TESTERLYZER Rack Mid / High V3.1 (E)

Similar documents
ADN PS. Power Supply. Instruction manual

Connecting a Cisco Output Module

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

ICCS Controllers Intelligent Control and Command Systems

5 B&W Rear View System Camera

Fredenstein Bento 10 Module Carrier

PO Box 409 Hanover, MD TEL (410)

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Quick Start Installation Guide

Fieldbus Gateway Type ME43

digiclip Data sheet DF31CAN Special features B en

digiclip Data sheet DF31DP Special features B en

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Orbis CU. Digital Control Unit Order # Optional CA-OR kit for 19" rack mounting front view

Owner s manual. SDAI 2175 Semi Digital Amplifier Integrated

HP4 headphone amplifier. user manual

MTeC - EPT202 Digital thermometer Messko

5000 Series Audio Matrix

Electrical Demand Specification (Reference SOP: )

selos The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

CLIPLINE complete. The modular terminal block system for all applications

Date Revision Change(s) 29/07/ First version

LED Commander 16/2 DMX controller. user manual

. Modular training system for the fundamentals of digital technology /. . Individual expansion possibilities. Detailed experiment descriptions

User Manual CTP64-Rotate

aentron Energy System 1 to 900 Vdc

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.

Model SAP612 Source Assign Panel User Manual

3950 NW 120 th Ave, Coral Springs, FL TEL FAX Ford A²B to 12-channel Analog & Digital sound processor NTV-KIT873

WELCOME TO THE FUTURE OF CONNECTION AND PROTECTION

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

Bento 6 DS Module Carrier

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

ELITE Test Systems. /Quick Start Wiring. Botron Company Inc.

Beckhoff PlugIn. August V

TSY 041 Training System Extension Motion

B&W RearView Camera Installation & Operation

MEASURING AND TESTING INSTRUMENTS

IST ULTRASTAB Power Supply for high precision transducers

LA-RAK II TOURING RACK

System Control Unit (SCU)

SoundwebTM. Installation Guide

AP 701 Access Panel. Features and Functions

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

K-Module 544 for: AS 43, AS 45, AS 200 IT. Installation Manual

HP8440 Power Box. The Intelligent Power Distribution Module. Installation and User Guide for PCM Version 9.02

Vehicle Intercom System

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

E-Learning, DC drives DCS800 Hardware D5 D7, part 2

Smart Monitoring System compact, secure, efficient

Luminaire testing device

C2-MMI2G-x. Compatible with Audi MMI 2G navigation systems

The Power to Log. Powerful Solution for Vehicle Testing and Validation of Automobile Networks

MULTIPOWER MANUAL. Designed and Manufactured by ITEC Tontechnik und Industrieelektronik GesmbH 8200 Laßnitzthal 300 Austria / Europe

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

DUAL MONO POWER AMPLIFIER INSTRUCTIONS FOR USE

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

TAPCON 250 DIGITAL ON-LOAD TAP-CHANGER CONTROLLER FOR VOLTAGE REGULATING TRANSFORMERS.

InForm Superstructures

EtherCAT P combines ultra-fast communication and power supply in a single cable

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

TAPCON 240 Voltage Regulator for Regulating Transformers

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition

DC POWER SUPPLIES DNX 110/220 V

Test & Measurement Solutions. Konrad Technologies Radolfzell, Germany

poly-planar Marine Audio System

TOA ELECTRIC CO., LTD.

sonnen Installation Practical

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

Specification Sheet: HT SERIES

Quasar Series Technical Features

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

PCAN-PC/104-Plus Quad Four-Channel CAN Interface for PC/104-Plus. User Manual. Document version ( )

INTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual

LP-STAR. Compact emergency lighting power supply with STAR technology Eaton, All Rights Reserved.

TELIKOU Intercom System

InForm Superstructures

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Achat 112 MA Achat 112 MA WH full-range speaker. user manual

Model KB 400 Cooling incubators with compressor technology

CS2000 Conference systems

Achat 110 MA active full-range speaker. user manual

TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability

TA18 active subwoofer. user manual

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

EMTRON AUSTRALIA EMTRON ECU OVERVIEW

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

HBAC-30. Owner s Manual. Battery powered Guitar Amp

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

Industrial relay system RIFLINE complete

16-Channel Digital Input Termination Card 24Vdc

IPEmotion_PlugIn_BECKHOFF_V01_05_00

Transcription:

TESTERLYZER Rack Mid / High V3.1 (E)

TESTERLYZER Rack Mid / High MOBILE RACK SOLUTIONS FOR YOUR COMPONENT TESTS IDEAL FOR ALL OEM TYPES. Control units of state of the art vehicle generations require complex interlinking of individual components for their functionality. As a result, control units are being tested more intensively in an integrated system. To meet this challenge, the TESTERLYZER Rack Mid / High provide a modular structure which ensures that control units can be integrated and tested in integrated systems defined by the developers.

LAYOUT OF CUSTOMIZED OPERATING PANEL (FRONT) Options: separate 12 V voltage tap for additional control units or measuring equipment taps for all busses required CAN / FlexRay to SUB-D Triggering option of terminal signals optionally manually via relay switch or automatically via integrated system control unit. All terminal statuses are displayed for constant and variable control via LED MOST Patchpanel provides facility for executing respective bus ring for 14 MOST control units +4 MOST reserve connections (MOST Logger) integration of customized OEM I/Os: microphones/customer access AUX or control units THE MODULAR PRINCIPLE Depending on respective customer requirements, circuit boards and interfaces can be combined on the side front panel. These include the following issues: Videopatch: All video sources and wells of the control unit environment can be freely interconnected or connected to external video signals/measuring equipment Audio switching: Via switches, loudspeakers integrated in the rear door of the cabinet can be connected to control units of the soundsystem equipment. 10 audio channels incl. peak display can be connected to or disconnected from the audio panel. The channels can be switched together either manually or automatically between loudspeakers/test sockets/load resistances. patches for Ethernet connection and antennae connections or CAN OPTIONAL TEST AUTOMATION power lines per level or control unit CAN lines closed current measurement operating current consumption MOST per control unit loudspeaker control additional variable lines for control units signal or automation tasks With upgrades: Bus short-circuit Bus interruption Bus short-circuit to ground Short-circuit current (control unit outlet)

BENEFITS AREAS OF APPLICATION flexible error analysis in development and series production simple replacement of components and control unit adapters minimal space requirement with high mobility industrial rack on rollers easy production of various equipment options development of control units (simple adaption, changing requirements) series production (guarantee of reverse compatibility by using cable adapters) integrated system test of hardware, firmware and software in series production quality management (error analysis, field returns, line errors product support FUNCTIONALITY The TESTERLYZER Rack Mid / High is a test environment comprising a range of components and assemblies. Basic equipment: 1 piece industrial rack with castors operating panel incl. Electrical interfaces (customized adaption) 1 extendable unit tray as laptop facility drawer to house measurement equipment and accessories. 2 / 4 extendable control unit levels 8 control unit connections are contacted on one circuit board per level, which ensure ideal signal distribution with minimal effect on the bus architecture. EQUIPMENT PER CONTROL UNIT CONNECTION automotive fuse 7.5 A / 10 A rocker switch Power On/ OFF incl. switching option from fixed to variable voltage source 4 banana jacks with short-circuit sensor bridge for (continuous) measurement of power consumption (Rest/Operation) 2 freely allocable rocker switches (two-pole) On/Off for individual signal deactivations coding plug for allocation of busses, signals and power supply per control unit 2 42-pole connectors The coding plugs and adapter cables for connection to the control units are included in the delivery packet. These are fully assembled by RUETZ TECHNOLOGIES after consultation with clients and delivered in line with the respective unit supplied. Option MID Up to 16 control units for 2 unit levels Option HIGH Up to 32 control units for 4 unit levels SIGNAL DISTRIBUTION PER CONTROL UNIT CONNECTION 5 CAN Bus (drilled wire in accordance with specifications) 30 signals freely allocable, max. 3 A capacity 8 power lines for voltage taps (configurable in line with automation tasks) Kl30, Kl30 variable Kl15 Other bus connections per control unit level: (4 levels) 1 FlexRay Bus tape with OEM standard line on Sub-D 6 Most-Bus connections to operating panel for manually connectable bus topology (optional with connection to MOST Switch/ Matrix) Video Bus with 12 shielded lines à 75 Ohm to SMB jacks. Lines interconnected from level to level (optional) Audio-Bus with 20 pole (with 10 A capacity each) lines interconnected from level to level (optional)

MOBILE RACK SOLUTIONS FOR YOUR COMPONENT TESTS IDEAL FOR ALL OEM TYPES. TECHNICAL DATA Dimensions W H D 1000/800 1900 800 mm Weight ca. 150 kg empty Primary voltage 90 240 V, 50 60 Hz, 2,0 A Secondary voltage 3 16 V DC, 16 A fused 40 A 13,8 V DC / 4 A; 13,8 V DC / 35 A Protection Type IP 20 YOUR CONTACT PARTNER We are available to provide support and advice at all times please contact us to arrange a meeting! Carsten Dörr Key-Account T +49 / 89 / 3 56 10-150 carsten.doerr@ruetz.de Andreas Grey Sales T +49 / 89 / 3 56 10-175 andreas.grey@ruetz.de RUETZ TECHNOLOGIES GmbH Walter-Gropius-Strasse 17 80807 München Germany T +49 / 89 / 3 56 10-0 F +49 / 89 / 3 56 10-111 www.ruetz.de info@ruetz.de Managing Director: Stefan Ruetz Registry court München HRB 87510