Similar documents
General Specifications. P2-SCM Serial Communications

P3-RS Remote Slave. Remote Slave Specifications. The P3-RS is a full-featured, highperformance,

P3-RS Remote Slave Module

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

P USB 2.0 (Type B) Port - Programming - Online monitoring

P2-HSO High-Speed Isolated Sinking/Sourcing Output. Connector Specifications

P3-530 CPU. CPU Specifications. The P3-530 is a high-performance CPU for use with the Productivity3000 Programmable Automation Controller.

P1-540 CPU. CPU Specifications

P2-16AD-2 Analog Input. Connector Specifications

P2-04DA Analog Output. Removable Terminal Block Specifications

General Specifications. P2-8AD4DA-2 Analog Input/Output

General Specifications. P2-08THM Analog Input

P2-04AD Analog Input. Removable Terminal Block Specifications

General Specifications. P2-08NTC Thermistor. The P2-08NTC module provides eight Thermistor input channels for use with the Productivity2000 System.

P3-08RTD Analog Input

T1K MODBUS Base Controller Specifications

Removable Terminal Block Specifications

Digital ac/dc (24V) Input Module

CompactBlock Guard I/O EtherNet/IP Safety Modules

EH-RIO IP67 Profibus-DP I/O modules

Do-more H2 Series PLC System Specifications

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

TXP3500/4000 Series AC-DC Industrial PSU

ArmorPoint I/O Field Potential Distributor, Series A

Analog Voltage Combination Module

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

ControlNet-to-DeviceNet Linking Device

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

TF501, TF521 Terminal Bases

D2 RMSM/ T1K RSSS Remote I/O System

CM597 Ethernet Communication Module

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

TU531, TU532 Terminal Unit

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

AI531 Analog Input Module

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

GFK-2415A March Type of sensor connection

The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

Digital ac/dc (24V) Input Module

Installation and Setup

PACSystems* RX3i IC695CMM002 and IC695CMM004

Isolated 24V dc Output Module

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

PACSystems* RX3i IC695CMM002 and IC695CMM004

CM592 PROFIBUS Communication Module

TEP 100WIR Series, 100 Watt

Rhino PSM Power Supplies. Operating Instructions

GE Fanuc IC695CMM004. Rx3i PacSystem

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

A general-purpose industrial input/output

TM241CE24T controller M IO transistor PNP Ethernet

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

AO523 Analog Input Module

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

AX522 Analog Input/Output Module

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

PanelView Plus/VersaView CE Terminals and Display Modules

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

TM241CE40R controller M IO relay Ethernet

TM241C40U controller M IO transistor NPN

Serial Communication Converters & Adapters Instruction Manual

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CE40R controller M IO relay Ethernet

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

TM241C24T controller M IO transistor PNP

TM241CE24U controller M IO transistor NPN Ethernet

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

CM579-PNIO PROFINET Communication Module

RS485 3 click. How does it work? PID: MIKROE-2821

General information. Display. Supply voltage. Input current

FL MC 2000E (SM40) LC

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Carbon Monoxide Sensor - ModBus

TM241CE40R controller M IO relay Ethernet

TM241C40R controller M IO relay

APPENDIX B SERIAL I/O MODULE INSTALLATION / OPERATION WHEN USING T&D VER. 5.2 OR 5.3

PCI Express 4-Port Industrial Serial I/O Cards

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

CM589 PROFINET Communication Module

onlinecomponents.com

TM241CE24T controller M IO transistor PNP Ethernet

Embedded I/O Expansion Board with 10 Outputs

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

H704-42(H)(E), H704-42/1(H)(E)

1756 ControlLogix Chassis Specifications

TM241CE40T controller M IO transistor PNP Ethernet

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

Environmental Specifications CompactLogix Controllers and Compact GuardLogix 5370 Controllers

CI504 PROFINET Communication Interface Module

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Transcription:

General Specifications Module Type Modules per Base Modules per Group I/O Points Used Field Wiring Connector Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Noise Immunity Emissions Agency Approvals Module Location Weight Intelligent Base size limited, 11 Max 11 Max None, mapped directly to tags in PAC 4 - RJ12, 1-4 Position Terminal Block 0 to 60 C (32 to 140 F) IEC 60068-2-14 (Test Nb, Thermal Shock) -20 to 70 C (-4 to 158 F) IEC 60068-2-1 (Test Ab, Cold) IEC 60068-2-2 (Test Bb, Dry Heat) IEC 60068-2-14 (Test Na, Thermal Shock) 5 to 95% (non-condensing) IEC 60068-2-30 (Test Db, Damp Heat) No corrosive gases permitted (EN61131-2 pollution degree 1) IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) None No Isolation NEMA ICS3-304 IEC 61000-4-2 (ESD) Impulse 1000V @ 1µS pulse IEC 61000-4-4 (FTB) RFI, (145MHz, 440MHz 5W @ 15cm) IEC 61000-4-3 (RFI) EN61000-6-4 (Conducted and Radiated RF Emissions) UL508 file E157382, Canada & USA CE (EN61131-2007) Any slot in any local, expansion or remote base in a Productivity3000 System 260g (9oz) Document Name Edition/Revision Date -M 1st Edition/Rev. D 11/20/2017 Copyright 2017, AutomationDirect.com Incorporated/All Rights Reserved Worldwide. P1 P4 5V, PORT 2 PORT 3 The is a serial communications module capable of Modbus, ASCII, and Custom Communication Protocols and able to power the C-More Micro through (Port 1 only) for use with the Productivity3000 Programmable Automation Controller. General Specifications...1 SCM Front Panel...2 Module Installation Procedure...2 Port 1 Powers C-More Micro...3 Configuration Options...3 Specifications Port 1, 2, 3, & 4...4 Line Specifications for Ports...4 Port 1 Specifications...5 Port 2, 3, & 4 ( Configuration)... 5 Specifications Port 4...6 Line Specifications for Port 4...6 Port 4 ( Configuration)...7 Port 4 LED Behavior...7 Removable Terminal Block Specifications...7 Cable Options...7 Safety Information...8 Hot Swap Information...8 Diagnostic LEDs....8 Firmware/Software Requirements...8 Warranty: Thirty-day money-back guarantee. Two-year limited replacement. (See www.automationdirect.com/000 for details). Sales 800-633-0405 www.automationdirect.com/000 1

P1 P4 5V P1 P4 5V PORT 2 PORT 3 Front Panel Module Installation Procedure P1 P4 5V, STATUS DISPLAY - 16 LEDS - Shows communication status for each port Step One: Align circuit card with slot and press firmly to seat module into connector. PORT 2 PORT 3 WARNING: Do not apply field power until the following steps are completed. PORT 2/3 - PORT 2 - - Provides 5V, 210mA power for the C-More Micro Step Two: Pull top and bottom locking tabs toward module face. Click indicates lock is engaged. PORT 3 - Software Configurable - or WARNING: Explosion hazard Do not connect or disconnect connectors or operate switches while circuit is live unless the area is known to be non-hazardous. Do not hot-swap modules unless the area is known to be non-hazardous. 12 www.automationdirect.com/000 Tech Support 770-844-4200

Port 1 Powers C-More Micro DV-1000CBL Serial Cable. 5V P1 P4 R PORT 1 RS PORT2 PORT3 Port 1 has 5 volts available to power AutomationDirect C-More Micro Panel (Monochrome only). Configuration Options Configuration Item Port 1 () Ports 2, 3 & 4 () Port 4 (when ) Protocol Selections Disabled, Modbus Disabled, Modbus Disabled, Modbus RTU, ASCII/Custom RTU, ASCII/Custom RTU, ASCII/Custom Data Rate 1200, 2400, 4800, 9600, 19200, 33600, 1200, 2400, 4800, 9600,19200, 33600, 1200, 2400, 4800, 9600,19200, 33600, Parity None, Odd or Even None, Odd or Even None, Odd or Even Data Bits4 7 or 8 Bit 7 or 8 Bit 7 or 8 Bit Off Delay Time 1 0-5,000 msec On Delay Time 1 0-5,000 msec Modbus Character Timeout 2 0-10,000 msec Communication Timeout (Timeout between query and response) Response/Request Delay Time 0-5,000 msec 0-5,000 msec 0-10,000 msec 1 For None selection with Modbus RTU protocol, Modbus.org minimums are used. This minimum is 3.5 character times up to 19, 200 baud rate and 1.75 ms over 19,200 baud rate 2 Only applies to MODBUS messages 3 signal is only provided on Ports 2, 3 & 4 4 7-bit data are only supported with Odd or Even parity Sales 800-633-0405 www.automationdirect.com/000 13 0-10,000 msec 100-30,000 msec 100-30,000 msec 100-30,000 msec 1-5,000 msec Comm Heartbeat 2-1,000 sec 2-1,000 sec 2-1,000 sec Value 2 Node Address (Station) 1 to 247 1 to 247 1 to 247 Ignore, Wait, System Input 3 Enable/Disable Wait Timeout Enable Timeout, Disable Timeout (Never Timeout) Wait Timeout 100-999,900 msec On, Off, Assert During Transmit, On, Off, Assert During Transmit, System Output System Output Port 4 2-Wire Mode Disable, Enable MODBUS Port Security Read/Write, Read Only Read/Write, Read Only Read/Write, Read Only

Port Specifications Ports 1, 2, 3, & 4 Electrical Specifications Min Typ Max Units Output ON, Space Condition (3kΩ, 5.0 5.2 Volts 1000pF Load) Output OFF, Mark Condition (3kΩ, -5.2-5.0 Volts 1000pF Load) Output Short-Circuit Current 15 ma Short-Circuit Duration No Limit Seconds Output Resistance 300 Ohm Input ON Threshold 1.6 2.4 Volt Input OFF Threshold 0.6 1.2 Volt Input Resistance 3k 5k 7k Ohm Line Specifications for Ports Line Specifications Data Rate Setting Options 1200,2400,4800,9600,19200, 33600, Units BAUD Data Rate Error ±2 % Data Bits Setting 1 7 or 8 Bits Stop Bits Setting 1 Bits Parity Setting None 1, Odd or Even Parity Data Transmission Half duplex or Full duplex 2 Network Point-to-Point 1. 7-bit data are only supported with odd or even parity 2. Full duplex is only supported for ASCII/Custom Protocol 14 www.automationdirect.com/000 Tech Support 770-844-4200

Port Specifications Port 1 Configuration Port Name Description Data Rates +5V Cable Power Source D D GND Maximum Output Load (D/) Minimum Output Voltage Swing Output Short Circuit Protection Port Status LED Non-isolated DTE port connects the CPU as a Modbus/ASCII master or slave to a peripheral device. Includes ESD and built-in surge protection. Selectable,1200, 2400, 4800, 9600, 19200, 33600, and 38400. 210mA maximum at 5V, +/- 5%. Reverse polarity and overload protected. Transmit output Receive input Handshaking output for flow control. Logic ground 3kV, 1,000pf +/-5V +/-15mA Red LED is illuminated when active for D, D and Port 2, 3 and 4 ( Configuration) Port Name Description Non-isolated DTE port connects the CPU as a Modbus/ASCII master or slave to a peripheral device. Includes ESD and built-in surge protection. Data Rates Selectable,1200, 2400, 4800, 9600, 19200, 33600, and 38400. D Transmit output D Receive input Handshaking output for flow control. Handshaking input for flow control. GND Logic ground Maximum Output 3kV, 1,000pf Load (D/) Minimum Output +/-5V Voltage Swing Output Short +/-15mA Circuit Protection Port Status LED Red LED is illuminated when active for D, D and 6 1 6-pin RJ12 Female Modular Connector Pin # Signal 1 GND Logic Ground 2 +5V 210 ma Maximum 3 D Input 4 D Output 5 Output 6 GND Logic Ground 6 1 6-pin RJ12 Female Modular Connector Pin # Signal 1 GND Logic Ground 2 Input 3 D Input 4 D Output 5 Output 6 GND Logic Ground Sales 800-633-0405 www.automationdirect.com/000 15

Port 4 Electrical Specifications Min Typ Max Units Driver Differential Output (60Ω load) 1.5 Volts Driver Common-Mode Output 3 Volts Driver Short-Circuit Output Current 250 ma Short-Circuit Duration (Thermal Shutdown) No Limit Seconds Receiver Differential Input Threshold 200 mv Receiver Common-Mode Input -7.5 12.5 Input Resistance 12k Ohm Termination Resistance (TB jumper wire T to + ) Cable Length (38400 BAUD max.) 120 Ohm 1200 Meter Line Specifications for Port 4 Line Specifications Data Rate Setting Options 1200,2400,4800,9600,19200, 33600, Units BAUD Data Rate Error ±2 % Data Bits Setting 1 7 or 8 Bits Stop Bits Setting 1 Bits Parity Setting None 1, Odd or Even Parity Data Transmission Half duplex 1. 7-bit data are only supported with odd or even parity G - + T 16 Install Jumper between T and + to terminate network node. * Jumper not included www.automationdirect.com/000 Tech Support 770-844-4200

Port 4 ( Configuration) Port Name Description Data Rates D+/D+ D-/D- GND Input Impedance Maximum load Output Short Circuit Protection Electrostatic Discharge Protection Electrical Fast Transient Protection Minimum Differential Output Voltage Fail safe inputs Maximum Common Mode Voltage Port Status LED Cable Options Non-isolated port connects the CPU as a Modbus/ASCII master or slave to a peripheral device. Includes ESD/EFT protection and automatic echo cancellation when transmitter is active. Selectable, 1200, 2400, 4800, 9600, 19200, 33600, 38400 transceiver high transceiver low Logic ground 19kV 50 transceivers, 19KV each, 60V termination (2 120V Resistors @ each end) +/- 250mA, thermal shut-down protection +/-8KV per IEC1000-4-2 +/-2KV per IEC1000-4-4. 1.5V with 60V load Logic high input state if inputs are unconnected -7.5V to 12.5V. Red LED illuminated when active for D and D Recommend L19827-100, L19827-500, L19827-1000 or Belden #9841 Port 4 LED Behavior Port 4 RS232 1 2 3 3 RS485 1 2 3 4 1 - Flickers on D activity, OFF when idle 2 - Flickers on D activity, OFF when idle 3 - ON when asserted, OFF otherwise 4 - Always OFF Removable Terminal Block Specifications Number of Positions Wire Range Screwdriver Size Screw Torque 4 Screw Terminals, 3.5MM Pitch 16-28 AWG Solid/Stranded Conductor Use Copper Conductors, 75 C or Equivalent TW-SD-VSL-1 (recommended) 0.4 N-m Removable Terminal Connector included. Spare connectors available (part no. -RS485CON-1). G - + T Pin # Signal G GND D-/D- + D+/D+ T TERMINATION Cable Options Recommended Recommend L19827-100, L19827-500, L19827-1000 or Belden #9841 Sales 800-633-0405 www.automationdirect.com/000 17

WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call Technical Support at 770-844-4200. This publication is based on information that was available at the time it was printed. At AutomationDirect.com we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. Diagnostic LEDs LED Port 1 Port 2 Port 3 Port 4 D X X X X D X X X X X X X X X X X 5V X 1 - All RS232 & RS485 LEDs reflect the actual electrical level of the signal, there is no direct firmware control of LEDs 2 - RS232 LEDs D, D, & are turned ON when their voltage on the RS232 wire is postive (MARK) a - This occurs when the UART I/O signal is low (GND) b - They are turned OFF when the voltage on the RS232 wire is negative (SPACE) 3 - RS485 LEDs D, D, & are turned ON when the UART I/O signal is low (GND) 4-5V LED is ON when 5V power is good, 5V LED is OFF when 5V is shorted to ground Important Hot-Swap Information The Productivity3000 PAC supports hot-swap! Individual modules, expansion bases, and entire remote base groups can be taken offline, removed, and replaced while the rest of the PAC system continues controlling your process. Before attempting to use the hot-swap feature, be sure to read the hot-swap topic in the programming software s help file or our online documentation at AutomationDirect.com for details on how to plan your installation for use of this powerful feature. CPU Firmware Required Productivity Suite Required -530 Version 1.1.15.x or later Version 1.10.x.x or later -550 Version 1.1.15.x or later 18 www.automationdirect.com/000 Tech Support 770-844-4200