575F-2071, 1000F-2071, 1100F-2071

Similar documents
Nokeval. No Manual. Model for serial inputs

Nokeval. No Manual. Models 575F, 1000F, 1100F, Scalable counter for pulse sensors

575F-2051, 575F F-2051, 1000F F-2051, 1800F-2251

USER MANUAL V1.1. Setpoint unit 2022Setp

User manual Firmware V3.2 PCB V Serial to analog converter

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

OPTRIS CT communication interface

11 Serial Communications

Nokeval. FD100 series. User Manual

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

IFC 100 Supplementary instructions

LD-RTD / LD-TC Temperature Controller

Optris CT/ CTlaser/ CTvideo communication interface

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

PRECISION DIGITAL CORPORATION

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Getting Started with your D3000M Series Module

TABLE OF CONTENTS. Communication Functions

Z58-6XX SERIES 6 Digits Universal Position Indicator for incremental or absolute encoders

OPTRIS CT/CTL communication interface

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Trident and Trident X2 Digital Process and Temperature Panel Meter

CHAPTER 1. Introduction Introduction 3

1. Introduction. 2. Installation MODBUS INTERFACE

45SD Series Bus Expansion Cards For use with Q45X Series Photoelectric Sensors on SDS Bus Networks

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide

Vorne Industries. 87/001 RS-485 Communications Board User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

The I-7530A RS-232/485/422 to CAN Converter

Manual 601: : USB/RS232. Specifications. Contents. Options

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Flex Series User Guide

DirectNET Host. Communications Programs. In This Chapter...

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Vorne Industries. 87/708 Master Clock Display User's Manual

The I-7530A-MR Modbus RTU to CAN Converter

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

User s Guide. LDB-RTU Meters for Modbus RTU. Shop online at omega.com. For latest product manuals:

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Building the FlipChip Tester

melabs Serial LCD Firmware Version 1.1 3/5/07

HDV100A3 Command Response Protocol

AU-E - Practical Programmable Logic Controllers (PLCs) for Automation and Process Control

KYTronics Corp.,Ltd KYT-22XX SPECIFICATIONS B 1 OF kytronics.co.kr. 3 rd Floor, A-Dong, Twin Town-Bldg,

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

8520/8520R. User Manual

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

DUAL LOOP DETECTOR WITH MODBUS COMMUNICATIONS

Forcom Technology Co., Ltd. Intelligent RS-485/422 to RS-232 converter

RS 485 Mini Modbus 1AO

RS-422 Code-Operated Switches

plc numbers Encoded values; BCD and ASCII Error detection; parity, gray code and checksums

Single-Axis Counter BDD 611

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

Compact Card Dispenser

Chapter. Modbus. In This Chapter...

Vorne Industries. 87/415 Rate Monitor Display User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

AMALGAMATED INSTRUMENT CO PTY LTD ACN: LD-BC Binary/BCD/Gray Code Large Digit Display Operation and Instruction Manual

A GUIDE TO RS-232 COMMUNICATION WITH FX PLCS

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

Converter Box Data Sheet

THERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.

WIE485 and WIE232. Wiegand to RS485 or RS232 bidirectional interface converters for systems with contactless readers

RS485 MODBUS Module 8I8O

SGH. SGH inch stroke range, no terminating resistor 5-pin M12 mating plug, mounting bracket. CANopen Output Signal SGH-80-4-TR

RS485 MODBUS Module 8AO

BV4531U. I2C or Serial 6 Way Relay

Series 370 Stabil-Ion Gauge Controller with RS-485 Interface Option

Xanura Isolated RS232 interface module CTX15 MBO BA. OEM module for serial communication with Xanura

GmbH, Stettiner Str. 38, D Paderborn

BMV Text Protocol. Table of contents

Modbus Remote Communication Protocol for REM 54_. Technical Description

Thermometer / Barometer System

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

USB-Based 14-Channel Data-Acquisition Module

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

melabs Serial LCD Firmware Version 1.0 2/7/07

PD765 TRIDENT. Trident Series Process & Temperature Meters.

MAX Modular Analogue Expandable System

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340

RS485 MODBUS Module 16I-M

MHz TRANSCEIVER. Bi-Directional Send and Receive. Compatible with: Transmitter Receiver Transceiver. Part # Part #

The Fusion Series of Large displays

Installation and Operation Manual. INTEGRA BTU Meter System

VIGOR PROGRAMMABLE LOGICAL CONTROLLERS VIGOR ELECTRIC CORP.

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Manual. Specifications. Contents. Options

GW-7228 J1939/Modbus RTU Slave Gateway

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Product Specification for SAB-S-MODBUS

Specification. Current Consumption Range 8m * Rotational Angle +/- 50 degrees * Shear Angle +/- 40 degrees *

LPG STM 94442A User s Manual

LK Technical Manual. Revision: 2.0

Manual DTM Digital Pressure Transmitter

help guide ND5134 SCOREBOARD CONTROLLER

Two 16 Bit Registers, One for Integer Display One for Floating Point.

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Transcription:

Nokeval No 290507 Manual Model 575F-207, 000F-207, 00F-207 and 800X-207 Serial input RS232 / RS485

Contents General Description... 3 Technical specifications... 3 Front panel...4 Configuration stage... 4 Resetting configuration parameters... 4 Case dimensions:... 4 Configuration... 5 Serial protocol (SCL)... 6 Counting check sum... 6 Example of control message without BCC... 6 XOR-function without calculator... 7 Non-addressable ASCII protocol... 7 Display modes... 7 TEXT Mode... 7 NUMERICAL Mode... 7 Interpretation... 8 Displaying... 8 Reading front panel keys... 8 Buffered method... 8 Unbuffered method... 8 Terminal Connections... 9 Field display construction... 0 Modular indicator serie 2000... Manufacturer: Nokeval Oy Yrittäjäkatu 2 FIN-3700 NOKIA Tel. +358 3 342 4800 Fax. +358 3 342 2066 2

Model XX-207 for serial data General Description The large field display series 207 for serial communication is designed for applications where a readability of 20 to 00 metres is required. Configuration is easy with keys and a 6-digit minidisplay inside the case. The displays use the simple Nokeval SCL protocol where only the address, value and check sum are sent. The displays come standard with both the serial inputs RS- 232 and RS-485. The serial bus is galvanically isolated from the processor and the power supply. In the configuration mode you can set the address, baud rate and the type of number value that you want to appear on the display after power connection. In industrial environments use of the addressable serial signal RS-485 is always recommended. 3 displays can be connected to one bus and by using a serial data converter (72R), another 3 displays can be added on. The maximum distance of the bus is km. Serial input RS-232 only accepts one display connected to the bus the maximum distance being 5 m. The displays can also be used outdoors if exposure to direct sun light is prevented by using a sun cover. Case protection is IP65. Types: 575F5-207 Digit height 57 mm, 5 digits, red LED Dark grey plastic enclosure 000F4-207 Digit height00 mm, 4 digits, red Black steel enclosure 00F6-207 Digit height 00 mm, 6 digits, red Black steel enclosure Technical specifications: Input: serial signal RS-485 and RS-232, selection with terminal connections, galvanically isolated Max. distancies: 000 m with RS-485 20 m with RS-232 Number of meters in one loop: with RS-232; -3 with RS-485 Data 8 characters, stop, no parity Addresses: 0...99 Baud rate: 300, 600, 200, 2400, 4800, 9600 and 9200 baud General: Configuration keys and a minidisplay inside the case Operating temp. -35..+50 C Terminals removable, wire 2,5 mm² Power supply 85..240 VAC or 24 VDC ±5% Case protection IP65 Weight 575F: 3 kg, 000F: 5 kg, 00F: 8 kg, 800F:8 kg Readability of displays: Digit size 57 mm 20..30 metres 00 mm 40..50 metres 80 mm ca. 00 metres How to order: Type Number of digits Input card Power supply 85-240VAC or 24 VDC 00F5-207-230VAC 800Fx-207 Digit height 80 mm, -5 digits, red Black steel enclosure 3

Front panel Conf-LED Unit is in configuration mode User controllable indicators. Arrow-buttons( ) are used to change numerical values and when moving in menustructure. 5620.0 Star-key ( ) accepts selected function (enter). Configuration stage Moving into selected menu title. Configuration can be started by pressing and holding - and -keys simultaneously for 2 seconds. Specified instructions on pages 6-7 Configuration. Resetting configuration parameters Some times it is necessary to return indicator parameters to factory defaults, e.g. if secret access code is missed. Resetting can be done by pressing and holding - and -keys simultaneously for 2 seconds when connecting supply voltage. Prosedure will reset all settings to factory defaults. Dimensions: 28, 500, 670 045 28, 455, 625, 025 96,20, 30, 20 8,47, 20, 330 3,88,250, 375 30, 482, 650, 030 Dimensions shown in the order: 575F, 000F, 00F, 800F Glands: 2 x PG 3 4

Configuration Beginning: Configuration can be started by pressing and holding - and -keys simultaneously for 2 seconds. Arrow keys moves up and down in main menu. Desired function is selected with -key. Save mode can be selected directly by pushing -key in main menu. + displ INTENS BR 5 Intens: Display brightness 0..5, brightest 5, default 7 DEFDIS ID DOT DefDis: Display after connecting power: ID = Display address Dot = Dot in display Blanc = Empty display BLANC MODE TEXT Mode: Text = Text mode Num = Numerical mode NUM DEC DEC: The max number of decimals 0..5 (Num mode only) Serial PROTOC SCL Protoc: Message protocol, addressable SCL or nonaddressable ASCII BAUD 300 Baud: Baud rate selection: 300, 600, 200, 2400, 4800, 9600, 9200 ADDR 0 Addr: Serial address 0..27 (SCL only) BCC ON / OFF Bcc: Checksum selection ON =used (SCL only) RESP ON / OFF Resp: Responce message select: ON = used, Switch off if several units are controlled under same address (SCL only) DELIM 3 Delim: ASCII value of delimiter character between messages (<CR>=3) (ASCII only) FIRST 0 First: Number of characters to ignore at star of message, 0 = not used (ASCII only) COUNT 2 Count: Max number of characters processed on the message..2, (ASCII only) SAVE TOUT 0 Accept changes and exit from configuration mode Tout: 0..5 sec, The time after which the display is cleared when no messages are sent (0 = not used). UnDo Undo changes and exit from configuration mode 5

Serial protocol (SCL) General Port settings Baud rate: 300, 200, 2400, 4800, 9600 or 9200. 8 data bits, none parity, stop bit. Protocols Two different serial protocols may be used to control X-207. The protocol is selected in the configuraton menu. It can be either Nokeval SCL or Ascii. In Ascii protocol, there is no address involved, so every display in the bus will show the same display. These protocols are introduced in the next chapters. SCL protocol The SCL message consists of the actual command supplemented with some control bytes that are necessary to address the message to the correct device and to detect transmission errors. Commands for 207 To control the display, use DISP command (use upper case): DISP 23456 After this command, the display will read 23456. See more on chapter Display modes. To control the alarm indicators A..M2 at the front panel, use LED command: LED 000X This command will switch the three leftmost leds off (0), light up the two next leds (), and blink the sixth led (X). The Conf led is not user controllable. To read the four front panel keys, use KEYB command: KEYB About this command, see chapter Reading front panel keys. Control bytes The general format of SCL command packet is: <ID>command<ETX><BCC> The first byte sent (ID) has two purposes: it selects the device to which the command is intended, and indicates that a completely new command is to come. The byte is calculated by adding 28 (or 80h in hexadecimal representation) to the address of the device to be controlled, that is, the most significant bit is set. If you want to command a device in address 4, the <ID> byte will be 32 (or 84h). This is a single byte whose value is 32, do not send individual numbers, 3 and 2! The command is one of the commands explained previously (e.g. DISP 28.5). ETX character means End of Transmission. It terminates the command. It is a single byte with Ascii value 3 (03h). BCC is a checksum. The sender calculates it from the command and ETX bytes using XOR operation. The id character is not involved in BCC calculation. If you do not want to send checksum, you must switch it off in the 207 menu (set BCC OFF). It is recommended to use checksum, but sometimes it is not possible calculate it. An example of a complete command packet (both characters and their Ascii values in hex shown): <80h> D I S P 0 <ETX><BCC> 80 44x49x53x50x20x30x 03 = D The x represents XOR operation in BCC calculation. Response 207 will respond to the command using SCL protocol. The response message is in the following form: <ACK>response<ETX><BCC> Instead, if there was errors in the transmission or in the command, the response will be: <NAK>errorcode<ETX><BCC> ACK is a single byte with Ascii value 6 (06h). It indicates that the device has accepted the command. About ETX byte, see previous chapter. The response is dependent on the command sent. X-207 has empty response except for KEYB command. BCC is calculated similarly with the command BCC, taking all the bytes from ACK to ETX. This time 207 will calculate the checksum, and your task is to check it if you want to. Error response starter NAK is a single byte with Ascii value 2 (5h). It is followed by a single number representing the type of error. 3 means BCC error, while 4 indicates non-recognized command. 6

Non-addressable ASCII protocol When using non-addressable ASCII protocol, the message sent to X-207 consists of the text to display only, with no addresses, checksums etc. However, there has to be a terminating character at the end of the message so that distinct messages can be separated from each other. Most often this delimiter is a newline character <CR> or <CR><LF>. The ascii value of that character is selected at the conf menu item Delim. Ascii value of <CR> is 3. When Delim is set to 3, also <CR><LF> (Ascii 3 and 0) is interpreted as single character. Sometimes the message contains additional characters that are not to be displayed. If these occur before the actual message to display, the First setting can be set to match the number of these characters Display modes X-207 can be used to show short text messages, but most usually it is used to display measurement results, that is numerical values. There are two distinct display modes to choose from. Generally, when the device that is contolling 207 has formatted the message keeping in mind there is a six digit display, the Text mode gives free contol over the 207 display. Also Text mode must be selected in order to display non-numerical text messages. On the other hand, when displaying numerical results, the Numerical mode is more flexible. TEXT Mode In the Text mode, X-207 doesn t process the message in any way. The first received message is placed at the leftmost position of the display and so on. However, dot (Ascii 46) and comma (44) are placed as the decimal point of the previous character, if applicable, thus not taking an display position of their own. It takes never not more than 2 characters to fill up the display. This case will occur when each letter is succeeded with a dot:.2.3.4.5.6. If more characters are sent that can fit on the display, the trailing characters are ignored. If the display is wanted to be aligned to the right, there is no other way than to send a correct number of spaces (Ascii 32) before the actual characters. The display can be cleared with a message with only spaces ( or more). and they are abandoned. Likewise the number of characters to display may be limited with Count setting to..2. An example of control message: ANS_29.4PPP<CR> Set Delim=3 (<CR>), First=4 (ANS_ is cut off) and Count=4 (PPP is removed). The display will be: [29.4 ] If there is a start character in addition to the terminating character, the start character can be removed by increasing the First setting by. The other way to handle this is to set the Delim to match the start character and use Count setting to indicate the end of the message (only if the length of the message is constant). X-207 does its best to represent all Ascii characters from 32 to 26 on its display. However, with seven segment technology there are several compromises. E.g. the number 5 and literal S appear equal. NUMERICAL Mode In the Num mode, X-207 tries to interpret the message as a mathematical figure and then to reconstruct it onto the display right-aligned. This method will give more acceptable display when the message is not specifically targeted for a six-digit display. Interpretation In the message, the first numerical character (0..9 + -.) is searched for. This on the characters are interpreted as a part of a number until first nonnumerical character is encountered. Additionally, there may be space characters between the sign (-) and the number itself. Displaying The number is formatted on the display right-aligned and the sign immediately next to the number. The number of decimals will be the same as in the incoming message, but it may be limited with Dec setting in the menu. If the number is too big, the decimal count is decreased automatically. When decimal count is decreased, X-207 will keep rounding the number properly. If the number is too big to be displayed (e.g. 000 7

000), over/underflow characters are shown. If the number was ununderstandable (no numerical characters), dashes are shown. Overflow [ ^ ^ ^ ^ ^ ^ ] Underflow [ ] Not valid [ - - - - - - ] Examples Message Display _3 _ [ 3 ] - 4. 5 [ - 4.5 ] 66.666 [ 6 6.7 ] (Dec=) 999.9999 [ 0 0 0.0 0 ] Reading front panel keys The front panel keys of X-207 can be read externally using serial bus commands. This way 207 can be used for controlling other systems. Reading the keys is possible with SCL protocol only. Key combinations and cannot be used beause they activate the configuration state. 207 is a slave on the bus: it cannot send the key information on the bus by its own, it must be asken by a master. Buffered method Send command KEYB with no parameters for 207. The response consists of a single hexadecimal character (0 9, A F, Ascii 48 57, 65 70) and possibly a letter L (76). The hex character represents the key status so that the lowest bit corresponds to the leftmost key (). Näppäin Koodi 2 2 3 4 4 8 The code is succeeded with letter L (e.g. L), if the key has been held pressed more than 0.5 seconds. When using KEYB command, 207 uses a buffer to store key presses (max 8 presses). If a key has peen pressed and released before KEYB command is used, 207 will remember the press and return it with the next KEYB command. Similarly, if there has been several keypresses, each of them is buffered ad then returned one by one with every KEYB command. If four buttons is not enough, one of the buttons can be reserved as a shift key that doubles the functions of the other keys. An excellent choice is ; remember that combination is not available. Without "shift" pressed, the other buttons return, 2, and 4. With shift pressed, they return 9, A, and C. Unbuffered method If key buffering is not desired, instead it is more important to know the exact state of the keys in real time, use KEY command. The response is similar to KEYB command, with exception the L suffix is not used. If several keys are pressed simultaneously, the sum of these codes is returned. E.g. keys and : the code is 4+8 = C in hexadecimal. When no keys is pressed, the value is 0 (zero). 8

Terminal Connections Input RS-485 RS-232 A B TxD Com RxD 6 5 4 3 2 6 5 4 3 2 Card slot A Card slot B Card slot C 6 5 4 3 2 7 8 9 Only one of the serial connectors can be used at a time. Card slots B and C are for optional cards Power supply 85..240 VAC (grey 7 and 8) or 24VDC (Green 7 and 9 no polarity) (Terminal unit) Address 2 Address Address 0 Sending PC or PLC 5620.0 5620.0 5620.0 A B A B A B Terminal resistor (0 ohm) in last unit (Jumper J2 on) Twisted, shielded cable RS-485 Serial signal RS-485 loop last unit must be terminated with 0 ohm resistor. Termination can be done on terminal connections or by connecting short cut jumper into following position. 207 RS card version.0 jumper selection 208-RS v.0 Factory setting Fail-safe OFF Terminator OFF Use for other cases and for RS-232 Fail-safe ON Terminator ON Use for the last device in the bus 207 RS card version 2.0 jumper selection 207-RS v2.0 Factory setting Fail-safe OFF Terminator OFF Use for other cases and for RS-232 Fail-safe ON Terminator ON Use for the last device in the bus 207 - PC RS-232 serial connection PC 9-pin conn. 6 2 7 3 8 4 9 5 Connector A 3 2 RxD TxD Com X-207 9

Construction of field display series The field display series is modular and easy to assemble according to customers wishes. The basic construction consists of mother board with tree slots, A, B and C. Slot A determines meter type and provides always input signal. Slot B and C are interchangeable. As factory delivery input signal is always installed into slot A, ma output into slot B and alarms into slot C. In case of f.ex 4 alarms and relay card with 2 change-over contact (2 + 2 relays) are used, you must place second relay card into slot B. If you accept only closing or opening relay contacts, you need only one relay card with 4 relays placed into slot C. The slot B is now usable for other optional outputs. You can have different types of meters by only changing the input card in slot A. Data sheet of each type of meter dictates the possible combinations. Recalibration of card is not needed; only scaling and other settings must be set by front panel keys. All cards have calibration memory Slots A-C A B C Power supply 2...32 VDC (Green connector) or 85...240 VAC (Grey connector) Change of meter type: Input card is placed always to slot A. By changing input card you can get an other type of meter. You can change meter with pulse input to meter with current input, thermocouple, strain gage etc. Additional slots: Additional cards provide output 4..20 ma, alarms, serial interface, BCD output etc. Meter data sheet dictates possible combinations. grey connectors allow line voltage 0..240 VAC (relay contacts). Power supply: There are two different mother boards power supply 85..240 VAC and 2..32 VDC. VDCmother board accepts 24 VAC. Connectors are colour coded. Control electronic case: 0

Modular field display series 575F...800F 4-6-digit red LED display Option cards 6543.2 E² E² DAC Alarm cards: 2 relay card, 4 alarm types, change over contacts 3 relay card, closing contacts 4 I/O-ports Sensor supply: 24VDC, 50 ma 20 202 Process inputs (model 20): 0..20 ma, 4..20 ma 0..5/0 V Potentiometer 00Ω..5kΩ ADC up E² Input card contains: - microprocessor - bus control - keys control - display control E² Model 20: 2 relays change over contacts (also with remote reset) Output cards (not for 20): 0/4..20 ma, 0..0 V RS232 or RS485 Power supply: 85..240VAC or 2..32 VDC / 24 VAC Model 202 contains also process inputs but it can also measure RTD-sensors and thermocouples. 202 has very accurate and fast A/D-converter (6 bit /64 000). 2000 series input and option cards: 20-IN 202-MU 203-IR 204-SG 205-PU 206-CO 2066-SEC 207-RS 208-BCD Process input Multi input Infrared sensor input Strain gage measurement Scaleable frequency indicator Counter input (max 5 khz) Timer function, s/min/h ext. Serial input RS232 / RS485 BCD-, Gray- binary code input (-5 digits) 2000-BASE Base card with power supply 2000-REL2 Alarm card, NO/NC 2000-REL3 Alarm card, Closing contacts 2000-OUT Output card, U and I 2000-RS Serial output RS232 or RS485 2000-I/O 4 pcs input /output ports (60 V / 00 ma)

Nokeval Oy Yrittäjäkatu 2 Tel. +358 3-342 4800 Fax. +358 3-342 2066 FIN 3700 NOKIA email support@nokeval.com http:// www.nokeval.com 2