Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

Similar documents
Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions

Avenir & kick Powerway

V.I.A. - Monitor Shroud

Virtual PUCK for media:scape Kiosk and Answer

Installing Simplex and Duplex Receptacles into: Series 9000 Structural Panel Series 9000 Energy Management Panel and Worksurface Avenir Power Panel

Power/Data Instructions. Genius. Movable Walls. September

Haworth Power Technical Sheets January 2018

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

Removing and Replacing Parts

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

and Network Interface Modules Installation Instructions

TDM To MiniMech conversion ProceDure

TIVO DVR UPGRADE INSTRUCTIONS (#80-HD)

Morrison, Currents and Reff Raceways Morrison, Currents and Reff Raceways

INSTALLATION INSTRUCTIONS

ETC Installation Guide

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Trig Planning Guide. December 2012

Part Name/Description Part Number Quantity

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

DUAL-ARM MONITOR MOUNT For in. ( cm) desktop computer monitors

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features

OV1016 Part No OV1016 HEIGHT ADJUSTABLE BENCHING SYSTEM USER GUIDE

DESCRIPTION PRODUCT CODE LIST PRICE DIMENSIONS/INCHES H L D

Installation Instructions

AP-120 Series AP Mounting Kit

Mounting on the Ceiling Using Flush Mount (Face Down)

Copy Machine Reader. Installation and Setup Guide

KI WIREWORKS WIRE ELECTRICAL SYSTEM INTRODUCTION INFORMATION

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

Installing 6 Indexer: PRS Standard Tools

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

SENC 150 REFERENCE MANUAL

Shop Fox Fence Kit Installation Instructions:

Control Box Setup - PRSalpha

TRC-190 User s Manual

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

INSTALLING ColorDMD LED DISPLAY IN BALLY GAMES WITH DISPLAY ON LAMP BOARD

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

Encore XT Manual Gun Upgrade Kit

Termination End. Figure 1

Motorola Droid X Camera Replacement

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

PICO PROTECTOR PG-06 & PK-06 Series

Star Trac Fitness E-ST 5090 Stepper. Install Guide

IBM. Rack Installation Instructions

Upgrading and Servicing Guide

Rack Installation Instructions

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

Flat Screen Garage. Table System Planning Guide WORKING FOR YOU

DOCKING STATION SPECIFICATIONS

TRC-190 User s Manual

HARMONi G3. Quick Start Guide for HARMONi G3. imac Processor/FireWire Upgrade

PICO PROTECTOR PG-25 & PK-25 Series

Installing the Cisco SFS 3504 Server Switch

Power Base AI. Power Base AI. Technical Sheets

Dell Latitude C800 Service Manual

B&W RearView Camera Installation & Operation

Part Name/Description Part Number Quantity

hp uninterruptible power system r12000 xr models installation instructions

Upgrading and Servicing Guide

Cutter Option Installation Instructions

WIFI TOUCH PANEL WALL CONTROL F-TS

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Written By: John Sutton

A-dec 586 Ceiling Monitor Mount

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

FLEX Ex Spring Clamp Terminal Base

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

PRODUCT SPECIFICATIONS Pillar Table

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

Flat Panel Static Wall Mount MSP-SS (GSM-210)

POWER / DATA SOLUTIONS

Standard Strip Series

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

Multi-Mount for Mac Pro " to 5.25" Drive Bay Converter Bracket. Assembly & Installation Manual

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

HD Flex Zero RU Cassette Holder and Bracket

Treadmill Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

Ratchet-Pro Slide Cover

Conductor and Cable Marking Description and Handling

Megatouch FORCE Monitor Chassis Board Replacement

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

BL-FLOWSTN-P FlowStation Module Installation Guide

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Carefully remove the translite from the backbox and then lower the speaker panel to the position shown in Fig. A to gain access to the backbox.

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet

Q2 XBee Handheld Controller Assembly Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)

Transcription:

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables Topic General Safety Warnings Ganging Hardware Electrical Circuits Table of Contents Page End-to-End (Page 4) End-and-Back with Perpendicular End Table (Page 6) Modular Table Power Assemblies 3 Installation: End-to-End Back-to-Back L-Shape Power and Ganging Connections: End-and-Back w/ Perpendicular End Table End-and-Back w/ Modesty Panel Connecting Top 3-4 5 5 6 7 7 Back-to-Back (Page 5) End-and-Back with Modesty Panels (Page 7) Field Drilling for Flex Gangers and Snap-Clips 8 L-Shape (Page 5) Connecting Top (Page 7) Note: Refer to assembly direction # 93960019 for assembly of base power infeed. If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.35) for immediate action by people who want to help you. (Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: 1.616.47.500) Or visit our website: www.steelcase.com 016 Steelcase Inc. Grand Rapids, MI 49501 U.S.A. Printed in U.S.A. Runner Non-folding Plug and Play Table Page 1 of 8

Modular Table Power System Installation WARNING 1" MAX. Risk of Fire or Electric Shock 1. For use in indoor, dry locations only.. Read and install in accordance with all assembly directions. 3. Only connect to products labeled "Modular Table Power System" by Steelcase. 4. Do not modify or strain cables. If damaged, remove from service immediately. 5. Disconnect modular electrical connections before servicing or reconfiguring tables. 6. Tables must be held together with ganging hardware as described in this document, and NOT held together solely by electrical components. 7. Cable clamps must be no more than 1" from modular cable end connector or receptacle. Ganging Hardware Flex Gangers The factory-installed flex ganger position is end-to-end. If back-to-back or end-and-back ganging is required, change the position of the flex gangers at time of installation. Flex ganger locations are pre-drilled for simple relocation when desired. Flex gangers that are not in use can be secured to a parking hook. Bar Gangers A factory-installed threaded insert in the underside of the table accepts the thumb screw. No tools are required to link tables with bar gangers. The threaded insert is not provided in the inboard location for L-shaped configurations (see page 5). Flex Ganger Bar Ganger CABLE LENGTH 1" MAX. Electrical Circuits The modular table power kit is a 0 Amp, 4-wire, -circuit system. The 0 Amp plug infeed allows up to 13 circuit-1 duplex receptacles. The hardwire infeed allows up to 13 duplex receptacles per circuit for a total of 6. The duplex receptacle(s) in the table power kit and every two simplex receptacles from the desktop module count against the 13 duplex receptacles allowed for each circuit. Receptacle faces on the Modular Table Power Kits are marked I, for circuit 1 and II, for circuit. WARNING Risk of Fire or Electric Shock Neutral Ground Hot Hot 1 White, 1 GA Green or no coating, 1 GA Red, 1 GA Black, 1 GA Note: all electrical installations must be reviewed with the local authority for compliance with local code, and must be performed by a qualified person in accordance with codes and regulations applicable at the installation site. Circuit 1 Circuit Page of 8

Modular Table Power Assemblies Single Receptacle SHIPPED COMPONENTS: - 1 cable assembly - 1 hardware kit Double Receptacle SHIPPED COMPONENTS: - 1 cable assembly - 1 hardware kit Cable attachment hole locations for single receptacle cable. HARDWARE: - 1 receptacle bracket - 4 conduit clamps - conduit snap-clips - 8 #10 phillips head screws - black HARDWARE: - receptacle bracket - 5 conduit clamps - conduit snap-clips - 11 #10 phillips head screws - black TOOLS REQUIRED: # phillips head driver TOOLS REQUIRED: # phillips head driver 9" Installing Modular Cable for End-to-End Applications 1. Carefully place table top upside down onto rug or other soft, clean surface.. Single receptacle Identify the conduit path by locating (8) cable attachment holes: () for receptacle bracket, (4) for conduit clamps and () for conduit snap-clips. Double receptacle Identify the conduit path by locating (11) cable attachment holes: (4) for receptacle brackets, (5) for conduit clamps and () for conduit snap-clips. Cable attachment hole locations for double receptacle cable. Table Width 48" 60" 7" 84" Cable Assembly Length 54" 66" 78" 90" 9" Page 3 of 8

Installing Modular Cable for End-to-End Applications (continued) 3. Fasten receptacle bracket(s). 4. Fasten conduit snap-clips. 5. Loosely fasten conduit clamps. 6. Determine direction of power and orient male and RECEPTACLE 7 6 female ends of cable assembly as required. Align ends flush with table edges and snap into clips. CABLE CONNECTOR Note: Infeed has a female connector. 7. Snap receptacle(s) into receptacle bracket(s). 8. Tighten conduit clamps. 9. Carefully flip tables upright into use position. 4 5 WARNING 3 Risk of Fire or Electric Shock 10. Make ganging connections between adjoining tables. 8 CONDUIT SNAP-CLIP CONDUIT CLAMP RECEPTACLE BRACKET TIP: Place a shim under rug to allow a finger hold when assembled unit is ready to upright. - Lack of mechanical connection may lead to cable damage. 11. Connect modular connectors. - Match like colors only. (Green-to-Green, Red-to-Red, Black-to-Black and White-to-White). Push connectors together until both latches engage. Male end of Modular Table Power Cable 10 GANGING HARDWARE 11 CABLE CONNECTOR RED GREEN Female end of Modular Table Power Cable BLACK BLACK WHITE WHITE RED Cable Clamp Orientation 1 Cable Clamp Orientation for table sizes: for table sizes: - 4" L-Leg and T-Leg - 0" L-Leg - 30" L-Leg - 30" and 36" and L-Leg For best cable fit in end-to-end applications, orient cable clamp near base plate as shown above. GREEN Note: Latches fully engaged. 11 Note: Orient colors on both connectors to match. Page 4 of 8

Installing Modular Cable for Back-to-Back Applications Assemble the same as for end-to-end applications (page 4), except as follows: 1. Rotate one conduit snap-clip and cable end 90 o.. For 4" L-leg, 4" T-leg and 30" L-leg tables, rotate conduit clamp near base plate in opposite direction. 3. To gang tables with flex gangers, relocate ganger and hook that are nearest the back of the table, to the back edge, utilizing the holes provided. 4. To gang tables with bar gangers, attach gangers by tightening thumb screws into threaded inserts at back edge. 5. Carefully flip tables upright into use position. 6. Follow steps 10 and 11 from End-to-End Applications (page 4). 4 3 THREADED INSERT FOR BAR GANGER FLEX GANGER CONDUIT CLAMP THREADED INSERT FOR BAR GANGER FLEX GANGER HOOK 4 3 1 CONDUIT SNAP-CLIP Installing Modular Cable for L-Shaped Configurations Assemble the same as for end-to-end applications (page 4), except as follows: FLEX GANGER 5 3 APPROXIMATE LOCATION FOR FIELD-DRILLED HOLE 1. Identify conduit snap-clip hole along back edge toward the center of the table, and fasten snap-clip.. Route the cable to clear dataports. 3. Field drill hole.157" diameter x.50" deep for conduit clamp. 4. Fasten conduit clamp. 5. To gang tables: Relocate ganging hardware utilizing holes provided for back-to-back applications and holes provided toward the center of the table for L-shaped configurations. 6. Carefully flip tables upright into use position. Note: Threaded insert for bar ganger is not provided in this location. 5 1 FLEX GANGER CONDUIT SNAP-CLIP 7. Follow steps 10 and 11 from End-to-End Applications (page 4). Page 5 of 8

Power and Ganging Connections for Various Applications Note: Ganging hardware must fasten tables in locations shown. Field drill hole.157" dia. x.50" deep and fasten conduit clamp. Hole location must be no more than 1" from modular cable end connector. (see WARNING note 7 on page ) If hole for snap-clip is not provided, or it's location causes cable interference with center dataport, field drill hole near cable end in an appropriate location. Drill.157" dia. x.50" deep. Connect base power infeed here. Snap-clip holes are not provided on the following tables: - 4" x 48" L-Leg and T-Leg Snap-clip and ganger holes are not provided on the following tables: - 30" x 48" L-Leg and T-Leg - 36" x 60" T-Leg Power and Ganging Connections for End-and-Back with Modular Perpendicular End Table Plug dataport in perpendicular end table into receptacle of adjacent table. Connect base power infeed here. Power and Ganging Connections for End-and-Back with Non-modular Perpendicular End Table Page 6 of 8

4" JUMPER CABLE Power and Ganging Connections for Various Applications (continued) Note: Ganging hardware must fasten tables in locations shown. Field drill hole for conduit clamp.157" dia. x.50" deep. Hole location must be no more than 1" from modular cable end connector. (see WARNING note 7 on page ) Orient cable connector and snap-clip for proper jumper cable fit. Connect two base power infeeds here. When modesty panels are used, tables cannot be ganged back-to-back, and a jumper cable is not allowed, so two separate base power infeeds must be used. Note: Infeed has a female connector. Power and Ganging Connections for Connecting Top Power and Ganging Connections for End-and-Back Application with Modesty Panel Page 7 of 8

Field Drilling for Flex Gangers and Snap-Clips When interferences prevent the use of pre-drilled holes for ganging or snap-clip attachment, holes may be field drilled as described below: Drill.157" diameter x.50" deep for all screw pilot holes. Drill.197" diameter x.50" deep for flex ganger hook pin-holes. Locate ganger and snap-clip holes using the dimensions shown..375".750" Ganger hook pinhole - Drill.197" dia. x.50" deep..750".65" 1.0".375" Ganger hook pinhole - Drill.197" dia. x.50" deep. 1.375" minimum 1.65" recommended All screw pilot holes - Drill.157" dia. x.50" deep..375" minimum 3.00" recommended TABLE EDGE GANGER AND SNAP-CLIP FIELD DRILLING DIMENSIONS Page 8 of 8