lighting, electrics & communications

Similar documents
lighting, electrics & communications

lighting, electrics & communications

meeting tables P RO D U C T M A P / TA B L E C O N T E N T S M E E T I N G TA B L E B A S I C S

meeting tables MEETING TABLE BASICS TABLE BASE DIMENSIONS RECESSED POWER/DATA MODULE DETAILS

lighting, electrics & communications

electrics PRODUCT MAP / TABLE OF CONTENTS ELECTRICS & COMMUNICATIONS OVERVIEW POWER ENTRY BASICS PANEL-MOUNTED WORKSTATIONS..

lighting, electrics & communications

lighting, electrics & communications

Electrical Accessories

ALLOY BENCHING PRODUCT SPECIFICATIONS

lighting, electrics & communications

Haworth Power Technical Sheets January 2018

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

worksurface supports & accessories

Rumble Seat and Hoodie

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions

Trig Planning Guide. December 2012

SM (SURFACE MOUNTED) WIREWAY: I SERIES

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU

Power/Data Instructions. Genius. Movable Walls. September

UNDERCARPET CABLING SYSTEM For Power and Communications

DESCRIPTION PRODUCT CODE LIST PRICE DIMENSIONS/INCHES H L D

U-SERIES SPECIFICATION GUIDE

Smartspace Benching System

Jack Plates. Jack Plates & Accessories PREMIER. PT-625B1 Flush Jack. PREMIER PT-625B3 Flush Jack

XSEDE HEIGHT ADJUST. Table of Contents. Xsede Height Adjust Kimball Benching. Price List Effective Dates: Pricing Revision

6' RJ11 Cable for Remote Switching and Dimming of Uplight HPF Power Supply and Enclosure with 6' Power Cord

Expansion Casegoods overview

electrical evolvefurnituregroup.com 125

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

STORAGE & ACCESSORIES

storage for secondary desks

Assembly Instructions

ACCESSORIES price list effective January 1, 2018

POWER / DATA SOLUTIONS

Installation Instructions

This attractive raceway conceals and

Integrated Connectivity

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying

Grommets & OFFICE Accessories

WIREMOLD Tele-Power Poles

resistance for high requirement

ACCESSORIES ACCESSORIES ACCESSORIES NATIONAL OFFICE FURNITURE TABLES 519

Cable Management Solid Cherry Wood Durable Desk Inlay Integrated Power Strip Versions: L Shaped Right. L Shaped Right

36'' Plan View of Circuit Base. description sku w d h weight specifications price

This attractive raceway conceals and

T A B L E O F C O N T E N T S

This attractive raceway conceals and

XSEDE POWER BEAMS and PANELS

storage for secondary desk

PRODUCT SPECIFICATIONS Pillar Table

PHYSICAL INFRASTRUCTURE QUICK SKU FINDER

Desks. Desks. Modern Urban Series Computer Desks. Modern Urban Series Computer Desks. Modern Urban Series Computer Desks

active storage C A D D I E & T RO L L E Y B A S I C S...6 4

ISE Work : Learn : Inspire

WIREMOLD. innovative wire and cable management

NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories

SPECTRUM-2 CONSOLES. TEL: WEB: winsted.com

application guide D E S K S R E T U R N & C O R N E R D E S K S R E Q U I R I N G S H A R E D S U P P O RT...1 5

Expansion Desking overview

NT-2300 Series Dual Circuit Track System & Accessories

Sit-Stand Monitor Arm

25DTP412 12'5" Tele-Powr Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight

PG LIFELINK INNOVATION IN POWER SAFETY LABLINK. LED LabLights Laboratory Connection Products Aluminum Surface Mount Raceways VERSA-DUCT

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

ABERDEEN LAMINATE SERIES

LED Light Kit. Install Instructions for LIGHT-KT outdoorrooms.com

Morrison, Currents and Reff Raceways Morrison, Currents and Reff Raceways

application guide D E S K S R E T U R N & C O R N E R D E S K S R E Q U I R I N G S H A R E D S U P P O RT...1 5

QuickNetwork QND200 Distribution Panel

2.7 UNDER-CARPET WIREWAY

Grommets & OFFICE Accessories

VOX ACCESSORIES VOX ACCESSORIES

DOCKING STATION SPECIFICATIONS

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

Installation Notes TII Model 341 Protector

Eaton LCD Lift Flat Panel Display System. Installation Guide

application guide westcoast price & application guide June 23, 2008 DESKS...14 RETURN & CORNER DESKS REQUIRING SHARED SUPPORT...15

PRESTIGE SIGHT-LINE CONSOLES PRESTIGE. Sight line

QuickNetwork QND300 Distribution Panel

With its tamper-resistant design, the

S Y S T E M S O L U T I O N S CONTEXT

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

The Solid Wood Standing Desk that Hides your Wires and Cables

What do you want to build today?

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

CAUTION READ CAREFULLY

A-dec 586 Ceiling Monitor Mount

Veneer: Ribbon Sapele with dark rift oak finish NN331 panel base/rectangle top/knife edge/technology trough converge buffet height credenza with

Marina HDMI Install Instructions

25DTP4DG Tele Power Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight

dewey statement of line

LIGHTING S. Table of Contents. Lighting Kimball Surfaces & Storage. Price List Effective Dates: Pricing Revision

AURABENCH. Product Guide

CableSmart Series Nonmetallic Raceway

Telephone Accessories

Rapport Island Power Apron

REMOTE HEAD ADAPTER INSTALLATION GUIDE

ON-FLOOR WIREWAY PRICELIST AUGUST 1, 2017

PRODUCT PRICING GUIDE US & Canada

Transcription:

lighting, electrics & communications P RO D U C T M A P / TA B L E C O N T E N T S.....................4 L I G H T I N G, E L E C T R I C S & C O M M U N I C AT I O N S O V E RV I E W....4 4 L I G H T I N G B A S I C S.................................4 5 B E A M - M O U N T E D P OW E R & C O M M U N I C AT I O N S B A S I C S.....4 6 U N D E R S TA N D I N G D ATA / C O M M U N I C AT I O N S.............4 7 P OW E R E N T RY B A S I C S..............................4 9 P OW E R D I S T R I B U T I O N B A S I C S........................4 4 0 P OW E R D I S T R I B U T I O N F O R H E I G H T- A D J U S TA B I L I T Y B A S I C S.........................................4 4 P OW E R & C O M M U N I C AT I O N S M A N A G E M E N T A N D U S E R A C C E S S....................................4 4 P RO D U C T L I S T I N G................................4 4 6 4 expansion cityline price guide January, 08

lighting, electrics & communications product map J N E L E D Linear LED LIght J N E A D Access Door J N E W C Wire Management Clip Page 446 Page 447 Page 448 J N E W P T Cable Tray J N E W M T Cable Tray for Access Door J N E C B Communication Box Page 449 Width: 8" Page 449 J N E D E Communication Extended Plate J N E C B P Communication Blank Plate J N E P C Power Cube Page 450 Page 45 Page 45 Power Cord Length: 0" or 80" J N E P P Underworksurface Plug-In Power Bar J N E P B Power Box J N E P M H Power Module Storage for HeightAdjustability Page 45 Length: 7" or 80" Page 454 Page 455 Cable Length: 48" Page 448 Width: " expansion cityline price guide January, 08

product map (continued) J N E P R O Receptacle Outlet J N E P D B Four-Way Splitter J N E P I C i-connector Page 456 Page 457 Page 458 J N E P H Power Harness J N E P B F Base Feed J N E P C F Ceiling Feed Page 459 Length: 8" 44" Page 460 Length: 7" Page 46 Length: 96" 44" J N E W P P Power Pole J N E G Q Square Grommet J N E G R Rectangular Grommet Page 46 Height: 9" 44" Page 46 Page 464 J N E G P C Cable Pass-Through Cover J N E C F K USB/Data Faceplate Kit Page 465 Page 466 expansion cityline price guide January, 08

lighting, electrics & communications overview Expansion Cityline offers a non-directional wiring system that allows for maximum flexibility and simple reconfiguration. Moreover, it offers varieties of data/power access such as direct access under or above worksurface and hidden access under worksurface. 5 6 4 4 5 6 Power is provided to workstations by a Base Feed (Shown) or Ceiling Feed. Power Feed can be hidden by a Power Pole Power Box must be mounted on beam cut-out location and Receptacle Outlets must be mounted on Power Box Cable Tray for Access Door can be used underneath worksurfaces to manage extra wires routed through the Access Door Cable Tray can be used undeneath worksurfaces to manage Plug-In Power Bar and extra wires routed through grommets Power Cube can be mounted on worksurface square cut-out to provide electric/data/usb above the worksurface Linear LED Light can be mounted on Mounted Storage to provides local task light or ambiance lighting expansion cityline price guide January, 08

lighting basics Expansion Cityline LED strip lighting solution provides energy efficient lighting when mounted-storage is used on the worksurface. Check local codes for potential limits or restrictions on products. Local authority approval may be required prior use Some jurisdiction require Resettable Breakers. Check local codes All dimensions are nominal Linear LED Light (JNELED) Equipped with an energy-efficient strip of LEDs Can be magnetically mounted on Linear LED Light Support (JNASL) and on Elevated Slim Cabinets with Display (JNMSD). Linear LED Light dimension must be the same than Support and equal or smaller than Display Magnetic plates with self-adhesive foam tape are provided for non-magnetic application For storage products, the specified width should be one size smaller than the width between supports of the cabinet to which it will be attached This product includes a 7" cord from plug to AC/DC adapter, and 8" from adapter to light Made with 95 % of recycled material. Life expectancy of 50 000 hours Light Finish: Clear Anodized (AC) only lighting dimension vs storage Equal JNASL 9" Equal OR Smaller 9" JNMELF JNMEL JNMLS JNMSO JNMSD JNMDS JNMDH JNMDO /" Equal OR Smaller /" " Equal OR Smaller " expansion cityline price guide January, 08

beam-mounted power & communications basics The following outlines the features of Expansion Cityline Power and Communications products. Check local codes for potential limits or restrictions on products. Local authority approval may be required prior use 5 4 Finishes... Receptacle Outlets Finishes: Ebony (YY), Storm White (YF), Platinum Grey Coordinate (YN) and Very White Coordinate (YV) Communication Blank Plate Finishes: Ebony (YY), Storm White (YF), Platinum Grey Coordinate (YN) and Very White Coordinate (YV) Communication Extender Plate Finishes: Ebony (YY), Storm White (YF), Platinum Grey Coordinate (YN) and Very White Coordinate (YV) 4 5 Power Box (JNEPB) is universal for single- and double-sided applications. Mounted inside the beam at cut-out location and allows mounting up to four Receptacle Outlets (JNEPRO), two on each side. Offers an 8-Wire Isolated Ground (8T) or Dual Isolated (8K) circuits. Offers Standard (S) or PVC free (V) option. Positions on Structural Beam are not all available depending on beam width. Refer to Desk Structures section for details Receptacle Outlets (JNEPRO) are mounted onto Power Box and provide power or USB charging to workstation Communication Extender Plate (JNEDE) is mounted on beam data cut-out. Mandatory only when used with Structural Beam Cover Side (JNDBCS) or with CAT6 jacks. Allows the mounting of modular furniture adapter (not included) with modular jacks (not included) or Communication Blank Plate (JNECBP) if data is not required Communication Blank Plate (JNECBP) is used when no data access is required. Can be mounted directly on Structural Beam (JNDBB) or on Communication Extender Plate (JNEDE) Wire Management Clips are included with Structural Beam (JNDBB) and retain wires inside Structural Beam expansion cityline price guide January, 08

lighting, electrics & communications understanding data/communications Expansion Cityline uses desk structure to run electric and data/communication cables through the workstations. Structural beam is the principal component that allows wire management and installation of power and data access for users. Check local codes for potential limits or restrictions on products. Local authority approval may be required prior use structural beam data/communication cables capacity 40% empty space should be considered to ensure future workstations expansion and routing wires in tight corners CAT5e CAT6a Power Box (JNEPB) Power Harness (JNEPH) Power Harness (JNEPH) 6 Data Cables Cat5 (dia 0.") @ 60% Filling Rate 5 Data Cables Cat6 (dia 0.") @ 60% Filling Rate Wire Management Clip structural beam data/communication cut-out Structural Beam data/communication cut-out allows the installation of Voice/Data faceplates (not included) and jacks (not included), Communication Extender Plates (JNEDE) or Data Covers and Voice/Data Adapters of USB/Data Faceplate Kit (JNECFK).7".8" USB/Data Faceplate Kit (JNECFK) Features Data Cover and Voice/Data Adapters Can accommodate up to two voice/data ports.75" Can be installed on following products: Structural Beam (JNDBB) Communication Extender Plate (JNEDE) Communication Box (JNECB) Power Cube (JNEPC).4" with Communication Extender Plate (JNEDE) Faceplate Finish: Platinum Grey Coordinate (YN)* * Matches with standard grey simplex expansion cityline price guide January, 08

lighting, electrics & communications understanding data/communications (continued) Fully concealed and exposed Structural Beam application allow many possibilities to provide Communication/Data/Voice/USB access to users; see examples below without structural beam cover short modular jacks long modular jacks Voice/Data faceplates and jacks (Not included) Voice/Data faceplates and jacks (Not included) Communication Extender Plate (JNEDE) data/usb faceplate short data/usb faceplate long USB/Data Faceplate (JNECFK) USB/Data Faceplate (JNECFK) Communication Extender Plate (JNEDE) with structural beam cover data/voice adapters USB/data faceplate blank Voice/Data faceplates and jacks (Not included) Communication Extender Plate (JNEDE) expansion cityline price guide January, 08 USB/Data Faceplate (JNECFK) Communication Extender Plate (JNEDE) Communication Blank Plate (JNECBP) Communication Extender Plate (JNEDE)

power entry basics Power can enter into Expansion Cityline desk structure from either a Base Feed or a Ceiling Feed. Both can be aesthetically covered by a power pole. Check local codes for potential limits or restrictions on products. Local authority approval may be required prior use Power Pole can route a Ceiling Feed (JNEPCF) and data cables from the ceiling to the workstation Power Pole can route a Base Feed (JNEPBF) and data cables into workstation from the floor Base Feed (JNEPBF) Connects to the building supply. Routes power from the floor into desk structure, then on a Power Box (JNEPB), a Four-Way Splitter (JNEPDB) or a I-Connector (JNEPIC) Wire systems include 8-Wire Isolated Ground (8T) and 8-Wire Dual Isolated (8K) This product is only available in 7" watertight cord length Offered in Standard (S) or PVC Free (V) option Ceiling Feed (JNEPCF) Includes a junction box to connect to the building supply. Routes power from the ceiling into desk structure, then on a Power Box (JNEPB), a Four-Way Splitter (JNEPDB) or a I-Connector (JNEPIC) Wire systems include 8-Wire Isolated Ground (8T) and 8-Wire Dual Isolated (8K) This product is available in 96", 0" and 44" cord length Offered in Standard (S) or PVC Free (V) option Power Pole (JNEWPP) Connected to the desk structure, routes a Base or Ceiling Feed and data cables into workstation. Available with Solid Gable/Floor Screen or Structural Leg/Beam mounting option This product is available 9" high for Base Feed and 96", 0" and 44" high for Ceiling Feed Finishes: Foundation, Mica and Accent expansion cityline price guide January, 08

power distribution basics The following outlines the features of power distribution products in Expansion Cityline. Check local codes for potential limits or restrictions on products. Local authority approval may be required prior use All dimensions are nominal 4 5 Power Box (JNEPB) A module for mounting up to two Receptacle Outlets (JNEPRO) on each side Attaches inside Structural Beam (JNDBB) Power Boxes are two-sided. Can accommodate two Receptacle Outlets on single-sided applications and four Receptacle Four-Way Splitter (JNEPDB) Distributes power in or directions Outlets on double-sided applications 4 I-Connector (JNEPIC) Has two connectors for receiving in-feed and distributing Used to join two harnesses when a single harness is current to the rest of the station not long enough Wire systems include 8-Wire Isolated Ground (8T) and 8-Wire Dual Isolated (8K) Offered in Standard (S) or PVC Free (V) option Receptacle Outlet (JNEPRO) A one piece duplex receptacle that slides onto the Power Box (JNEPB) to provide power Specified individually for maximum circuit flexibility Wire systems include 8-Wire Isolated Ground (8T) and 8-Wire Dual Isolated (8K) Available in Circuits,,, 5 and 6 Receptacle Outlet configurations consist of Circuit,, (used with 8T only), 5 and 6 (use with 8K only) and USB charging outlets Available in 5 or 0 amp (0amp only available in Ebony) Offered in Standard (S) or PVC Free (V) option Finishes: Ebony (YY)*, Storm White (YF), Platinum Grey Coordinate (YN) and Very White Coordinate (YV) * When T-Slot 0 Amp Receptacle Style (T) is specified, only Ebony (YY) finish is available expansion cityline price guide January, 08 5 Power Harness (JNEPH) Routes power through desk structure by connecting to a Power Box (JNEPB), a Four-Way Splitter (JNEPDB) or a I-Connector (JNEPIC) Power Harnesses are non directional Wire systems include 8-Wire Isolated Ground (8T) and 8-Wire Dual Isolated (8K) Lenghts include 8" 6" (" increments) and 4" 44" (6" increments) The 8", " and 4" long harnesses are mesh construction, all others sizes are metal conduit Offered in Standard (S) or PVC Free (V) option

power distribution for height-adjustabilty basics The following outlines the features of power distribution products for height-adjustability in Expansion Cityline. Check local codes for potential limits or restrictions on products. Local authority approval may be required prior use Power Module Storage for Height-Adjustability (JNEPMH) A Power Module that includes duplex and simplex to supply power for Height-Adjustable Run-Off and up to two more devices Installed inside Storage Cabinet for Height-Adjustable Run-Off (JNHSC) Comes with one connector to attach to a Power Box (JNEPB), a Four-Way Splitter (JNEPDB) or an I-Connector (JNEPIC) Wire systems include 8-Wire Isolated Ground (8T) and 8-Wire Dual Isolated (8K) Available in Circuits,,, 5 and 6 Outlet configurations consist of Circuit,, (use with 8T only), 5 and 6 (use with 8K only) Simplex is 5 amp and duplex is available in 5 or 0 amp Offered in Standard (S) or PVC Free (V) option Finish: Platinum expansion cityline price guide January, 08

power & communications management and user access Cable management and user access to power/communication must be considered when planning workstations in Expansion Cityline. 44 Worksurfaces can be mounted on or without Structural Beam. Both mounting styles require different components to provide access to power/communication and for cable management 44 beam-mounted worksurfaces 44 44 44 44 44 44 44 Access Door (JNEAD) Access Door can be specified as an option on worksurface or can be field-installed for direct access to beam-mounted power/data Pivoting door provides two access for cables: on back for permanent devices and in front for daily use cables Finishes: Foundation, Mica and Accent Cable Tray for Access Door (JNEWMT) The cable tray for Access Door attaches to the underside of a worksurface to manage extra wires from user devices Finishes: Foundation, Mica and Accent 44 44 44 /" Communication Box (JNECB) The communication box can be attached to the underside of a worksurface to provide communication/data to user The communication box must be installed at /" away from Access Door side to clear Receptacle Outlets Finish: Platinum Coordinate 44 44 expansion cityline price guide January, 08

power & communications management and user access (continued) unstructured worksurfaces Wire Management Clip (JNEWC) Manages and conceals power and data wires underneath the worksurface Wire Management Clips have an open section to manage big cables such as power cord/harness and another one with flexible flange to retain smaller cables as data Two are supplied with each worksurface and more can be ordered separately Finish: Black Cable Tray (JNEWPT) Is mounted underneath worksurfaces to manage cables coming from the worksurface level Allows installation of Underworksurface Plug-In Power Bar (JNEPP) only One is supplied with each worksurface with grommets or Access Door and more can be ordered separately Finish: Black Underworksurface Plug-In Power Bar (JNEPP) This product can be clipped on Cable Tray (JNEWPT) Provides a -wire system that can be used to connect up to four devices and includes a resettable breaker This product includes 7" or 80" power cord with flat 45 plug Finish: Clear Anodized Cable Tray Underworksurface Plug-In Power Bar expansion cityline price guide January, 08

power & communications management and user access (continued) The Power Cube is a -wire alternative to provide power/communication/usb charging above and under worksurfaces. power cube Finishes... Case & Front Finishes*: Foundation, Mica and Accent * When Under Worksurface (U) option is specified, the underworksurface bracket will match the Case and Front finish Power Cube (JNEPC) Provides power, data or USB charging access above worksurface Fits into Square Cut-Out Ring on worksurfaces and is installed without tools. The Square Cut-Out option must be specified on worksurfaces for installation Voice/Data jacks are not included and must be field supplied and installed Plugs directly into standard receptacle This product includes 0" or 80" power cord with straight plug Permanent equipment cords can pass through the square cut-out using the side slot Up to /8" wire Dual Power Cube Power Simplex Receptacle USB Communication Opening 0 0 Configuration D00 (S) (U) 0 0 D0 D0 Quad Power Cube 0 0 Q0 Q0 (S) (U) 4 0 Q Q40 expansion cityline price guide January, 08

power & communications management and user access (continued) Grommets provide aesthetic cables management when needed. grommets Square Grommet (JNEGQ) Square Cut-Out option must be specified on worksurfaces for an easy installation Grommet can also be field-installed as per template provided when cable management is needed The Square Grommet Ring allows installation of Dual or Quad Power Cube (JNEPC), which are not included and must be specified separately Cover can be secured in place with provided wood screws Aluminum Cover Finishes: Foundation, Mica and Accent Plastic Ring Finish: Soft Gris Coordinate (B) Square Grommet mounting: Rectangular Grommet (JNEGR) Can also be specified as an option on worksurfaces. The surface will come with pre-drilled holes for easy installation on-site Grommet can be field-installed if specified separately as per template provided when cable management is needed Rectangular Grommet can be interchanged with Mast Monitor Arm Expansion Grommet mounting option and vice versa Cover Finishes: Soft Gris (6), Platinum (60), Anthracite (68), Storm White (74) or Very White (8) Plastic Ring Finish: Ebony (5) Rectangular Grommet mounting: A B C A B C Gable Pass-Through Cover (JNEGPC) Covers the Gable Pass-Through ring and can be specified separatly when pass-through is not used Finishes: Foundation, Mica and Coordinate Colors* * Coordinate Colors are solid colors that can be used to match wood print: Maple (M5), Anigre (M6), Cherry (M7), Royal Cherry (M8), Espresso Reflect (Q4), Stainless (Q6), Walnut Cathedralgrain (Q7), Mercurial Walnut (Q9), Java Walnut (R7), Urban Walnut (R8), Choice Maple (R9), Estate Cherry (V), Campus Oak (VD), Flax Reflect (VL), Pecan Reflect (VV), Cocoa Brown Reflect (W8) and Sycamore Reflect (W9) expansion cityline price guide January, 08