RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Similar documents
Binary output and supervision 520CSD01 Data sheet

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

Analog output 520AOD01 Data sheet

ABB 520BID01 Binary Input datasheet

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Characteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01

Bus Connection Unit 560BCU04

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Messaging module CP-C MM

Characteristics. Application RTU560. DIN Rail RTU 560CIG10. Data Sheet DIN Rail RTU 560CIG10

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Application. Characteristics RTU560. DIN Rail RTU 560CIG10. Data Sheet DIN Rail RTU 560CIG10

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

DI572 Digital Input Module

DC561, digital input/output module,

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

DI561 Digital Input Module

DC562, digital input/output module,

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

DIN Rail RTU 540CMD01 Data sheet

Redundancy unit CP-A RU

Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3.

AI561 Analog Input Module

DX561 Digital Input/Output Module

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

TM3AI4 module TM3-4 analog inputs

TM3TI4 module TM3-4 inputs temperature

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

TM3DI16 module TM3-16 inputs

TM3TI8T module TM3-8 inputs temperature

TM3DI16G module TM3-16 inputs spring

TM3SAF. Main. Device short name

TM3TI4 module TM3-4 inputs temperature

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

02/11/2015

TU531, TU532 Terminal Unit

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

TM221CE24R controller M IO relay Ethernet

TM221M16R controller M IO relay

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

AO523 Analog Input Module

TM241C40R controller M IO relay

TF501, TF521 Terminal Bases

Pluggable interface relays CR-P Pcb relays

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Control Panel CP600-eCo CP604, CP604-B

TM3TM3 module TM3-2 temperature inputs and 1 analog output

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

02/11/2015

TM3DM8R module TM3-8 IO relays

MRA1 Trip circuit supervision. Manual MRA1 (Revision A)

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Control Panel CP600 CP651, CP651-WEB

Thermistor motor protection relay CM-MSS.21

TM200C24R controller M IO relay

08/07/2015

AX521 Analog Input/Output Module

AO561 Analog Output Module

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Thermistor motor protection relay CM-MSS.41

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

TM241CE40R controller M IO relay Ethernet

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Control Panel CP600 CP635, CP635-B, CP635-WEB

TM3SAK. Main. Device short name

Contact protection relay

TM241C40U controller M IO transistor NPN

DC532-XC, digital input/output module,

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

CD522 Encoder, Counter and PWM Module

Thermistor motor protection relay CM-MSS.11

TM221CE40T controller M IO transistor PNP Ethernet

TM241C24T controller M IO transistor PNP

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

ABB i-bus KNX BCI/S Boiler/Chiller Interface

CI542 PROFIBUS Communication Interface Module

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Power supply CP-E 48/1.25 Primary switch mode power supply

Relion 611 series. 611 series Type Test Certificate

Transcription:

Binary Output 23BO62 Characteristics The binary output is made via relay contacts. The 8 outputs are potential isolated against the electronic by optocoupler. All 8 outputs have a separate return. Application The binary output board 23BO62 can be used for the output of up to 8 binary signals to the process, using relay contacts. The assignment of an output to a number of processing functions can be freely undertaken within the scope of the configuration rules. The 23BO62 can be used for the following types of signal: Object commands with 1 or 2 pole output without (1 out of n) check Object commands with 1.5 or 2 pole output with (1 out of n) check Regulation Commands, 1 and 2 pole Digital Setpoints (8 Bit) Bitstring Output, 1 or 8 Bit The board is available in two versions: 23BO62 R0001 23BO62 R0009 for up to 150 V DC or max. 10 A for up to 60V or for max. 4A The supply voltage (U E ) for the internal relays has to be supplied from external (e. g. from 511CIM01). Two outputs of the board 23BO62 are required for each command in the case of two pole commands (e.g. for double commands C 1 together with C 3, and C 2 together with C 4). U P 23BO62 C1. C8 R1.. R8 + - Figure 1: Function block diagram Binary output board 23BO62 U E Doc.-No.: 1KGT 150 833 V000 1 1

The binary output board 23BO62 can execute the following processing functions on the individual signal types: Control of the command output duration (following instruction from the CMU, CMU = communication unit) Before and during command output the board 23BO62 carries out several monitoring functions: (1 out of n) check of the process relay, by using the supervision function of 511CIM01 or 560CIG10/560CID11 modules. Monitoring the external process voltage (24 V DC) command output duration monitoring If a fault occurs during running of tests the command will be cancelled. The board micro-controller is responsible for interactive communication with the system bus. All configuration characteristics and processing parameters are downloaded from the communication unit via the RTU system bus. The board is equipped with a serial interface to the RTU system bus (Wired-OR Bus). When using the binary output board in a RTU560 rack configuration, it is necessary to connect one I/O adaptor board 23AD64 in front of the first I/O board. During initialization and operation the board carries out a number of tests. If a fault occurs it is reported to the communication unit. All fault conditions impairing the function of the board are displayed as common fault signal with a light emitting diode (Error). A failure of the board is detected by the communication unit. Operating states and faults are displayed by light emitting diodes of the 23BO62: LED 1 8: Display the active outputs ST: Common malfunction information of the board BL: LED is always active with RTU511 PST: LED is always inactive with RTU511 CO: LED is always inactive with RTU511 Doc.-No.: 1KGT 150 833 V000 1 2

Technical Data In addition to the RTU500 series general technical data, the following applies: Output Circuits Outputs Characteristics R0001: Max. switching voltage Max. switching power (resistive load) Inductive load L / R 40 ms Current time, max. 30 seconds Continuous current Max switching current Characteristics R0009: Max. switching voltage 8 Relay Contacts, single pole 150 V DC 240 Watt 50 Watt 10 A @ 30 V DC 3 A @ 110 V DC 6 A @ 30 V DC 10 A @ 30 V DC 60 V DC Mechanical Layout Length Width Height Connection Type Process connector Insulation AC Test Voltage EN 61000-4-16 IEC 60870-2-1 (class VW3) Impulse Voltage with stand test IEC 60255-5 IEC 60870-2-1 (class VW 3) 140.0 mm 107.5 mm 20.0 mm Removable Screw Terminals 2,5 kv, 50 Hz Test duration: 1 min 5 kv (1,2 / 50 µs)* Max. switching power (resistive load) Inductive load L / R 30 ms Current time max. 25 seconds Continuous current Max switching current 60 Watt 40 VA @ 60 V 4 A @ 24 V 2 A 2 A @ 24 V * Only for: 23BO62 R0009: 4kV without galvanic isolated 24V DC power supply at connector X3 5kV with galvanic isolated 24V DC power supply at connector X3 Current Consumption 5 Volt 70 ma 15 Volt - 18 Volt - R0001: 24 V DC (external) R0009: 24 V DC (external) 230 ma for 8 relays per relays 30 ma 90 ma for 8 relays per relays 10 ma Doc.-No. 1KGT 150 833 V000 1 3

Electromagnetic Compatibility Electrostatic Discharge Immunity Test IEC 61000-4-2 Radiated Radio- Frequency Electromagnetic Field Immunity Test IEC 61000-4-3 Immunity to Electrical Fast Transient / Burst IEC 61000-4-4 Surge Immunity Test IEC 61000-4-5 Immunity to Conducted Disturbances, induced by Radio- Frequency Fields IEC 61000-4-6 4 kv Contact 8 kv Air 10 V/m 4 kv 2 kv Environmental Conditions 10 V Temperature -25 70 ºC Relative humidity 5 95 % (not condensing) Ordering information 23BO62 1KGT 014600 R0001 23BO62 R0009 1KGT 014600 R0009 Doc.-No.: 1KGT 150 833 V000 1 4

Note: We reserve the right to make technical changes or modify the con-tents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB AG. Copyright 2013 ABB All rights reserved Dok.-Nr. 1KGT 150 833 V000 1 5