CT-510. Multifunctional CCTV Tester. User Manual

Similar documents
Safety Information. Introduction. 1.1 Precaution before using the tester. 1.2 Precautions when using the tester

CCTV Tester. User s Manual

CCTV Tester. User s Manual

User s Manual Model: EX-TB2

T1 Professional CCTV Tester / Analyser T Version EN triax.com

USER S MANUAL. CCTV TESTER Model:TM035

INSTRUCTION MANUAL. ST-F35TEST CCTV Test Meter

Content. 1, Safety Information...1

SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS SAFETY INFORMATION... 2 WARNINGS... 28

Distributed by: Made in Korea

USER S MANUAL. CCTV Tester - MC3.5H-BP-PTZ

USER S MANUAL. CCTV TesterPro

USER S MANUAL. CCTV TesterPro. Ver:STPV

USER S MANUAL. CCTV TesterPro

3.5 HVGA TFT-LCD Wide angle screen display/480 (RGB)*320 resolution / AHD TEST /PTZ

Output one channel PAL/NTSC color bar video signal for testing monitor or video cable.(red, green,blue, white and black color )

B-Qtech Electronics Co.,Ltd / USER S MANUAL. CCTV TesterPro. Stest-895. Ver:STPV

Multi-function CCTV Tester. NDAHD-X07UHDRETINA 4K HD IPC Test Monitor. All-in-one CCTV tester

Rapport mini. Multi Functional CCTV Tester P/N : PRINTED IN KOREA SET MODE. Tx Rx PWR CHG COM V/ FAR OPEN TELE OSD NEAR CLOSE WIDE ~ V

Model. True RMSmA Clamp Meter. Instruction Manual

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

Digital Multimeter User's Manual

HD Coaxial Tester Manual V2.10

HD Coaxial Tester Manual V2.10

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

ETHOS Auto Ranging Digital Multimeter

OPERATING INSTRUCTION

2 in 1 LAN Tester and Multimeter Model:

SBS 600. User Manual. Graphical Digital Multi-meter. SBS-600 Users Manual Revision 1.0-5/2014

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

3700 SERIES USER MANUAL

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

TENMA INSTRUCTION MANUAL MULTI-TESTER

DH-PFM900-E Integrated Mount Tester

User Guide True RMS Multimeter Extech EX205T

Professional Pan Tilt Zoom Camera ST-HD-PTZ-2MP INSTALLATION MANUAL

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

Autoranging Mini Multimeter

RS Stock No Instruction Manual RS Input Data Logging Thermometer

5.6" Multi-function Monitor

Model A Mini AC/DC Clamp Meter. User's Guide

True RMS Digital Bench Multimeter Model:

Autoranging True RMS Multimeter User Manual

All in one Multi-functions CCTV tester

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

AutoRanging Digital MultiMeter

DH-PFM906 Integrated Mount Tester

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

4CH MOBILE DVR OPERATING INSTRUCTIONS

TABLE OF CONTENTS Introduction Function Setup Playback Operation

Model R5010. TRMS Digital Multimeter. Instruction Manual

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

7032 Digital-Analog Multimeter

User's Guide. Digital Multimeter. Model MN42

ST-PTZ High-Speed Intelligent Dome PTZ Color Camera

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

7 LCD CCTV Test monitor. Quick guide

Mini Digital Multimeter

Wireless Video Door Phone. User Manual

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

3.5 LCD CCTV Test Monitor ART

MTP INSTRUCTION MANUAL

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Digital Clamp Meter User Manual

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

FastCam Outdoor Speed Dome Camera

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

OPERATION INSTRUCTION

Avonic AV-CON300. PTZ Camera Controller

Bench Multimeter. Users Manual

POCKET MULTIMETER Model No: MM18

Autoranging Multimeter Extech EX503

USER MANUAL. True RMS Multimeter. Extech EX430A

Mini Digital Multimeter

CamView PTZ Instruction Manual

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Industrial Multimeter Extech EX510

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

True RMS Multimeter with IR Thermometer

Wireless TRMS Multimeter and Insulation Tester

User's Guide. MiniTec TM Series Model MN25 MultiMeter

USER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

DC / AC True RMS Watt Clamp DMM

USER'S MANUAL DCL-650

4.3 Testing Analog Cameras

700 Series 200 Amp Clamp Meters

Autoranging Mini Multimeter Model MN16A

the excelptz range Installation and Operation Manual Speed Dome Camera Controller Version 1.0 For updates to these instructions visit

Mini Digital Multimeter Model MN15. User's Guide

The Symphony Keyboard is available with either a 2D or 3D joystick. The 3D Joystick controls zoom in and out, as well as direction.

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patented

IN-CAR HD Digital Video Recorder

HuddlePod Air DUO Dual Wireless Audio Pods Installation and Operation Manual

Transcription:

CT-510 Multifunctional CCTV Tester User Manual Please read these instructions carefully & save this manual for future use

Content 1 Safety information... 1 1.1 Precaution before using the tester... 1 1.2 Precautions when using the tester... 1 1.3 Precautions for battery charging and using... 2 2 Introduction... 2 2.1 Feature and functions... 2 2.2 Specification... 3 3 Operation Instruction... 4 3.1 Power and battery... 4 3.2 Function Key... 5 3.3 Main Menu... 5 3.3.1 System Setup... 5 3.3.2 Video and PTZ Control Menu... 6 3.3.3 Digital Multi-meter... 9 3.3.4 RS485 Data Test... 10 3.3.5 Cable Test...11 3.3.6 Address Searching... 12

1 Safety information 1.1 Precaution before using the tester 1) Please read the user manual before using the product. 2) Please check the input and output range of voltage or current at every input and output ports before connecting, so that the tester can not be overloaded / damaged. 3) Operation environment: Working temperature: -10 C~+60 C (battery discharge) 0 C~+45 C (battery charge) -30 C~+70 C (only for power adaptor) Humidity 30%~90% Voltage: DC9V/2000mA 1.2 Precautions when using the tester 1) Do not use the tester in damp humidity or leaking gas environment. 2) Do not touch the tester with wet hands. 3) Do not shock or shake the tester while in use to avoid damage. 4) Avoid using the tester in the places of strong magnetism or electric wave. 5) Do not expose the ports or joints to dirt or liquid. 6) Do not disassemble the tester. About Digital Multi-meter 1) Before testing, check the connection of probe. 2) When measuring, do not input over maximum limit, or burned. 3) When measuring DC Voltage >60V, AC Voltage >40V should take care, or get a shock. 4) When changing to another test, the probes should leave the tested thing. 5) Prohibit probes measure voltage on current terminal. 1

6) Choose the correct function, do not in wrong operation. 1.3 Precautions for battery charging and using 1) Use only original chargeable battery with the tester, when charge the battery, please use the original power adapter. 2) Make sure not to disorient the polarization of batteries. 3) Do not short-circuit or disassemble batteries. 4) Battery stock environment: -5 C~+45 C, relative humidity: 65±20% RH (within 1 month) -5 C~+35 C, relative humidity: 65±20% RH (within 3months) 0 C~+35 C, relative humidity: 65±20% RH (within 6 months) 5) When the battery needs long-term stock, ensure charging the battery in half capacity (voltage: 7.2~7.8V, capacity display: 50%~75%), then charge and discharge the battery in every 3 months. 2 Introduction 2.1 Feature and functions 1) Video test 3.5 inch LCD screen, display the video signal and the quality of picture. Video signal system PAL/NTSC could be auto suitable. 2) PTZ control The unit has the basic operation test of PTZ products, functions include pan/tilt, zoom in/out, preset setting and operation, auto scanning, speed adjustment etc; support multi-protocol and baud rate, communication via RS485 port. Protocol include: Pelco D/P and so on. 3) DC12V/1A output The CCTV Tester could supply power DC12V/1A to camera. 4) Audio test It can test the audio device when connected the camera. 2

5) UTP cable test The wiring condition (disconnected, short circuit and sequence of UTP cable) can be tested and display on the screen clearly. 6) RS485 data test It can test the RS485 data sent from control device, display the hexadecimal data content for engineer to analyze. 7) Address Search PTZ address scanning, search up the ID of PTZ camera. 8) Digital Multi-meter Digital multi-meter could test voltage, current, resistance and capacitance, continuity, diode and so on. 2.2 Specification Model Multifunctional CCTV Tester Video Signal Test Signal Mode NTSC/PAL automatically suitable Display 3.5 inch LTPS LCD screen, 960x240 resolution Video Input 1 Channel BNC Video Output 1 Channel BNC PTZ Test Communication RS485 PTZ Protocol PELCO P/D and kinds of protocols, special protocol could be customized Other Functions Power Output Supply 12V power to camera Audio Test 1 channel audio signal output, test the sound whether in normal 3

UTP Cable Test Test UTP Cable connection state and display on the screen. RS485 Data Test Test the RS485 data sent from control device. Power Power Adapter DC9V/2A Battery 1600mAH Digital Multi-meter AC/DC Voltage 0~300V AC/DC Current 400.0μA 4000μA 40.00mA 400.0mA 10A Resistance 400.0Ω 4.000K 40.00K 400.0K 4.000M 40.00M Capacitance 4.000nF-400.0μF Diode forward voltage: 0~2V Min resolution: 1mV Continuity <50Ω sound reminder Test Speed 3 seconds at a time Other Parameters Work Temperature -30 C~+70 C Work Humidity 30%~90% Dimension 105*44*188 mm 3 Operation Instruction 3.1 Power and battery 1) First using, recharge it for 3~4 hours when the battery runs down. (Use the original power adapter.) 2) When charging, the battery indicator turns red; the light turns off after the battery is full. 3) When the light indicator turns off, the capacity of the battery is about 4

90%, user could be extended for 1 more hour, but do not charge more than 8 hours once. The tester could work in charging. 4) When the tester abnormal, disconnected all the cables, and press <RESET> key. Restart the tester, it could use in normal. 3.2 Function Key 1) In close state, press <POWER> key 3 seconds to boot. 2) In work state, press <POWER> key 3 seconds to shut down. 3) In any kind of functions state, press <SET> key to set parameters. 3.3 Main Menu Press<POWER>to boot the tester, enter the main menu. Remark: Press direction key (up, down, left and right) to choose the menu, then press <Enter/OPEN> key enters the sub-menu. 3.3.1 System Setup Choose, press <Enter/OPEN> key enter the menu, the menu as below: 5

SYSTEM SETUP PROTOCOL PELCO-D COM 485 BAUD RATE 2400 PTZ SPEED 016 IDLE TIME 000 LANGUAGE ENGLISH KEY VOICE BATTERY 100 VER. V1.0 Setting Parameters: Press <SET> key, then use UP or DOWN direction key to choose the parameter option, use LEFT or RIGHT key revise the parameters, after revise, press <Enter/OPEN> to save the parameters; press <Return/CLOSE> exit the menu. Remark: 1) The battery shows the current capacity, user could not change the data. 2) Version No. could not be changed. 3) PTZ Speed range: 001~016 4) Idle time: 000~010 minutes could be set. In standby status, after 30 minutes, user doesn t operate the tester; it will be shut off automatically. Set 000 means not standby and will be not shut off. 3.3.2 Video and PTZ Control Menu Choose, press <Enter/OPEN> enter the video and PTZ Control menu, when the tester is connected with video, the screen will display the scene of 6

surveillance device. 1) PTZ Control Connected with the surveillance device and tester, UP/DOWN/LEFT/RIGHT direction key control the PTZ camera s direction, <TELE/WIDE> key control Zoom, <FAR/NEAR> key control Focus, <Enter/OPEN> key and <Return/CLOSE> key control Iris. 2) Setting Preset In PTZ Control mode, press <SET> key enter preset setting menu: VIDEO AND PTZ CONTROL SET PRESET 000 Left/Right direction key chooses the preset No. ; < SET>: save the setting and exit the setting menu; <Enter/OPEN>: save the setting but not exit the menu; <Set> +<Enter/OPEN>: back to the main menu. Remark: Press Left/Right direction key not lose, it will diminishing or increasing 10 numbers. Press Up/Down direction key, it will be diminishing or increasing 50 numbers. In this state, user could not control the PTZ and zoom camera. 3) Calling Preset In PTZ Control mode, press <MODE > key enter preset calling menu: VIDEO AND PTZ CONTROL CALL PRESET 000 Left/Right direction key chooses the preset No. ; 7

< MODE>: Calling the preset and exit the menu; <Enter/OPEN>: save the setting but not exit the menu; <MODE > +<Return/CLOSE>: back to the main menu. Remark: Press Left/Right direction key not lose, it will diminishing or increasing 10 numbers. Press Up/Down direction key, it will be diminishing or increasing 50 numbers. In this state, user could not control the PTZ and zoom camera. 4) Setting Protocol, Baud Rate, Address and PTZ Speed In PTZ Control mode, press <MODE > 3 seconds, enter the menu: VIDEO AND PTZ CONTROL PROTOCOL PELCD-D COM 485 BAUD RATE 2400 PTZ SPEED 016 SET ADD 001 PAL/NTSC NULL < SET>: change the parameters; Up/Down direction key choose the <SET ADD>; Left/Right direction key choose the corresponding address parameter; <Enter/OPEN>: save the setting; <MODE>: exit the current setting; <Return/CLOSE>: back to the main menu. Remark: Press Left/Right direction key not lose, it will diminishing or increasing 10 numbers. 8

In this state, user could not control the PTZ and zoom camera. Video signal system is PAL or NTSC auto detected, no video will display NULL. 3.3.3 Digital Multi-meter Choose, press <Enter/OPEN> enter the digital multi-meter menu: 1 AC Voltage 2DC Voltage 3 AC Current (10A) 4AC Current (ma) 5 DC Current (10A) 6 DC Current (ma) 7 Resistance 8Capacitance 9 Diode 10Low Resistance Notice: It is normal that the tester has sound when change the function. 1 AC Voltage Measuring: A. The red test lead to the V/ Ω jack, the black test lead to the COM jack; B. Choose the AC Voltage, and then it could measure. 2 DC Voltage Measuring: A. The red test lead to the V/ Ω jack, the black test lead to the COM jack; B. Choose the DC Voltage, then it could measure. 3 AC Current (10A) Measuring: A. The red test lead to the 10A jack, the black test lead to the COM jack; B. Choose the AC Current (10A), then it could measure. 9

4 AC Current (ma) Measuring: A. The red test lead to the ma jack, the black test lead to the COM jack; B. Choose the AC Current (ma), then it could measure. 5 DC Current (10A) Measuring: A. The red test lead to the 10A jack, the black test lead to the COM jack; B. Choose the DC Current (10A), then it could measure. 6 DC Current (ma) Measuring: A. The red test lead to the ma jack, the black test lead to the COM jack; B. Choose the DC Current (ma), then it could measure. 7 Resistance Measuring: A. The red test lead to the V/ Ω jack, the black test lead to the COM jack; B. Choose Resistance, and then it could measure. 8 Capacitance Measuring: A. The red test lead to the V/ Ω jack, the black test lead to the COM jack; B. Choose Capacitance, and then it could measure. 9 Diode Measuring: A. The red test lead to the V/ Ω jack, the black test lead to the COM jack; B. Choose Diode, and then it could measure. 10 Low Resistance Measuring: A. The red test lead to the V/ Ω jack, the black test lead to the COM jack; B. Choose Low Resistance, and then it could measure. 3.3.4 RS485 Data Test Choose, press <Enter/OPEN> enter the menu, user should set the correct baud rate in system setup menu before using this function. 485 DATA TEST 10

Control the PTZ device sends the RS485 signal to the tester, user could check the data whether you send. 485 DATA TEST FF 01 00 02 40 00 43 FF 01 00 00 00 00 01 FF 01 00 04 40 00 45 FF 01 00 00 00 00 01 3.3.5 Cable Test Choose, press <Enter/OPEN> enter the menu: 1 2 3 4 5 6 7 8 UTP CABLE TEST Connected the UTP Cable, the screen will display the connection sequence: 11

UTP CABLE TEST 1 1 2 X 3 36 4 4 5 5 6 36 7 7 8 8 Left Numbers: Tester UTP CABLE Sequence Right Numbers: 1: testing box cable order X: disconnect 36: 3, 6 short-circuit 3.3.6 Address Searching Under the condition of knowing the protocol and baud rate could search the PTZ Camera address. 1) Choose, press <Enter/OPEN> enter the menu: ADDRESS SEARCH PROTOCOL PELCD-D COM 485 BAUD RATE 2400 START ADD 001 DIRECTION RIGHT AREA 001-255 SEARCH 001 12

<PROTOCOL>: The protocol of control device. <COM>: The communication of control device. <BAUD RATE>: The baud rate of control device. <START ADD>: The start address before searching, range: 000~255 <DIRECTION>: Inspect the camera rotates direction, turn left or right. <AREA>: Search the address range, user could not change. Remark: Protocol, communication, baud rate could not revise in the menu; user could change them in system setup menu. 2) Press <SET>, the number beside the <SEARCH> is blinking. 3) Press<Enter/OPEN>, the number beside the <SEARCH> begin increasing when user found the camera start rotate or stop, press<enter/open>, until the <AREA> address range are the same. For example: <AREA> 007-007, that means the camera address is 007, user could enter the PTZ control menu revise the <SET ADD> number as the same as the searching number to check whether it is correct. Remark: The default searching start address is 001, direction is turn right, user could change it to left/right in a work situation. 4) Change Start Address User could use Up/Down direction key to move the cursor to the <START ADD>, Left/Right direction key choose the parameter, such as 007, then the search area is 007~255, then operate it as the (3) operation. 5) Change Direction User could use Up/Down direction key to move the cursor to the <DIRECTION>, Left/Right direction key choose the parameter, user select the opposite direction according to the PTZ motion state. For example, the PTZ move to left, user should select right, then operate as the (3) operation. 13