INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-300

Similar documents
RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

MAXIMA + Series ROTARY LEVEL CONTROL

700 Series 200 Amp Clamp Meters

PCM-7140 Pulsed Current Source Operation Manual

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

AirTest Model CN9000 Series Sensor Controller

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

INSTRUCTION MANUAL A START-UP AND SHUT DOWN LOAD SEQUENCER AND AUTOMATIC LOAD SHEDDING SYSTEM WITH INTEGRAL RELAYS FOR 8 LOADS MODEL #091-60A

Global Water Instrumentation, Inc.

PMDX-170 Slotted Optical Sensor

MAXIMA + Series ROTARY LEVEL CONTROL

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PWRguard PLUS Spring City Drive Waukesha, WI

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

MAXIMA+ Series Rotary Level Indicator

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

FA-2448 SIX POSITION Filter Wheel

212iL Rev. 1.1

PIM-Mini Pulsed Current Source Operation Manual

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

poly-planar Marine Audio System

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error:

PGR-3200 MANUAL INSULATION MONITOR

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

PMDX-105 Quad Isolator Board

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

INSTALLATION INSTRUCTIONS

PS8 - II. Professional Power Sequencer. User s Manual

V-9939B MICROPHONE ADAPTER

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Model 3526-B Digi-Probe Multimeter

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Model HM-535 Power Supply Installation and Service Instructions

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Energy Management System. Operation and Installation Manual

FBT-10. Fieldbus Commissioning Box. User Manual FBT-10 User Manual Rev A.0

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

Innovative Circuit Technology Ltd.

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

S82S (3/7.5-W Models)

Global Water globalw.com. Global Water. Instrumentation, Inc.

BG-N19-2. Designed for the Nikon D850 DSLR Camera

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

BG-N4.2 BATTERY GRIP. Designed For The Nikon D7000 SLR Camera

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

MODBUS MANUAL For the AccUView UV Transmission Monitor

Chassis Power Supplies

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

Basketball Shot Clock Set LX2180 Manual

AE14-503J SERIES PRODUCTION DISPLAY SYSTEM

LPG STM 94442A User s Manual

Specifications, Installation, and Operating Instructions

Tempco Instruction Manual

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Irrigander 8/2 Pro Expander 8 Zone Irrigation Expander Installation & User Guide Model 8ZEXT V1.0

Power Supply (48Vdc, 2.5A)

AB0602D ARCHITECTURAL BALLAST DRIVER. Version Date 06/25/2012

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Variable Temperature Digital Solder and Testing Station

CarSense202 O P E R A T I N G I N S T R U C T I O N S V E HI C L E M O T I O N D E T E C T O R Johnston Parkway, Cleveland, Ohio 44128

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

User's Guide. Extech AM A AC Analog Clamp Meter

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

PS-4100 POWER SUPPLY MANUAL

OPERATIONS MANUAL PCM-I/O48

Global Water Instrumentation, Inc.

2U Congestion Alert Rack Insert for UK

PDC-X Digital Controller

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

Model E100RC. DC Millivolt Reference Source ±1µV to ±10Vdc - 10ppm Resolution. Operating Manual

BG-N10. Designed for the Nikon D600 and D610 SLR Camera

SP6R Level Controller Operation Manual

Installation, Operation and Maintenance Manual

Seven Channel Remote Control

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

OWNER S MANUAL Calc-U-Dri PRINTER

Remote Microprocessor Control Panel. for use with the. Redi-Purge. High Efficiency Purge System

CR87B TEMPERATURE RECORDER

Transcription:

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-300 COPYRIGHT 1988 American Mine Research, Inc Manual Part Number 160-0094 Original: 07-19-88 Revised: 03-28-90 NOT TO BE CHANGED WITHOUT MSHA APROVAT.

Table of Contents INTRODUCTION 2 OPERATION 3 TEST SWITCH 4 SENSITIVITY 4 GENERAL INFORMATION 5 OPTIONAL TRIP INDICATOR 6 OPTIONAL BATERY 6 TROUBLE SHOOTING 6 TEST READING 7 OUTPUT CONTACTS 7 BATTERY VOLTAGE 8 PROBLEM / SOLUTION 8 SPECIFICATION 11 APPENDIX A 12 APPENDIX B (Repair parts list) 13 AMR DRAWING NUMBER 180-0096 14 TEMPLATE 1 15 WARRANTY 16

AMR Ground Check System GM-300 INTRODUCTION The American Mine Research GM-300 Ground Check System is intended for use on all systems where pilot and ground wire loop resistance is at least 4 ohms and not greater than 14 ohms. Ground check systems using GM-300 are auditable for application on power systems up to 25 KV A.C. including low and medium voltages. For power systems over 25 KV contact AMR for recommendations. The following describes ground check systems using the GM-300. Complete GM-300 package for 129 volt input is comprised of the following typical components: 1 120/24V single phase, dry control transformer with ¾ A fuse and holder. Min, 50 VA), 4.5 Ohm resistor. 1 MOV 1 130V MOV 1 Test push button switch. 1 Flush mounted module For installation with more than 14 ohm total resistance special design consideration are recommended to suit customer requirements. Unless specified by the customer, the standard package for 120V input will be furnished. In a standard GM-300 Package, the MOV, control transformer, test button, 130V MOV, load resistor, fuse and fuse holder will be shipped loose. All components are to be installed and wired in the field by the customer in accordance with AMR drawing number 180-0096. This arrangement is provided to facilitate installation on customer s existing control panels where sufficient space may be available to install all components in on location. The resistor will be mounted at the load termination compartment. The MOV may be mounted in the cable terminating compartment of the switch-gear.

OPERATION Typical a schematic diagram of the GM-300 is shown on AMR drawing number 180-0096. Step by step operating procedures for the GM-300 are as follows; 1. Make sure all connections are correct. 2. For initial operation, disconnect external leads to the transformer secondary. Turn on 120V AC power supply and measure transformer secondary volts. This should read 24V AC = 10% to -20%. EXCESS VOLTAGE AT THIS POINT COULD DAMAGE THE GM-300! Turn off the 120V AC power supply and reconnect external secondary leads of transformer. 3. Turn balance knob counter-clockwise the way. Balance will now point to or read 4. 4. Turn on 120V AC power supply. The -1.5 OHMS light will be ON. The High CIRCUIT OHMS FAULT light will be blinking. Turn balance clockwise gradually until +1.5 OHMS light is ON. The minus light will stay ON. Note the reading on dial at the point where is cuts off the GM-300. With minus and plus light ON, continue to turn balance clockwise until the -1.5 light goes OFF. The Low Circuit OHMS FAULT light now will be blinking also. Note the balance reading at the cutoff point of minus light. Balance reading at minus light cutoff point is the total external resistance between the ground and pilot terminals of the GM-300 with all wires in place. The difference between the minus light cutoff point and the plus light cutoff point is the adjustment range window width of the GM-300. The value should be three (3) OHMS. When balance is set on the center of the window width, the CENTER light will be on (as well as the plus and minus lights). The CENTER window width is approximately on (1) OHM. This is the normal normally closed contacts will be closed when both the 1.5 and +1.5 lights are on, even thought the center lights will go off. Set balance desired sensitivity, CENTER light on. Refer to description on sensitivity.

If the output relay contacts are wired for proper circuit breaker operation the GM-300 is working. TEST SWITCH NOTE: The GM-300 is supplied with one (1) normally open and one (1) normally closed contact. See AMR drawing number 180-0096. The standard GM-300 package is supplied with a momentary pushbutton switch with one (1) normally open and one (1) normally closed contact. The normally closed contact is wired between the pilot wire and the pilot connection to the GM-300. This connection is a short wire connected to resistor R-A mounted on the rear of the GM-300 and for this reason the test switch should be mounted with in six (6) inches of the top the GM-300. The normally open contact is wired between the ground terminal and the pilot connection the GM-300. See AMR drawing number 180-0096. To test the GM-300, press the test push-button. As the normally closed contact breaks, the GM-300 will detect an open circuit, one PLUS LIGHTs go out, and the HIGH ohms light will blink; then the normally open contact will make and a 9 ohms test resistor will be connected in the circuit. Turn balance to 11, the MINUS LIGHTS will go out and the LOW ohms light will blink. While maintaining the push-button in the depressed position, re-position the selector knob to 9 ohms and push Reset button on upper center face plate. The HIGH and LOW lights should go out and the window light remains on. If this occurs, the GM-300 is functioning properly. SENSITIVITY Assume that a GM-300 has been placed in operation as described earlier, and a operating window width of 3 ohms is available. If the balance is set in the middle of the window with, the CENTER light on, the operating relay will drop out if the circuit resistance goes up by 1 ½ ohm or goes down by 1 ½ ohm. A one ohm drift is either direction will merely turn off the CENTER light without output relay operation. If the balance knob is set above the minus light cutoff point and the CENTER light is off, the relay will drop out it the circuit resistance goes down by ½ ohm or goes up by 2 ½ ohms.

GENERAL INFORMATION The indicating lights on the GM-300 are light emitting diodes with extremely long life and sharp cutoff point. These lights will not require replacement during the life of the GM-300. The GM-300 is designed for a window width of about 3 ohms. The window range is rated at 4 to 14 circuit ohms. Slight difference in window widths can be expected between various GM-300 units. This is due to component tolerances and will not affect the operation of the system. The circuit ohm is the total resistance of the following in ohms: Cable ground wire resistance Plus Pilot wire resistance Plus Contact resistance, if any. The GM-300 is field repaired down to the board level. Appendix B lists the assemblies that can be replaced. The LOW CIRCUIT OHMS light trigger point is meant to detect accidental pilot to ground shorts in the cable. The HIGH CIRUIT OHMS light tripper point is meant to detect an increase in ground circuit resistance, including the pilot wire circuit. When properly connected and operated, the GM-300 senses the external resistance between its ground and pilot terminals. This includes the resistance of the pilot wire, ground wire, and any other resistance in the electrical path of these wires, including bad connections, and contacts on relays, door switches, etc. Refer to AMR drawing 180.0096 The ground terminal should always be connected to cable ground close to the cable terminating point, by a separate insulated copper wire. The HIGH CIRCUIT OHMS light above the +1.5 light and the LOW CIRCUIT OHMS light above the -1.5 light are provided for trouble indication.

If the GM-300 trips out under high resistance conditions (including open pilot/ground circuit), the +1.5 light will go out and the HIGH CIRCUIT OHMS light will begin to blink. If the cause of high resistance disappears, the +1.5 light will come back on and the ground check system will become operational automatically. The HIGH CIRUIT OHMS light will continue to blink until the reset button is pressed. Typical examples of HIGHT CIRCUIT OHMS conditions are loose contacts or door interlocks, loose connections, bad ground or pilot wire splices, etc. The LOW CIRCUIT OHMS light operates similarly except that it si activated under low resistance condition. Typical example of LOW CIRCUIT OHMS condition is ground to pilot wire short circuit. OPTIONAL TRIP INDICATOR The trip indicator is mounted and pre-wired to the GM-300. The purpose of it is to indicate a trip even if power to the GM-300 is lost. To reset the indicator turn it clockwise until the flag disappears. OPTIONAL BATTERY If the optional battery (AMR #275-0007, 12VDC 12 amp/hour rechargeable or equivalent) is used in the system, the HIGH-LOW lights will provide indication for several hours even if the AC power is lost. TROUBLE SHOOTING Only a standard volt-ohm meter - such as Simpson, Triplett or similar meter - is required for normal field checking the trouble shooting on GM- 300 s. All readings indicated in this manual are based on a Simpson meter. Typical functions are reading s on various terminals of the GM-300 are as follows: GM-300 TERMINALS Case, (14) See Section General Information and refer Ground, (12) to AMR drawing number 180-0096. Pilot (Resistor R-A) Ground terminal is common with negative connection for battery (11) when optional battery is used. Test (13) For factory and field testing, see page 4, Test Switch.

TYPICAL TEST READINGS External Circuit Resistance Input Voltage (2), (3) Disconnect 120V AC power supply to the GM-300. Remove the external wires connected to ground and pilot terminals. Read resistance between the above to wires not the GM-300 terminals. The reading should be 4 to 14 ohms for the GM-300 to operate correctly. With the GM-300 connected to proper 120V power supply, the voltage across terminals (2) and (3) should be approximately 24V AC. This value can change between 19 and 26.5 volts without malfunction. This voltage should not drop below 19 volts even under machine start-up or other conditions. This voltage should not rise above 26.5 volts even at low power system load hours such as during nights or holidays. Output Contacts N.C. (14) N.O. (15) Common (6) One of the two 10A, 250V AC GM-300 output contacts should be wired into the system circuitry, such that if the GM-300 fails or a power failure occurs, The deenergized position controlled breaker tripping circuit will be N.C., breaker directly.

Battery Voltage Plus VDC (7) Minus VDC (11) Terminals (1), (8), (9), (10), (15), (16) DC input to GM-300. When the optional battery is used, automatic charging power for the battery is provided through the GM- 300 terminals (7) (+, red) and (11) (-, black). Normal reading between terminals (7) and (11) should be approximately 11.5 (+) or (-) 1 V DC, with battery disconnected. IF the battery is connected, this voltage will vary depending on the charge condition of the battery. No other readings are required of recommended in the field. Not for external use. PROBLEM / SOLUTIONS 1. No Lights Check connections. Check input voltage across plus VDC, minus VDC terminals. If no voltage or voltage to low, check input VA transformer and / or power supply fuse. Check 120 volt input source. 2. No PLUS LIGHT Perform TEST as outlined earlier on page 4. This will indicate if light is operative. Check external ground pilot circuit resistance. See Section Test Readings on page 7. If external circuit resistance is beyond GM-300 range. Contact AMR with complete cable data and length of cable. 3. No MINUS Light at 4 OHM Dial Setting Perform TEST as outlined earlier; this will indicate if light is operative. Check external circuit resistance as explained earlier. In case of troubles 2 and 3 above, disconnect external wires at GM-300 ground and pilot terminals. Check external ground/pilot circuit including parallel paths, door switches, coupler pins, connections, etc.

4. Nuisance Trips When Soil Gets Dry or Wet. GM-300 ground circuit is through natural earth and not through cable ground wire or bad connections on ground wire. Figure out total circuit resistance which can be expected by adding resistance of ground wires and pilot wire using simple resistance tables. If GM-300 dial reading at high cutoff point is considerably different from the above figure, double check cable ground and pilot wires. 5. Nuisance Trip During Hot and Cold Hours of Day (not dry or wet weather). This trouble is very infrequent and can be expected only under certain extreme ambient conditions in areas where the temperature differential between day and night will be in the range of about 40 degree F. or more. Contact AMR for further information. 6. Frequent GM-300 Failure at One Location. Made sure connection on ground terminals are per AMR drawing number 180-0096. on main substations where primary supply to the power transformer is received through overhead lines, GM-300 failures during storms may be caused by lightning discharges to the overhead phase conductors. Make sure all over head lines are protected by static wires or other means. Check all ground pits, electrodes and associated connections. 7. MOV Device Failure The MOV device is provided for protection against short time high voltage spikes. The MOV device will be damaged if subjected to extremely high voltages or voltages above its rating for longer periods, After power failures due to lightning storms or H.V. cable faults, check MOV devices for visible damage or discoloration. Normal resistance reading with a volt/ohm meter across an MOV device (disconnected) will be infinity. Routine inspection of the switch-gear equipment should include visually checking all MOV devices. 8. High/Low Lights Will Not Blink When GM-300 Trips Out and A.C. Power Supply to GM-300 Fails (Optional Battery). Check battery voltage and make sure that the battery is getting charged. (This is an optional feature).

9. Random Nuisance Trips If construction and welding activities are taking place in the areas of power distribution system, nuisance trips can occur for no apparent reason. Such nuisance trips take place due to welding currents returning through cable ground wires, giving false signal to GM-300. Under severe conditions, welding currents can be so high as to cause GM-300 burnout even though the circuitry is protected for this condition. Check if welding or similar operations are taking place in the distribution system area. Make sure sufficiently large return conductors are provided on all welding machines and take appropriate steps to prevent current returns through cable ground wire. Careful study of the physical layout of equipment and possible return paths may be necessary to eliminate this problem. 10. GM-300 Burns Out When AC Power Supply is Applied Disconnect terminals (2) and (3) wires from GM-300 and check boltage between the disconnected leads. If the voltage is within the limits specifed under Typical Test Readings, check voltage between wire (2) to ground and (3) to ground. If wire (2) to ground and/or wire (3) to ground reading is higher than 26.5 volts, check power supply, wiring and components. Typical troubles can be partial ground on primary, primary to secondary short circuit on ground check transformer, or underground main control power transformer or similar equipment. 11. GM-300 Shows Low Ohms for All Dial Settings Phase to pilot faults for sustained periods cause resistor R-A and/or R-B to open. With a load of 4 to 8 ohms a voltmeter will indicate approximately on (1) volt. Both R-A and R-B should measure 25 ohms. Should either resistor indicate fault, they may be replaced in the field. Contact AMR for these replacement parts.

SPECIFICATIONS Electrical 1. Input power: 120 VAC, +10%, _30% at ¾ amp 2. Control Relay Contacts: 250v A.C. at 10 amps 3. Indicators: -1.5, +1.5, High, Low, and Center Environmental 1. Operating Temperature: -20 degrees to +70 degrees C. (-4 degrees to +158 degrees F.) 2. Humidity: 0 to 90 percent R.H. Mechanical 1. Size: 9 ½ X 7 X 6 inches 2. Weight: 6 pounds

Appendix A TYPICAL OHMIC VALUES FOR POWER CABLE (Copper Conductor at 25 Degree C, 77 Degree F) Size AWG Max Ohms * or MCM per 1000 ft. 1000.0108 950.0114 900.0120 850.0127 800.0135 750.0144 700.0154 650.0166 600.0180 550.0196 500.0216 450.0240 400.0270 350.0308 300.0360 250.0431 0000.0509 000.0642 00.0811 0.102 1.129 2.162 3.205 4.259 5.326 6.410 7.519 8.654 10 1.039 12 1.652 14 2.626 16 4.176 * When two wires of the same size are in parallel, divide values given by two for total resistance. Example: Find total resistance of 1000 ft. cable with Two 4/0 Ground Wires and One No. 10 Pilot wire Resistance of ground wires.0509 2 =.02549 ohm Resistance of pilot wire = 1.039 ohm Total Resistance 1.06445 ohm

Appendix B Replacement Parts Ground Monitor PCB 253-0131 Front Panel Assembly 141-0068 Load Resistor (2 Per Unit) 018-6001 Varistor 009-0020 Varistor (130 Volt) 009-0003 Terminating Resistor 018-7001 Test Switch 270-0063 Transformer 130-0004 Fuse (3/4 Amp) 160-0004 Re-chargeable Battery 275-0007 (Optional)

WARRANTY AMERICAN MINE RESEARCH, INC. warrants that each product manufactured by it is free from defects in material and workmanship under normal usage and service. The obligation under this warranty shall be limited to the repair or exchange of any part or pars demonstrated to be defective; provided, such part or parts is returned to American Mine Research, Inc. s plant or to an authorized agent of American Research, Inc., within ninety (90) days after delivery of the product to the original purchaser; such return to be made at the sole expense fo the original purchaser. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, AND OF ANY AND ALL OTHER OBLIGATIONS OR LIABILITES ON THE PART OF AMERICAN MINE RESEARCH, INC. AMERICAN MINE RESEARCH, INC. NEITER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY LIABILITY OTHER THAN THIS WARRANTY IN CONNECTION WITH THE SALE OF ITS PRODUCTS OR ANY PART OR PARTS THEREOF. THIS WARRANTY SHALL NOT APPLY TO ANY PRODUCT OR ANY PART THEREOF WHICH HAS BEEN SUBJECT TO ACCIDENT NEGLIGENCE, ALTERATION, ABUSE, OR MISUSE, INCLUDING ANY PRODUCT OR ANY PART THEREOF ON WHICH THE SERIAL NUMBER HAS BEEN ALTERED, DEFACED, OR REMOVED. THIS WARRANTY SHALL FURTHER NOT APPLY TO ANY PRODUCT OR ANY PART THEREOF WHICH AS BENN CONNECTED, INSTALLED, OR ADJUSTED OTHERWISE THAN IN ACCORDANCE WITH AMERICAN MINE RESEARCH, INC. S INSTRUCTIONS AND/OR SPECIFICATIONS. American Mine Research, Inc. reserves the right to discontinue any product model at any time or to change specifications or designs at any time without prior notice and without incurring any obligation thereby.