BGP Support for Ipv6. Switch should have virtualization feature as one or more switch can act as a single Switch or equivalent IP clustering

Similar documents
UNIVERSITY OF CALICUT (Purchase Division)

NATIONAL INSTITUTE OF TECHNOLOGY KURUKSHETRA You are invited to submit your most competitive quotation for the following goods:

Tarleton State University. Specifications

Addendum - 1. Passive part - Sheet attached Annexure V - Sheet attached. This clause is removed. This clause is removed

UTP Cat 5e cable (200 MHz) (PVC sheath)

ProCurve Switch 2500 Series

REQUEST FOR PROPOSAL FOR PROCUREMENT AND INSTALLATION SWITCHES AND TRANSCEIVERS MODULES BILL OF MATERIALS

LC Connector. A High Density Fiber Optic Network Solution. Paul Kolesar Lucent Technologies, Bell Laboratories

Quick Start Guide. C-100 Series Switches

KFC-200. Installation Guide

NATIONAL INSTITUTE OF TECHNOLOGY SIKKIM Ravangla Campus, Barfung, South Sikkim Amendment

QuickSpecs. Models. Features and Benefits Connectivity. HP V2124 Switch. HP V2124 Switch. Overview

TENDER DOCUMENT NATIONAL INSTITUTE OF PUBLIC FINANCE AND POLICY. New Delhi SUPPLY OF LAN EQUIPMENTS AND INSTALLATION OF LAN IN THE CAMPUS

TECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5

Addendum & Corrigendum-2 Request for Proposal

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

barpa Values Website & Social Network

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

DynaGST/2402G USER S MANUAL

QuickSpecs. HPE OfficeConnect 1420 Switch Series. Overview. Models. Key features

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

24-Port Gigabit Ethernet Switch w/ 12 Outlet PDU, 2 SFP and 8 PoE+ Ports, 120W

HP G Switch HP G-2SFP Switch HP G-2SFP+ 10G Uplink Switch HP G-PoE+ (124W) Switch

INVITATION FOR QUOTATION. TEQIP-II/2017/CH2G01/Shopping/126

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

CTS-iCPE Gateway Controller User s Manual Version: Revision B1

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

Data sheet C6 A modul 1 port 180 M AP pure white

PATCH-CORD. SC Patch-Cord APPLICATIONS AVAILABILITY FEATURES SPECIFICATIONS. Active device termination Local Area Networks (LANs)

Bill of material for Rack Installation at PAMU Flume Lab :

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/30

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/30

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

HP G Switch HP G-2SFP Switch HP G-2SFP+ 10G Uplink Switch HP G-PoE+ (124W) Switch HPE OfficeConnect G Switch

FRG-3105 Series Residential Gateway

GigaVUE-420 // Data Sheet

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

9/27/04 cci Cablecom Inc. 1

CSRJ456K. White CSC624PP CSRJ456KB CSRJ456K90

ProCurve Switch 1400 Series

Quick Start Guide. Physical Description. The Port Status LEDs

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

AMP NETCONNECT EtherSeal System Bringing Ethernet and Structured Cabling to Non-Office Environments.

Contents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06

Addendum No. 1 January 7, 2015

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Models HP G Switch

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Models HPE PS G Switch

Gigabit Ethernet Switch With 10G Uplinks. Hardware Manual MS400860M

OmniConverterTM. OmniConverter FPoE/SL, FPoE/S and FPoE+/S 10/100 Media Converter with Power over Ethernet (PoE or PoE+) KEY FEATURES

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

QuickSpecs. Models HP G Switch

Summit Virtual Chassis Design and Installation Guide

Data sheet C6 A modul 90 jack

HES-3106-PLUS SERIES

3M Category 6 Copper Structured Cabling System

RuggedNet. RuggedNet GPoE+/Mi KEY FEATURES. Managed Industrial 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

COMOSS FECON Series Media Converter Data Sheet. Overview

Data sheet PM PCC OpDAT patch cord LC-D/LC-D OM3 aqua, 20.0 m

28-Port Stackable L3 Lite Managed Gigabit Fiber Switch, 2 x Gigabit SFP/RJ45 Combo, 2 x 10-Gigabit SFP+, 1 x 10-Gigabit Module Slot

Industrial Gigabit Managed Ethernet Switch

جامعة العلوم والتكنولوجيا األردنية

Retired. IEEE 802.1p prioritization: delivers data to devices by honoring the priority and type of traffic

Material Description Quantity UOM

Pretium EDGE Solutions Trunk Cable, 50 µm multimode (OM3)

10 & 18 port SNMP and Modbus/TCP Capable Ethernet Switches SEC310-2SFP-T, SEC318-2SFP-T

Delegation of the European Union to Bosnia and Herzegovina

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

SPEC SHEET. Multimode Patch Cords and Pigtails. Cable types. Description. Features. Fiber types

Cat.8 Shielded Keystone Jack Description

AMG9204GW-SFP GbE Fiber Managed Switch Installation and Getting Started Guide

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

Industrial 3-Port Fast Ethernet Media Converter Switches

JG962A Datasheet. Overview. Quick Spec. Product Details

QuickSpecs. HPE Altoline 6921 Switch Series. Overview. HPE Altoline 6921 Switch Series

NVT Phybridge, Inc Superior Court, Unit 3 Oakville, ON, L6L 0C4 Phone: Web:

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Prebid clarification / Ammendment No. 1

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

Cat.8 Shielded Field Termination Plug Description

RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana Ref: RGUKT-B/Proc/Firewall/Q104/2016, dated

Technical Queries (Q) and Answers (A)

IEC /IEEE 1613 Lite L3 Hardened Managed 24-port Gigabit SFP. 10GbE Connectivity Four 10G SFP+ for connecting the switch to the core network

SWH-3112 Series 12-port L2+ Managed Gigabit Fiber Switch User s Guide

Great Falls Public School Districts 1 & A th Street South Great Falls, MT February 16, 2018

OmniConverterTM. OmniConverter GPoE+/Sx KEY FEATURES. Unmanaged 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

DINTEK LAN Cabling Systems

Sub : ADDENDUM/CORRIGENDUM for Request for Proposal for Providing Managed Networking Solutions using SDWAN Technology for ESIC Offices across India

Cisco 25GBASE SFP28 Modules

UPGRADATION OF WIRELESS NETWORK OF HOSTELS OF TEZPUR UNIVERSITY

Clarification by APSFL SNo Bidder Section Clause Brief Description of the clause. in Tender Query/ Comments of Bidder

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2)

Transcription:

Minutes of the Pre-Bid Meeting - NATIONAL COMPETITIVE BIDDING FOR THE SUPPLY, Installation and Commissioning of LAN at 9 DH along with 2 ZH F.2 (499)/RHSDP/EPMC/HMIS/ NCB/4881 Dated 09.11.2010 Sl. Description as per the Bid Document Query/Clarification/Suggestion RESPONSE CORE SWITCH 1 2 3 4 5 6 Switch2.2.1.1.1 Central (Core) L3 Switch: Fabric:128Gbps or higher Switch2.2.1.1.1 Central (Core) L3 Switch: Packet Forwarding Rate: 80 Mpps or higher Switch2.2.1.1.1 Central (Core) L3 Switch: Should support GVRP Switch Should support MPLS feature like Multi-VRF feature Should support Layer 3 routing protocol RIP, OSPF, BGP etc for both IPv4 and IPv6. Switch should have virtualization feature as one or more switch can act as a single Switch. Switch Fabric 256Gbps or higher; Min. 104 Gbps; Switch Fabric 108Gbps or Higher is acceptable Packet forwarding Rate: 101 Mpps or higher Min. 65.5 Mpps. GVRP is a very legacy protocol and also involves huge security risk. Using GVRP in the network means if one switch is mis-configured it can erase the VLAN configuration. Change it to "Switch should have a feature like MPLS-Multi VRF"; MPLS feature is not required/pls. remove it BGP Support for Ipv6 Switch should have virtualization feature as one or more switch can act as a single Switch or equivalent IP clustering 7 Internal Redundant power supply Change it to External Power Supply 8 IEC Should support optional stacking on 40GB speed 9 Emissions: FCC Class AEN61000, VCCI, UL, Pls. remove it IEC Should support optional stacking/ip Clustering on 40GB speed Accepted. To be read as Fabric: 88 Gbps or higher. Accepted. To be read as Packet Forwarding Rate: 65.5 Mpps or higher. Accepted. Read it as "GVRP or Equivalent Support." Accepted. To be read as "Internal/External Power Supply." Page 1 of 7

10 Core Switch Rack not mentioned in the Technical Specifications 11 2 no. Transreceiver required with each switch Racks at CORE Switch Location Pls. Confirm on No. of SX (for MM OFC Modules) & LX (for SM OFC Modules) required 12 24 Port Gigabit SFP 8 Combo Ports Instead of 8 change it to 4 13 Optical Fiber (SM & MM) Clarity is required as to where will Single Mode fiber connected with different mode fiber 14 Open Slot for 10G uplink Modules Change it from current 3 to 2 or 4 15 Core Switch L2 EDGE SWITCH 16 Should have Layer 3 Static routes: 16 Clarify whether L3 switch is required at Zenana Hospitals or not This is a Layer 3 Feature, Remove or modify to "Should have static routes for management protocols" 17 Virtual VLAN interface: 8 Change it to 256 VLANs 18 Switch capacity: 54Gbps or higher 19 64-Byte Packet Forwarding Rate: 40 Mpps or higher Pls. keep less than 54Gbps; 54 Gbps and 40 Mpps is too less for Non blocking operation. Hence we request you to please change Switching Fabric to 88 Gbps and Forwarding rate to 65 Mpps; We request not to increase the switch capacity 64-Bytes Packet forwarding Rate: 35.7 Mpps or higher; Change it to 36 Mpps or higher Accepted. Please refer to revised technical specifications whereby it has been clearly defined the Accepted. Transreceiver (Single & Multi Mode) included in System Inventory Table and Price Schedule. Pls. refer Network Drawings annexured with tender document. Accepted. Should be read as Open Slot for 10- Gigabit Uplink Modules: 2 or higher Not required at 2 Zenana Hospitals. For details kindly refer Network Drawings annexured with tender document. Accepted. Switch Should Support at least 256 VLAN's or higher, with Virtual VLAN Interface Page 2 of 7

20 EMI/EMC: FCC Class A,CE Pls. remove 21 Management: NTP/SNTP Keep any One of them 22 Include Out of band management Port Even if the Network Traffic flood the Ethernet Ports present in the front panel of the switch still the IT Manager/ System Administrator has provision to implement Network Policies through Out of band management Port 23 2 no. Transreceivers required with each switch Pls. Confirm on No. of SX (for MM OFC Modules) & LX (for SM OFC Modules) required 24 Network Rack required with each Edge Switch Racks at Edge Switch location Accepted. Transreceivers (Single & Multi Mode) included in System Inventory Table and Price Schedule. Accepted. Please refer to revised technical specifications whereby it has been clearly defined the Sl. Description as per the Bid Document Query/Clarification/Suggestion RESPONSE UTP Cable 25 The OEM should be ISO 9001:2000 & QS: 9000 The OEM should be ISO 9001:2000 Certified Accepted. The OEM Should be ISO 9001:2000 Certified 26 The OEM should have at least 1 site on intelligent system in India. 27 4 Pair with ETL test report for channel and zero bit error 4 Pair with ETL test report or UL listed for channel and zero bit error The Cable Should be UL, ETL Certified, EIA/TIA 568-C.2. 28 UTP Cable Should be RoHS Compliant 29 UTP Cable Should be tested up to 600 MHz 30 The bidder/oem should be able to physically demonstrate intelligent system monitors/scanners, Page 3 of 7

intelligent jack panels etc. if so required. Information Outlet 31 Should be able to support variety of jacks UTP, Should Support UTP, STP Accepted. Read as UTP, STP only STP, Fiber, Coax etc. 32 Jacket PVC Cable Jacket Sheath should be Fire retardant PVC 33 2.2.1.2.3 INFORMATION OUTLET with ETL test report-plug in Icons Icon tree to be supplied with plate Information outlet (RJ45 jack) should be covered under ETL Verification program for compliance with TIA568B.2-1, ETL certificate to be submitted with offer Should be either UL or ETL Certified; Plug-in icons to be supplied with plate Information Outlet should be ETL and UL Certified rest as per tender document. 34 CAT 6 TIA 568B.2-1 250 MHZ Change requested as under: CAT 6 TIA 568 C.2 600 MHz 35 UL UL Certified 36 RoHS RoHS Compliant 37 Max. Temperature 75 C Max. Operation Temp 60 C and Storage Temp 75 C. Jack Panel - Cat -6 38 Be made of cold rolled steel, in 24 port To be Modified configurations. Each jack should have spring loaded shutter inside the jack for 100% dust free environment. Accepted. 39 RoHS RoHS Compliant 40 UL & ETL UL & ETL Mandatory Page 4 of 7

41 Each port / jack on the panel should be individually removable on field from the panel. To be Modified Mounting Cords 42 Should comply to the following : TIA/EIA-568-B.2-1 Component Compliant FCC Subpart F 68.5 Compliant, IEC-603-7 Compliant, ISO 11801 Class E Compliant, UL, 1863, CSA C22.2 43 Should be covered by ETL verification program for compliance with TIA 568B.2-1. Certificate to be CSA C22.2 to be removed Should be either UL or ETL Certified Accepted. CSA C22.2 removed but Jack Panel Should be ETL Certified rest as per RFP. Both UL & ETL are required submitted with bid. 44 Approvals: UL, CSA Pls. remove CSA Accepted. CSA removed. Rest as per RFP. 45 RoHS RoHS Compliant 46 Operating temperature: -40 o C to 85 o C Change requested Accepted. Changed to -40 o C to 75 o C Optical Fiber Cable 47 The OEM should be ISO 9001:2000 & QS: 9000 Certified. 48 The complete cabling system (copper as well as fiber) offered shall be upgradeable to the intelligent system if required in future by retrofitting of sensors. 49 The OEM should have at least 01 site on intelligent system within India. 50 The bidder/oem should be able to physically demonstrate intelligent system monitors (for both copper & fiber), patch cords etc. if so required. 51 Should fulfill the requirements of IEC 793-2: 1992, Category B 1.1, EN 188101, ITU-T Recommendation G.652 FIBER PATCH PANELS RACK MOUNT 52 Should be upgradeable to intelligent patch panel without changing the existing patch The OEM should be ISO 9001:2000 & QS: 9000 Certified Kindly remove Accepted. The OEM Should be ISO 9001:2000, QS:9000 removed Page 5 of 7

53 Have earthing lugs and other accessories. Provide self-adhesive, clear label holders (transparent plastic window type) and white designation labels with the panel, for front panel labeling. Optical Fiber Equipment Cords (min. 3 meter) (Single- Mode) 54 Category B1.1 TIA/EIA-568 B.1-3 Anything better/ more advanced also acceptable 55 All optical fiber patch leads shall comprise of Single mode 9/125µm fiber with SC, fiber connectors terminated at each end. Optical Fiber Cable (Multi-Mode) 56 Indoor riser rated 6 core Multi Mode, 50 micron, OM3 optical fiber cable Fiber Cable should be Loose Tube Dielectric, construction. Fiber cable get more strength and protective in Loose Tube Design. 57 Cable: 9/125, SM Line item # e calls for Single mode fiber patch cords. And item # K should be MM as per BoM. The specified 9/125 SM should be typo error. Hence request you to modify the specs as mentioned Cable: 50/125, MM 58 The work area equipment cords shall, at a minimum comply with proposed ANSI/TIA/EIA-568-B.2-1 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100µ Category 6 Cabling. 59 The cable should consist of 900m tight buffered optical fibers reinforced with Armid Yarns and sheathed in flame retardant PVC. The work area equipment cords shall, at a minimum comply with proposed ANSI/TIA/EIA-568-B.2-1 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100Ω Category 6 Cabling. Fiber cable sheath should be in jacket of Nylon-12 material making in cable anti trestle and best suites for duck-pulling with low frictional coefficient. It should have the Armid Yarn also. Anything better/more advanced also acceptable Accepted. For multimode fiber cable feature should be read as Cable: 50/125, MM Page 6 of 7

60 Fiber Connector (Single & Multi-Mode) Connector should be changed to Pigtail Accepted. Addendum to Technical Specifications. Others 61 Any item not mentioned above and is required for commissioning of the entire system is deemed to be inclusive in the offered solution without any additional financial implication 62 Unit prices of Goods offered from within the Purchaser s Country, shall be quoted on an EXW (ex factory, ex works, ex warehouse or off-the-shelf, as applicable) basis, including all customs duties, levies, fees, sales and other taxes incurred until delivery of the Goods, but excluding all VAT or sales and other taxes and duties/fees incurred for the Goods at the time of invoicing or sales transaction, if the Contract is awarded. Please permit that Bidder can quote unit price for additional items required for the project separately Please clarify that price can be quoted exclusive of Service Tax 63 Supply, Installation & Commissioning - 90 days We request you to please increase Supply, Installation & Commissioning up to 120 days. 64 Section VI Technical Requirements (C. Technical Specifications) 65 Section VI Technical Requirements (System Inventory Table) 66 Section VII Sample Forms (2.3 Supply & Installation Cost Summary Table) 67 Section VII Sample Forms (2.5 Supply & Installation Cost Sub-Table) Accepted. Addendum to Price Schedule. Please refer to ITB clause 14.4 and 14.5 for details Please refer to Implementation Schedule. Please refer to amended technical specifications. Annexure-I Please refer to amended technical requirements (System Inventory Table). Annexure-II Please refer to amended sample forms (Supply & Installation Cost Summary Table). Annexure-III Please refer to amended sample forms (Supply & Installation Cost Sub-Table). Annexure-IV Page 7 of 7