This Datasheet for the IC670MDL VDC 2A Output Pos. Logic 8 Pt. Electronic Short Circuit Protect

Similar documents
This Datasheet for the IC670MDL /24VDC 0.5A Output Pos. Logic 16 Pt. Grouped.

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

This Datasheet for the IC670MDL VAC 16 Pt. Input Grouped.

This Datasheet for the IC670MDL VAC 8 Pt. Isolated Input.

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

This Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.

This Datasheet is for the IC693MDL /24 Volt DC, 0.5A Positive Logic Output, 32 Point.

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

Discrete Output Modules IC697MDL740

This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits.

IC693PWR331 High Capacity Power Supply, 24 VDC Input

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

Discrete Output Modules IC697MDL750

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

This Datasheet for the IC660BBS103. Block 115Vac/125Vdc Low Leak Isolated I/O, w/o Failed SW Diagnostics, 8 Circuit.

PACSystems* RX3i IC695PSA140

Discrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module

This Datasheet is for the IC693ALG390. Memory Backup and Backup Battery.

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBD101. Block 115Vac I/O Low Leakage 8 Circuits.

PACSystems* RX3i IC695PSA040

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

PACSystems RX3i IC695PSA140

This Datasheet for the IC660BBA103. Block 115Vac/125Vdc Thermocouple Input 6 Channels.

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

Analog Input, 16-Bit Thermocouple Module

VersaMax* Analog Input, 16-Bit Thermocouple Module

Product Manual Dual SSR Relay Board

Installation Instructions

170 ADO VDC - 32 Pt. Discrete Output Module Base

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

VI-IAM /MI-IAM Input Attenuator Module

Power Supplies IC697PWR724/CE697PWR724

PFC Mini TM Power Factor Corrected AC-DC Switchers

GE Fanuc IC694ALG221. Rx3i PacSystem

Installation Instructions

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

VersaMax IP I/O Module

VersaMax IP Input Module

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

This Datasheet for the IC660BBD022. Block 24Vdc Source I/O 16 Circuits, 2/3 Wire Sensor Compatible

Relay Contact Output Modules

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

Single Phase Systems-North American PC125/PC420 Series

ADVANCED MICRO SYSTEMS

Model 2703AP Quick Reference Guide

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description

Table 1 shows all the different variations of output modules available.

5401 and 5402 Digital I/O Modules

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

Installation Instructions

Installation Instructions

Comm. RS-232. Analog I/O I N P U T S O U T P U T S. I/O Supply. Logic Supply RET RET Fault

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

AC Input /AC Output. Module

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Chassis Power Supplies

Installation Instructions

170 ADI VDC - 16 Pt. Discrete Input Module Base

This Datasheet for the IC693BEM331. Genius Bus Controller (Supports I/O and Datagrams)

USB-PDISO8 Specifications

USER S MANUAL Power Supply for Backplane Vdc

Telephony Multi-Taps. 9000T-TP Series

LED LIGHTING INRUSH CURRENT AND OVERCURRENT PROTECTION DEVICES

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

PRODUCT SPECIFICATION

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

ControlWave Micro Digital Input / Output Modules

VersaPoint I/O. Proficy Machine Edition. Publication Reference Chart

AIC1520. Ferrite Bead GND. *33µF, 16V Tantalum, or 100µF, 10V Electrolytic Bold line indicate high-current traces. USB High-Side Power Switch

SPECIFICATION. Model: OP650 Switching Power Supply With Active PFC PS/2 650W

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

BG1B Universal Gate Drive Prototype Board

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE

H-series (Rectifier Module)

Installation Instructions

Standard PACSystems 18-slot Wall (Rear) Mount. 15 Single Width, 8 Double Width (plus one for power supply) RX7i CPU and I/O, VME modules

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Cisco CRS 16-Slot Chassis Power Systems

Signal Conditioning Modules and Terminal Boards

REMOTE LOGIC I/O [INPUT/OUTPUT] PCB (LOGIO) Part No. 46S For use on MicroTrac DSD Local Area Network

flight of harmony POWER Barebones Pack ~v1.0~

Relay Deck Datasheet

KEPCO SINGLE OUTPUT, 1U SIZE, 100 WATT HOT SWAP PLUG-IN POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 100W SERIES

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

Table of Contents. 1 General 1.1 Scope

INSTRUCTION MANUAL. for. Kit, Variable Frequency and Voltage. for use with. Hobart Series A. 180 kva PoWerMaster Converter

MPCR Series Profibus-DP Technical Manual

How To Help Electronic Equipment Survive The Storm

Transcription:

This Datasheet for the IC0MDL0 VDC A Output Pos. Logic Pt. Electronic Short Circuit Protect http://www.qualitrol.com/shop/p-0-ic0mdl0.aspx Provides the wiring diagrams and installation guidelines for this GE Field Control module. For further information, please contact Qualitrol Technical Support at -00-- support@qualitrol.com

Discrete IC0MDL0 June (IC0MDL0) datasheet The VDC Electronic Short-Circuit Protection (IC0MDL0) provides a single group of discrete outputs. Each point has electronic overcurrent and short circuit protection, and generates a fault if either condition exists. 00 VDC POS OUT ESCP A PILOT DUTY SLOT F F F F F F F F VDC POS OUT ESCP A PILOT DUTY PWR Power Sources Power for the module itself comes from the power supply in the Bus Interface Unit. An external source of DC power must be provided for the switches that power the loads. LEDs Host Interface Individual green LEDs (logic side) indicate the on/off status of each output. The green LEDs remain off when user power is not present, regardless of the state of the outputs. Individual yellow LEDs show the fault status of each output. The green PWR LED is on when field and backplane power are present. Intelligent processing for this module is performed by the Bus Interface Unit or elsewhere in the system. This includes configuring features such as output default and fault reporting. The module has bits (one byte) of discrete output data. A Bus Interface Unit is required to obtain this output data from the host and/or local processor. Compatibility This module must be used with a Genius Bus Interface Unit IC0GBI00 (revision.0) or later. This module can be used with a Profibus Bus Interface Unit or Interbus-S Bus Interface Unit version.0 or later.

June Discrete Module Operation After checking the Board ID, the Bus Interface Unit sends output data to the module in serial format. During transmission, the module automatically loops this data back to the Bus Interface Unit for verification. Serial to parallel converters convert this data into the parallel format needed by the module. Opto-isolators isolate the module s logic components from field outputs. Power from the external power supply is used to drive the FETs that source current to the loads. Internal Module Circuitry Terminals Field Connections FLT PT Isolation and Control Sense Circuitry FET Switch.mF 0V.00mF 0 mf.00mf Output terminal (Return ) 0VDC Source Frame Ground 0 A MOV across the power supply lines protects the module from transient voltage surges. Capacitors across the supply lines and from each supply line to frame ground provide further noise protection.

Discrete June Current Limit Per Point The illustration below shows the current limits for the inrush cycle and steady-state conditions. Built-in overcurrent protection trips if the current exceeds the specified value or duration or if the steady state current exceeds the specified value. The short circuit protection trips if the load is shorted. An automatic.ms retry feature helps prevent false circuit trips caused by noise. Once an overcurrent or short circuit is detected, retry circuitry will turn the point off and back on within.ms. If the problem remains, the module generates a circuit fault. The module then turns the point off, regardless of its commanded state. Both LEDs are on when a fault occurs. When a fault is present, the state of the point cannot be changed the fault must be cleared before the point can be turned on. Faults can be cleared by sending the appropriate datagram or clearing the fault table or by cycling user power. The steady state overcurrent protection is set to trip at approximately. Amps. This protects the module from excessive currents that do not trip the short circuit protection. Caution Steady state current must be limited to Amps per point and Amps per module. Failure to observe these maximum load guidelines could result in misoperation or destruction of the module. Current (Amps) 0 0 0 Inrush and Steady State Rating 00 Steady State Time (ms) External Power Supply Requirements The external power supply used with the module must provide sufficient field power for the module during short circuit events. When a load is shorted, an inadequate external power supply may allow field power to drop below the specified operating range, causing misoperation of the module. The external power supply must be capable of providing short circuit energy without degradation of output voltage levels. The amount of energy required depends on the number of simultaneously-shorted points that might occur. Refer to power supply short circuit operation specifications prior to selecting the power supply to be used with the module. Local energy storage (either batteries or capacitors) can be used to compensate for insufficient power supply characteristics. Important Note: Additional best practices including minimizing wiring resistance from the external power supply to the module, preventing voltage drop during short circuit energy transfer.

June Discrete Module Specifications Module Characteristics User Input Voltage Keying Locations Output Voltage Range 0 VDC, VDC nominal. VDC to. VDC Continuous Load Current.0 Amps maximum per point Amps maximum per module Outputs per module Indicators Individual point status (green) Individual fault status (yellow) On = fault Internal V status from BIU and external supply (green) Isolation: User terminal to logic, 0 VAC continuous, 00 VAC for minute. User terminal to frame ground, Group to group No isolation between individual points in a group. Current Drawn from Bus Interface ma maximum Unit Power Supply Output Characteristics Inrush Current per point 0 Amps maximum for 0mS Steady State Overcurrent Trip Nominal range. Amps. Amps Point Output Voltage Drop 0. volt maximum Output Leakage Current 0.mA at 0 VDC maximum Response Time-On 00µs maximum Response Time-Off 00µs maximum Short circuit response time 0 Amps for 00µs Time between retries.ms maximum Protection (each output) Short Circuit protection, Overcurrent protection, MOV Optional keying locations for the VDC Electronic Short Circuit Protection are shown below. Keying Locations A B C D E F G H J K

Discrete June Field Wiring The Terminal Block with box terminals has terminals per module, each of which accommodates one AWG # (avg.mm cross section) to AWG # (avg 0.mm cross section) wire, or two wires up to AWG # (avg. 0.mm cross section). Using an external jumper reduces wire capacity from AWG # (.0mm ) to AWG # (.mm ). The I/O Terminal Block with barrier terminals has terminals per module. Each terminal can accommodate one or two wires up to AWG # (avg.0mm cross section). The I/O Terminal Block with Connectors has one 0-pin male connector per module. The following illustration shows terminal assignments for the VDC Electronic Short Circuit Protection. The eight outputs form one group, with a common return. I/O Terminal Block with Box Terminals (IC0CHS00 and 0) Retur n Retur n Retur n Retur n Retur n Retur n Retur n Retur n E 0 E E E B B E A A Output 0 Output Output no connect Output Output no connect Output Output no connect Terminals E, E, E, E, and E are electrically connected together, A and A are electrically connected together, B and B are electrically connected together. I/O Terminal Block with Barrier Terminals (IC0CHS00 and 0) Retur n Retur n Retur n Retur n Retur n Retur n Retur n Retur n 0 B A Output Output Output Output Output Output Output 0 0 I/O Terminal Block with Wire to Board Connectors (IC0CHS00 and 0) Output Retur n Output Retur n Output Retur n A A B B 0 Retur n Output Retur n Output Retur n Output Retur n Output Retur n Wiring Examples with Auxiliary Terminal Blocks The following illustration shows example module wiring to the module. Example connections, terminal block with box terminals Load Return Output Load + Return DC DC + 0