BACnet Controller for General-purpose Building Applications

Similar documents
Advanced Remote I/O Module

Infilex AC AHU Controller Model WY5317C

SCS (System Core Server) Model BCY44100M

Infilex GD Multipurpose Data Gathering Panel Model WY5310

Infilex GC Multipurpose Controller Model WY5311

Infilex AC. Air Handling Unit Controller for NC-bus Communication. Specifications/Instructions. General. Features AB-6438

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

DMT345 and DMT346 Dewpoint Transmitters

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

mark150s mark150/485s DDC controllers Summary

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

FEATURES DESCRIPTION SPECIFICATIONS

MCX08M2 Programmable controller

Andover ContinuumTM. b3850 Series Terminal Controllers

Hotel Room Controller

TALON Network Manager- 2 & 6 Express

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

FEATURES DESCRIPTION FEATURES

BACnet. b3867 Terminal Controllers

Andover ContinuumTM Infinet II

BACnet. b3810 Series Local Controllers

Datasheet. ECB-600 and ECx-400 Series. ECB-600 & ECx-400. Overview. Applications. Features & Benefits.

DIGITAL INDICATING CONTROLLER

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

LBVR1718. Description. Features channel paperless recorder

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

PARAMATRIX 4 Chiller Controller

I/O Modules, User Terminal Module, and SAnet Interface Module

iothinx 4500 Series (45MR) Modules

General information. Display. Supply voltage. Input current

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

AIAS. Technical description

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Select a Micro800 Controller

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

Climatix programmable controller

PTU300 Combined Pressure, Humidity and Temperature Transmitter

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage

Specification Sheet For electronically commutated motors

TC Compact Series Unitary Equipment Controller

Paperless Recorder VGR-B100. Series

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Andover ContinuumTM Infinet II

Monitoring various parameters with one power meter!

General information. Display. Supply voltage. Input current

Saved Data playback Saved data in Memory card can be easily called out and played back on display

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Infilex GC Multipurpose Controller Model WY5111

IMIO100 IMIO105. DDC controllers. Summary

General information. Display. Supply voltage. Input current

Measurement Systems Datascan Installation and User Guide

ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085

Compact data logger offering best-in-class noise resistance and communication function

Datasheet. ECB-300 Series. 1/6. BACnet B-AAC 18-Point Programmable Controllers. Overview

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Enhanced communication

AB Axis Industries. Use

PAPERLESS RECORDER OUTLINE FEATURES SPECIFICATIONS. Easy operation with touch panel providing an intuitive user interface

TAC Xenta 301. Controller, Freely Programmable

MCX06C Programmable controller

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

iologik E1200H Series

Part Number Total I/O Power Voltage Input Voltage Output Type Maximum Digital I/O Maximum Analog I/O V AC Relay 24V DC.

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

ECB-300 Series BACnet B-AAC 18-Point Programmable Controllers

CBX System. CBX System TECHNICAL DATASHEET & INSTALLATION GUIDE DESCRIPTION APPLICATION

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Process displays For current and voltage

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

PXR Series Advanced Self-Tuning Temperature and Process Controllers

RS232C/RS485 Data can be easily monitored by LAN

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Millenium II +: general characteristics

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

General information. Display. Supply voltage. Input current. Encoder supply. Output current

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

General information Engineering with Programming package. Display with display

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Transcription:

Specifications BACnet Controller for General-purpose Building Applications General Model WJ-1101 is the BACnet controller to be used for a wide range of building applications such as air-conditioning and plumbing. Model WJ-1101 provides excellent controls suitable for your building with scalable inputs and outputs (I/Os) and configurable control applications. s () and control applications can be added to Model WJ-1101 for a change in operation or for a retrofit, offering high extensibility. Features Open protocols for high connectivity: Model WJ-1101 supports BACnet/IP. Its RS-485 communication allows to connect BACnet MS/TP, Modbus ASCII, and Modbus RTU devices. Modifiable I/O combinations: Model WJ-1101 has 24 I/Os including universal inputs (UIs) for inputs of current, voltage, resistance (Pt100 Ω/Pt1000 Ω), and open collector. Besides these I/Os, Model WJ-1101 accepts up to 20 I/O modules () in any combination through the Ethernet connection. s away from Model WJ-1101: Ethernet connection enables to leave distance between s and Model WJ-1101. s mounted near field equipment thus accessible to Model WJ-1101. Visible I/O status: The LEDs of Model WJ-1101 for digital inputs (DIs), digital outputs (DOs), and UIs show the status of the feedback input from field equipment and the on/off output to field equipment. Controls configured for your instrumentation: To fulfill the instrumentation requirements of your building, Model WJ-1101 provides temperature and humidity controls and energy-saving operations through CO2 control, outdoor-air cooling control, etc. Control applications added and modified during operation: Model WJ-1101 allows the following even while it is in operation. - Adding another control application to Model WJ-1101. - Modifying control applications in Model WJ-1101. You can therefore add a new control application and modify an existing control application without interrupting equipment operation. Manual override: The manual override function enables you to manually change the input and output data. This helps you to take temporary action against a failure. Autonomous distributed control: To reduce the risks of failures, Model WJ-1101 independently operates even when a part of the building management system (BMS) fails. 1

System Architecture Supervisory device Engineering tool Ethernet (BACnet/IP and multi-protocols)* 1 Supervisory network Switching hub BACnet Controller Model WJ-1101 Infilex VC Model WY5706C Ethernet (proprietary)* 2, * 4 RS-485 (BACnet MS/TP): Max. 50 devices and 1,200 m * 5, * 6 Infilex VC Model WY5706C Switching hub Switching hub RS-485 (Modbus RTU/Modbus ASCII): Max. 31 devices and 1,200 m * 5, * 7 Infilex VC Model WY5706C Third-party Modbus device * 3, * 4 Third-party Modbus device Third-party Modbus device Note: *1 Maximum wiring length between each device and the switching hub must be 100 m. *2 Because of the daisy-chained Ethernet locally connecting s, a switching hub is not required between adjacent devices (between Model WJ-1101 and its adjacent or between adjacent s). This connection between Model WJ-1101 and the I/O modules is called "local I/O network." The maximum wiring length between adjacent devices on the local I/O network must be 100 m. *3 The connection between Model WJ-1101 and s through the Ethernet of the supervisory and primary device networks is called "remote I/O network." Each on the remote I/O network requires a switching hub. Model WJ-1101 communicates with the s using our proprietary protocol. *4 Model WJ-1101 allows a maximum of 20 s to connect on the local I/O network and on the remote I/O network. *5 Model WJ-1101 as a primary device supports BACnet MS/TP and Modbus over RS-485 for communicating with the secondary devices. The maximum wiring length of each line of the secondary device network must be 1,200 m. BACnet MS/TP or Modbus communication is selectable through the S/W settings. *6 Model WJ-1101 allows a maximum of 50 MS/TP devices to connect on a single BACnet MS/TP line of the secondary device network. These 50 devices can include a maximum of 20 third-party devices. For connecting third-party devices only, Model WJ-1101 allows a maximum of 31 MS/TP devices to connect on a single BACnet MS/TP line of the secondary device network. *7 Model WJ-1101 allows a maximum of 31 Modbus devices to connect on a single Modbus line of the secondary device network. Primary device network Secondary device network Figure 1. System architecture example Model Number Model number WJ-1101W0000 Description BACnet controller for general-purpose building applications - Ethernet (BACnet/IP) communication - 100 V AC 240 V AC power 2

Specifications Basic specifications Item Specification Power Rated voltage range 100 V AC 240 V AC at 50 Hz/60 Hz Allowable voltage range 85 V AC 264 V AC at 50 Hz/60 Hz ± 3 Hz RAM and RTC backup battery Lithium battery (not rechargeable) CPU 32 bit Memory SDRAM: 256 MB, flash ROM: 32 MB, SRAM: 2 MB Communication Ethernet (LAN 0) Protocol BACnet /IP Communication speed 100 Mbps/1000 Mbps Type of connection Autonegotiation, auto MDI/MDI-X Ethernet for Protocol Proprietary protocol Communication speed 100 Mbps connection Type of connection Auto MDI/MDI-X (LAN 1, LAN 2) Number of s Max. 20 s for one Model WJ-1101 RS-485 Protocol BACnet MS/TP or Modbus (selected through S/W setting) Number of lines 2 Communication speed 4.8 kbps/9.6 kbps/19.2 kbps/38.4 kbps/76.8 kbps (selected through S/W setting) Number of devices 50 devices (31 devices) per line* 1 Housing material, color Modified PPE, black Weight Approx. 800 g Mounting On a DIN rail or with screws Mounting location In a control panel Environmental Rated operating Ambient temperature 0 C 50 C conditions conditions Ambient humidity 10 %RH 90 %RH (non-condensing) Vibration 5.9 m/s 2 or less at 10 Hz 150 Hz Transport and Ambient temperature -20 C 60 C storage conditions Ambient humidity 5 %RH 95 %RH (non-condensing) Vibration (for transport) 9.8 m/s 2 or less at 10 Hz 150 Hz Vibration (for storage) 5.9 m/s 2 or less at 10 Hz 150 Hz CPU: central processing unit MDI: medium dependent interface MDI-X: medium dependent interface crossover PPE: polyphenylene ether RAM: random-access memory ROM: read-only memory RTC: real-time clock SDRAM: synchronous dynamic random-access memory SRAM: static random-access memory Note: *1 The maximum number of devices that Model WJ-1101 allows is 50 for our own devices or 31 for third-party devices. 3

Input/output specifications Item Specification Digital input Number of inputs 4 Voltage/current 24 V DC typ./5 ma DC typ. Type of output from a Dry contact or open collector device in connection Pulse counting* 1 10 Hz or less Universal input Number of inputs 8 Voltage input Range 0 V DC 10 V DC/2 V DC 10 V DC/0 V DC 5 V DC/1 V DC 5 V DC Impedance 1 MΩ typ. Current input Range 4 ma 20 ma Impedance 100 Ω typ. Resistance Type of output from a Pt100, Pt1000 temperature detector (RTD) input sensor in connection Measuring range of a Pt100 sensor 0 C 50 C/0 C 100 C/0 C 200 C/-20 C 80 C/-20 C 30 C/ -50 C 100 C/-100 C 50 C Measuring range of a 0 C 50 C/0 C 100 C/-20 C 80 C/-20 C 30 C/-50 C 100 C Pt1000 sensor Digital input Voltage/current 5 V DC typ./ 1.5 ma DC typ. Type of output from a device in connection Open collector Digital output Number of outputs 6 Relay output Type of output Relay, N.O.(normally open) contact Contact rating Max. 24 V AC, 0.5 A (Inductive load: cos = 0.4 or greater Minimum applicable load 5 V DC, 10 ma DC Analog output Number of outputs 6 Voltage Range 0 V DC 10 V DC/2 V DC 10 V DC/0 V DC 5 V DC/1 V DC 5 V DC output Load resistance Min. 10 kω Current output Range 4 ma 20 ma Load resistance Max. 500 Ω Note: *1 Pulse counting for the digital inputs must meet the following pulse width and interval. Min. 30 ms Min. 100 ms Min. 30 ms 4

Dimensions Figure 2. Outside dimensions (mm) 5

Infilex is a trademark of Azbil Corporation in Japan or in other countries. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Modbus is a trademark or a registered trademark of Schneider Electric in France, the USA and other countries. Specifications are subject to change without notice. Building Systems Company http://www.azbil.com/ Rev. 1.0 Apr. 2016 AX-230E 6