Modular Table Power System Installation for Runner Non-folding Plug and Play Tables Topic General Safety Warnings Ganging Hardware Electrical Circuits Table of Contents Page End-to-End (Page 4) End-and-Back with Perpendicular End Table (Page 6) Modular Table Power Assemblies 3 Installation: End-to-End Back-to-Back L-Shape Power and Ganging Connections: End-and-Back w/ Perpendicular End Table End-and-Back w/ Modesty Panel Connecting Top 3-4 5 5 6 7 7 Back-to-Back (Page 5) End-and-Back with Modesty Panels (Page 7) Field Drilling for Flex Gangers and Snap-Clips 8 L-Shape (Page 5) Connecting Top (Page 7) Note: Refer to assembly direction # 93960019 for assembly of base power infeed. If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.35) for immediate action by people who want to help you. (Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: 1.616.47.500) Or visit our website: www.steelcase.com 016 Steelcase Inc. Grand Rapids, MI 49501 U.S.A. Printed in U.S.A. Runner Non-folding Plug and Play Table Page 1 of 8
Modular Table Power System Installation WARNING 1" MAX. Risk of Fire or Electric Shock 1. For use in indoor, dry locations only.. Read and install in accordance with all assembly directions. 3. Only connect to products labeled "Modular Table Power System" by Steelcase. 4. Do not modify or strain cables. If damaged, remove from service immediately. 5. Disconnect modular electrical connections before servicing or reconfiguring tables. 6. Tables must be held together with ganging hardware as described in this document, and NOT held together solely by electrical components. 7. Cable clamps must be no more than 1" from modular cable end connector or receptacle. Ganging Hardware Flex Gangers The factory-installed flex ganger position is end-to-end. If back-to-back or end-and-back ganging is required, change the position of the flex gangers at time of installation. Flex ganger locations are pre-drilled for simple relocation when desired. Flex gangers that are not in use can be secured to a parking hook. Bar Gangers A factory-installed threaded insert in the underside of the table accepts the thumb screw. No tools are required to link tables with bar gangers. The threaded insert is not provided in the inboard location for L-shaped configurations (see page 5). Flex Ganger Bar Ganger CABLE LENGTH 1" MAX. Electrical Circuits The modular table power kit is a 0 Amp, 4-wire, -circuit system. The 0 Amp plug infeed allows up to 13 circuit-1 duplex receptacles. The hardwire infeed allows up to 13 duplex receptacles per circuit for a total of 6. The duplex receptacle(s) in the table power kit and every two simplex receptacles from the desktop module count against the 13 duplex receptacles allowed for each circuit. Receptacle faces on the Modular Table Power Kits are marked I, for circuit 1 and II, for circuit. WARNING Risk of Fire or Electric Shock Neutral Ground Hot Hot 1 White, 1 GA Green or no coating, 1 GA Red, 1 GA Black, 1 GA Note: all electrical installations must be reviewed with the local authority for compliance with local code, and must be performed by a qualified person in accordance with codes and regulations applicable at the installation site. Circuit 1 Circuit Page of 8
Modular Table Power Assemblies Single Receptacle SHIPPED COMPONENTS: - 1 cable assembly - 1 hardware kit Double Receptacle SHIPPED COMPONENTS: - 1 cable assembly - 1 hardware kit Cable attachment hole locations for single receptacle cable. HARDWARE: - 1 receptacle bracket - 4 conduit clamps - conduit snap-clips - 8 #10 phillips head screws - black HARDWARE: - receptacle bracket - 5 conduit clamps - conduit snap-clips - 11 #10 phillips head screws - black TOOLS REQUIRED: # phillips head driver TOOLS REQUIRED: # phillips head driver 9" Installing Modular Cable for End-to-End Applications 1. Carefully place table top upside down onto rug or other soft, clean surface.. Single receptacle Identify the conduit path by locating (8) cable attachment holes: () for receptacle bracket, (4) for conduit clamps and () for conduit snap-clips. Double receptacle Identify the conduit path by locating (11) cable attachment holes: (4) for receptacle brackets, (5) for conduit clamps and () for conduit snap-clips. Cable attachment hole locations for double receptacle cable. Table Width 48" 60" 7" 84" Cable Assembly Length 54" 66" 78" 90" 9" Page 3 of 8
Installing Modular Cable for End-to-End Applications (continued) 3. Fasten receptacle bracket(s). 4. Fasten conduit snap-clips. 5. Loosely fasten conduit clamps. 6. Determine direction of power and orient male and RECEPTACLE 7 6 female ends of cable assembly as required. Align ends flush with table edges and snap into clips. CABLE CONNECTOR Note: Infeed has a female connector. 7. Snap receptacle(s) into receptacle bracket(s). 8. Tighten conduit clamps. 9. Carefully flip tables upright into use position. 4 5 WARNING 3 Risk of Fire or Electric Shock 10. Make ganging connections between adjoining tables. 8 CONDUIT SNAP-CLIP CONDUIT CLAMP RECEPTACLE BRACKET TIP: Place a shim under rug to allow a finger hold when assembled unit is ready to upright. - Lack of mechanical connection may lead to cable damage. 11. Connect modular connectors. - Match like colors only. (Green-to-Green, Red-to-Red, Black-to-Black and White-to-White). Push connectors together until both latches engage. Male end of Modular Table Power Cable 10 GANGING HARDWARE 11 CABLE CONNECTOR RED GREEN Female end of Modular Table Power Cable BLACK BLACK WHITE WHITE RED Cable Clamp Orientation 1 Cable Clamp Orientation for table sizes: for table sizes: - 4" L-Leg and T-Leg - 0" L-Leg - 30" L-Leg - 30" and 36" and L-Leg For best cable fit in end-to-end applications, orient cable clamp near base plate as shown above. GREEN Note: Latches fully engaged. 11 Note: Orient colors on both connectors to match. Page 4 of 8
Installing Modular Cable for Back-to-Back Applications Assemble the same as for end-to-end applications (page 4), except as follows: 1. Rotate one conduit snap-clip and cable end 90 o.. For 4" L-leg, 4" T-leg and 30" L-leg tables, rotate conduit clamp near base plate in opposite direction. 3. To gang tables with flex gangers, relocate ganger and hook that are nearest the back of the table, to the back edge, utilizing the holes provided. 4. To gang tables with bar gangers, attach gangers by tightening thumb screws into threaded inserts at back edge. 5. Carefully flip tables upright into use position. 6. Follow steps 10 and 11 from End-to-End Applications (page 4). 4 3 THREADED INSERT FOR BAR GANGER FLEX GANGER CONDUIT CLAMP THREADED INSERT FOR BAR GANGER FLEX GANGER HOOK 4 3 1 CONDUIT SNAP-CLIP Installing Modular Cable for L-Shaped Configurations Assemble the same as for end-to-end applications (page 4), except as follows: FLEX GANGER 5 3 APPROXIMATE LOCATION FOR FIELD-DRILLED HOLE 1. Identify conduit snap-clip hole along back edge toward the center of the table, and fasten snap-clip.. Route the cable to clear dataports. 3. Field drill hole.157" diameter x.50" deep for conduit clamp. 4. Fasten conduit clamp. 5. To gang tables: Relocate ganging hardware utilizing holes provided for back-to-back applications and holes provided toward the center of the table for L-shaped configurations. 6. Carefully flip tables upright into use position. Note: Threaded insert for bar ganger is not provided in this location. 5 1 FLEX GANGER CONDUIT SNAP-CLIP 7. Follow steps 10 and 11 from End-to-End Applications (page 4). Page 5 of 8
Power and Ganging Connections for Various Applications Note: Ganging hardware must fasten tables in locations shown. Field drill hole.157" dia. x.50" deep and fasten conduit clamp. Hole location must be no more than 1" from modular cable end connector. (see WARNING note 7 on page ) If hole for snap-clip is not provided, or it's location causes cable interference with center dataport, field drill hole near cable end in an appropriate location. Drill.157" dia. x.50" deep. Connect base power infeed here. Snap-clip holes are not provided on the following tables: - 4" x 48" L-Leg and T-Leg Snap-clip and ganger holes are not provided on the following tables: - 30" x 48" L-Leg and T-Leg - 36" x 60" T-Leg Power and Ganging Connections for End-and-Back with Modular Perpendicular End Table Plug dataport in perpendicular end table into receptacle of adjacent table. Connect base power infeed here. Power and Ganging Connections for End-and-Back with Non-modular Perpendicular End Table Page 6 of 8
4" JUMPER CABLE Power and Ganging Connections for Various Applications (continued) Note: Ganging hardware must fasten tables in locations shown. Field drill hole for conduit clamp.157" dia. x.50" deep. Hole location must be no more than 1" from modular cable end connector. (see WARNING note 7 on page ) Orient cable connector and snap-clip for proper jumper cable fit. Connect two base power infeeds here. When modesty panels are used, tables cannot be ganged back-to-back, and a jumper cable is not allowed, so two separate base power infeeds must be used. Note: Infeed has a female connector. Power and Ganging Connections for Connecting Top Power and Ganging Connections for End-and-Back Application with Modesty Panel Page 7 of 8
Field Drilling for Flex Gangers and Snap-Clips When interferences prevent the use of pre-drilled holes for ganging or snap-clip attachment, holes may be field drilled as described below: Drill.157" diameter x.50" deep for all screw pilot holes. Drill.197" diameter x.50" deep for flex ganger hook pin-holes. Locate ganger and snap-clip holes using the dimensions shown..375".750" Ganger hook pinhole - Drill.197" dia. x.50" deep..750".65" 1.0".375" Ganger hook pinhole - Drill.197" dia. x.50" deep. 1.375" minimum 1.65" recommended All screw pilot holes - Drill.157" dia. x.50" deep..375" minimum 3.00" recommended TABLE EDGE GANGER AND SNAP-CLIP FIELD DRILLING DIMENSIONS Page 8 of 8