APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 1 A P K I T K P C O L O U R V I D E O D O O R E N T R Y S Y S T E M U S E R M A N U A L w w w. e s p u k. c o m
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 2 Contents System Components...................................................................... 3 Installation............................................................................... 4 System Connections Example 1............................................................ 5 System Connections Example 2............................................................ 6 Lock Connections Example 1.............................................................. 7 Lock Connections Example 2.............................................................. 7 Door Station Programming Guide.......................................................... 8 User Guide.............................................................................. 10 Installer s Guide......................................................................... 11 System Cabling All system cabling (excluding mains 240vAC supply) has been tested with Cat5E UTP PVC cable. Part Number - A8NFORCE5EUTP Find this product online: elandcables.com Cables & Accessories LAN Cable Cat 5E UTP PVC Cable 2
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 3 System Components APDSSWKP Door Station APMONW Monitor APPOWSW System Power Supply Optional Accessories EVBPSBB Lock Power Supply EV-EXIT Push To Release EV-EBG Emergency Release EV-ML-250/500XT Electro-magnetic Lock ENTERD Electric Lock 3
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 4 Installation 90 1.2 m 1.5 m Site the door station a recommended 1.5 meters from the ground, or to suit application. The camera needs to point in the direction of where a visitor will stand during operation. Avoid areas of high sunlight and noise levels. Surface mount the sunshield of the door station and connect the system cabling. Mount the camera to the sunshield by fixing with the supplied hex screw. 1-Gang Mount Box (if required, not supplied) Monitor Monitor Mounting Bracket Site the indoor monitor to suit application. Surface mount the bracket of the monitor or if required onto a 1-gang mount box (not supplied). Make the system connections to the back of the monitor and then slide the monitor onto the bracket using the hooks to hold firmly in place. 4
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 5 System Connections Example 1 MASTER Set dipswitch 6 to ON All other switches set to OFF POWER SUPPLY 240vAC INPUT Total cable run should not exceed 150 meters between door station and monitor Power supply to be with-in 100 meters of monitor No cable or connection polarity 01 Ensure the switches are both set to OFF 5
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 6 System Connections Example 2 The system power supply can support up to 5 devices Total cable run should not exceed 150 meters between door station and monitor Power supply to be with-in 100 meters of monitor No cable or connection polarity SLAVE SLAVE 1 2 Only one monitor is set as the MASTER: MASTER= ON 6 7 OFF All other monitors set as SLAVE: SLAVE= ON 6 7 OFF 02 POWER SUPPLY 240vAC INPUT MASTER 3 Refer to instructions supplied when using different version of monitor for MASTER/ SLAVE configuration 01 01 02 03 04 When using multiple door stations ensure that each unit has a seperate The dipswitches are accessable on the rear of the door station 6
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 7 Lock Connections Example 1 Lock Connections Example 2 Electro-magnetic lock _ + Electronic lock The jumpers on the rear of the door station offer different types of release modes for alternative applications dependent on the jumper link settings. LOCK1 options; The door station has a secondary switch. LOCK2 options; 4 3 NC + _ + _ Lock -release time N.C for Electro-magnetic lock N.O for Electronic lock Image of jumper link N.O System Wiring LOCK1 VCC N.O Volt-free 3 2 1 N.C Volt-free 3 2 1 Volt-free 3 2 1 N.C Volt-free 3 2 1 N.O At the rear of the door station ensure that the jumper links cover pins 1 and 2, on both and positions 3 2 1 Image of jumper link N.O 12vDC300mA MAX 3 2 1 12vDC300mA MAX 3 2 1 Please refer to the operation guide for release instructions 7
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 8 Door Station Programming Guide Entering Administration Mode 2 tones Input administrator code (Default: 123456) 2 tones Administration Mode has been entered The Administrator code will not release the door. A lock release code is required to be programmed Setting a lock release code Enter Administration Mode 2 tones 2 tones Enter 4 digit code required for door release For code location number > Re-enter 4 digit code required for door release A long tone Continue to exit and complete setup 8
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 9 Deleting a lock release code Enter Administration Mode Enter code Location Number 2 tones A long tone to exit and complete setup Changing the Administrator code Enter Administration Mode Enter new 6 digit Administration Code Re-enter new 6 digit Administration Code A long tone to exit and complete setup 9
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 10 User Guide Preview Lock Gate Talk once to view door station image once to release lock once to release lock 2 Chime Volume: Slide switch for High, Medium and Low setting Chime Selection: button to select chime melody Monitor Brightness: Adjustment for brightness levels once to talk to visitor Monitor Chroma: Adjustment for the intensity of colour Talking Volume: Adjust the volume level of the monitor A B C D Then choose between these 3 options The visitor presses the call button A chime The visitor s image will appear on the monitor the Talk button and begin conversation the Talk button to end call the Lock button to release lock and press Talk to end call the Gate button to release lock 2 and press Talk to end call Using the lock release code Enter 4 digit lock release code The lock will release 10
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 11 Installer s Guide Master / Slave Setting When using multiple monitors on 1 system; Only the 1 handset set as the MASTER will display an image when the door station is activated. All other monitors will ring, and will display the image once the Talk button is pressed. In the event of no video or audio signals coming from the monitor, or if the call button or audio cannot be activated on the door station, check the following; A That the system is powered sufficiently. B Each monitor needs to be set to a MASTER or SLAVE position C All system cabling is secured and properly connected. D All system cabling is clear of breaks or short circuits. E Bench test the system if the issue cannot be found. In the event of a lock release issue, check the following; A The user instructions and operation of the monitor has been understood. B That the lock is powered sufficiently. C All system cabling is secured and properly connected. D All system cabling is clear of breaks or short circuits. E On the rear of the door station, ensure the lock output is switching when activated by the monitor. 11
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 12 Elite Security Products Unit 7, Target Park, Shawbank Rd Lakeside, Redditch B98 8YN Telephone: 01527 51 51 50 Fax: 01527 51 51 43 email: info@espuk.com E&OE - Errors and omissions excepted. A16 w w w. e s p u k. c o m