PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

Similar documents
The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Tempco Instruction Manual

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

AIR COOLED MODULAR RECTIFIER

Table of Contents. Safety. Attention. Warnings

Service Instructions. Conductor 420

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

Installation, Operation and Maintenance Manual

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

AD-7830 Servo Amplifier

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

User's Guide. Extech AM A AC Analog Clamp Meter

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

TPE 1464 Series Pressure Transducer

Series RMT Hot Runner Controller Setup and Operation Manual

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

Differential Liquid/Gas Pressure Transmitter

VLT 2800 DRIVE SPECIFICATIONS

Series RMA Hot Runner Controller Setup and Operation Manual

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

700 Series 200 Amp Clamp Meters

PS8 - II. Professional Power Sequencer. User s Manual

Installation Instructions

User safety and equipment protection guidelines

This Datasheet for the IC660BBD101. Block 115Vac I/O Low Leakage 8 Circuits.

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

SP6R Level Controller Operation Manual

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

PowerFlex 40 Sample Specification

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

160 AA02SF1 AF DS-D17

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209

MODELS: STEAM FIRED YPC-ST-14SC & YPC-ST-16SL Thru YPC-ST-19S

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Electric Actuators and Control Systems. Established Leaders in Valve Actuation AD Instruction Manual. Publication P972E Issue 08/09

S82S (3/7.5-W Models)

V E1B Snap-in I/O Module

User's Guide. Phase Sequence and Motor Rotation Tester Model

PMDX-170 Slotted Optical Sensor

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

Magnetek Dynamic Braking Resistors

LDD M SERIES INSTRUCTION MANUAL LDD M SERIES

S66 Series Electronic Fan Speed Control

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

ELV12 Series. Instruction Manual

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Installation & Operation

V E1B Snap-in I/O Module

Model HM-535 Power Supply Installation and Service Instructions

Global Water globalw.com. Global Water. Instrumentation, Inc.

UPS READY POWER DISTRIBUTION ASSEMBLY

WS115 BREAKOUT ADAPTER USER MANUAL

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

Innovative Circuit Technology Ltd.

Analog Monitor Installation Manual

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

V E2B Snap-in I/O Module

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

LCI Load Cell Junction Box with Fault Monitor

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

PowerFlex 400 AC Drive Guide Specification

This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits.

Analog Input Installation Manual

This Datasheet for the IC660BBD022. Block 24Vdc Source I/O 16 Circuits, 2/3 Wire Sensor Compatible

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

1395 Node Adapter Board Troubleshooting

C-POWER AC AUTOMATIC CONTROL

User's Guide. Model High Precision Quad Output DC Power Supply

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Solid State Relays with Failure Detection Function

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

LCI User Manual mantracourt.com

REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution

Voltage Current Front-mounting bracket

DCM Digital Control Modules

INSTALLATION MANUAL SLI 50 INVERTER

Relays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

User s Guide. 600A AC Clamp Meter. Model 38387

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Broadband Automatic Disconnect Switch. User Manual

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

Transcription:

PHASETRONICS Specialists EP1 Series Power Control Single Phase SCR 10-50 Amps OPERATION & SERVICE MANUAL Phasetronics, Inc. P.O. Box 5988 1600 Sunshine Drive Clearwater, FL 33765 (727)573-1900 FAX(727)573-1803

Description The EP1 Series of Phase Angle s assures smooth proportional output power from 0 to 100%. This high quality SCR control is offered in single or a three phase version with a variety of options. These options include current limit, soft start current trip, voltage regulation and I 2 t fusing. The unit is ideally suited for all resistive and inductive or variable loads. The soft start feature assures a slow rising output voltage to prevent an inrush on inductive or variable resistance loads. The control input is adjustable to match all standard temperature and process controllers. The control signal sensitivity is adjustable by gain and offset potentiometers. The unit can be controlled from an external manual potentiometer. MOVs (standard) protect the SCRs from transient voltages. False firing (dv/dt) protection is standard. Receiving Upon receipt of this product you should immediately do the following: Inspect the unit for possible shipping damage. If damaged, notify the freight carrier and file a claim within 15 days of receipt. Verify the model number on the unit matches you purchase order. Verify that the unit is the correct current and voltage for your application. Warning! Do Not Service Equipment with voltage applied! Unit can be a source of fatal electrical shocks. To avoid shock hazard, disconnect main power before working on unit. - 1 -

Specifications Milliamp Input 4-20 ma Input Impedance - 250 ohms Inputs Analog Input 0-10 Vdc Signal / 0-5 Vdc Signal - 100k ohms input impedance Manual Control 10k ohm, 2 watt potentiometer, linear taper Output Current Rating 10 to 1000 Amps Output Stage Back to Back configuration AC Supply Voltage 120/208/240/308/415/480/575 Vac(+10% to -15%, 50/60 Hz) Type of Loads Resistive / Inductive / Lamp Soft Start Factory set for initial half-second of operation of power on. Field adjustable via potentiometer from 0.2 seconds to 30 seconds Hard Firing Gate Pulse A combination of a high-potential gate pulse and a rapid rise time is used to prevent SCR damage due t di/dt stress Input Gain 4-20mA, 0-5 Vdc, 0-10 Volts Adjustments Offset 50% of gain maximum Regulation (Option R) Optional feature to provide load avrage voltage regulation of plus or minus 2% for +10% to -10% of gain maximum Optional Fusing I2t fuse protects against short-circuit overloads (Option F) Protective Transient Voltage Suppressor Integral MOV (Metal Oxide Varistor) protects against high potential transient voltage Networks SCR Peak Inverse Voltage (PIV Rating) 2.5 times line rating (minimum) RC Snubber RC snubber networks prevent false firing due to dv/dt characteristics Ambient Temperature Operating range is from 0 C thru 40 C (30 F thru 122 F) Protective Networks Transient Voltage Suppressor (standard) - Integral MOV (Metal Oxide Varistor) protects against high potential voltage spikes. RC Snubber (Standard) - RC Snubber networks are used to prevent false firing due to dv/dt characteristics. SCR Peak Inverse Voltage (PIV Rating) Line Voltage: Continuous SCR Rating 120-480 1200 Volts 575 1500 Volts Ambient Temperature Ambient temperature operating range is 0 to 40 degrees C (32 to 122 F). Output rating decreases by 10% for each 5 degree C rise (9 F) in ambient temperature over 40 degrees C (122 F) to a max of 60 degrees C (140 F). Transportation and storage range is -30 to 65 degrees C (-30 to 149 F). - 2 -

Location Proper location of the EP1 Series is necessary to achieve specified performance and normal operation. The EP1 Series should always be installed in an area where the following conditions exist: Ambient operating temperature is 0 to 40 degrees C (32 to 104 F) Protected from rain and moisture Humidity range from 5% to 95% non-condensing Free from metallic particles, conductive dust and corrosive gas Free from excessive vibration (below 0.5G) Open panel units must be mounted in the appropriate type of enclosure. Enclosure size and type must be suitable to dissipate heat generated by the SCR power control. (NEMA 1 style enclosures can be vented to reduce size) Non-vented painted metal enclosures Non-vented stainless steel enclosures Formulas for sizing Units maximum current (FLA) x 1.5 = watts then watts / 10 = sq.ft. of exposed area ( ) FLA x 1.5 10 x 1.5 = sq.ft. of exposed area Warning! Do not service equipment with voltage applied! Unit can be source of fatal electrical shocks! To avoid shock hazard, remove all sources of power before working on controller. Warning labels must be attached to terminals, enclosure and control panel to meet local codes. Mounting and Cleaning If mounting the EP1 Series unit in an enclosure requires drilling or punching holes in the enclosure, cover the electrical assembly to protect unit from metal filings that could short out electronics. After work is complete, thoroughly clean the area and reinspect the EP1 Series. Make sure there is sufficient clearance (six inches) all around the EP1 Series unit for cooling. The unit must be installed with its heat sink ribs oriented vertically and running parallel to the mounting surface. Unit should be cleaned on a regular basis to insure proper cooling. Do not use any chemicals to clean the unit, use 80 to 100 psi clean dry compressed air only. A three inch high quality dry paint brush is helpful to loosen up the dust prior to using compressed air on the unit. - 3 -

Manual Control Connections If manual potentiometer is not used, proceed to Automatic Control Connections. Manual potentiometer does not have to be connected for unit to operate. Connect manual potentiometer to TB2-3(wiper), TB2-4(high) and TB2-6(low) per connection ( See Figure 1 for connections & Figure 2 for locations). Figure 1 - Manual Connections Automatic Control Connections Connect DC voltage or milliamp input signal to pins 1(positive) and 2(negative) on TB2. You must select the proper jumper for 4-20 ma*, 0-5 Vdc or 0-10 Vdc. (See location of jumpers and pins Figure 2) * 0-10 Vdc connection jumper X4 installed 4-20 ma connection jumper X2 installed (factory setting) 0-5 Vdc connection jumper X3 installed Figure 2 - TB2 Connections If manual and automatic control are both used, consider using an external auto/manual switch to stop the manual setting from overriding the automatic signal. - 4 -

Power Connections Make line 1 connection to L1 and Load connection to T1. (See Figure 3) If option card is not used connect L2 (using 18-22 gauge wire) to terminal 6 on TB1(EPCL1000). (See Figure 3) If option card is used, connect L2 to terminal 7 of TB2 on option card. (See Figure 4) L1 (Hot) T1 (To Load) L2 connection (if no option card is present) Figure 3 - Power Connection (no option card) Option Card (mounted on main logic board when options are ordered) L2 Connected to TB2-7 on option card Figure 4 - Power Connection (with option card) Soft Start (Standard) Soft start ramp adjustment is factory set (P3) for 0.5 seconds. The soft start ramp time can be increased to a maximum of 30 seconds by adjusting P3 in a clockwise(cw) direction. Note: Soft start is active only when initial power is applied and a command signal is present. It has no effect on control signal change. (See Option S on page 6 if soft start is required on restart of ma signal or when lockout is released.) - 5 -

Options The following options are available on the EP1 Series but must be specified when ordering. When options are ordered a separate option card is mounted on top of the main logic board. Soft Start (Option S ) Provides soft start on a signal change or when lockout is released. This will help protect fuses. The unit is set up so that either of these two soft start modes can be disabled by removing X1 & X2 on option card (See figure 5 below or Option board page 8). The unit will ramp up on a signal change if this signal is set below a threshold level. The threshold is adjustable from 0 to 30 seconds of control signal range. Current Limit (Option C ) Provides flexibility for changing loads, helps protect unit. Adjustable from 10-110% of unit rating. Current limit will override control input signal to limit the output current. Current transformer included. To disable remove X1 & X3 on option card. (See figure 5 below or Option board page 8) Current Trip (Option T ) Used as a protective measure. This option will shut down unit when the current exceeds an adjusted preset level. Adjustable from 75-200% for instantaneous trip if current exceeds set level. Unit can be connected for manual reset. Current transformer included. To disable remove X4. (See figure 5 below or Option board page 8) Line Voltage Regulation (Option R ) Provides more accurate linearity. Will maintain output within 2% with a +/- 10% line variation. Note: The number of potentiometers on the option card will vary depending on the options ordered. Option Card (mounted on main logic board) Figure 5 - Option setting locations - 6 -

Main Logic Board (EP1 Series - 10-50 Amp) L2 Connection (used when no option card is present) - 7 -

EP1 Series Option Board This board is mounted on main logicboard when options are ordered. L2 Connection - 8 -

Warranty Policy Motortronics warrants its products to be free from defects in material and/or workmanship for a period of one year from date of installation, to a maximum of 18 months from the date of shipment as indicated by the unit s date code. The Company reserves the right to repair or replace any malfunctioning units under warranty at their option. All warranty repairs must be performed by the Company factory, or on site by a factory authorized service firms or personnel approved by the Company. Solid state controls have different operation characteristics from those of electro-mechanical equipment. Because of these differences and the wide variety of applications for solid state controls, each application designer must verify that the solid state equipment is acceptable for his application. In no event will Motortronics be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The diagrams and illustrations in this document are included solely for illustrative purposes. Because of the number of different applications, Motortronics can not be responsible or liable for actual use based on the examples or diagrams. - 9 -