User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Similar documents
User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual E-Clipse Bypass Configurations (BCR, BDR, VCR, or VDR) for ACH550 Drives (1 400 HP)

Installation Manual Updated May 2017

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

115/230 VAC Digital Input Module OHDI-01

ACQ550. User s Manual ACQ550-U1 Drives (1 200 hp)

User s Manual ACS Drives ( kw) ACS550-U1 Drives (1 150 HP)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

User s Manual Pulse Encoder Interface Module OTAC-01

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

PowerLogic High Density Metering System 1-Meter Enclosure

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Quick Start Guide TS A

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

Installation Job Aid for Ethernet Routing Switch 3600 Series

Welcome to the Product specification training module for the ACS800-01, ABB Industrial drive.

ACS550 User s Manual ACS Drives ( kw) ACS550-U1 Drives (1 200 hp)

Installation Job Aid for VSP 4450GTX-HT- PWR+

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Table of Contents. Safety. Attention. Warnings

ICS Entrance Management Sign Installation Guide. Version 1.0

Submittal Schedule Details for VFD-P101, P201, P202, P310, P302, P401, P402

DVFP Series Variable Frequency Drive - Product Manual. pg. 1

Series Amp Pad Mount Quick Connect Input and Output Power Panels

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Installation Job Aid for VSP 4850GTS

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

SmartVFD Disconnect Panel Assemblies

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Installation Instructions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ABB wind turbine converters. Supplement ACS slide-out frame (+P919)

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ABB Industrial Pump and Fan AC Drives ACS310, 0.5 to 30Hp (0.37 to 22kW)

ABB Industrial Pump and Fan AC Drives ACS310, 0.5 to 30Hp (0.37 to 22kW)

PowerFlex 400 AC Drive Guide Specification

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Custom Controller Installation Instructions

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Specifications, Installation, and Operating Instructions

P216 Series Condenser Fan Speed Controller

MAXIMA+ Series Rotary Level Indicator

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Analog Monitor Installation Manual

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Series Amp Quick Connect Input and Output Power Panels

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

PGR-3200 MANUAL INSULATION MONITOR

Power Supply (48Vdc, 2.5A)

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Operating instructions. Speed monitor D / / 2014

CDD4 Duct Carbon Dioxide Transmitter

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Analog Input Installation Manual

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog

PanelView Plus/VersaView CE Terminals and Display Modules

PDI Modular Compact Remote Power Panel

InView Marquee Message Display

Quick Start Guide TS 870 ATS

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

E-Series Site Preparation Guide

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

MAXIMA + Series ROTARY LEVEL CONTROL

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

ABB industrial drives. Safety instructions ACS880 multidrive cabinets and modules

Digital ac/dc (24V) Input Module

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

PowerFlex 755 Transition Section and Splicing Kit for Floormount Drives and CENTERLINE 2100 Motor Control Centers

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Installing and Setting Up the Components

ABB Component Drives ACS55, 0.25 to 3 Hp

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

MDM 011-Z1 Regen Resistor

Transcription:

User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP) Safety Start-Up Embedded Fieldbus Fieldbus Adapter Diagnostics Maintenance Technical Data ACS550 Technical Reference Manual (available in electronic format only) Detailed Product Description Practical Engineering Guides 2015 ABB Inc. All Rights Reserved.

ACS550-PD 3R Irrigation Packaged Drive 3 Table of Contents Table of Contents Safety Use of Warnings and Notes...4 Application...5 Input Disconnect Features and Functions...5 Flow Chart...7 Lifting...8 Installing the Drive...11 Installing the Wiring...16 Typical Control Schematic...19 Application Guides Standard Configuration...21 Optional Configuration - Soft Pipe Fill...22 Technical Data Ratings...23 Input Power Connections...24 Power Connection Terminals...24 Dimensions and Weights...27 Applicable Standards...29 Maintenance Maintenance Intervals...31 Drive Module Fan Replacement...31

4 ACS550-PD 3R Irrigation Packaged Drive Safety WARNING! The ACS550 adjustable speed AC drive with Input Disconnect should ONLY be installed by a qualified electrician. WARNING! Even when the motor is stopped, dangerous voltage is present at the Power Circuit terminals U1, V1, W1 and U2, V2, W2 and, depending on the frame size, UDC+ and UDC-, or BRK+ and BRK-. WARNING! Dangerous voltage is present when input power is connected. After disconnecting the supply, wait at least 5 minutes (to let the intermediate circuit capacitors discharge) before removing the cover. WARNING! Even when power is removed from the input terminals of the ACS550, there may be dangerous voltage (from external sources) on the terminals of the relay outputs. WARNING! When the control terminals of two or more drive units are connected in parallel, the auxiliary voltage for these control connections must be taken from a single source which can either be one of the units or an external supply. WARNING! The ACS550 will start up automatically after an input voltage interruption if the external run command is on. WARNING! When the ACS550 with Input Disconnect is connected to the line power, the Motor Terminals T1, T2, and T3 are live even if the motor is not running. Do not make any connections when the ACS550 with Input Disconnect is connected to the line. Disconnect and lock out power to the drive before servicing the drive. Failure to disconnect power may cause serious injury or death. Note! For more technical information, contact the factory or your local ABB sales representative. Use of Warnings and Notes There are two types of safety instructions throughout this manual: Notes draw attention to a particular condition or fact, or give information on a subject. Warnings caution you about conditions which can result in serious injury or death and/or damage to the equipment. They also tell you how to avoid the danger. The warning symbols are used as follows: Dangerous voltage warning warns of high voltage which can cause physical injury and/or damage to the equipment. General warning warns about conditions, other than those caused by electricity, which can result in physical injury and/or damage to the equipment. Safety

ACS550-PD 3R Irrigation Packaged Drive 5 Study these installation instructions carefully before proceeding. Failure to observe the warnings and instructions may cause a malfunction or personal hazard. WARNING! Before you begin read Safety on page 1. WARNING! When the ACS550 with Input Disconnect is connected to the line power, the Motor Terminals T1, T2, and T3 are live even if the motor is not running. Do not make any connections when the ACS550 with Input Disconnect is connected to the line. Disconnect and lock out power to the drive before servicing the drive. Failure to disconnect power may cause serious injury or death. Application This manual contains supplemental information that is unique to ACS550 input disconnect configurations (PD). Refer to the base manual, AC550-U1 User s Manual, for all other information. Input Disconnect Features and Functions The ACS550 with Input Disconnect is an ACS550 AC adjustable frequency drive packaged with an input disconnect switch and with a door mounted, external operating handle. The operating handle can be padlocked in the OFF position (padlock not supplied). Enclosure are UL Type 3R (NEMA 3R). The following is a typical power diagram. Disconnect Switch or Circuit Breaker Drive with Input Disconnect 3 Phase Input Power 3 ACS550 Drive 3 Motor

6 ACS550-PD 3R Irrigation Packaged Drive The following figures show the front view of the ACS550 Drive with Input Disconnect standard configurations, and identify the major components. UL Type / NEMA 3R Enclosures Operating Handle for Disconnect Switch Note! UL Type 3R enclosures are designed to be mounted on a wall. See section Prepare the UL Type 3R ACS550 for UNISTRUT mounting for more details.

ACS550-PD 3R Irrigation Packaged Drive 7 Flow Chart The installation of Input Disconnect configurations for ACS550 drives follows the outline below. The steps must be carried out in the order shown. At the right of each step are references to the detailed information needed for the correct installation of the unit. Note! References in the middle column below are to the ACS550-U1 User s Manual. References in the third column below are to this manual. Task Refer to the ACS550-U1 User s Manual section Additional Reference in this Manual PREPARE for installation Preparing for Drive Identification on page 9. Suitable Mounting Location on page 10. PREPARE the Mounting Location Prepare the Mounting Location Dimensions and Weights MOUNT the drive Mount the Drive -- INSTALL wiring Wiring Overview and Install the Wiring Installing the Wiring CHECK installation Check -- APPLY power Apply Power -- START-UP Start-Up --

8 ACS550-PD 3R Irrigation Packaged Drive Preparing for (Supplement to ACS550-U1 User s Manual) Lifting the Drive

ACS550-PD 3R Irrigation Packaged Drive 9 Preparing for (Supplement to ACS550-U1 User s Manual) Drive Identification To identify the type of device you are installing, refer to the type code number on the device identification label. Wall mounting base drives label attached on the side surface of the heat sink. Packaged drive label attached to outside surface on the left side of the enclosure. Enclosure with hinged cover/door label on inside surface of the cover/door. Type Code Number Use the following to interpret the type code found on the identification label. AC Drive = 550 Product Series ACS550-PD-125A-4 +C192 Construction PD = Drive with disconnect switch Output current rating (See ratings chart for details) Voltage rating 2 = 230 VAC 4 = 480 VAC Enclosure protection class +C192 = 3R Irrigation Drive Ratings and Frame Size Charts in the Ratings sections of the ACS550-U1 User s Manual and this manual list technical specifications, and identify the drive s frame size. Note! Some instructions in this document vary, depending on the drive s frame size. To read the Ratings table, you need the Output current rating entry from the type code (see above).

10 ACS550-PD 3R Irrigation Packaged Drive Suitable Mounting Location For selecting a suitable mounting location for configurations, refer to: Preparing for installation in the ACS550-U1 User s Manual, and The Technical Data section of this manual for information on dimensions and weights. Installing the Drive (Supplement to ACS550-U1 User s Manual) WARNING! Metal shavings or debris in the enclosure can damage electrical equipment and create a hazardous condition. Where parts, such as conduit plates require cutting or drilling, first remove the part. If that is not practical, cover nearby electrical components to protect them from all shavings or debris. Do not connect or disconnect input or output power wiring, or control wires, when power is applied. Never connect line voltage to drive output Terminals T1, T2, and T3. Do not make any voltage tolerance tests (Hi Pot or Megger) on any part of the unit. Disconnect motor wires before taking any measurements in the motor or motor wires. Make sure that power factor correction capacitors are not connected between the drive and the motor. Prepare the Mounting Location The ACS550 should only be mounted where all of the requirements defined in Preparing for are met. Mount the Drive 1. Use a hoist to move the cabinet into position. Note! If the cabinet location does not provide access to the cabinet sides, be sure to re-mount side panels before positioning cabinet. 2. Install and tighten mounting bolts.

ACS550-PD 3R Irrigation Packaged Drive 11 Installing the Drive - continued Prepare the UL Type 3R ACS550 for UNISTRUT mounting or wall mounting The ACS550 UL Type 3R cabinet frame sizes are designed to be mounted on a solid vertical surface or using UNISTRUT. An optional floor/ground mounting kit is available for purchase.

12 ACS550-PD 3R Irrigation Packaged Drive Installing the Drive - continued Optional Floor/Ground Mounting Kit An optional floor/ground mounting kit is available for purchase.

ACS550-PD 3R Irrigation Packaged Drive 13 Assembly instructions for mounting optional foot kit on 3R irrigation panel Step 1 Prepare mounting surface for enclosure. FLOOR PLAN LAYOUT 5.01 17.74 5.01 6.81 13.62 (6) X 3/8-16 STUD GRADE 5 OR BETTER Step 2 With the enclosure laying on it s back, drill the (10) holes as shown below using a 7/16 inch drill bit. 17.38 16.00 9.00 10 X.44 2.00.62 BOTTOM VIEW FROM LEFT SURFACE OF ENCLOSURE.62 7.22 24.78 31.38

14 ACS550-PD 3R Irrigation Packaged Drive Assembly instructions for mounting optional foot kit on 3R irrigation panel Step 3 Remove the vent plate on the right side of the enclosure to be able to assemble the hardware for the mounting feet. The vent plate can be remounted using two screws for safe keeping. REMOUNTED SCREWS Step 4 Assemble foot kit with mounting hardware. 3/8-16X1 HEX HEAD CAP SCREW 10XN3816A16 (12) REQ'D. 3/8 LOCK WASHER HW1001A38 (24) REQ'D. 3/8 FLAT WASHER HW1000A38 (24) REQ'D. 3/8-16 HEX NUT V6401538 (12) REQ'D.

ACS550-PD 3R Irrigation Packaged Drive 15 Assembly instructions for mounting optional foot kit on 3R irrigation panel Step 5 Using the lifting eyes, lift the enclosure and place onto mounting studs and assemble hardware. 3/8-16 HEX NUT GRADE 5 OR BETTER 3/8-16 LOCK WASHER GRADE 5 OR BETTER 3/8-16 FLAT WASHER GRADE 5 OR BETTER 3/8-16 STUD GRADE 5 OR BETTER

16 ACS550-PD 3R Irrigation Packaged Drive Installing the Wiring (Supplement to ACS550-U1 User s Manual) Wiring Requirements Refer to the Wiring Requirements Section in the ACS550-U1 User s Manual. The requirements apply to all ACS550 drives. In particular: Use separate, metal conduit runs for the following different classes of wiring: Input power wiring. Motor wiring. Control/communications wiring. Properly and individually ground the drive, the motor and cable shields. Wiring Overview Power Connection Standard Drive with Input Disconnect (Wall Mounted) The following figures show the Standard Drive with Input Disconnect (wall mounted) typical layout. (Refer to the ACS550-U1 User s Manual and 3R Irrigation Control Schematic for control connections to the drive.) Install the Line Input Wiring Line Input Connections Standard Drive with Input Disconnect Configurations Connect input power to the terminals of the disconnect switch. Connect the equipment grounding conductor to the ground lug. The figure below shows typical connection points for Standard ACS550 Drive with Input Disconnect configurations. WARNING! Check the motor and motor wiring insulation before connecting the ACS550 to line power. Follow the procedure in the ACS550-U1 User s Manual. Before proceeding with the insulation resistance measurements, check that the ACS550 is disconnected from incoming line power. Failure to disconnect line power could result in death or serious injury. Note! For the remainder of the installation and start-up (motor and control wiring) refer to the ACS550 U1 User s Manual.

ACS550-PD 3R Irrigation Packaged Drive 17 Typical Power Connections for Single and Three Phase

18 ACS550-PD 3R Irrigation Packaged Drive ACS550-PD 15-200 hp *Typical ACS550 3R irrigation panel layout

ACS550-PD 3R Irrigation Packaged Drive 19 Typical Control Schematic

20 ACS550-PD 3R Irrigation Packaged Drive [This page intentionally left blank]

ACS550-PD 3R Irrigation Packaged Drive 21 Application Guides - Hand - Auto Macro Note: Parameter 2108 START INHIBIT must remain in the default setting, 0 (OFF). Connection example: 1 10 kohm 1 X1 1 SCR 2 AI1 3 AGND 4 10V 5 AI2 6 AGND 7 AO1 8 AO2 9 AGND Signal cable shield (screen) External reference 1: 0 10 V (Hand Control) Analog input circuit common Reference voltage 10 V DC External reference 2: 0 20 ma (Auto Control) Analog input circuit common Motor output speed: 0 20 ma Output current: 0 20 ma Analog output circuit common 10 24V 11 GND 12 DCOM 13 DI1 14 DI2 15 DI3 16 DI4 17 DI5 18 DI6 Auxiliary voltage output +24 V DC Auxiliary voltage output common Digital input common for all Start/Stop (Hand): Activation starts the drive Forward/Reverse (Hand): Activation reverses rotation direction EXT1/EXT2 Selection: Activation selects auto control Run enable: Deactivation always stops the drive Forward/Reverse (Auto): Activation reverses rotation direction Start/Stop (Auto): Activation starts the drive 19 RO1C 20 RO1A 21 RO1B 22 RO2C 23 RO2A 24 RO2B 25 RO3C 26 RO3A 27 RO3B Relay output 1, programmable Default operation: Ready =>19 connected to 21 Relay output 2, programmable Default operation: Running =>22 connected to 24 Relay output 3, programmable Default operation: Fault (-1) =>25 connected to 27 (Fault => 25 connected to 26) Note 1. The sensor for AI2 is powered externally. Input signals Output signals Jumper setting Two analog references (AI1, 2) Analog output AO1: Speed J1 Start/stop hand/auto (DI1, 6) Analog output AO2: Current Direction hand/auto (DI2, 5) Relay output 1: Ready AI1: 0 10 V AI2: 0(4) 20 ma Control location selection (DI3) Relay output 2: Running or Run enable (DI4) Relay output 3: Fault (-1) J1 AI1: 0 10 V ON 1 2 ON ON AI2: 0(4) 20 ma Application Guides

22 ACS550-PD 3R Irrigation Packaged Drive Application Guides - Optional Configuration for Soft Pipe Fill -- + Pressure Transducer 4-20 ma = 0-100 ps 1 Auto S/S Contact 1 Application Guides

ACS550-PD Packaged Drive with Disconnect 23 Technical Data Ratings (Supplement to ACS550-U1 User s Manual) Note! The ratings listed below are exceptions to the ratings listed in the ACS550-U1 User s Manual. Technical Data

24 ACS550-PD Packaged Drive with Disconnect Input Power Connections and Power Connection Terminals (Supplement to ACS550-U1 User s Manual) 1-Phase 240V HP ABB Product Code Drive Input Fuse Rating Amps (600V) Bussman Type Incoming Power Connections Minimum Wire Size Maximum Wire Size Tightening Torque (lb/ft) Ground Lugs UL Type 3R/ NEMA 3R Output Connections to Motor Minimum Wire Size Maximum Wire Size Tightening Torque (lb/ft) 15 ACS550-PD-088A-2+C192 100 JJS-110 #8 1/0 55 10 1/0 4 #2 50 in-lbs 20 ACS550-PD-114A-2+C192 150 JJS-150 #4 300MCM 200 10 1/0 4 25 ACS550-PD-143A-2+C192 200 JJS-200 #4 300MCM 200 3/0 350MCM 30 #2/0 275 in-lbs 30 ACS550-PD-178A-2+C192 250 JJS-250 #4 300MCM 200 3/0 350MCM 30 40 ACS550-PD-221A-2+C192 300 JJS-300 #4 300MCM 200 3/0 350MCM 30 350MCM 100 in-lbs 50 ACS550-PD-248A-2+C192 350 JJS-350 #2 600MCM 375 3/0 350MCM 30 NOTE: For information regarding motor terminals. refer to Drives Power Connection Terminals in the ACS550-U1 User Manual.

ACS550-PD Packaged Drive with Disconnect 25 Input Power Connections and Power Connection Terminals (Supplement to ACS550-U1 User s Manual) 3-Phase 240V HP ABB Product Code Drive Input Fuse Rating Amps (600V) Bussman Type Incoming Power Connections Minimum Wire Size Maximum Wire Size Tightening Torque (lb/ft) Ground Lugs UL Type 3R/ NEMA 3R Output Connections to Motor Minimum Wire Size Maximum Wire Size Tightening Torque (lb/ft) 25 ACS550-PD-075A-2+C192 100 JJS-100 #8 1/0 55 10 1/0 4 30 ACS550-PD-088A-2+C192 110 JJS-110 #8 1/0 55 #2 50 in-lbs 10 1/0 4 40 ACS550-PD-114A-2+C192 150 JJS-150 #4 300MCM 200 10 1/0 4 50 ACS550-PD-143A-2+C192 200 JJS-200 #4 300MCM 200 3/0 350MCM 30 #2/0 275 in-lbs 60 ACS550-PD-178A-2+C192 250 JJS-250 #4 300MCM 200 3/0 350MCM 30 75 ACS550-PD-221A-2+C192 300 JJS-300 #4 300MCM 200 3/0 350MCM 30 350MCM 100 in-lbs 100 ACS550-PD-248A-2+C192 350 JJS-350 #2 600MCM 375 3/0 350MCM 30 NOTE: For information regarding motor terminals. refer to Drives Power Connection Terminals in the ACS550-U1 User Manual. Technical Data

26 ACS550-PD Packaged Drive with Disconnect Input Power Connections and Power Connection Terminals (Supplement to ACS550-U1 User s Manual) 3-Phase 480V HP ABB Product Code Drive Input Fuse Rating Amps (600V) Bussman Type Incoming Power Connections Minimum Wire Size Maximum Wire Size Tightening Torque (lb/ft) Ground Lugs UL Type 3R/ NEMA 3R Output Connections to Motor Minimum Wire Size Maximum Wire Size Tightening Torque (lb/ft) 40 ACS550-PD-059A-4+C192 80 JJS-80 #8 1/0 55 10 1/0 4 50 ACS550-PD-072A-4+C192 90 JJS-90 #8 1/0 55 10 1/0 4 60 ACS550-PD-078A-4+C192 100 JJS-100 #8 1/0 55 #2 50 in-lbs 10 1/0 4 75 ACS550-PD-097A-4+C192 125 JJS-125 #4 300MCM 200 10 1/0 4 100 ACS550-PD-125A-4+C192 175 JJS-175 #4 300MCM 200 3/0 350MCM 30 125 ACS550-PD-157A-4+C192 200 JJS-200 #4 300MCM 200 3/0 350MCM 30 #2/0 375 in-lbs 150 ACS550-PD-180A-4+C192 250 JJS-250 #2 600MCM 375 3/0 350MCM 30 200 ACS550-PD-246A-4+C192 350 JJS-350 #2 600MCM 375 350MCM 100 in-lbs 3/0 350MCM 30 NOTE: For information regarding motor terminals. refer to Drives Power Connection Terminals in the ACS550-U1 User Manual. Technical Data

ACS550-PD Packaged Drive with Disconnect 27 Dimensions and Weights (Supplement to ACS550-U1 User s Manual) Dimensions: ACS550-PD UL Type / NEMA 3R 1-Phase 240V HP Weight* (lbs) Height (in) Width (in) Depth (in) 15 310 20 320 25 330 30 340 40 345 50 350 49.00 32.36 22.88 3-Phase 240V 3-Phase 480V HP Weight* (lbs) Height (in) Width (in) Depth (in) HP Weight* (lbs) Height (in) Width (in) Depth (in) 25 305 30 310 40 320 50 330 49.00 32.36 22.88 60 340 75 345 100 350 * Shipping crate adds approximately 170 lbs. 40 300 50 305 60 310 75 320 100 330 125 340 150 345 200 350 49.00 32.36 22.88 Technical Data

28 ACS550-PD Packaged Drive with Disconnect Ambient conditions The following table lists the ACS550 environmental requirements. Ambient environment requirements Altitude site 0 1000 m (0 3 300 ft) 1000 2000 m (3 300 6 600 ft) if P N and I 2N derated 1% every 100 m above 1000 m (300 ft above 3 300 ft) Storage and transportation in the protective package Ambient temperature Min. -20 C (5 F) no frost allowed Max. (fsw = 1 or 4) 40 C (104 F); 50 C (122 F) if P N and I 2N derated to 90% Max. (fsw = 8) 40 C (104 F) if P N and I 2N derated to 80% Max. (fsw = 12) 30 C (86 F) if P N and I 2N derated to 65% (to 50% for 600 V, R4 frame sizes, that is for ACS550- U1-032A-6 ACS550-U1-062A-6) -40 70 C (-40 158 F) Relative humidity 5 95%, no condensation allowed Technical Data

ACS550-PD Packaged Drive with Disconnect 29 Applicable Standards Drive compliance with the following standards is identified by the standards marks on the type code label. Mark UL 508C and C22.2 No. 14 Applicable Standards UL Standard for Safety, Power Conversion Equipment, second edition and CSA Standard for Industrial Control Equipment UL 508A UL Standard for Safety, Industrial Control Panels C22.2 No. 14 CSA Standard for Industrial Control Equipment Compliance is valid with the following provisions: The motor and control cables are chosen as specified in this manual. The installation rules of this manual are followed. Technical Data

30 ACS550-PD Packaged Drive with Disconnect [This page intentionally left blank] Technical Data

ACS550-PD 3R Irrigation Packaged Drive 31 Maintenance Maintenance Intervals If installed in an appropriate environment, the drive requires very little maintenance. This table lists the routine maintenance intervals recommended by ABB. Maintenance Configuration Interval Instruction Check/replace UL Type 3R/NEMA 3R enclosure air filters Check and clean heatsink. Replace drive module fan. Replace enclosure fan(s). UL Type / NEMA 3R enclosures All Check every 3 months. Replace as needed. Depends on the dustiness of the environment (every 6 12 months) See Maintenance in ACS550-U1 User s Manual. All Every six years See Maintenance in ACS550-U1 User s Manual. NEMA 3R enclosures Every three years See Enclosure Fan Replacement UL Type / NEMA 3R. See Maintenance in ACS550-U1 User s Manual. Change capacitor. Replace battery in the Assistant control panel. Frame sizes R5 and R6 Every ten years See Maintenance in ACS550-U1 User s Manual. All Every ten years See Maintenance in ACS550-U1 User s Manual. Drive Module Fan Replacement The drive module fan cools the heatsink. Fan failure can be predicted by the increasing noise from fan bearings and the gradual rise in the heatsink temperature in spite of heatsink cleaning. If the drive is operated in a critical part of a process, fan replacement is recommended once these symptoms start appearing. Replacement fans are available from ABB. Do not use other than ABB specified spare parts. To monitor the running time of the cooling fan, see Group 29: Maintenance Trig in the ACS550-U1 Users s Manual. Maintenance

3AUA0000162200 REV B Effective 02/01/2015 Subject to change without notice. All rights reserved. ABB Inc. Discrete Automation & Motion Drives and Controls 16250 W. Glendale Drive New Berlin, WI 53151 Telephone +1 262 752-0696 +1 800 HELP-365 Internet www.abb.com/drives