QuickSpecs. HPE Rackmountable 3 Phase Uninterruptible Power Systems. Overview. (UPS R8000/3 and R12000/3)

Similar documents
HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

R/T2000 G2 HP R/T 2200 UPS INTL HP R/T 2200 UPS JPN/TWN

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models. Overview. Retired

QuickSpecs HP T750 UPS. Overview

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

QuickSpecs HP R3000 UPS. Overview

HP Uninterruptible Power Supplies Overview

T1000 G2 and T1500 G2 1. Battery Compartment 1. Battery Compartment 2. LED display 2. LED display HP T1500 UPS INTL HP T1500 UPS JPN/TWN

QuickSpecs. R7000 Uninterruptible Power System (UPS) Overview

QuickSpecs. HP Tower UPS T750 G2, T1000 G3, T1500 G3 Overview

QuickSpecs. R5000 Uninterruptible Power System (UPS) Overview

QuickSpecs. HP Parallel 3 Phase Uninterruptible Power Systems. Overview

QuickSpecs. HP R1500 G3 Uninterruptible Power Supply (UPS) Overview

HP UPS R1500 XR. Overview

QuickSpecs. HP R1500 G3 Uninterruptible Power Supply (UPS) Overview. Retired

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HPE Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

The HPE Server Console Switch with Virtual Media is backwards compatible with all HPE Cat5 based Server Console Switches and interface adapters.

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

QuickSpecs. Models HP UPS R3000 XR. Overview

QuickSpecs. HPE Standard Power Supplies. Overview. HPE Standard Power Supplies

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

QuickSpecs. HPE KVM IP Console Switch. Overview

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)

QuickSpecs. HPE Flexible Slot Power Supplies. Overview

QuickSpecs. HPE Basic Power Distribution Units (PDU) Overview

QuickSpecs. HPE Synergy Interconnect Link Cable. Overview

QuickSpecs. HPE UPS Network Module. Overview. Models HPE UPS Network Module Mini-slot Kit

UPS R12000 XR, N+X. Overview

QuickSpecs. HPE BladeSystem c-class 40G QSFP+ to QSFP + Direct Attach Copper Cable. Overview

HPE Line Interactive Single Phase Uninterruptible Power Systems (UPS) HPE R1500 G4 JP/TWN Uninterruptible Power System

Retired. Is backup power creating cost and space issues in your data center racks?

HPE T1500 Gen5 NA/JP UPS with Management Card Slot HPE T1500 Gen5 INTL UPS with Management Card Slot

QuickSpecs. HPE Serial Console Server. Overview

HP G4 Line Interactive Single Phase Uninterruptible Power Systems (UPS)

QuickSpecs. HPE IP KVM Console Switch G2 with Virtual Media & CAC. Overview

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

HPE recommended options have best performance, value and availability.

QuickSpecs. HPE IP KVM Console Switch G2 with Virtual Media & CAC. HPE IP KVM Console Switch G2 with Virtual Media & CAC. Overview

QuickSpecs. HPE Synergy QSFP+ Transceiver. Overview. HPE Synergy QSFP+ Transceiver. Page 1

QuickSpecs. HPE Common Slot Power Supplies. Overview

QuickSpecs. HPE Single Phase Tower UPS. Overview and Models. HPE Single Phase Tower Uninterruptible Power Systems (UPS) Why HPE Tower UPS solutions?

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

QuickSpecs. HPE Apollo 6000 Power Shelf. Overview

QuickSpecs. HPE Line Interactive Single Phase Uninterruptible Power System. Overview and Models. Why HPE Tower UPS solutions?

QuickSpecs. HPE G2 Metered Power Distribution Units. Overview HPE G2 Metered Power Distribution Units

QuickSpecs HP BladeSystem Breaker Panel

The HP Server Console Switch with Virtual Media is backwards compatible with all HP Cat5 based Server Console Switches and interface adapters.

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

QuickSpecs. HPE IP KVM Console Switch G2 with Virtual Media & CAC. Overview

16-Port Serial Console Server. 48-Port Serial Console Server

QuickSpecs. Why do you need a KVM Console for your rack? Why HP? HP KVM Console Kit. Overview

Premium Online Series

Retired. HP TFT7600 Rackmount Keyboard and Monitor (TFT7600 RKM) Overview

QuickSpecs. HP TFT7600 G2 KVM Console and Monitor (TFT7600 G2) Overview

QuickSpecs. HP IP Console Switch with Virtual Media Overview

QuickSpecs. HP Server Console Switches Overview

QuickSpecs. HP Modular Cooling System. Overview

QuickSpecs. What's New New USB interface adapter compatible with CAC and virtual media. HP KVM Server Console Switch G2 with Virtual Media & CAC

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

HP 9.5mm SATA DVD RW Optical Drive

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

New G2 features allow for greater management of power and environment in IT racks

Powering HP BladeSystem c7000 Enclosures

QuickSpecs HP Rack 5642

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

QuickSpecs. HP IP Console Switch G2 with Virtual Media & CAC. Overview

QuickSpecs. HPE 10GbE Pass-Thru Module. Overview. What's New. At A Glance

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

QuickSpecs. HPE H220 Host Bus Adapter. Overview. Model Host Bus Adapter HP H220 Host Bus Adapter B21

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview. HP 6G SATA SmartDrive Carriers

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

QuickSpecs. HPE Ethernet 1Gb 2-port 332T Adapter

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

HPE HDD portfolio: Proven performance for every workload Class Enterprise Midline Entry* Workload High Medium Low

UPS Series. features: uninterruptible power supply. what great systems are built on.

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

Setting new standards for reliable power distribution and metering

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

QuickSpecs. HPE Ethernet 1Gb 2-port 332T Adapter. Overview

QuickSpecs. HPE SATA Hard Drives. Overview. HPE Hard Disk Drives

NOTE: Beginning LATE May 2005, the HP R5500 XR UPS is qualified for use on HP9000 and Integrity Servers. Description

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

HPE HDD portfolio: Proven performance for every workload Class Enterprise Midline Entry* Workload High Medium Low

QuickSpecs HP Power Manager 4.2

QuickSpecs. What's New Updating list of supported servers. HP Half-Height SATA DVD ROM Optical Drive. Overview

Transcription:

Overview (UPS R8000/3 and R12000/3) Crowded data centers and racks filled to capacity with storage devices, monitors, servers, communications devices, and other equipment are driving the need for uninterruptible power with increased power density and power efficiency. The HPE 3 Phase Uninterruptible Power Systems provide just that. These rack-mountable Uninterruptible Power Systems provide up to 12,000 watts (W) of power in a 6-U rack form factor. This equates to 2 KW per U space, which leads the industry in power density. The UPS R8000/3 and the R12000/3 use digital signal processing and a new On-line On Demand hybrid technology to answer the demands for increased power density and power efficiency. On-line On Demand combines the efficiency of a line interactive UPS, up to 97%, with the stability of a double conversion on-line UPS when power fluctuates beyond acceptable limits. Hot swappable batteries and electronics modules and an automatic bypass reduce MTTR (mean time to repair) down time in the event service is needed. UPS R8000/3 and R12000/3 front view UPS R8000/3 and R12000/3 rear view 1. Battery compartment (behind bezel) 1. Communications terminal block 2. Menu navigation buttons 2. Output circuit breaker 3. Status and alarm LED display 3. Input circuit breaker 4. Electronics module compartment (behind bezel) 4. Battery circuit breaker 5. Input/output location R8000/3, input location R12000/3 1 6. ERM connector 7. Option card slots 8. Output connector R12000/3 9. Ground bonding screw 10. DB9 Service port 11. REPO port Models Extended Options provide an extended catalog of products tailored for customers in specific markets or with specific workloads, requiring the utmost in performance or value. Fully integrated into the HPE management and security experience, Extended Options represent great value and performance but typically have a longer lead-time. Page 1

Overview HPE R8000/3 HPE R8000/3 8000kVA Three Phase NA 6U Rackmount Uninterruptible Power System (Extended) HPE R8000/3 8000kVA Three Phase INTL 6U Rackmount Uninterruptible Power System (Extended) HPE R12000/3 HPE R12000/3 12000VA Three Phase NA 6U Rackmount Uninterruptible Power System (Extended) HPE R12000/3 12000VA Three Phase INTL 6U Rackmount Uninterruptible Power System (Extended) AF431A AF432A AF429A AF430A Page 2

Standard Features Key Features Unity Rated, volt amperage out equals wattage out Highest wattage per U space. Up to 12000 VA/12KW in only 6U Industry leading efficiency with On-line On Demand hybrid technology Attached line cords for easier and faster connection to your facility power Hot-swappable battery and electronics modules provide ease of maintenance and faster time to repair (MTTR) Industry leading efficiency with On-line On Demand hybrid technology Attached line cords for easier and faster connection to your facility power Extra-long battery life with Enhanced Battery Management (EBM) Extended battery run time with optional Extended Runtime Modules (ERMs) Easy configuration through enhanced front panel display or HPE UPS Management Module (included) Backed by a limited three-year warranty, the Hewlett Packard Enterprise pre-failure warranty and a load protection guarantee in North America Superior Battery Management HPE UPS HPE 3 Phase UPS incorporates Enhanced Battery Management: an exclusive, patented technology that doubles battery service life, optimizes battery recharge time, and provides advance notice of pending battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and receive the best in the industry protection for your critical equipment. Ease of serviceability through hot-swappable batteries and electronics modules. Increase battery back-up time with up to four Extended Runtime Modules The HPE 3 Phase UPSs have a modular design architecture, consisting of separate, hot swappable battery and electronics modules. Further, a built-in intelligent automatic bypass feature ensures continuous power to your connected load even while the modules are being replaced. Ease of maintenance and serviceability Faster time to repair (MTTR) Automatic and manual bypass Increased flexibility through modular design HPE 3 Phase UPS supports a maximum of four Extended Runtime Modules (ERM), to further increase your battery back-up time, should you have a sudden brief power outage. Each ERM is 3U high and can be automatically detected and configure when attached to the UPS. For more information on battery backup times, please refer to the Back-up Times Chart. Multiple management options increase flexibility Remote Emergency Power Off Feature UPS Management Module The HPE 3 Phase UPS systems can be fully configured and monitored from the front management LCD. For remote management the HPE UPS Management Module is included at no charge and provides additional features such as out of band communications with up to 5 servers and UPS clustering for redundancy. The HPE 3 Phase UPS includes an isolated REPO (Remote Emergency Power Off) port. The REPO feature allows the power to the UPS outlets to be switched off from a remote location. For more information, refer the HPE 3 Phase UPS user s manual. The HPE UPS Management Module enables you to monitor and manage power environments through comprehensive control of HPE UPSs. The HPE UPS Management Module can support either a single UPS configuration or provides additional power protection with support for dual redundant UPS configuration for no-single-point-of-failure. The additional serial ports will provide greater power management control and flexible monitoring. The management module can be configured to send alert traps to HPE Systems Insight Manager and other SNMP management programs or used as a standalone management system. This flexibility Page 3

Standard Features enables you to monitor and manage UPSs through the network. To facilitate day-to-day maintenance tasks, the embedded management software provides detailed system logs. The HPE UPS Management Module provides remote management of a UPS by connecting the UPS directly to the network. Configuration & Management of the UPS from anywhere and at any time via a standard web browser. NOTE: For more information on the UPS Management Module please see: https://www.hpe.com/us/en/integrated-systems/rack-power-cooling.html Warranty Standard three year warranty with first year including parts and labor. HPE UPSs are backed by a standard three year limited warranty; 3 year parts, 1 year Labor, 1 year onsite. Optional UPS packaged services are also available for purchase. You can choose the precise level of support based on your needs, from basic to business critical. Pre-Failure Battery Warning and its associated Warranty. The Pre-Failure Battery Warning is proactively detected and notified by a LED indicator light, showing that the battery needs to be replaced. This notice is given 30 days prior to the battery failure. This indicator provides ample time to order a spare battery Avoid storing battery spares as a backup because of short shelf life of the battery. The battery warranty coverage is 3 years for parts. The warranty for the first year of ownership includes parts and labor. Warranty, standard on all HPE Uninterruptible Power System (UPS) units, extends the advantage of a HPE three-year limited warranty by applying it to the battery before it actually fails. Specifically, the Pre-Failure Battery Warranty ensures that when customers receive the notification from their HPE UPS that the battery may fail, the battery is replaced free of charge under the warranty. Hewlett Packard Enterprise maintains the highest standards in the industry, as evidenced by the HPE Pre-Failure Battery Warranty. In addition, HPE UPSs are covered by a $250,000 equipment protection guarantee. Should your connected equipment get damaged due to a UPS failure, then your damaged equipment is covered to up to $250,000. NOTE: The $250,000 Equipment Protection Guarantee is offered only in North America. Page 4

Service and Support HPE Pointnext operational services Parts and Materials HPE Pointnext operational services include Hewlett Packard Enterprise branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the enclosure, as well as 22" and smaller external monitors and rack mounted UPS options. HPE Uninterruptible Power Systems will be covered at the same service level and coverage period as the server. For servers or storage systems installed within a rack, service also covers all HPE qualified rack options installed within the same rack. NOTE: For more information on HPE Pointnext operational services, contact any of our worldwide sales offices or resellers or visit our worldwide Web site on the internet at: http://h20565.www2.hpe.com/portal/site/hpsc/ NOTE: For more complete information on HPE Services offerings, customers and resellers, please visit us at: https://www.hpe.com/us/en/support.html NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h20564.www2.hpe.com/hpsc/wc/public/home NOTE: The information contained herein is subject to change without notice and is provided "as is" without warranty of any kind. NOTE: The warranties for Hewlett Packard Enterprise products and services are set forth in the express limited warranty statements accompanying such products and services. Hewlett Packard Enterprise will provide HPE-supported replacement parts and materials necessary to maintain the covered hardware product in operating condition, including parts and materials for available and recommended engineering improvements. Parts and components that have reached their maximum supported lifetime and/or the maximum usage limitations as set forth in the manufacturer's operating manual, product quick-specs, or the technical product data sheet will not be provided, repaired, or replaced as part of these services. The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives replaced by Hewlett Packard Enterprise due to malfunction. Page 5

Related Options UPS Management Module Extended Runtime Module Serial Adapters for UPS Management Module HPE Management Card for XR UPS NOTE: The HPE UPS Management Module provides remote management of a UPS by connecting the UPS directly to the network. Configuration & Management of the UPS from anywhere and at any time via a standard web browser. HPE UPS R8000/3 R12000/3 Extended Runtime Module (Extended) NOTE: HPE 3 PHASE UPS supports a maximum of four Extended Runtime Modules (ERM), to further increase your battery back-up time. Each ERM is 3U high and can be automatically detected and configure when attached to the UPS. For more information on battery backup times, please refer to the Back-up Times Chart. HPE RJ45-DB89 DCE Female 5 Pack Serial Adapter NOTE: The serial adapters allow direct (serial) connections to up to 5 servers with the UPS Management Module for out of band communications in the event of a power failure. AF401A AF434A AF402A HPE Power Cables HPE C13 - C14 WW 250V 10Amp 1.4m Jumper Cord (Recommended) 142257-006 HPE C13 - C14 WW 250V 10Amp 0.7m Jumper Cord (Recommended) 142257-B28 HPE C19 - C20 WW 250V 16Amp 2.5m Jumper Cord (Extended) 295633-B22 HPE C19 - C20 WW 250V 16Amp Flint Gray 2.0m Jumper Cord (Extended) AF574A HPE C19 - C20 WW 250V 16Amp Flint Gray 1.20m Jumper Cord (Extended) AF575A NOTE: For more information on HPE power cords please go to: https://h20195.www2.hpe.com/v2/getpdf.aspx/4aa6-6836enw.pdf HPE Pointnext operational services HPE Install Universal Power Supply 6KVA or Greater Service U4696E Page 6

Technical Specifications R8000/3 NA R8000/3 INTL R12000/3 NA R12000/3 INTL Electrical Output Power Output 8kVA/8KW @ 8kVA/8KW @ 12kVA/12KW @ 12kVA/12KW @ 208v 3Φ Delta 400v 3Φ Wye 208v 3Φ Delta 400v 3Φ Wye Nominal output 50-60 Hz auto-detection (Normal mode) frequency 50 or 60 Hz (Battery mode) Output Frequency Synchronized (Normal mode) Variation ±0.1 when not synchronized with source (Battery mode) Output overload 100 110%: load transfers to Bypass mode after 10 minutes 110 125%: load transfers to Bypass mode after 1 minute 125 150%: load transfers to Bypass mode after 5 seconds >150%: load transfers to Bypass mode after 300 ms Voltage wave form Sine wave; 2% THD with typical PFC load Surge suppression High-energy 6500 A peak Noise filtering MOVs and line filter Output Connections One NEMA L15-30R One IEC309 516C6 (16A) Two NEMA L15-30R Two IEC309 516C6 (16A) Electrical Input Voltage Range 200-240 v 3Φ 380-415v 3Φ 208v 3Φ Wye 380-415v 3Φ Wye Wye Wye Nominal voltage 208v 3Φ Wye 400v 3Φ Wye 208v 3Φ Wye 400v 3Φ Wye Nominal frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Frequency range 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz Efficiency 97% @ 40-100% 97% @ 40-100% 97% @ 40-100% 97% @ 40-100% load load load load Input connector NEMA L21-30 IEC309 516P6 IEC309 560P9 IEC309 532P6 (30A) (16A) (60A) (32A) Operating Temperature Operating Temperature 50 F to 104 F (10 C to 40 C) Optimal battery 41 F to 77 F (5 C to 25 C) performance Non-operating -13 F to 131 F (-25 C to 55 C) Temperature Relative Humidity Operating 5% to 95% non-condensing Operating Altitude Up to 3300 ft (1,000 meters) above sea level; up to 6600 ft (2,000 meters) with 1% derating per +330 ft (100 meters) Transit Altitude Up to 49,212 ft (15,000 meters) above sea level Heat Dissipation 1266 BTU/hr maximum at 100% rated load (High Efficiency mode) Audible Noise Less than 50 dba at 1 meter (Normal mode) Less than 55 dba at 1 meter (Battery mode) Leakage Current < 3.5 ma Surge suppression ANSI C62.41 Category B3 Page 7

Technical Specifications Safety Conformance UL 1778 4th EN and IEC UL 1778 4th EN and IEC edition; CSA 62040-1-1 edition; CSA 62040-1-1 C22.2, No. 107.3 C22.2, No. 107.3 EMC (Class A) FCC Part 15 EN 62040-2 FCC Part EN 62040-2 Unit Dimensions 14.4 x 26 x 10.3 in (441 x 660 x 261 mm) 6U (WxDxH) Shipping Dimensions 25 x 38 x 46 in (635 x 965 x 1169 mm) (WxDxH) Unit Weight Without batteries 135 lb (61 kg) With batteries installed 307 lb (140 kg) Shipping Weight Extended Runtime Module (ERM) 400 lbs (182 kg) Unit Dimensions (WxDxH) Shipping Dimensions (WxDxH) Unit Weight Shipping Weight 17.2 x 26 x 5.2 in (438 x 660 x 131 mm) 3U 47.25 x 31.5 x 37 in (1207 x 800 x 940 mm) 170 lbs (77 kg) 185 lb (84 kg) Estimated Backup Times Chart (Minutes) R8000/3 Load Watts With Internal Battery With 1 ERM With 2 ERMs With 3 ERMs With 4 ERMs 8000 8.7 17.7 27.9 43.0 54.7 7000 10.7 22.8 32.4 50.1 63.9 6000 13.6 26.9 41.8 59.8 76.4 5000 18.5 32.8 51.3 73.4 94 4000 23.0 41.5 65.5 94.1 120 3000 30.4 56.0 89.3 128 165 2000 44.0 85.1 137 199 258 Estimated Backup Times Chart (Minutes) R12000/3 Load Watts With Internal Battery With 1 ERM With 2 ERMs With 3 ERMs With 4 ERMs 12000 4.7 9.5 17.3 27.0 34.2 11000 5.4 10.9 19.8 29.8 37.8 10000 6.2 12.6 21.7 33.3 42.2 9000 7.3 14.8 24.4 37.5 47.7 8000 8.7 17.7 27.9 43.0 54.7 7000 10.7 22.8 32.4 50.1 63.9 6000 13.6 26.9 41.8 59.8 76.4 5000 18.5 32.8 51.3 73.4 94 4000 23.0 41.5 65.5 94.1 120 3000 30.4 56.0 89.3 128 165 2000 44.0 85.1 137 199 258 NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions. Environment-friendly Products and Approach- Hewlett Packard Enterprise offers end-of-life Hewlett Packard Enterprise product return, trade-in, and recycling programs in many geographic areas for our products Page 8

Technical Specifications End-of-life Management and Recycling The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard Enterprise web site.these instructions may be used by recyclers and other WEEE treatment facilities as well as Hewlett Packard Enterprise OEM customers who integrate and resell Hewlett Packard Enterprise equipment. Page 9

Summary of Changes Date Version History Action Description of Change 02-Jul-2018 Version 12 Changed SKU descriptions were updated. 23-Oct-2017 Version 11 Changed Care Pack naming and Service and Support- Parts and Materials updated. 27-May-2016 Version 10 Changed Technical Specifications section was revised. 16-Feb-2016 Version 9 Changed Overview, Standard Features, and Related Options were revised. 20-Jun-2011 Version 8 Changed Models and Related Options product descriptions were revised Key Features and Warranty were moved into Standard Features Product Highlights was changed to Standard Features HPE Care Pack and Warranty Information were removed from Service and Support 21-Jun-2010 Version 7 Removed NOTE was removed from Superior Battery Management. 14-Nov-2008 Version 6 Changed The URL was corrected in UPS Management Module in the Product Highlights section. 18-Dec-2007 Version 5 Changed Change made in the Technical Specifications section only. 14-Dec-2007 Version 4 Added A note was added to the Product Highlights section. 07-Dec-2007 Version 3 Changed Changes were made to the Production Highlights, Warranty and Technical Specifications sections. 13-Nov-2007 Version 2 Changed Changes were made to the Key Features, Production Highlights and Related Options sections. Removed UPS Management Model from Related Options. 12-Nov-2007 Version 1 New QuickSpecs was created. Sign up for updates Copyright 2018 Hewlett Packard Enterprise Development LP. The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein. c04123376-12857 - Worldwide - V12-02-July-2018 Page 10