battery Replacement Slide the rear battery cover off in the direction of the arrow. Replace the four AA batteries and secure the battery compartment cover. 7

Specifications Input type Data storage Display Adjustable Sample Rate Software compatibility Internal Clock Memory Batteries Battery life Power consumption RS-232 data stream 8000 readings (16 bits each) LCD 1 second to 8hrs 59 minutes 59 seconds Check the software download page of the extech.com website for the latest version of the PC software and its operating system compatibility Crystal oscillator Non-volatile; Data is retained at power down Four 1.5V AA batteries (alkaline or heavy duty type) 36 hours continuous (typical) Approx. 3.7mA DC Operating temperature 32 to 122 o F (0 to 50 o C) Operating humidity Weight < 80 % RH 0.45 lbs. (205g) including battery Dimensions 5.2 x 2.8 x 1.0" (131 x 70 x 26mm) (H x W x D) 8

Warranty FLIR Systems, Inc. warrants this Extech Instruments brand device to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department for authorization. Visit the website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. FLIR Systems, Inc. specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. FLIR s total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration, Repair, and Customer Care Services FLIR Systems, Inc. offers repair and calibration services for the Extech Instruments products we sell. NIST certification for most products is also provided. Call the Customer Service Department for information on calibration services available for this product. Annual calibrations should be performed to verify meter performance and accuracy. Technical support and general customer service is also provided, refer to the contact information provided below. Support Lines: U.S. (877) 439 8324; International: +1 (603) 324 7800 Technical Support: Option 3; E mail: support@extech.com Repair & Returns: Option 4; E mail: repair@extech.com Product specifications are subject to change without notice Please visit our website for the most up to date information www.extech.com FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA ISO 9001 Certified Copyright 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 9