GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

Similar documents
GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

NI crio-9101/9102/9103/9104

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

Electromagnetic Compatibility Guidelines

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

Electrical. SPECIFICATIONS SH Cable

NI Safety Guidelines. Safety Guidelines for Hazardous Locations GETTING STARTED GUIDE. Ethernet Expansion Chassis for C Series Modules

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules. This document describes how to begin using the NI crio-9064.

24-Channel, ±24 V Precision PXI Source Measure Unit

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, Sinking Digital Input/Sourcing Digital Output Module. ni.

12-Channel, ±24 V Precision PXI Source Measure Unit

NI R Series. Contents. Software CALIBRATION PROCEDURE

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

SH Cable Specifications

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Stepper Drive. ni.com/manuals

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

NI PXIe Contents GETTING STARTED GUIDE. RF Preselector Module

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

NI SD Card Memory Module

NI PXI Contents GETTING STARTED GUIDE. 8 GHz RF Amplifier

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

NI PXIe-4080/4081/4082

NI ELVIS RIO Control Module

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

GETTING STARTED GUIDE NI Port, RS232 Serial Module. Français Deutsch 日本語한국어简体中文. ni.com/manuals

NI 9503 Stepper Drive

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

GETTING STARTED GUIDE NI Port, RS485/RS422 Serial Module. Français Deutsch 日本語한국어简体中文. ni.com/manuals

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

Electromagnetic Compatibility Guidelines

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

To access NI 5622 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI CMS-9068 and NI MMS-9068

NI 9472 DATASHEET. 8 DO, 6 V to 30 V, Sourcing, 100 μs

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

Single-Channel Precision System Source Measure Unit (SMU)

Bracket and Mounting Dimensions

NI 6521 Specifications

You need the following to set up and use your terminal block:

NI SMD-7610 Stepper Drives and NI 9512 C Series Modules

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

GETTING STARTED GUIDE NI Synchronization Module

Contents. CALIBRATION PROCEDURE NI PXIe-5624R 2 GS/s, 12-Bit IF Digitizer

NI PXI-2567 Specifications

NI 9375 DATASHEET. 16 DI/16 DO, 30 VDC, 7 μs Sinking DI, 500 μs Sourcing DO

CALIBRATION PROCEDURE CAL Contents. Software

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

Safety and Radio-Frequency Interference

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

Thermal Kit for NI sbrio-9607/9627/9637

USER GUIDE USB-634x/635x/636x OEM X Series USB-6341/6343/6356/6361/6363/6366 OEM Devices

NI PXI/PXIe/PCI Contents GETTING STARTED GUIDE. 14-Bit, 100 MS/s PXI Oscilloscope

SCC-AO10 Isolated Analog Output Module

SCC-RLY01 Relay Module

PXI/PCI Contents GETTING STARTED GUIDE. 2 GS/s Oscilloscope

GETTING STARTED NI SMD-7611/7612 Stepper Drives and NI 9512 C Series Modules

36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module. DSUB are referred to inclusively as the NI 9476.

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

Embedded Direct Injector Control and Measurement (DCM) Device with Real-Time Processor and Reconfigurable FPGA

Introduction... 1 System Diagram... 2 Hardware... 2 Powering the Hardware... 3 Wiring Harness... 5

Contents. Software CALIBRATION PROCEDURE NI TC-4353

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

Figure 1. NI-7935R. Related Information For information about the device specifications, refer to the NI-7935R Specifications at ni.com/manuals.

C SERIES DIGITAL INPUT/OUTPUT MODULE COMPARISON

Transcription:

GETTING STARTED GUIDE NI 9219 100 S/s/channel, 4-Channel C Series Universal Analog Input Module

This document explains how to connect to the NI 9219. Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. Note The guidelines in this document are specific to the NI 9219. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system. Safety Guidelines Operate the NI 9219 only as described in this document. Caution This icon denotes a caution, which advises you to consult documentation where this symbol is marked. Caution Do not operate the NI 9219 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection 2 ni.com NI 9219 Getting Started Guide

built into the product if the product is damaged in any way. If the product is damaged, return it to NI for repair. Hazardous Voltage This icon denotes a warning advising you to take precautions to avoid electrical shock. Safety Guidelines for Hazardous Voltages If hazardous voltages are connected to the device, take the following precautions. A hazardous voltage is a voltage greater than 42.4 V pk voltage or 60 V DC to earth ground. Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards. Caution Do not mix hazardous voltage circuits and human-accessible circuits on the same module. Caution Ensure that devices and circuits connected to the module are properly insulated from human contact. Caution When terminals are hazardous live, you must ensure that devices and circuits connected to the NI 9219 Getting Started Guide National Instruments 3

module are properly insulated from human contact. You must use the NI 9972 backshell kit to ensure that the terminals are not accessible. Safety Voltages Connect only voltages that are within the following limits. Isolation Channel-to-channel Continuous Withstand Channel-to-earth ground Continuous Withstand 250 V AC, Measurement Category II 1,500 V AC, verified by a 5 s dielectric withstand test 250 V AC, Measurement Category II 3,000 V AC, verified by a 5 s dielectric withstand test 4 ni.com NI 9219 Getting Started Guide

Zone 2 hazardous locations applications Channel-tochannel and channel-to-earth ground 60 V DC, Measurement Category I Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are for other circuits not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as NI 9219 Getting Started Guide National Instruments 5

that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe. Caution When using the NI 9219 above 2,000 m or in explosive atmospheres, do not connect to signals or use for measurements within Measurement Categories II, III, or IV. Caution Do not connect the NI 9219 to signals or use for measurements within Measurement Categories III or IV. Safety Guidelines for Hazardous Locations The NI 9219 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx na IIC T4 Gc and Ex na IIC T4 Gc hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI 9219 in a potentially explosive environment. Not following these guidelines may result in serious injury or death. Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous. 6 ni.com NI 9219 Getting Started Guide

Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous. Caution Substitution of components may impair suitability for Class I, Division 2, or Zone 2. Caution The system must be installed in an enclosure certified for the intended hazardous (classified) location, having a tool secured cover/door, where a minimum protection of at least IP54 is provided. Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9219 has been evaluated as Ex na IIC T4 Gc equipment under DEMKO 07 ATEX 0626664X and is IECEx UL 14.0089X certified. Each NI 9219 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 C Ta 70 C. If you are using the NI 9219 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nc IIC T4, Ex IIC T4, Ex na IIC T4, or Ex nl IIC T4 equipment. NI 9219 Getting Started Guide National Instruments 7

Caution Transient protection shall be provided that is set at a level not exceeding 140% of the peak rated voltage value of 85 V at the supply terminals to the equipment. Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC/EN 60664-1. Caution The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15. Caution The enclosure must have a door or cover accessible only by the use of a tool. Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference 8 ni.com NI 9219 Getting Started Guide

when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Special Conditions for Marine Applications Some products are Lloyd s Register (LR) Type Approved for marine (shipboard) applications. To verify Lloyd s Register certification for a product, visit ni.com/certification and search NI 9219 Getting Started Guide National Instruments 9

for the LR certificate, or look for the Lloyd s Register mark on the product. Notice In order to meet the EMC requirements for marine applications, install the product in a shielded enclosure with shielded and/or filtered power and input/output ports. In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. Preparing the Environment Ensure that the environment in which you are using the NI 9219 meets the following specifications. Operating temperature -40 C to 70 C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity (IEC 60068-2-78) Pollution Degree 2 Maximum altitude 10% RH to 90% RH, noncondensing 2,000 m 10 ni.com NI 9219 Getting Started Guide

Indoor use only. Note Refer to the device datasheet on ni.com/manuals for complete specifications. NI 9219 Getting Started Guide National Instruments 11

NI 9219 Pinout CH0 1 4 2 5 3 6 CH1 1 4 2 5 3 6 CH2 1 4 2 5 3 6 CH3 1 4 2 5 3 6 12 ni.com NI 9219 Getting Started Guide

Table 1. Signals by Mode Mode Pin 1 2 3 4 5 6 Voltage T+ T- HI LO Current T+ T- HI LO 4-Wire Resistance T+ T- EX+ HI EX- LO 2-Wire Resistance T+ T- HI LO Thermocouple T+ T- HI LO 4-Wire RTD T+ T- EX+ HI EX- LO 3-Wire RTD T+ T- EX+ EX- LO Quarter-Bridge T+ T- HI LO Half-Bridge T+ T- EX+ HI EX- Full-Bridge T+ T- EX+ HI EX- LO NI 9219 Getting Started Guide National Instruments 13

Table 1. Signals by Mode (Continued) Mode Pin 1 2 3 4 5 6 DI T+ T- HI LO Open Contact T+ T- HI LO Table 2. Signal Descriptions Signal EX+ EX- HI LO Description Positive sensor excitation connection Negative sensor excitation connection Positive input signal connection Negative input signal connection T+ TEDS data connection T- TEDS COM connection 14 ni.com NI 9219 Getting Started Guide

Measurement Types The NI 9219 provides modes for the following measurement types. Voltage Current 4-Wire Resistance 2-Wire Resistance Thermocouple 4-Wire RTD 3-Wire RTD Quarter-Bridge Half-Bridge Full-Bridge Digital In 1 Open Contact 1 1 Only supported in CompactRIO systems. NI 9219 Getting Started Guide National Instruments 15

Voltage Connections HI + LO NI 9219 Related Information Voltage Pinout on page 30 16 ni.com NI 9219 Getting Started Guide

Current Connections HI LO NI 9219 Related Information Current Pinout on page 30 NI 9219 Getting Started Guide National Instruments 17

Thermocouple Connections HI Thermocouple LO NI 9219 Changes in the ambient air temperature near the front connector or a thermocouple wire conducting heat directly to terminal junctions can cause thermal gradients. Observe the following guidelines to minimize thermal gradients and improve the system accuracy. Use small-gauge thermocouple wire. Smaller wire transfers less heat to or from the terminal junction. Avoid running thermocouple wires near hot or cold objects. Minimize adjacent heat sources and air flow across the terminals. Keep the ambient temperature as stable as possible. 18 ni.com NI 9219 Getting Started Guide

Make sure the NI 9219 terminals are facing forward or upward. Keep the NI 9219 in a stable and consistent orientation. Allow the thermal gradients to settle after a change in system power or in ambient temperature. A change in system power can happen when the system powers on, the system comes out of sleep mode, or you insert/remove modules. Related Information Thermocouple Pinout on page 31 NI 9219 Getting Started Guide National Instruments 19

4-Wire Resistance and 4-Wire RTD Connections RTD/ Resistor Rwire Rwire Rwire EX+ HI LO Rwire EX- NI 9219 Related Information 4-Wire Resistance and 4-Wire RTD Pinout on page 31 20 ni.com NI 9219 Getting Started Guide

3-Wire RTD Connections Rwire EX+ RTD Rwire LO Rwire EX- NI 9219 Related Information 3-Wire RTD Pinout on page 32 NI 9219 Getting Started Guide National Instruments 21

Full-Bridge Connections Rwire EX+ R1 R4 HI LO R2 R3 Rwire EX- NI 9219 Related Information Full-Bridge Pinout on page 32 22 ni.com NI 9219 Getting Started Guide

Half-Bridge Connections Rwire EX+ R1 HI R2 Rwire EX- NI 9219 Related Information Half-Bridge Pinout on page 33 NI 9219 Getting Started Guide National Instruments 23

Digital In Connections HI + LO NI 9219 The digital in measurement type is only supported in CompactRIO systems. Tip Visit ni.com/info and enter the Info Code 9219cdaq for information about implementing the digital in measurement type in CompactDAQ systems. Related Information Digital In Pinout on page 33 24 ni.com NI 9219 Getting Started Guide

Open Contact Connections HI LO NI 9219 The open contact measurement type is only supported in CompactRIO systems. Tip Visit ni.com/info and enter the Info Code 9219cdaq for information about implementing the open contact measurement type in CompactDAQ systems. Related Information Open Contact Pinout on page 34 NI 9219 Getting Started Guide National Instruments 25

TEDS Connections Data T+ COM T- TEDS Enabled Sensor NI 9219 For more information about TEDS, visit ni.com/info and enter the Info Code rdteds. NI 9219 Connection Guidelines Make sure that devices you connect to the NI 9219 are compatible with the module specifications. Open the terminal by pressing the push button when using stranded wire without a ferrule. Push the wire into the terminal when using a solid wire or a stranded wire with a ferrule. Use shielded cables and twisted pair wiring for the best signal quality. 26 ni.com NI 9219 Getting Started Guide

NI recommends using the NI 9972 backshell for all connections to the NI 9219. You can connect ground-referenced signal sources to the NI 9219. The following figure illustrates a grounded connection for a voltage source. + Shield HI LO Signal Source NI 9219 You can connect floating signal sources to the NI 9219. Ensure that the voltages on the HI and LO connections are within the channel-to-earth working voltage range. The following figure illustrates a floating connection for a voltage source. NI 9219 Getting Started Guide National Instruments 27

+ Shield HI LO Signal Source NI 9219 High-Vibration Application Connections If your application is subject to high vibration, NI recommends that you use the NI 9972 backshell kit to protect connections to the NI 9219. Overvoltage Protection The NI 9219 provides overvoltage protection for each channel. Note Refer to the device datasheet on ni.com/manuals for more information about overvoltage protection. 28 ni.com NI 9219 Getting Started Guide

Excitation Protection The NI 9219 protects the excitation circuit from overcurrent and overvoltage fault conditions. The NI 9219 automatically disables the circuit in the event of a fault condition. Whenever possible, channels automatically recover after the fault is removed. Note Refer to the device datasheet on ni.com/manuals for more information about excitation protection. Measurement Type Pinout The following sections include pinouts for the NI 9219 measurement types. NI 9219 Getting Started Guide National Instruments 29

Voltage Pinout 1 4 HI 2 5 LO 3 6 Related Information Voltage Connections on page 16 Current Pinout 1 4 2 5 LO HI 3 6 Related Information Current Connections on page 17 30 ni.com NI 9219 Getting Started Guide

Thermocouple Pinout 1 4 HI 2 5 LO 3 6 Related Information Thermocouple Connections on page 18 4-Wire Resistance and 4-Wire RTD Pinout EX+ 1 4 2 5 3 6 HI EX- LO Related Information 4-Wire Resistance and 4-Wire RTD Connections on page 20 NI 9219 Getting Started Guide National Instruments 31

3-Wire RTD Pinout EX+ 1 4 2 5 3 6 Related Information 3-Wire RTD Connections on page 21 Full-Bridge Pinout EX+ 1 4 2 5 3 6 EX- LO HI EX- LO Related Information Full-Bridge Connections on page 22 32 ni.com NI 9219 Getting Started Guide

Half-Bridge Pinout 1 4 HI 2 5 EX- EX+ 3 6 Related Information Half-Bridge Connections on page 23 Digital In Pinout 1 4 HI 2 5 LO 3 6 Related Information Digital In Connections on page 24 NI 9219 Getting Started Guide National Instruments 33

Open Contact Pinout 1 4 2 5 LO HI 3 6 Related Information Open Contact Connections on page 25 34 ni.com NI 9219 Getting Started Guide

Where to Go Next CompactRIO CompactDAQ NI 9219 Datasheet NI-RIO Help LabVIEW FPGA Help NI 9219 Datasheet NI-DAQmx Help LabVIEW Help RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Located at ni.com/manuals Installs with the software NI 9219 Getting Started Guide National Instruments 35

Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for information about the services NI offers. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI 36 ni.com NI 9219 Getting Started Guide

also has offices located around the world. For support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For support outside the United States, visit the Worldwide Offices section of ni.com/ niglobal to access the branch office websites, which provide upto-date contact information. NI 9219 Getting Started Guide National Instruments 37

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/ patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2017 National Instruments. All rights reserved. 377223A-01 December 8, 2017