SCADAPack 32. Smart RTU

Similar documents
SCADAPack Smart RTU

SCADAPack 350E 357E. Smart Remote Terminal Unit

SCADAPack 330E 334E. Smart RTU

SCADAPack 312E 313E. Smart RTUs for water

SCADAPack 312E 313E 314E

SCADAPack 330E 333E 334E 337E

SCADAPack 350E 357E. Smart Remote Terminal Units. Distributed by Relevant Solutions relevantsolutions.com

SCADAPack 530E 535E. remote Programmable Automation Controller

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

SCADAPack. I/O Expansion & Communication Modules

SCADAPack ES. Smart RTU

SCADAPack FlowStation 110. Pump station controller

SCADAPack ES. Smart RTU

SCADAPack Modbus multivariable transmitter

5403 and 5404 Digital Input Modules

SCADAPack Modbus multivariable transmitter

5502 Differential Analog Input Module

CONTROL MICROSYSTEMS and 5601A Input/Output (I/O) Module. Hardware Manual

SCADAPack E 5405 Digital Input Hardware Manual

SCADAPack E 5505 RTD Input Hardware Manual

5504 Thermocouple Analog Input Module

CONTROL MICROSYSTEMS. SCADAPack 100 Controller. Hardware Manual

CONTROL MICROSYSTEMS Input/Output (I/O) Module. Hardware Manual

5OOO Series. Expansion & Communication Modules. Product Selection Guide. Expansion. Communication CONTROL MICROSYSTEMS

CONTROL MICROSYSTEMS. TeleSAFE Micro16 Controller. Hardware Manual

SCADAPack 32 Controller

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

5604 Input/Output (I/O) Module

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

SCADAPack 100 Controller

CONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual

5607 Input/Output (I/O) Module

Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!

SCADAPack E I/O Module Hardware Manual (337E Only) Version: Date: August 2017

SCADAPack E 5607 I/O Hardware Manual

CONTROL MICROSYSTEMS Potentiometer Analog Input Module. Hardware Manual

Trio Q. Licensed UHF Ethernet and Serial data radio. QR450 Half Duplex

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

5601/5601A Input / Output (I/O) Module

SCADAPack 50. Wireless Remote Data Logger

5910 Ethernet Gateway Module

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

5401 and 5402 Digital I/O Modules

TM221CE40R controller M IO relay Ethernet

iologik E1200H Series

CONTROL MICROSYSTEMS High Speed Counter Input Module. Hardware Manual

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

WiPort-485 Data Sheet

SCADAPack 350E Hardware Manual

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

SCM5B. SLX200 Data Acquisition System. isolynx. Data Acquisition Systems. Visit our website Features

General Specifications

5521 Potentiometer Analog Input Module

CONTROL MICROSYSTEMS Toggle Switch Digital Input Module. Hardware Manual

TM221M16R controller M IO relay

TM221ME32TK controller M IO transistor PNP Ethernet

Features and Benefits. Certifications

MGate 5111 Quick Installation Guide

MGate 4101-MB-PBS Series

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

TM221CE24T controller M IO transistor PNP Ethernet

TM221ME16T controller M IO transistor PNP Ethernet

TM221CE40R controller M IO relay Ethernet

TM221CE24R controller M IO relay Ethernet

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

WiPort Data Sheet. General Description. Hardware & Software Description

Features and Benefits. Certifications

TM221M16TG controller M IO transistor PNP spring

iologik 2500 HSPA/GPRS/WLAN Series

Andover ContinuumTM Infinet II

TM221M32TK controller M IO transistor PNP

NPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview

Ethernet to Digital I/O +RS232 +Switch

S-series Mass Connection Solutions

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

SAGE A powerful distribution automation platform with all the functionality of a gateway. Make the most of your energy SM

MGate 5105-MB-EIP Series

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

5600 Series. 8 and 16-port Serial Device Servers. Features. Internet Readiness for up to 16 Serial Devices

Millenium 3 logic controllers

5905 Ethernet Gateway Module

G303 RIO (REMOTE I/O) AND LOW END RTU

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

TM221ME16RG. Main. Discrete output number. Discrete input current

BACnet. b3810 Series Local Controllers

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

NPort Z2150/Z3150 Series

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

Rugged HMI Technology for Hazardous Areas and Extreme Environments in the Oil & Gas Industry

SCADAPack ES Hardware Manual

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

SCADAPack Input/Output Module Hardware Manual. Version: February 2016

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

Transcription:

SCADAPack 32 Smart RTU

1 Compared to the SCADAPack 300 platform, the SCADAPack 32 is a higher performance Smart RTU built to meet the demands of larger applications including support for up to 10 gas flow runs. This product offers built-in Ethernet, four serial ports, 8 Mb of SDRAM, an integrated power supply, and a wide range of analog and digital I/O options. Featuring industry-standard Modbus and DNP3 serial protocols, and Modbus TCP and UDP-based Ethernet protocols, the SCADAPack 32 can be programmed locally or remotely through a choice of flexible programming languages. As with all SCADAPack products the SCADAPack 32 is based on a multiprocessor architecture with a coprocessor used for handling on-board input/output channels.

Specifications 2 Controller Processor Memory Non Volatile RAM I/O Analog Inputs Analog Outputs Digital Inputs Digital Outputs Digital I/O (5604 I/O board) Communications Serial Port COM1 Serial Ports COM2, COM4 Serial Port COM3 Baud Rates COM1, COM2, COM4 P4A, integrated 56O4 I/O board Hitachi SH-3 32-bit CMOS microcontroller, 120MHz clock, integrated watchdog timer 8 Mb SDRAM, 4 Mb FLASH, 1 Mb CMOS RAM CMOS RAM with lithium battery retains contents for 2 years with no power 8, user selectable 0-10V (15 bit) or 0-20mA (14 bit) 1, 0-32.678V (10 bit) 2 with optional 5305 analog output module, output range 0-20mA 4 on controller board - 3 Digital Input/Counter, 1 Interrupt with optical isolation 1, 30V / 60mA (used as status output) 32 configurable as input or output (1 Amp DC max output / dry contact input) Configurable RS-232 or RS-485, 2 wire half duplex or 4 wire full/half duplex RS-232, DTE, 8 pin modular jack, full or half duplex with RTS/CTS control Implemented Td, Rd, CTS, RTS, DCD, DTR, +5V Located on 5604 I/O module. Same specifications as COM2 and COM4 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 Baud Rate COM3 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 Serial Protocols Ethernet Port Network Protocols Ethernet Port Protocols Modbus RTU, Modbus ASCII, DNP3, DF1, PPP RJ45, 10BaseT IP: ARP, TCP, TFTP, UDP, ICMP Modbus TCP, Modbus RTU in UDP, Modbus ASCII in UDP, DNP in TCP, DNP in UDP Wireless 1 Spread spectrum radio at 900MHz 2 and 2.4GHz 2 General I/O Terminations Dimensions Packaging Environment 6, 8, 9 and 10 pole, removable terminal blocks, 12 to 22 AWG, 15A contacts 8.40 inch (213mm) wide, 6.13 inch (155mm) high, 2.80 inch (72mm) deep Corrosion resistant zinc plated steel with black enamel paint 5% RH to 95% RH, non-condensing, 40 C ( 40 F) to 70 C (158 F) Power Input 11-30 VDC, 4.3W typical (10.8W full I/O capacity in use ) Warranty Certifications North America Safety 3 years on parts and labor Suitable for use in Class I, Division 2, Groups A, B, C and D. Temperature T4 CSA certified to the requirements of: CSA Std. C22.2 No. 213-M1987 - UL Std. No. 1604 - Hazardous (Classified) Locations CSA (ccsaus) certified to the requirements of: CSA C22.2 No. 142-M1987 and UL508. (Process Control Equipment, Industrial Control Equipment) UL (culus) listed: UL508 (Industrial Control Equipment) 1 Available only with optional integrated wireless modules or with stand-alone wireless modules. 2 Not applicable in all countries. Disclaimer: Schneider Electric reserves the right to change product specifications. For more information visit www.schneider-electric.com.

Specifications 3 Controller Processor Memory Non Volatile RAM I/O Analog Inputs Analog Outputs Digital Inputs Digital Outputs Communications Serial Port COM1 P4, integrated 56O1A I/O board Hitachi SH-3 32-bit CMOS microcontroller, 120MHz clock, integrated watchdog timer 8 Mb SDRAM, 4 Mb FLASH, 1 Mb CMOS RAM CMOS RAM with lithium battery retains contents for 2 years with no power 8, user selectable 0-5V (15 bit) or 0-20mA (14 bit) 2 with optional 5303 analog output module, output range 0-20mA 4 on controller board - 3 Digital Input/Counter, 1 Interrupt with optical isolation 16 on 5601A I/O module - 6.5mA typical at 24V and 3.5mA typical at 115V 1 on controller board, 30V, 60mA (used as status output) 12 on 5601A I/O module - Sealed mechanical relay: 0.4A at 125 Vrms, 2A at 30V resistive loads 1.0A at 30V, 0.2A at 125Vrms inductive load with pf=0.4, L/R=7ms 250Vrms, 220V maximum operating voltage Configurable RS-232 or RS-485, 2 wire half duplex or 4 wire full/half duplex Serial Ports COM2, COM4 RS-232, DTE, 8 pin modular jack, full or half duplex with RTS/CTS control. Implemented Td, Rd, CTS, RTS, DCD, DTR, +5V Serial Port COM3 Baud Rates COM1, COM2, COM4 Located on 5601A I/O module. Same specifications as COM2 and COM4 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 Baud Rate COM3 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 Serial Protocols Ethernet Port Network Protocols Ethernet Port Protocols Modbus RTU, Modbus ASCII, DNP3, DF1, PPP 10BaseT, RJ45 IP:ARP, TCP, TFTP, UDP, ICMP Modbus TCP, Modbus RTU in UDP, Modbus ASCII in UDP, DNP in TCP, DNP in UDP Wireless 1 Spread spectrum radio at 900MHz 2 and 2.4 GHz 2 General I/O Terminations Dimensions Packaging Environment Power Input: Warranty Certifications North America Safety 6, 8, 9 and 10 pole, removable terminal blocks, 12 to 22 AWG, 15A contacts 8.40 inch (213mm) wide, 6.13 inch (155mm) high, 2.80 inch (72mm) deep Corrosion resistant zinc plated steel with black enamel paint 5% RH to 95% RH, non-condensing, 40 C ( 40 F) to 70 C (158 F) 11-30 VDC, 3.5W typical all relays off, 6.5W typical all relays on 3 years on parts and labor Suitable for use in Class I, Division 2, Groups A, B, C and D. Temperature T4 CSA certified to the requirements of: CSA Std. C22.2 No. 213-M1987 - UL Std. No. 1604 - Hazardous (Classified) Locations CSA (ccsaus) certified to the requirements of: CSA C22.2 No. 142-M1987 and UL508. (Process Control Equipment, Industrial Control Equipment) UL (culus) listed: UL508 (Industrial Control Equipment) 1 Available only with optional integrated wireless modules or with stand-alone wireless modules. 2 Not applicable in all countries. Disclaimer: Schneider Electric reserves the right to change product specifications. For more information visit www.schneider-electric.com.

Specifications 4 Controller Processor Memory Non Volatile RAM I/O Analog Inputs Analog Outputs Digital Inputs Digital Outputs Communications Serial Port COM1 Serial Ports COM2, COM4 Baud Rates COM1, COM2, COM4 Serial Protocols Ethernet Port Network Protocols Ethernet Port Protocols P4B, integrated 56O6 I/O board Hitachi SH-3 32-bit CMOS microcontroller, 120MHz clock, integrated watchdog timer 8 Mb SDRAM, 4 Mb FLASH, 1 Mb CMOS RAM CMOS RAM with lithium battery retains contents for 2 years with no power 8, single-ended, software selectable 0-5V / 0-10 V or 0-20mA / 4-20mA (15 bit resolution) 2 with optional 5305 analog output module, output range 0-20mA 4 on controller board - 3 Digital Input/Counter, 1 Interrupt with optical isolation, 32 on 5606 I/O module: 0.67 ma typical at 24V on the 12/24V range 0.37 ma typical at 48V on the 48V range 0.35 ma typical at 120V on the 115/125V range 0.35 ma typical at 240V on the 240V range 1 on controller board, 30V, 60mA (used as status output) 16 relay outputs on 5606 I/O module - dry contact or DC solid state: Dry contact rating: 3A, 30VDC or 240VAC (Resistive) DC solid state rating: 3A, 60 VDC Configurable RS-232 or RS-485, 2 wire half duplex or 4 wire full/half duplex RS-232, DTE, 8 pin modular jack, full or half duplex with RTS/CTS control Implemented Td, Rd, CTS, RTS, DCD, DTR, +5V 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 Modbus RTU, Modbus ASCII, DNP3, DF1, PPP RJ45, 10BaseT IP: ARP, TCP, TFTP, UDP, ICMP Modbus TCP, Modbus RTU in UDP, Modbus ASCII in UDP, DNP in TCP, DNP in UDP Wireless 1 Spread spectrum radio at 900MHz 2 and 2.4 GHz 2 General I/O Terminations Dimensions Packaging Environment 5, 6, 8, 9 and 10 pole, removable terminal blocks, 12 to 22 AWG, 15A contacts 8.40 inch (213mm) wide, 6.48 inch (164mm) high, 2.80 inch (72mm) deep Corrosion resistant zinc plated steel with black enamel paint 5% RH to 95% RH, non-condensing, 40 C ( 40 F) to 70 C (158 F) Power Input: 11-30 VDC, 4.3W typical (10.8W full I/O capacity in use ) Warranty Certifications North America Europe 3 years on parts and labor Suitable for use in Class I, Division 2, Groups A, B, C and D. Temperature T4 UL Listed and CSA certified to the following standards: CSA Std. C22.2 No. 213-M1987 - UL Std. No. 1604 - Hazardous (Classified) Locations Model 5606 SSR, 24DI version only ATEX II 3G, Ex na IIC T4 per EN 60079-15, protection type n (Zone 2) Does not include Wireless versions. Model 5606 SSR version only IECEx, Ex na IIC T4 per IEC 60079-15, protection type n (Zone 2) Does not include Wireless versions. 1 Available only with optional integrated wireless modules or with stand-alone wireless modules. 2 Not applicable in all countries. Disclaimer: Schneider Electric reserves the right to change product specifications. For more information visit www.schneider-electric.com.

Model 5 TBUP4-102-02-0-0 represents a sample code for a P4 with DNP, 0-5V inputs, 12-24V outputs Model Select: Controller TBUP4 SCADAPack 32, 32 Bit controller with Integrated Ethernet Port Select: Lower I/O Module 5601A lower I/O module, includes 16 Digital Inputs, 12 Digital Outputs and 8 Analog Inputs (see options below) A 5604 lower I/O module, includes 32 configurable Digital I/O and 8 selectable Analog Inputs (0-10v or 0-20mA) B 5606 lower I/O module, includes 32 D/I, 16 Dry Contact D/O and 8 software configurable A/I C 5606-A lower I/O module, includes 32 D/I, 16 Solid State Relay D/O and 8 software configurable A/I C No lower I/O module (provides controller module only) Select: Communications Serial Ports 1 TBUP4/P4A/P4N: 3 RS232, 1 RS232/485, 1 Ethernet TBUP4B/P4C: 2 RS232, 1 RS232/485, 1 Ethernet Integrated FreeWave & MDS Radios A 900Mhz FreeWave Spread Spectrum Radio Consult CMI for availability in your market area 3 900MHz MDS Spread Spectrum Radio Consult CMI for availability in your market area Trio Radios - 900MHz (requires one RS232 port) B 900MHz Trio Spread Spectrum Radio with encryption, 902-928MHz (FCC / IC) C 900MHz Trio Spread Spectrum Radio with encryption, 915-928MHz (AUS) D 900MHz Trio Spread Spectrum Radio, 915-928MHz (BRAZIL) E 900MHz Trio Spread Spectrum Radio, 921-928MHz (NZ) Trio Radios - 2.4GHz (requires one RS232 port) J 2.4GHz Trio Spread Spectrum Radio, ETSI/100mW, ATEX (EUROPE) K 2.4GHz Trio Spread Spectrum Radio with Encryption, 500mW (CANADA, USA & AUSTRALIA) L 2.4GHz Trio Spread Spectrum Radio, 500mW (OUTSIDE OF EUROPE, CANADA, USA & AUSTRALIA) Select: Gas Flow Run-time Option 0 None Flow Computer Runs G 2 Run Gas Flow F 4 Run Gas Flow T 10 Run Gas Flow Flow Computer Runs - Gas Transmission Version (Requires Realflo 6.72+) V 2 Run Gas Flow W 4 Run Gas Flow Select: Protocol Option/Programming Environment 2 Modbus and DNP 3.0 (Level 2) protocol with Telepace Ladder Logic and C Language firmware loaded - IEC enabled 5 Modbus and DNP 3.0 (Level 2) protocol with IEC 61131-3 and C Language firmware loaded - Telepace enabled Select: Analog Inputs 01 0-20mA, single ended (On TBUP4 & TBUP4A, Default on TBUP4B which is software configurable to 0-5v or 0-10v) 02 0-5 volt, single ended (TBUP4 Only) 03 0-10 volt, single ended (TBUP4A Only) Select: Digital Inputs/Outputs 0 24 volt D/I TBUP4 & TBUP4B: Dry Contact D/O TBUP4C: SS Relay D/O TBUP4A: Config I/O TBUP4N: No I/O 1 120 volt D/I TBUP4 & TBUP4B: Dry Contact D/O TBUP4C: Solid State Relay D/O (Not for TBUP4A or TBUP4N) Select: Analog Outputs 0 None (required for TBUP4N) 1 2 channel Analog Output option, 0-20 ma Telemetry & Remote SCADA Solutions www.schneider-electric.com Document Number TBULM08002-85 2011 Schneider Electric. All rights reserved - August 2011