CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual

Similar documents
CVI Controllers - Profinet IO - Manual

G5 Weighing Instrument

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

DSC FIELDBUS MODULES...

CVIPC From the Version X. User s Manual

eloprog 485EPF.. - Vers. 1.2 eloprog Configurable safety system FIELD BUS MODULES

EL731 PROFIBUS INTERFACE

3G3FV SI-P Option Card for Profibus-DP Instructions 02/16/00

INpact Slave PCIe. Profibus/PROFINET IRT Fiber Optic/CC-Link/DeviceNet USER MANUAL EN 1.5

PROFIBUS DP/CAN Gateway PCA-100. User Manual

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

Operating Instructions. Modules Fieldbus

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB

GS Dupline Profinet Gateway. Benefits. Description

Operating Instructions. Modules Fieldbus

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

Manual. Fieldbus Gateway UFF41B DeviceNet and PROFIBUS DP. Edition 02/ / EN

SBPC-21-PB FifeNet to Profibus Gateway

SCHMIDT Sensor interface PROFIBUS Instructions for use

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

MFC-EN Ethernet-I/P Fieldbus expansion Unit AFC3000E-FB-EN-2

X-gateway Interface Addendum DeviceNet Scanner Interface

G3 Series PROFIBUS DP Technical Manual

12.3 Fieldbus I/O Board

Servo press kit YJKP - Host interface

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

Quick Start Manual G2-2 Series with Ethernet Interface

Output Interfaces for SVS2000 TM Installation & Operation Manual

SMART RELAY SRW 01 V4.0X

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

RMx621. Appendix to the operating manual

Supplementary device manual AS-i controller e with Profibus DPV1 A AC1355, AC1356 AC1365, AC1366

Additional instructions Memograph M, RSG45 Advanced Data Manager

Anybus X-gateway. PROFINET IRT (2.32) Interface NETWORK GUIDE

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

FAQ 03/2014. How do I go online? SIMOTION & SINAMICS.

MFC-DN Devicenet Fieldbus expansion Unit AFC3000E-FB-DN-1

RMx621 /FML621. Appendix to the operating manual

FC8x. Profibus Communication

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

PROFIBUS Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIFIT SNI UFF41B/UFR41B Fieldbus Gateway for MOVIGEAR SNI

MN1954 Fieldbus Option

Thyro-PX Anybus PROFINET

EL731 DEVICENET INTERFACE

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

VPGate Manual PROFINET to Serial

Additional instructions Videographic recorder LINAX DR3000. PROFINET Device

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

E-LIT CONFIG V X

Driver Manual (Supplement to the FieldServer Instruction Manual) FS X30 DeviceNet Master Adapter Driver

PROFIBUS Interface WM : PD

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

Instruction Manual Power Distribution System SVS16-PN-XX

ControlNet Adapter Interface

Type code. BLCEN-8M12LT-4AI-VI-8XSG-P Ident-No Nominal system voltage 24 VDC. Nominal current Vo Max. current Vo

Danfoss FCD 300 AS-i and Siemens DP/AS-i Link 20E

DN120 DeviceNet Gateway User Manual

Safety-M Communication Modules BMxx

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIFIT SNI Fieldbus Gateway UFF41B for MOVIGEAR SNI

FC 300 DeviceNet and Allen Bradley Control logix 5550

CVI3 SUITE software V X. Installation guide

BL compact fieldbus station for DeviceNet 4 Analog Outputs for Voltage BLCDN-4M12S-4AO-V

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

BB2 Profibus DP option

RM30xx Profibus Brief instructions efector400

Profibus DP Expansion Board

Contents User Manual For PIM

Manual. Fieldbus Interface DFE33B EtherNet/IP and Modbus/TCP. Edition 10/ / EN

Modbus/ PROFIBUS DP Gateway PM-160

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

X-gateway Interface Addendum DeviceNet Scanner

DT7000 Communication I/O Gateway User s Guide Version 2.6

PROFI-5053 PROFIBUS Remote I/O Module Quick Start Guide

01325T -- Robot Welder

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

Anybus-CC CFW-11. User s Manual. Phone: Fax: Web: -

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA)

VersaMax IP Input Module

FieldServer FS DeviceNet Master Adapter Driver

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

6053/6055 ControlNet Communications Interface

Start-up Guide. Copyright 2015, Desoutter HP2 7SJ UK

User Manual Gateway component for EtherNet/IP

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

Technical Manual. HA Issue 4. Copyright Parker SSD Drives, Inc 2008

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

Drive System Application

OPERATING INSTRUCTIONS. Flexi Soft. Gateways

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

Instruction Manual Power Distribution System SVS16-EN-XX

Driver Manual. FS DeviceNet Master Adapter Driver

Transcription:

1/36 CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual N - Copyright 2011, St Herblain France All rights reserved. Any unauthorized use or copying of the contents or part thereof is prohibited. This applies in particular to trademarks, model denominations, part numbers and drawings. Use only authorized parts. Any damage or malfunction caused by the use of unauthorised parts is not covered by Warranty or Product Liability.

2/36 2/36

3/36 TABLE OF CONTENTS 1. CONTROLLERS TYPE... 5 2. CVIC II & CVIL II CONTROLLERS... 6 2.1. CVIX II - MEMORY MAPPING TABLE... 6 2.2. CVIX II - INPUTS & OUTPUTS... 7 2.2.1. Inputs & Outputs assignment... 7 2.2.2. Inputs Descriptions... 7 2.2.3. Outputs Descriptions... 8 2.3. CVIX II - CYCLE SELECTION... 9 2.3.1. Cycle number selection... 9 2.3.2. Selected Cycle (Cycle Echo)... 9 2.4. CVIX II - TIGHTENING RESULTS... 10 2.5. CVIX II CONTROLLERS - PLC CONFIGURATION... 11 2.5.1. Standard Memory Mapping & PLC Configuration... 11 2.5.2. Profibus DP... 12 2.5.2.1. CVIxII Configuration... 12 2.5.2.2. Simatic Step 7 Configuration... 12 2.5.3. Profinet IO... 13 2.5.3.1. CVIxII Configuration... 13 2.5.3.2. Simatic Step 7 Configuration... 13 2.5.4. Device Net... 15 2.5.4.1. CVIxII Configuration... 15 2.5.4.2. RSNetWorx Configuration... 15 2.5.5. Ethernet IP... 16 2.5.5.1. CVIxII Configuration... 16 2.5.5.2. RSLogix 5000 Configuration... 16 2.5.5.3. RSNetWorx Configuration... 16 2.5.6. CC-Link... 17 2.5.6.1. CVIxII Configuration... 17 2.5.6.2. MELSOFT Configuration... 17 3. MULTICVIL II CONTROLLERS... 18 3.1. MULTICVIL II - MEMORY MAPPING TABLE... 18 3.2. MULTICVIL II - INPUTS & OUTPUTS... 19 3.2.1. Inputs & Outputs definition... 19 3.2.2. Inputs Descriptions... 19 3.2.3. Outputs Descriptions... 20 3.3. MULTICVIL II - CYCLE SELECTION... 21 3.3.1. Cycle number selection... 21 3.3.2. Selected Cycle (Cycle Echo)... 21 3.4. MULTICVIL II - LIST OF OK & NOK SPINDLES REPORT... 22 3.5. MULTICVIL II - SPINDLES VALIDATION... 23 3.6. MULTICVIL II - PLC CONFIGURATION... 24 3.6.1. Standard Memory Mapping & PLC Configuration... 24 3.6.2. Profibus DP... 25 3.6.2.1. MultiCVIL II Configuration... 25 3.6.2.2. Simatic Step 7 Configuration... 25 3/36

4/36 3.6.3. Profinet IO... 26 3.6.3.1. MultiCVIL II Configuration... 26 3.6.3.2. Simatic Step 7 Configuration... 26 3.6.4. Device Net... 27 3.6.4.1. MultiCVIL II Configuration... 27 3.6.4.2. RSNetWorx Configuration... 27 3.6.5. Ethernet IP... 28 3.6.5.1. MultiCVIL II Configuration... 28 3.6.5.2. RSLogix 5000 Configuration... 28 3.6.5.3. RSNetWorx Configuration... 28 4. APPENDIX... 29 4.1. CVIX II - PLUGGED MODULE STATUS... 29 4.2. MODULES DETAILS... 30 4.2.1. Profibus DP Module... 30 4.2.2. Profinet IO Module... 31 4.2.3. Profinet IO 2 ports Module... 32 4.2.4. Device Net Module... 33 4.2.5. Ethernet IP Module... 34 4.2.6. Ethernet IP 2 ports Module... 35 4.2.7. CC-Link Module... 36 4/36

1. Controllers Type 5/36 CVIC II CVIR II One tool can be plugged to the controller ( ECx / MCx ). CVIL II One tool can be plugged to the controller ( ERSx ). One tool can be plugged to the controller ( ERx / EMEx ). MULTICVIL II The CPU (master) of the MULTICVIL controls the slaves CVIL II. From 2 to 32 spindles can be plugged to the system (EMEx). The spindles run in synchronous mode. 5/36

6/36 2. CVIC II & CVIL II Controllers 2.1. CVIx II - Memory Mapping Table CVIxII PLC Fieldbus CVIxII Memory Address In Bytes In Words Hexa. Deci. Hexa. Deci. Data Description Access (R/W) Size (bytes) Value Type CVIxII - Data Outputs => PLC Inputs 0x0000 0000 0x0000 0000 CVIx II Outputs R 1 Bool 0x0001 0001 0x0000 0000 Selected Cycle (Cycle Echo) R 1 Integer 0x0002 0002 0x0001 0001 Final Torque Result R 4 Float 0x00 00 0x0003 0003 Torque Trend R 2 Integer 0x0008 0008 0x0004 0004 Final Angle Result R 4 Float 0x000C 0012 0x00 00 Angle Trend R 2 Integer CVIxII - Data Inputs <= PLC Outputs 0x0000 0000 0x0000 0000 CVIx II Inputs W 1 Bool 0x0001 0001 0x0000 0000 Cycle Number Selection W 1 Integer 6/36

7/36 2.2. CVIx II - Inputs & Outputs CVIxII Memory Address In Bytes In Words Hexa. Deci. Hexa. Deci. Data Description Access (R/W) Size (bytes) Value Type CVIx II - Data Outputs => PLC Inputs 0x0000 0000 0x0000 0000 CVIx II Outputs R 1 Bool --- --- --- --- --- --- --- --- CVIx II - Data Inputs <= PLC Outputs 0x0000 0000 0x0000 0000 CVIx II Inputs W 1 Bool --- --- --- --- --- --- --- --- 2.2.1. Inputs & Outputs assignment The inputs & outputs mapping depends on Station I/O configuration. You can configure Inputs and Outputs to match your requirements. NOTE: For CVIL II controllers, the input 5 is always linked to Quick stop 2. 2.2.2. Inputs Descriptions Cycle 1/2/4/8: Binary coded 1-2-4-8 cycle selection. The Cycle number selection 00 to 15 is only taken into consideration by the CVIx II if the Source of cycle number is set to I/O in the station parameters. Start Cycle: Direction: Reset: Error Acknowledge: Spindle Validation: Spindle Val Rev: Synchro IN: The tool runs as long as the signal is on 1. When the signal drops, the cycle stops. Activates the untightening direction mode of the spindle at the Start cycle. Reset station tightening reports, all cycles counters, saved barcode. When the error acknowledgement option is activated in the station parameters, the start of the spindle is not authorized after a reject report. The error acknowledgement input must be validated (pulse) to let the spindle start again. By activating the error acknowledge input, the reject report output is reseted. Allows, or not, the start cycle of the spindle(s). The spindle validation input is only taken into consideration by the CVIxII if the spindle validation source is set in the station parameters. Untightening validation is only controlled when Spindle validation on reverse option is activated in the station parameters. Used in conjunction with Synchro OUT output to synchronise the tightening cycle phases of several controllers (synchro waiting phase). 7/36

8/36 External Stop: When the external stop option is set in a cycle rundown speed, final speed or run reverse phase, the controller will stops the current phase and shifts to the next one as soon as the signal shifts to 1. 2.2.3. Outputs Descriptions Cycle Echo 1/2/4/8: Accept Report: Reject Report: Binary coded 1-2-4-8 selected cycle echo. The cycle echo is sent back only if it corresponds to a programmed cycle in the station. Otherwise it is at 0. Active when the cycle is over and the tightening cycle report is OK. Active when the cycle is over and the tightening cycle report is NOK. Number of cycles OK: This signal switches to 1 when the number of cycles run with an Accept Report is equal to the programmed number of cycles OK in the selected cycle parameters. In Cycle: Ready: Response to the Start Cycle request. Drops to 0 at the end of a tightening or untightening. This signal is at 1 when the controller is in working order. Run reverse enabled: A spindle Reverse validation has been activated. Synchro OUT: Used in conjunction with Synchro IN input to synchronise the tightening cycle phases of several controllers (synchro waiting phase). For detailed information, please read the CVIC II / CVIL II / CVIR II controller manual. 8/36

9/36 2.3. CVIx II - Cycle Selection CVIxII Memory Address In Bytes In Words Hexa. Deci. Hexa. Deci. Data Description Access (R/W) Size (bytes) Value Type CVIx II - Data Outputs => PLC Inputs --- --- --- --- --- --- --- --- 0x0001 0001 0x0000 0000 Selected Cycle (Cycle Echo) R 1 Integer --- --- --- --- --- --- --- --- CVIx II - Data Inputs <= PLC Outputs --- --- --- --- --- --- --- --- 0x0001 0001 0x0000 0000 Cycle Number Selection W 1 Integer --- --- --- --- --- --- --- --- 2.3.1. Cycle number selection The Cycle number selection is only taken into consideration by the CVIx II if the Source of cycle number is set to PLC in the controller station parameters. (0 = no cycle selection). 2.3.2. Selected Cycle (Cycle Echo) This byte indicates the number of the selected cycle in the CVIx II controller (0 = no cycle selected). 9/36

2.4. CVIx II - Tightening Results 10/36 CVIxII Memory Address In Bytes In Words Hexa. Deci. Hexa. Deci. Data Description Access (R/W) Size (bytes) Value Type CVIxII - Data Outputs => PLC Inputs --- --- --- --- --- --- --- --- 0x0002 0002 0x0001 0001 Final Torque Result R 4 Float 0x00 00 0x0003 0003 Torque Trend R 2 Integer 0x0008 0008 0x0004 0004 Final Angle Result R 4 Float 0x000C 0012 0x00 00 Angle Trend R 2 Integer --- --- --- --- --- --- --- --- Final Torque Result: this is the IEEE float value of the torque displayed on the controller. Torque Trend: indicates wether the torque is : 0x00 0x01 0x02 0x03 No report Torque is below the lower limit Torque is over the upper limit Torque is in the limits Final Angle Results: this is the IEEE float value of the angle displayed on the controller. Angle trend: indicates wether the angle is : 0x00 0x01 0x02 0x03 No report Angle is below the lower limit Angle is over the upper limit Angle is in the limits 10/36

11/36 2.5. CVIx II Controllers - PLC configuration 2.5.1. Standard Memory Mapping & PLC Configuration The configuration the PLC has to implement is as below (for Profibus DP & Profinet IO): Data type Bytes Bits PLC <= CVIxII BYTE 1 8 BYTE 1 8 DOUBLE WORD 4 32 WORD 2 16 DOUBLE WORD 4 32 WORD 2 16 PLC Input Size = 14 bytes PLC => CVIxII BYTE 1 8 BYTE 1 8 PLC Output Size = 02 bytes From CVIxII PLC main screen, press the printer ( standard memory mapping: ) button and down/up arrows to visualize the CVIxII 11/36

12/36 2.5.2. Profibus DP 2.5.2.1. CVIxII Configuration the Profibus Slave Address Ref: 6159275950 AB6422 2.5.2.2. Simatic Step 7 Configuration 12/36

13/36 2.5.3. Profinet IO 2.5.3.1. CVIxII Configuration the IP address the Subnet Mask the Gateway address Ref: 6159275960 Ref: 6159275970 AB6425 AB6431 With firmware versions >= 3.0A, there is the possibility to set the Profinet parameters from the PLC (check the option Set by PLC ) 2.5.3.2. Simatic Step 7 Configuration 13/36

14/36 In order to set the parameters of the Profinet module from the PLC, you must use the tool Edit Ethernet Node included in Siemens Step7 software.(menu PLC => Edit Ethernet Node ) You have to set the IP address and Subnet Mask then click on Assign IP Configuration button. You have also to set the Device Name (which is stored in the station comment) then click on the Assign Name button. The Device name must the same as the one parametered in HW Config (see picture above). N.B: The Device Name defined in Simatic Manager HW Config must be identical to the Station Comment defined in CVIx2 Station parameters. If you use the option Set by PLC, the comment is automatically set with the value sent from the Edit Ethernet Node tool. 14/36

15/36 2.5.4. Device Net 2.5.4.1. CVIxII Configuration the Device Net Slave Address Ref: 6159275990 AB6424 2.5.4.2. RSNetWorx Configuration 15/36

16/36 2.5.5. Ethernet IP 2.5.5.1. CVIxII Configuration the IP address the Subnet Mask the Gateway address Ref: 6159275940 OR AB6423 AB6430 2.5.5.2. RSLogix 5000 Configuration 2.5.5.3. RSNetWorx Configuration 16/36

17/36 2.5.6. CC-Link 2.5.6.1. CVIxII Configuration the CC-Link Slave Address the CC-Link version the number of occupied stations the number of extension cycles (version 2 only) the communication speed (baud rate) Ref: 6159275980 AB6432 With firmware versions >= 4.8Ax and CVIPC2000 >= 4.2.7.x A specific mapping must be created using CVIPC2000. Do not use the standard mapping 2.5.6.2. MELSOFT Configuration 17/36

18/36 3. MULTICVIL II Controllers 3.1. MultiCVIL II - Memory Mapping Table MULTICVIL II PLC Fieldbus MultiCVIL II Memory Address In Bytes In Words Hexa. Deci. Hexa. Deci. Data Description Access (R/W) Size (bytes) Value Type MultiCVIL II - Data Outputs => PLC Inputs 0x0000 0000 0x0000 0000 MultiCVIL II Outputs R 1 Bool 0x0001 0001 0x0000 0000 Selected Cycle (Cycle Echo) R 1 Integer 0x0002 0002 0x0001 0001 List of OK Spindles (Report) R 4 Bool 0x00 00 0x0003 0003 List of NOK Spindles (Report) R 4 Bool MultiCVIL II - Data Inputs <= PLC Outputs 0x0000 0000 0x0000 0000 MultiCVIL II Inputs W 1 Bool 0x0001 0001 0x0000 0000 Cycle Number Selection W 1 Integer 0x0002 0002 0x0001 0001 Spindles Validation W 4 Bool 18/36

19/36 3.2. MultiCVIL II - Inputs & Outputs MultiCVIL II Memory Address In Bytes In Words Hexa. Deci. Hexa. Deci. Data Description Access (R/W) Size (bytes) Value Type MultiCVIL II - Data Outputs => PLC Inputs 0x0000 0000 0x0000 0000 MultiCVIL II Outputs R 1 Bool --- --- --- --- --- --- --- --- MultiCVIL II - Data Inputs <= PLC Outputs 0x0000 0000 0x0000 0000 MultiCVIL II Inputs W 1 Bool --- --- --- --- --- --- --- --- 3.2.1. Inputs & Outputs definition The MultiCVIL II inputs & outputs mapping is defined as below: 3.2.2. Inputs Descriptions Cycle 1/2/4: Binary coded 1-2-4 cycle selection. The Cycle number selection 00 to 07 is only taken into consideration by the MultiCVIL II if the Source of cycle number is set to I/O in the station parameters. Spindle Validation: Error Acknowledge: Start Cycle: Direction: Reset: Allows, or not, the start cycle of the spindle(s). The spindle validation input is only taken into consideration by the multicvil II if the spindle validation source is set to I/O in the station parameters. When the error acknowledgement option is activated in the station parameters, the start of the spindle is not authorized after a reject report. The error acknowledgement input must be validated (pulse) to let the spindle start again. By activating the error acknowledge input, the reject report output is reseted. The tool runs as long as the signal is on 1. When the signal drops, the cycle stops. Activates the untightening direction mode of the spindle at the Start cycle. Reset station tightening reports, all cycles counters, saved barcode. 19/36

20/36 3.2.3. Outputs Descriptions Cycle Echo 1/2/4: Ready: In Cycle: Accept Report: Reject Report: Binary coded 1-2-4 selected cycle echo. The cycle echo is sent back only if it corresponds to a programmed cycle in the station. Otherwise it is at 0. This signal is at 1 when the controller is in working order. Response to the Start Cycle request. Drops to 0 at the end of a tightening or untightening. Active when the cycle is over and the tightening cycle report is OK. Active when the cycle is over and the tightening cycle report is NOK. Number of cycles OK: This signal switches to 1 when the number of cycles run with an Accept Report is equal to the programmed number of cycles OK in the selected cycle parameters. For detailed information, please read the MultiCVIL II controller manual. 20/36

21/36 3.3. MultiCVIL II - Cycle Selection MultiCVIL Memory Address In Bytes In Words Hexa. Deci. Hexa. Deci. Data Description Access (R/W) Size (bytes) Value Type MultiCVIL II - Data Outputs => PLC Inputs --- --- --- --- --- --- --- --- 0x0001 0001 0x0000 0000 Selected Cycle (Cycle Echo) R 1 Integer --- --- --- --- --- --- --- --- MultiCVIL II - Data Inputs <= PLC Outputs --- --- --- --- --- --- --- --- 0x0001 0001 0x0000 0000 Cycle Number Selection W 1 Integer --- --- --- --- --- --- --- --- 3.3.1. Cycle number selection The Cycle number selection is only taken into consideration by the MultiCVIL II if the Source of cycle number is set to PLC in the controller station parameters. The cycle number selection range is between 1 & 31 (0 = no cycle selection). 3.3.2. Selected Cycle (Cycle Echo) This byte indicates the number of the selected cycle in the MultiCVIL II controller. The selected cycle echo range is between 0 & 31 (0 = no cycle selected). 21/36

3.4. MultiCVIL II - List of OK & NOK Spindles Report 22/36 MultiCVIL II Memory Address In Bytes In Words Hexa. Deci. Hexa. Deci. Data Description Access (R/W) Size (bytes) Value Type MultiCVIL II - Data Outputs => PLC Inputs --- --- --- --- --- --- --- --- 0x0002 0002 0x0001 0001 List of OK Spindles (Report) R 4 Bool 0x00 00 0x0003 0003 List of NOK Spindles (Report) R 4 Bool The OK & NOK Spindles lists are 32 bits long each (double words). Each bit corresponds to one spindle. List of Spindles OK / NOK Bit Nb Description Double Word MSB LSB MSB LSB 00 Spindle 01 01 Spindle 02 02 Spindle 03 03 Spindle 04 04 Spindle 05 05 Spindle Spindle 07 07 Spindle 08 08 Spindle 09 09 Spindle 10 10 Spindle 11 11 Spindle 12 12 Spindle 13 13 Spindle 14 14 Spindle 15 15 Spindle 16 00 Spindle 17 01 Spindle 18 02 Spindle 19 03 Spindle 20 04 Spindle 21 05 Spindle 22 Spindle 23 07 Spindle 24 08 Spindle 25 09 Spindle 26 10 Spindle 27 11 Spindle 28 12 Spindle 29 13 Spindle 30 14 Spindle 31 15 Spindle 32 22/36

3.5. MultiCVIL II - Spindles Validation 23/36 MultiCVIL II Memory Address In Bytes In Words Hexa. Deci. Hexa. Deci. Data Description Access (R/W) Size (bytes) Value Type MultiCVIL II - Data Inputs <= PLC Outputs --- --- --- --- --- --- --- --- 0x0002 0002 0x0001 0001 Spindles Validation W 4 Bool The spindles validation is only taken into consideration by the MultiCVIL II if the Spindle validation source is set to PLC in the controller station parameters. This spindles validation list is a 32 bits long word (double word). Each bit corresponds to one spindle. Spindles Validation - Double Word Bit Nb Description Status ON (1) OFF (0) 00 Spindle 01 Enable Disable 01 Spindle 02 Enable Disable Double Word LSB MSB LSB MSB 02 Spindle 03 Enable Disable 03 Spindle 04 Enable Disable 04 Spindle 05 Enable Disable 05 Spindle Enable Disable Spindle 07 Enable Disable 07 Spindle 08 Enable Disable 08 Spindle 09 Enable Disable 09 Spindle 10 Enable Disable 10 Spindle 11 Enable Disable 11 Spindle 12 Enable Disable 12 Spindle 13 Enable Disable 13 Spindle 14 Enable Disable 14 Spindle 15 Enable Disable 15 Spindle 16 Enable Disable 00 Spindle 17 Enable Disable 01 Spindle 18 Enable Disable 02 Spindle 19 Enable Disable 03 Spindle 20 Enable Disable 04 Spindle 21 Enable Disable 05 Spindle 22 Enable Disable Spindle 23 Enable Disable 07 Spindle 24 Enable Disable 08 Spindle 25 Enable Disable 09 Spindle 26 Enable Disable 10 Spindle 27 Enable Disable 11 Spindle 28 Enable Disable 12 Spindle 29 Enable Disable 13 Spindle 30 Enable Disable 14 Spindle 31 Enable Disable 15 Spindle 32 Enable Disable 23/36

24/36 3.6. MultiCVIL II - PLC configuration 3.6.1. Standard Memory Mapping & PLC Configuration The configuration the PLC has to implement is as below (for Profibus DP & Profinet IO): Data type Bytes Bits PLC <= MultiCVIL II BYTE 1 8 BYTE 1 8 DOUBLE WORD 4 32 DOUBLE WORD 4 32 PLC Input Size = 10 bytes PLC => MultiCVIL II BYTE 1 8 BYTE 1 8 DOUBLE WORD 4 32 PLC Output Size = bytes From MultiCVIL II PLC main screen, press the printer ( MultiCVIL II standard memory mapping: ) button and down/up arrows to visualize the 24/36

25/36 3.6.2. Profibus DP 3.6.2.1. MultiCVIL II Configuration the Profibus Slave Address Ref: 6159275950 AB6422 3.6.2.2. Simatic Step 7 Configuration 25/36

26/36 3.6.3. Profinet IO 3.6.3.1. MultiCVIL II Configuration the IP address the Subnet Mask the Gateway address Ref: 6159275960 Ref: 6159275970 AB6425 AB6431 3.6.3.2. Simatic Step 7 Configuration N.B: The Device Name defined in Simatic Manager HW Config must be identical to the Station Comment defined in CVI Station parameters. 26/36

27/36 3.6.4. Device Net 3.6.4.1. MultiCVIL II Configuration the Device Net Slave Address Ref: 6159275990 AB6424 3.6.4.2. RSNetWorx Configuration 27/36

28/36 3.6.5. Ethernet IP 3.6.5.1. MultiCVIL II Configuration the IP address the Subnet Mask. the Gateway address Ref: 6159275940 OR AB6423 AB6430 3.6.5.2. RSLogix 5000 Configuration 3.6.5.3. RSNetWorx Configuration 28/36

4. Appendix 4.1. CVIx II - plugged Module Status 29/36 From the CVIx II PLC parameters screen, press the printer ( the controller module Status Info : ) button and left / right arrows to visualize ST = Module Status: - ST:0000, Module initialisation. - ST:0001, Network / Fieldbus initialisation. - ST:0002, Module is waiting for communication process with PLC. - ST:0003, PLC is in Stop mode or PLC requests module to go in IDLE mode. - ST:0004, PLC & Module communication is ok. - ST:0005, Network / Fieldbus fault. - ST:0007, Fatal Error. 29/36

30/36 4.2. Modules Details 4.2.1. Profibus DP Module # Item 1 Operation Mode 2 Status 3 PROFIBUS Connector 5 1 1 2 3 9 6 Operation Mode State Indication Comments Off Not online / No power - Green On-line, data exchange - Flashing Green On-line, clear - Flashing Red (1 flash) Parametrization error - Flashing Red (2 flashes) PROFIBUS Configuration error - Status State Indication Comments Off No power or not initialized State = SETUP or INIT Green Initialized Module has left the INIT state Flashing Green Initialized, diagnostic event(s) present Extended diagnostic bit is set Red Exception error State = EXCEPTION PROFIBUS Connector (DB9F) Pin Signal Description 1 - - 2 - - 3 B Line Positive RxD/TxD, RS485 level 4 RTS Request to send 5 GND Bus ground (isolated) 6 +5V Bus Output a +5V termination power (isolated, short-circuit protected) 7 - - 8 A Line Negative RxD/TxD, RS485 level 9 - - Housing Cable Shield Internally connected to the module protective earth via cable shield filters according to the PROFIBUS standard. 30/36

31/36 4.2.2. Profinet IO Module # Item 1 Network Status LED 2 Module Status LED 3 Link/Activity LED 4 Ethernet Interface 1 8 1 2 4 3 Network Status LED Note: A test sequence is performed on this LED during startup. LED State Description Comments Off Offline - No power - No connection with PLC Green Online (RUN) - Connection with PLC established - PLC in RUN state Green, flashing Online (STOP) - Connection with PLC established - PLC in STOP state Module Status LED Note: A test sequence is performed on this LED during startup. LED State Description Comments Off Not Initialized No power - or - Module in SETUP or INIT state Green Normal Operation Module has shifted from the INIT state Green, 1 flash Diagnostic Event(s) Diagnostic event(s) present Green, 2 flashes Blink Used by engineering tools to identify the node on the network Red Exception Error Module in state EXCEPTION Red, 1 flash Configuration Error Expected Identification differs from Real Identification Red, 2 flashes IP Address Error IP address not set Red, 3 flashes Station Name Error Station Name not set Red, 4 flashes Internal Error Module has encountered a major internal error LINK/Activity LED LED State Description Comments Off No Link No link, no communication present Green Link Ethernet link established, no communication present Green, flickering Activity Ethernet link established, communication present Ethernet Interface The ethernet interface operates at 100Mbit, full duplex, with auto-negotiation enabled as default. 31/36

32/36 4.2.3. Profinet IO 2 ports Module # Item 1 Network Status LED 2 Module Status LED 3 Ethernet (port 1) 4 Ethernet (port 2) 5 Link/Activity LED (port 1) 6 Link/Activity LED (port 2) 5 6 1 2 3 4 Network Status LED Note: A test sequence is performed on this LED during startup. LED State Description Comments Off Offline - No power - No connection with PLC Green Online (RUN) - Connection with PLC established - PLC in RUN state Green, flashing Online (STOP) - Connection with PLC established - PLC in STOP state Module Status LED Note: A test sequence is performed on this LED during startup. LED State Description Comments Off Not Initialized No power - or - Module in SETUP or INIT state Green Normal Operation Module has shifted from the INIT state Green, 1 flash Diagnostic Event(s) Diagnostic event(s) present Green, 2 flashes Blink Used by engineering tools to identify the node on the network Red Exception Error Module in state EXCEPTION Red, 1 flash Configuration Error Expected Identification differs from Real Identification Red, 2 flashes IP Address Error IP address not set Red, 3 flashes Station Name Error Station Name not set Red, 4 flashes Internal Error Module has encountered a major internal error LINK/Activity LED LED State Description Comments Off No Link No link, no communication present Green Link Ethernet link established, no communication present Green, flickering Activity Ethernet link established, communication present Ethernet Interface The ethernet interface operates at 100Mbit, full duplex, as required by PROFINET. 32/36

33/36 4.2.4. Device Net Module # Item 1 Network Status LED 2 Module Status LED 3 DeviceNet Connector 1 2 3 1 5 Network Status State Indication Off Not online / No power Green On-line, one or more connections are established Flashing Green (1 Hz) On-line, no connections established Red Critical link failure Flashing Red (1 Hz) One or more connections timed-out Alternating Red/Green Self test Module Status State Indication Off No power Green Operating in normal condition Flashing Green (1 Hz) Missing or incomplete configuration, device needs commissioning Red Unrecoverable Fault(s) Flashing Red (1 Hz) Recoverable Fault(s) Alternating Red/Green Self test DeviceNet Connector This connector provides DeviceNet connectivity. Pin Signal Description 1 V- Negative bus supply voltage 2 CAN_L CAN low bus line 3 SHIELD Cable shield 4 CAN_H CAN high bus line 5 V+ Positive bus supply voltage 33/36

34/36 4.2.5. Ethernet IP Module # Item 1 Network Status LED 2 Module Status LED 1 8 1 2 4 3 3 Link/Activity 4 Ethernet Interface Network Status LED Note: A test sequence is performed on this LED during startup. LED State Description Off No power or no IP address Green On-line, one or more connections established (CIP Class 1 or 3) Green, flashing On-line, no connections established Red Duplicate IP address, FATAL error Red, flashing One or more connections timed out (CIP Class 1 or 3) Module Status LED Note: A test sequence is performed on this LED during startup. LED State Off Green Green, flashing Red Red, flashing Description No power Controlled by a Scanner in Run state Not configured, or Scanner in Idle state Major fault (EXCEPTION-state, FATAL error etc.) Recoverable fault(s) LINK/Activity LED LED State Off Green Green, flickering Description No link, no activity Link established Activity Ethernet Interface The ethernet interface supports 10/100Mbit, full or half duplex operation. 34/36

35/36 4.2.6. Ethernet IP 2 ports Module # Item 1 Network Status LED 2 Module Status LED 3 Ethernet Interface, Port 1 4 Ethernet Interface, Port 2 5 Link/Activity Port 1 6 Link/Activity Port 2 5 6 1 2 3 4 Network Status LED Note: A test sequence is performed on this LED during startup. LED State Description Off No power or no IP address Green On-line, one or more connections established (CIP Class 1 or 3) Green, flashing On-line, no connections established Red Duplicate IP address, FATAL error Red, flashing One or more connections timed out (CIP Class 1 or 3) Module Status LED Note: A test sequence is performed on this LED during startup. LED State Off Green Green, flashing Red Red, flashing Description No power Controlled by a Scanner in Run state Not configured, or Scanner in Idle state Major fault (EXCEPTION-state, FATAL error etc.) Recoverable fault(s) LINK/Activity LED 3/4 LED State Off Green Green, flickering Yellow Yellow, flickering Description No link, no activity Link (100 Mbit/s) established Activity (100 Mbit/s) Link (10 Mbit/s) established Activity (10 Mbit/s) Ethernet Interface The ethernet interface supports 10/100Mbit, full or half duplex operation. 35/36

36/36 4.2.7. CC-Link Module 36/36