warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

Similar documents
4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

DA502 Digital/Analog Input/Output Module

DC541 Digital Input/Output Module

DA502 Digital/Analog Input/Output Module

DA502 Digital/Analog Input/Output Module

CI542 PROFIBUS Communication Interface Module

CI521 Modbus Communication Interface Module

DC562, digital input/output module,

CI541 PROFIBUS Communication Interface Module

DC522 Digital Input/Output Module

DC532-XC, digital input/output module,

DX561 Digital Input/Output Module

AX522 Analog Input/Output Module

CD522 Encoder, Counter and PWM Module

DC561, digital input/output module,

Freelance 800F packed with new features! Coming soon

AX521 Analog Input/Output Module

AI531 Analog Input Module

AI561 Analog Input Module

AO561 Analog Output Module

AO523 Analog Input Module

CI501 PROFINET Communication Interface Module

DI561 Digital Input Module

DI572 Digital Input Module

TU531, TU532 Terminal Unit

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

CI504 PROFINET Communication Interface Module

PM572, PM573, PM582, PM583, PM585, PM590, PM591, PM592

TF501, TF521 Terminal Bases

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Control IT AC 800C Controller

PM572, PM573, PM582, PM583, PM585, PM590, PM591, PM592

Part Number Total I/O Power Voltage Input Voltage Output Type Maximum Digital I/O Maximum Analog I/O V AC Relay 24V DC.

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage

Power Panel Integrated control, operation and visualization

General information. Display. Supply voltage

TECHNICAL DOCUMENTATION

General information. Display. Supply voltage

CM597 Ethernet Communication Module

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TM221M16TG controller M IO transistor PNP spring

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

TM221ME32TK controller M IO transistor PNP Ethernet

TM221CE40T controller M IO transistor PNP Ethernet

CM579-PNIO PROFINET Communication Module

TM238LFAC24DR compact base M I/O V AC supply - CANOpen- internal RAM 1000 kb

CM592 PROFIBUS Communication Module

General information. Display. Supply voltage. Input current

TM221M32TK controller M IO transistor PNP

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Assortment Insertion / replacement of the Lithium battery Insertion of the SD Memory Card

General information Engineering with Programming package. Display with display

CM589 PROFINET Communication Module

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

TM241C40U controller M IO transistor NPN

Data sheet VIPA CPU 115DP (115-6BL22)

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

QUINT-PS AC/24DC/10

TM241C24T controller M IO transistor PNP

mxcontrol Multifunction Controller

General information. Display. Supply voltage. Input current. Encoder supply. Output current

CM589 PROFINET Communication Module

TM221ME16T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

General information. Display. Supply voltage. Input current

Data sheet CPU 115 (115-6BL02)

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

TM221CE24R controller M IO relay Ethernet

General information. Display. Supply voltage. Input current

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

Select a Micro800 Controller

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

TM221M16R controller M IO relay

General information. Display. Supply voltage. Input current

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Power supply CP-C 24/5.0

PHOENIX CONTACT Features

Supply voltage. Input current. Encoder supply. Memory

QUINT-PS/ 1AC/24DC/ 5

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Power Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41

TWDLMDA20DRT extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state and relay

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

TWDLMDA40DUK extendable PLC base Twido 24 V - 24 I 24 V DC - 16 O solid state

TM221CE24T controller M IO transistor PNP Ethernet

RSTI-EP Slice I/O. Digital Output Module

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Transcription:

System Freelance 800F AC 700F Module Description Data Sheet Central Processing Unit PM 783F Detailed data of the CPU (PM 783F) CPU Processor Program memory (Battery backed up) Internal memory Typical cycle time for 1000 instructions - Binary - Word - Floating point PM 783F Motorola Power PC (MPC8247) 2 MB SRAM 8 MB SDRAM, 4 MB FLASH ROM 1.667 ms 2.322 ms 3.1250 ms Max. number of I/O Modules 8 Data backup source Lithium Battery Data buffering time at 25 C/ 77 F Approximately 1.5 years Battery low indication warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes Multitasking Program execution - cyclic (Equidistant) - cyclic (As fast as possible) - Event driven (Upon any of these events->) Serial interface SER (COM1) - Physical link: - Connection: - Usage: Serial interface DIAG (COM2) - Physical link: - Connection: - Usage: Onboard network interface LEDs, LCD display, 8 function keys Certifi cations 8 Tasks 1 Task Run, Stop, Warm start, Cold start, Error - RS-232 or RS-485 (from 1200 bps to 38400 bps) - pluggable terminal block, spring connection - as Modbus ASCII/ RTU (Master/Slave), - RS-232 - SUB-D Female connector - for programming/ diagnostics 1 x Ethernet (RJ45) for RUN/STOP switch-over, status displays and diagnosis CE, GL, cul

Central Processing Unit PM 783F General data of the CPU (PM 783F) Current consumption from 24 V DC Inrush current at 24 V DC Max. power dissipation within the Dimensions Width x height x depth (CPU without the Terminal Base) Weight (CPU without Terminal Base) 80 ma (Max) 1 A 2 s 10 W 67.5 x 76 x 54 mm / 2.66 x 2.99 x 2.13 inches 150 g / 5.29 oz. horizontal or vertical with de-rating (50 % output load, reduction of maximum temperature to 40 C/ 104 F) Analog Input Module AI 723F Functionality Functionality AI 723F: 16 analog inputs, unused (default setting) 0...10 V -10 V...+10 V AI 723F: 16 analog inputs, 0...20 ma 4...20 ma Pt100, -50 C (-58 F)...+400 C (+752 F) Pt100, -50 C (-58 F)...+400 C (+752 F) Pt100, -50 C (-58 F)...+70 C (+158 F) Pt100, -50 C (-58 F)...+70 C (+158 F) Pt1000, -50 C (-58 F)...+400 C (+752 F) Pt1000, -50 C (-58 F)...+400 C (+752 F) LED displays Internal power supply External power supply 0...10 V with differential inputs, requires 2 channels -10 V...+10 V with differential inputs, requires 2 channels digital signals (digital input) Process voltage - Rated value 24 V DC - max. ripple 5 % - Protection against reversed yes voltage 19 LEDs for signals and error messages through the expansion bus interface (I/O-Bus) via the terminals ZP and UP (process voltage 24 V DC) 2

Rated protection fuse on UP 10 A fast - Electrical isolation yes, per - Current consumption from UP 0.15 A at normal operation - Inrush current from UP (at power up) 0.050 A²s - Connections Terminals 1.8-4.8 for +24 V (UP) and 1.9-4.9 for 0 V (ZP) Max. length of analog cables, conductor cross section > 0.14 mm² (~26 AWG) Conversion error of the analog values caused by nonlinearity, adjustment error at factory and resolution within the normal range Width x height x depth (without the Terminal Unit) Weight Cooling 100 m / 328 ft. typ. 0.5 %, max. 1 % 67.5 x 76 x 54 mm / 2.66 x 2.99 x 2.13 inches of the analog inputs Distribution of channels into 300 g / 10.52 oz horizontal or vertical with derating (output load reduced to 50 % at 40 C/ 104 F per group) The natural convection cooling must not be hindered by cable ducts or other parts in the mounting cabinet. 16 2 of 8 channels each of the analog inputs Resolution Unused voltage inputs Unused current inputs Overvoltage protection Range 0...10 V: 12 bits Range -10...+10 V: 12 bits + sign Range 0...20 ma: 12 bits Range 4...20 ma: 12 bits Temperature: 0.1 C / 0.18 F are confi gured as unused have a low resistance, can be left open-circuited yes of the analog inputs, if they are used as digital inputs Distribution of channels into I0+ to I7+ I8+ to I15+ Reference potential for the inputs Input signal delay Input signal voltage Signal 0 Signal 1 max. 16 2 of 8 channels each Terminals 2.0 to 2.7 Terminals 4.0 to 4.7 Terminals 1.8 to 4.8 (ZP) typ. 8 ms 24 V DC -30 V...+5 V +13 V...+30 V I0- to I7- I0+ to I7+ I8- to I15- I8+ to I15+ Electrical isolation Confi gurability Channel input resistance Time constant of the input fi lte r Terminals 1.0 to 1.7 Terminals 2.0 to 2.7 Terminals 3.0 to 3.7 Terminals 4.0 to 4.7 against internal supply and other s 0...10 V, -10...+10 V, 0/4...20 ma, Pt100/1000, Ni1000 (each input can be confi gured ) Voltage: > 100 kω, current: ca. 330 Ω Voltage: 100 µs, current: 100 µs 3

Analog Input/Output Module AX 722F Functionality AX 722F: 8 analog inputs, 4 analog outputs, unused (default setting) 0...10 V -10 V...+10 V 0...20 ma 4...20 ma Pt100, -50 C (-58 F)...+400 C (+752 F) Pt100, -50 C (-58 F)...+400 C (+752 F) Pt100, -50 C (-58 F)...+70 C (+158 F) Pt100, -50 C (-58 F)...+70 C (+158 F) Pt1000, -50 C (-58 F)...+400 C (+752 F) Pt1000, -50 C (-58 F)...+400 C (+752 F) 0...10 V with differential inputs, requires 2 channels -10 V...+10 V with differential inputs, requires 2 channels digital signals (digital input) unused (default setting) -10 V...+10 V 0...20 ma 4...20 ma LED displays Internal power supply External power supply Process voltage - Rated value 24 V DC - max. ripple 5 % - Protection against reversed yes voltage 19 LEDs for signals and error messages through the expansion bus interface (I/O-Bus) via the terminals ZP and UP (process voltage 24 V DC) - Rated protection fuse on UP 10 A fast - Electrical isolation yes, per - Current consumption from UP 0.10 A output loads at normal operation - Inrush current from UP (at power up) 0.020 A²s - Connections Terminals 1.8-4.8 for +24 V (UP) and 1.9-4.9 for 0 V (ZP) Max. length of analog cables, conductor cross section > 0.14 mm² (~26 AWG) Conversion error of the analog values caused by non-linearity, adjustment error at factory and resolution within the normal range Width x height x depth (without the Terminal Unit) Weight 100 m / 328 ft. typ. 0.5 %, max. 1 % 67.5 x 76 x 54 mm / 2.66 x 2.99 x 2.13 inches 300 g / 10.58 oz. horizontal or vertical with derating (output load reduced to 50 % at 40 C/ 104 F per group) 4 analog outputs, unused (default setting) -10 V...+10 V Cooling The natural convection cooling must not be hindered by cable ducts or other parts in the mounting cabinet. 4

of the analog inputs 8 of the analog outputs Number of channels per 8, all channels for voltage, the fi rst 4 channels also for current Distribution of the channels into 1 group of 8 channels Distribution of channels into 1 group of 8 channels I0- to I7- I0+ to I7+ Electrical isolation Confi gurability Channel input resistance Time constant of the input fi lte r Conversion cycle Resolution Unused voltage inputs Unused current inputs Terminals 1.0 to 1.7 Terminals 2.0 to 2.7 against internal supply and other s 0...10 V, -10...+10 V, 0/4...20 ma, Pt100/1000, Ni1000 (each input can be confi gured ) Voltage: > 100 kω, current: ca. 330 Ω Voltage: 100 µs, current: 100 µs 2 ms (for 8 inputs + 8 outputs), with Pt/Ni... 1 s Range 0...10 V: 12 bits Range -10...+10 V: 12 bits + sign Range 0...20 ma: 12 bits Range 4...20 ma: 12 bits Temperature : 0.1 C / 0.18 F are confi gured as unused have a low resistance, can be left open-circuited - Channels O0-...O7- Terminals 3.0...3.7 - Channels O0+...O7+ Terminals 4.0...4.7 Output type bipolar with voltage, unipolar with current Electrical isolation against internal supply and other s Confi gurability -10...+10 V, 0...20 ma, 4...20 ma (each output can be confi gured ), current outputs only channels 0...3 Output resistance 0...500 Ω (load), as current output Output loadability, as voltage output Indication of the output signals Resolution Unused outputs max. ±10 ma 12 bits (+ sign) can be left open-circuited Overvoltage protection yes of the analog inputs, if they are used as digital inputs Max. 8 Distribution of channels into I0+ to I7+ Reference potential for the inputs Input signal delay Input signal voltage Signal 0 Signal 1 1 group of 8 channels Terminals 2.0 to 2.7 Terminals 1.8 to 4.8 (ZP) typ. 8 ms 24 V DC -30 V...+5 V +13 V...+30 V 5

Digital Input/Output Module DC 732F Functionality Digital inputs Digital inputs/outputs (Confi gurable) 16 (24 V DC) 16 (24 V DC) of the digital inputs 16 Distribution of the channels into 1 group of 16 channels High-speed counter LED displays Internal power supply External power supply Not Available for signal statuses, errors and supply voltage through the expansion bus interface (I/O-Bus) via the terminals ZP and UP (process voltage 24 V DC) Process supply voltage UP - Connections Terminals 1.8-4.8 for +24 V (UP) and 1.9-4.9 for 0 V (ZP) - Rated value 24 V DC - max. ripple 5 % - Protection against reversed yes voltage - Rated protection fuse on UP 10 A fast - Electrical isolation yes, per Current consumption - internal (via I/O-Bus) ca. 5 ma at 3.3 V DC - current consumption from UP at normal operation / with outputs - inrush current from UP (at power up) Max. power dissipation within the Width x height x depth (without the Terminal Unit) Weight (without Terminal Unit) Cooling 0.05 A + max. 0.008 A per input + max. 0.5 A per output 0.007 A²s 6 W (outputs unloaded) 67.5 x 76 x 54 mm / 2.66 x 2.99 x 2.13 inches Approx. 125 g / 4.41 Oz. horizontal or vertical with derating (output load reduced to 50 % at 40 C/ 104 F per group) The natural convection cooling must not be hindered by cable ducts or other parts in the mounting cabinet. Terminals of the channels I0 to I7 Terminals of the channels I8 to I15 Reference potential for all inputs Electrical isolation 1.0 to 1.7 2.0 to 2.7 terminals 1.9...4.9 (minus pole of the process supply voltage, signal name ZP) from the rest of the (I/O-Bus) one yellow LED per channel, the LED is ON when the input signal is high (signal 1) Input type acc. to EN 61131-2 Type 1 Input delay (0->1 or 1->0) typ. 8 ms, confi gurable from 0.1 to 32 ms Input signal voltage signal 0 undefi ned signal signal 1 Ripple with signal 0 Ripple with signal 1 Input current per channel input voltage +24 V input voltage +5 V input voltage +15 V input voltage +30 V Max. cable length shielded unshielded 24 V DC -3 V...+5 V > +5 V...< +15 V +15 V...+30 V within -3 V...+5 V within +15 V...+30 V typ. 5 ma > 1 ma > 5 ma < 8 ma 1000 m / 3280 ft. 600 m / 1968 ft. of the configurable digital inputs/outputs Each of the confi gurable I/O channels can be wired as input or output by the user. Distribution of the channels into 16 inputs/outputs (with transistors) 1 group of 16 channels if the channels are used as inputs - channels I16...I23 terminals 3.0...3.7 - channels I24...I31 terminals 4.0...4.7 6

of the configurable digital inputs/outputs if the channels are used as outputs - channels Q16...Q23 terminals 3.0...3.7 - channels Q24...Q31 terminals 4.0...4.7 Indication of the input/output signals Electrical isolation one yellow LED per channel, the LED is ON when the input/output signal is high (signal 1) from the rest of the of the digital inputs/outputs if used as outputs Reference potential for all outputs Common power supply voltage Output voltage for signal 1 Output delay (0->1 or 1->0) Output current rated value, per channel maximum value (all channels together) Leakage current with signal 0 Rated protection fuse on UP De-magnitization when inductive loads are switched off Switching frequency with resistive load with inductive loads with lamp loads Short-circuit proof / overload proof max. 16 transistor outputs terminals 1.9...4.9 (minus pole of the process supply voltage, signal name ZP) for all outputs: terminals 1.8...4.8 (plus pole of the process supply voltage, signal name UP) UP -0.8 V on request 500 ma at UP = 24 V 8 A < 0.5 ma 10 A fast with varistors integrated in the on request max. 0.5 Hz max. 11 Hz with max. 5 W yes of the digital inputs/outputs if used as outputs Overload message (I > 0.7 A) Output current limitation Resistance to feedback against 24V signals Max. cable length shielded unshielded yes, after ca. 100 ms yes, automatic reactivation after short-circuit/overload yes 1000 m / 3280 ft. 600 m / 1968 ft. of the digital inputs/outputs if used as inputs Reference potential for all inputs Input current, per channel max. 16 digital inputs terminals 1.9...4.9 (minus pole of the process supply voltage, signal name ZP) see Technical Data of Digital inputs Input type acc. to EN 61131-2 Type 1 Input delay (0->1 or 1->0) typ. 8 ms, confi gurable from 0.1 to 32 ms Input signal voltage 24 V DC Signal 0-3 V...+5 V * undefi ned signal > +5 V...< +15 V Signal 1 +15 V...+30 V Ripple with signal 0 within -3 V...+5 V * Ripple with signal 1 within +15 V...+30 V Max. cable length shielded 1000 m / 3280 ft. unshielded 600 m / 1968 ft. * Due to the direct connection to the output, the demagnetizing varistor is also effective at the input. This is why the difference between UPx and the input signal may not exceed the clamp voltage of the varistor. The varistor limits the voltage to approx. 36 V. Following this, the input voltage must range from - 12 V to + 30 V when UPx = 24 V and from - 6 V to + 30 V when UPx = 30 V. Terminal Base TB 711F (for the CPU PM 783F) Connection of the 24 V DC process voltage with a 5-pole removable terminal block Slots 1 CPU, 1 Communication (Not Used Currently) Interfaces Field I/O -> 1 [I/O-Bus] Serial Ports-> 2 [ SER (COM1) and DIAG (COM2)] Networking -> 1 [Ethernet (RJ45)] Dimensions Width x height x depth (with CPU inserted) 95.5 x 135 x 75 mm / 3.75 x 5.31 x 2.95 inches 7

Dummy Coupler Module TA 724F Use Mounting Weight Dimensions to protect the unused coupler slot from dust and touch On CPU Terminal Base TB 711F 50 g / 1.76 oz. 135 mm x 28 mm x 62 mm / 5.31 x 1.1 x 2.44 inches I/O Terminal Unit TU 715F (24 V DC, Screw-type Terminals) 32 Distribution of the channels into Rated voltage Max. permitted total current Earthing Screw-type terminals Type abb 4 of 8 channels each (1.0...1.7, 2.0...2.7, 3.0...3.7, 4.0...4.7), the allocation of the channels is given by the inserted I/O expansion 24 V DC 10 A (between the terminals 1.8...4.8 and 1.9...4.9) direct connection to the earthed DIN rail or via the screws with wall mounting Front terminal, conductor connection vertically with respect to the printed circuit board Conductor cross section - solid 0.08 mm² to 2.5 mm² (28 AWG to 13 AWG) - fl exible 0.08 mm² to 2.5 mm² (28 AWG to 13 AWG) - with wire-end ferrule 0.25 mm² to 1.5 mm² (23 AWG to 15 AWG) Stripped conductor end 8 mm (0.31 inches) Width of the screwdriver 3.5 mm (0.14 inches) Fastening torque 0.6 Nm (5.3 Pound Inch) Degree of protection IP 20 Dimensions Width x height x depth 67.5 x 135 x 30 mm / 2.66 x 5.31 x 1.18 inches Weight 200 g / 7.05 oz. horizontal or vertical For the latest information on ABB visit us on the World Wide Web at http://www.abb.com ABB Process Automation Division Mannheim, Germany Phone: +49 (0) 1805 266776 Fax: +49 (0) 1805 776329 www.abb.de/controlsystems e-mail: Marketing.Control-Products@de.abb.com ABB Process Automation Division Västerås, Sweden Phone: +46 (0) 21 34 20 00 Fax: +46 (0) 21 13 78 45 www.abb.com/controlsystems e-mail: processautomation@se.abb.com ABB Process Automation Division Wickliffe, Ohio, USA Phone: +1 440 585 8500 Fax: +1 440 585 8756 www.abb.com/controlsystems e-mail: industrialitsolutions@us.abb.com ABB Process Automation Division Singapore Phone: +65 6776 5711 Fax: +65 6778 0222 www.abb.com/controlsystems e-mail: processautomation@sg.abb.com 3BDD015167 en 07.2008 Copyright 2008 ABB. All rights reserved. The term Industrial IT and all product names mentioned above in the form xxxxxx IT are registered or requested trademarks of ABB. Microsoft and Windows are registered trademarks of Microsoft Corp. Pictures, schematics, and other graphics contained herein are published for illustration purposes only and do not represent product confi gurations or functionality. User documentation accompanying the product is the exclusive source for functionality descriptions.