Multichannel Process Display TFT with Contacts, Analogue Outputs and Datalogger Functional range standard configuration of max. 60 channels via inputs, outputs, mathematical / logical functions, controller, profiles or virtual outputs allocation of clogged channels in 0 groups (max. 6 channels per group) connection of channels via mathematical / logical functions 8 integrated PD / PI / PID controller Datalogger data logging of max. 60 channels free selectable measuring rate (max. 0 Hz) extensive trigger functions internal memory,5 GB Product characteristics graphics-capable TFT monitor, touchscreen 3 free fittable slots, 6 different input / output modules transducer supply 24 V DC communication interface: RS-485 (Modbus RTU) Master / Slave, USB-Host-Port, USB device connection front panel housing 96 x 96 mm Optional versions communication interface: 2 x RS-485, x RS-232, 2 x USB-Host-Port, Ethernet 0 MB, RJ-45 Display modes channel display of the individual groups with units, bargraph and scalabled plus standardized horizontal or vertical online course channel display of a group in the diagram with units and scalabled horizontal and vertical bargraph channel display of a group with units and scalabled plus standardized channel display of the individual groups as indicator instrument with units and scalabled plus standardized simultaneous display of max. 5 groups respectively 30 channels with units and scalabled measured values
Technical Data Supply Supply voltage Power consumption Signal input/output Slot A Slot B Output modules Slot C Output modules Inputs with common ground standard: 85 260 V AC / V DC option: 9 50 V DC / 6 35 V AC 5 VA, max. 20 VA R8 I02 I04 R8 R45 S08 S6 I02 I04 4 x 0 0 V + 4 x 0 20 ma 8 x 0 0 V + 8 x 0 20 ma 6 x 0 30 V, binary 6 x 0 0 V 6 x 0 20 ma 4 x PT00 / PT500 / PT000 4 x universal input (0 0 V / 0 20 ma / PTxxx / thermocouple) 4 x 0 0 V + 4 x 0 20 ma 8 x 0 0 V + 8 x 0 20 ma 6 x 0 30 V, binary 6 x 0 0 V 6 x 0 20 ma 4 x PT00 / PT500 / PT000 4 x universal input (0 0 V / 0 20 ma / PTxxx / thermocouple) 8 relays (max. A, 250 V) 2 passive analogue outputs 4 20 ma 4 passive analogue outputs 4 20 ma 4 x 0 0 V + 4 x 0 20 ma 8 x 0 0 V + 8 x 0 20 ma 6 x 0 30 V, binary 6 x 0 0 V 6 x 0 20 ma 4 x PT00 / PT500 / PT000 4 x universal input (0 0 V / 0 20 ma / PTxxx / thermocouple) 8 relays (max. A, 250 V) 4 relays (max. 5 A, 250 V) 8 semiconductor relays (max. 00 ma, 5 V) 6 semiconductor relays (max. 00 ma, 5 V) 2 passive analogue outputs 4 20 ma 4 passive analogue outputs 4 20 ma Transmitter supply DC Communication / Performance Communication interface Type of protection Version without / with USB-port Permissible temperatures Operating temperature 0 60 C Storage temperature -0 70 C Electrical protection Electrical safety EN 600- EMC EN 6326 24 V DC ± 5%, max. 200 ma standard: RS-485 (Modbus RTU), Master / Slave USB Host (on rear panel / front side), USB device option: 3 x RS-485/RS-232, Master / Slave 2 x USB Host, x USB device, x Ethernet 0 MB standard: IP 65 (front foil) option: IP 54 (with lockable front)
Technical Data Miscellaneous Display Housing dimensions Housing Housing material Extended functions Programmable upper / lower deviation messages Programmable display filter Multi lingual menu navigation Integrated date and time display User defined / time controlled profiles Adjustable contrast and brightness of display Acoustical signalling of alarm conditions Screensaver Extensive password protection Data and configuration transfer via USB stick / Ethernet Dimensions (in mm) TFT, 3.5", touchscreen, graphics-capable, coloured (6 bit), 320 x 240 pixels 96 x 96 x 00 mm panel mounting NORYL-GFN2S E mounting hole dimensions installing of brackets
Technical Accessories Data Accessories Licence key for Datalogger function material number LK-700 Authorised for activation of data logging for max. 60 channels. For an additional activating of function for already delivered CIT 700 the serial number is necessary. Software DAQ-Manager Program for display (table or course), archiving, evaluation and export from stored data of CIT 700 with activated data logging. The data are imported via USB removable medium or Ethernet. Export of the data is in CSV format. material number SW-DAQ This software is freeware and may be downloaded from our homepage. Software SimCorder Program for display (table or course), archiving, evaluation and export from active of CIT 700 with / without activated data logging. The data transfer is done via RS-485 interface (max. 6 channels). Export of the data is in TXT format. material number SW-SIM Lockable, transparent door Mini USB Stick 2 GB Converter RS-485 / USB Converter RS-485 / RS-232 material number Z900002 material number Z900003 material number CM- material number CM-2 Prevents damage of display and increases access protection. Enables data and configuration transfer between PC and CIT 700 (also with mounted door). Enables connection of CIT 700 and PC with USB interface. Enables connection of CIT 700 and PC with RS-232 interface. This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.
Ordering Code CIT 700 CIT 700 - - - - - - - Basic version multichannel controller colour TFT dispay touchscreen Slot A 4x voltage input + 4x current input 8x voltage input + 8x current input 6x voltage input, binary 6x voltage input 6x current input 4x RTD input 4x thermocouple input 8x thermocouple input 4x universal input Slot B 4 x voltage input + 4 x current input 8 x voltage input + 8 x current input 6x voltage input, binary 6 x voltage input 6 x current input 4 x RTD input 4 x thermocouple input 8 x thermocouple input 8 x SPST relay A 2x analogue output 4x analogue output 4 x universal input Slot C 4 x voltage input + 4 x current input 8 x voltage input + 8 x current input 6x voltage input, binary 6 x voltage input 6 x current input 4 x RTD input 4 x thermocouple input 8 x thermocouple input 8 x SPST relay A 4 x SPDT relay 5A 8 x SSR output 6 x SSR output 2x analogue output 4x analogue output 4 x universal input Supply 85 260 V AC/DC 6 35 V AC / 9 50 V DC D 6 U 6 I 6 D 6 U 6 I 6 R 8 I 0 2 I 0 4 D 6 U 6 I 6 R 8 R 4 5 S 0 8 S 6 I 0 2 I 0 4 Communication interface USB host port (back side) USB host port (front side) 2 2x USB host port 3 3x RS-485 / RS-232 2x USB host port x USB device 4 x Ethernet 0MB Display foil neutral customer 0 0 9 9 9 Special version standard customer 0 0 0 9 9 9 2 eet. Subject to change without notice. This price list contains product specification; properties are not guaranteed. Detailed information about options are defined in the datashe Paab Tekno Trading AB - Tingvallastrand 2, 66 40 Säffle, Sweden Tel: +46 533 50 60 - Fax +46 533 69 3 - info@paab.com - www.paab.com