Digital Level Sensor. Consistent accuracy, unparalleled reliability. Answers for energy.

Similar documents
Model 3005 Analog Board. User s Guide

Family of Water Cut Analyzers

TPE 1464 Series Pressure Transducer

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

5020 Modbus Translator. User s Guide

4110 HART Level Encoder

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Level Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

LPG STM 94442A User s Manual

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Level Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

Level-Lance Model 5400A

MMT330 Series Moisture and Temperature Transmitters for Oil

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

SITRANS L Level instruments

Digital Indicator Solutions

HIGH-VOLTAGE DC METER

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

High Voltage DC Meter

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. Accessories Catalog

Multiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual

Level Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Accessories for liquid level transmitters Catalog

Self-Powered Wireless Instrumentation

Trident and Trident X2 Digital Process and Temperature Panel Meter

OPERATING INSTRUCTIONS

NF770 Temperature Compensation Liquid Flow Computer

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

DXp-10 and DXp-15 Weight Transmitter

8130 Remote Terminal Unit

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

L&J engineering s Wireless Systems. Wireless Level Gauging. company

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

ZFM ZFM DIGITAL MASS FLOW METER

2900 Float & Tape Transmitter

IS-3000-LS-ABB INFRARED SCANNER

CDD4 Duct Carbon Dioxide Transmitter

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology. Liquid-Level Transmitter Accessories Catalog

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

Differential Liquid/Gas Pressure Transmitter

NEMA 4X. Wireless Technologies USA Witech USA Corp

A C C S for Road Tunnels. NOVICOM CO/NO/Visibility Monitor Contact us for Information about:

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

4000 Advanced Technology Transmitter

MODEL 8000MP LEVEL SENSOR

2910 Float & Tape Transmitter

Process & Temperature Digital Panel Meter

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

PD765 TRIDENT. Trident Series Process & Temperature Meters.

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

Dräger REGARD 7000 Control System

Carbon Monoxide Sensor - ModBus

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

BLISS ANAND. BA-Series Magnetostrictive Level Transmitter

Page 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide

Explosion-Proof Gauge Pressure Transmitter

CDD Carbon Dioxide Transmitter

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Micro Motion Model 7950 and Model 7951 Signal Converters

DXP-40 FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

Installation and Operating Instructions

CII: Current Input, Isolated

NEMA 7. Wireless Technologies USA Witech USA Corp

Houston Digital Instruments, Inc. Product Catalog

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

Compact Telecontrol System TM 1703 mic. SICAM 1703 flexible for all applications. Answers for energy.

Thermo Scientific CM515 and HME900 Density Converter Electronics

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

icountpd Online Particle Detector

Scanner 2000 microefm

DPM DPM MULTI PARAMETER - MULTI GAS MASS FLOW METER

DPC DPC PRECISION DIGITAL MASS FLOW CONTROLLER WITH MULTI-GAS FUNCTIONALITY

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

Thermocouple Input Module Product Specifications and Installation Data

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

D/E Remote Relay Panel User Guide

Installation & Operation Manual

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Siemens BACnet Programmable TEC Constant Volume

SCADAPack Smart RTU

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

SCADAPack Modbus multivariable transmitter

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

APP 700 Technical Specification

EC700. Pulses concentrator. User instructions

Transcription:

Digital Level Sensor Consistent accuracy, unparalleled reliability Answers for energy.

2 Consistent accuracy Unparalleled reliability

The Siemens Digital Level Sensor (DLS) is an engineered solution for remotely monitoring liquid levels in storage tanks. In addition to offering true digital level measurement in precise increments, it accurately and repeatedly measures two different fluid densities and up to eight temperatures on the same sensor. Its accuracy is maintained over the entire life of the sensor, thereby helping to reduce long-term maintenance costs. 3

Standard features, applications, benefits Intrinsically safe apparatus approved to meet UL913 standard for safety Low maintenance Temperature changes do not affect accuracy, unlike many other level sensing devices Applications include production monitoring, inventory control, leak detection, remote read-out of level in H2S environment, high/low alarms and many other applications All electronics are sealed inside the sensor tube Sensor tube available in stainless steel and fiberglass Intrinsically safe apparatus when connected to RLD model 1010 barrier board ETL-approved intrinsically safe barriers available to mount with the RTU Field wiring that connects to a surgeprotected fuse board shielding the sensor electronics from lightning damage Proven for use in many different fluids and environments, including crude oil, water, diesel, kerosene, condensate and gasoline Explosion-proof junction box suitable for connecting to rigid conduits Standard ASCII protocol for communicating with several existing remote terminal units via RS485/RS232 Digital-to-analog conversion available for outputting either a 4-20mA or 1-5 VDC analog signal 4

Model 1000 Digital Level Sensor specifications Measurement length Available from 2 to 30 in 1 increments Longer sizes available as custom orders Tubing material 316L stainless steel: standard 18 gauge: standard 14 gauge: optional Fiberglass: optional Float NYTROPHYL stainless steel: standard UHMW-NYTROPHYL: optional One standard, two optional for water interface Fits either 3 or 4 tank ports Level measurement increments and accuracy Standard 1/4 resolution (+/- 1/8 accuracy) 1/2 resolution (+/- 1/4 accuracy) Operating temperature range -40 F to +185 F: standard -40 F to +240 F: optional Power requirements 12 VDC +/- 15% at sensor terminals Power consumption 45mA nominal 70mA maximum Pressure 15 psi: standard Higher pressure ratings available as custom orders Communication RS485 Two- or four-wire communications Baud rate and parity programmable (up to 38400 baud) 4-20mA signal available when connected to digital-to-analog converter board Wiring Two-wire communication: two twisted pair, (16-18 AWG) recommended Four-wire communication: three twisted pair, (16-18 AWG) recommended Temperature measurement Display of F: standard First sensor 12 from bottom: standard 1-8 temperature sensors available with desired spacing: optional +/-.5 F accuracy 5

Model 1000 terminal unit The Model 1000 terminal unit is a solidstate stand-alone device designed to read the digital signal from the Model 1000 Digital Level Sensor (DLS) and convert it to an analog output. The intent is to enable the superior accuracy of the Model 1000 DLS to be used in a system that has only analog inputs available for receiving tank level data. This unit can poll up to 16 individual Model 1000 DLS units and output up to eight analog signals based upon data received from the Model 1000 DLS. The analog outputs are user programmable for either level or temperature from a particular sensor. Each analog loop can be set up to either source power or be powered by the host unit. This unit is programmable through a standard RS232 serial cable with RTS/CTS connected to a computer running the Model 1000 terminal configuration software or any terminal emulation software. Local readout for the tank levels and temperature are available with a four-line by 20-character LCD display. It will display up to two levels, temperature and tank volume for each tank. Sockets are provided for two optically isolated G4 digital output modules for alarming or controlling based on user programmable set points for any sensors. The G4 modules can control either AC or DC power to dry contact relays. An expansion board has been developed to allow for eight additional optically isolated G4 digital output modules. With this expansion board, a total of 10 digital outputs are available. 6 Mechanical specifications NEMA 4X enclosure Optional eight D/O expansion board can be mounted inside enclosure Electrical specifications Operating temperature range: -40 C to +85 C When equipped with LCD display, operating temperature is 0 C to 70 C Optional display heater for cold operating conditions Power requirements: 12 to 15 VDC Power consumption Standby without display: 75mA* Standby with display: 85mA* During scroll - LCD backlight: 210mA* (scrolling period is programmable) During poll: 100mA* (polling time = 2 sec max) Sleep mode: 9mA** Analog outputs: 20mA max per channel if unit sources loop power *Power consumption does not include connected level sensors. User must consider each sensor connected will draw an average 45mA. **Sleep mode is designed for stand-alone display applications with no digital or analog outputs programmed. RS232 port Provided for configuration and diagnostics 9600 baud, no parity, eight data bits, one-stop bit Communication: HyperTerminal or similar terminal emulation software using ASCII commands Configuration software available RS485 port Communication to the Model 1000 DLS Four-wire communications Cycles power to level Model 1000 DLS between polls 4-20mA conversion accuracy (except as limited by sensor and protocol resolution) Resolution: 16 bit Monotonicity: 16 bit min Integral non-linearity: +/- 0.01% of FS max offset (4mA) at 25 C +/- 0.1% of FS max Offset drift: +/- 25 ppm of FS/ C max Total output error: (20mA) at 25 C +/- 0.2% of FS max Total output drift: +/- 50 ppm of FS/ C max VCC supply sensitivity: 50 ma/mv typical Optional digital outputs Total of 10 output sockets available Two sockets provide for optically isolated G4 modules on board (G4 modules sold separately) Eight additional sockets with expansion board

Model 1000 four-channel output board Model 3005 analog board DAC4 The DAC4 is a solid-state stand-alone interface board that polls the Model 1000 DLS and outputs a 4-20mA analog signal for use by other field data collection equipment. The intent is to enable the superior accuracy of the Model 1000 DLS to be used in a system that has only analog inputs. The interface board can poll up to four Model 1000 DLS and output up to four analog signals based upon data received from these sensors. Not all analog channels need to be used. The analog signal can output the level or temperature data from a particular sensor. Electrical specifications Operating temperature range: -40 C to +85 C Power requirements: 12 to 15 VDC Power consumption Standby: 38mA During poll: 145mA* (polling time = 2 sec max) Analog outputs: 20mA max per channel if unit sources loop power *Power consumption does not include connected level sensors. User must consider each sensor connected will draw an average 45mA. RS232 port Provided for configuration and diagnostics 9600 or 1200 baud communicates using HyperTerminal or similar terminal emulation software using ASCII commands RS485 port Communication to the Model 1000 DLS Two- or four-wire communications Cycles power to Model 1000 DLS between polls 4-20mA conversion accuracy (except as limited by sensor and protocol resolution) Resolution: 16 bit Monotonicity: 16 bit min Integral non-linerarity: +/- 0.01% of FS max Offset (4mA) at 25 C: +/- 0.01% of FS max Offset drift: +/- 0.25 ppm/ C Total output error: +/- 0.2% of FS max Total output drift: +/- 50 ppm/ C VCC supply sensitivity: 50 ma/mv For any specifications not listed above, please see the specifications listed under the Model 1000 terminal unit. The Model 3005 is designed to provide a single analog output from the Model 1000 DLS. It provides a 4-20mA signal output for the total fluid level of the tank. This is an alternative to the Model 1000 terminal unit. It is intended for locations requiring an analog signal for the tank level where only one or two tanks are on location. The Model 3005 replaces the fuse board in the explosion-proof housing on top of the Model 1000 DLS. It provides the same protection to the Model 1000 DLS as the fuse board provides. The Model 3005 requires 24 VDC and controls power to the level sensor. It powers the sensor on a preprogrammed schedule, polls for the level analog value, powers the sensor down and outputs the analog signal. The configurations for the Model 3005 are stored in the EEPROM of the Model 1000 DLS, allowing for replacement when required. Electrical specifications Operating temperature range: -40 C to +85 C Power requirements: 24 VDC +/- 10% Requires 125mA max Requires two wires for power and two wires for 4-20mA loop 4-20mA conversion accuracy (except as limited by sensor and protocol resolution) Resolution: 16 bit Monotonicity: 16 bit min Integral non-linearity: +/- 0.012% max Offset: +/- 0.05% max Total output error: +/- 0.15% max 7

Published by and copyright 2009: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens Energy, Inc. Oil and Gas Division 10730 Telge Road Houston, TX 77095 1 (888) 856-4528 or +1 (281) 856-4530 Order No. E50001-D440-A123-X-76US Printed in USA BU 200954165426424T BR 0609.25 All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract. www.siemens.com/energy