ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

Similar documents
Supplementary Components WirelessHART products

Using the WirelessHART transmitter TTF300-W as repeater to extend the availability of a WirelessHART network

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Supplementary Components WirelessHART products

Technical Data. General specifications. Rated operating distance s n 3 mm

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

WirelessHART Adapter SWA70

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

String monitoring with CMS - Circuit monitoring system Increased productivity and improved maintenance of PV systems

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

General Specifications

ABB MEASUREMENT & ANALYTICS DATA SHEET. DAT200 Asset Vision Basic and DTM Device Typ Manager

Series 3730 Type Electropneumatic Positioner

General Specifications

ABB MEASUREMENT & ANALYTICS DATA SHEET. JDF200 Field Indicator

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Safety instructions Overvoltage protection B81-35

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. Industrial tablet PC Field device management tools

Technical Information Promonitor NRF560

MANUAL Surge Protectors

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Accessories for pluggable interface relays CR-P Sockets

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

TEPI11 P/I signal converter

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

DTM Distributed Transmitter Monitor

General Specifications

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

SMARTLINE RM76 Supplementary instructions

Siemens AG Network transitions. 8/2 Transition from Industrial Ethernet to WirelessHART 8/2 IE/WSN-PA LINK

ABB MEASUREMENT & ANALYTICS DATA SHEET. Industrial tablet PC Field device management tools

THE PEPPERL+FUCHS GROUP. WirelessHART Products Overview Karsten Fischer - Global Account Manager Invensys

Redundancy unit CP-A RU

Installation & Operation Manual

General Specifications

Series 3730 Type Electropneumatic Positioner

The iwap107 supports 100/1000Base-T, offering a significant increase in speed over the older fast Ethernet standard.

Switching relay CT-IRE with 1 c/o (SPDT) contact

CPU module for zone 2 Series 9442/35

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

IECEx Certificate of Conformity

ABB i-bus KNX HCC/S Heating/cooling circuit controller

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

MGate 5105-MB-EIP Quick Installation Guide

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

S-series IS Electronic Marshalling

Technical Information WirelessHART Fieldgate SWG70

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

LME620-AI/-AN (Contrac) Electrical Linear Actuator

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

C160 Wall-/Pipe Mounted Universal Process Indicator

Bus Connection Unit 560BCU04

INDI BOY DSP Load limitation electronics

Crane-Boy / Crane-BoyP Load limitation electronics

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Inductive sensor BI1.5-EG08-Y1-H1341

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Inductive sensor NI3-EG08K-Y1-H1341

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Inductive sensor BI1.5-EG08-Y1-H1341

SITOP in the SIMATIC Design

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N

DeltaV Bulk Power Supplies

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Installation & Operation Manual

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

MGate MB3170/MB3270 Quick Installation Guide

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-498-2TX

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

FICHA TÉCNICA DE PRODUTO

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Refer to attachment for more details. Andreas Meyer

Dräger Polytron 8200 Stationary gas detector (CatEx)

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Operating Instructions

FLEX Ex Spring Clamp Terminal Base

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

5 Fieldbus Technology

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Features and Benefits. Certifications

ABB i-bus KNX BCI/S Boiler/Chiller Interface

S900 Remote I/O System Intrinsic safety in the field ABB

Serial/Ethernet Converter

Series 95000, 2/2 Direct solenoid actuated poppet valve

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Transcription:

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET WirelessHART components Gateway and accessories

2 Measurement made easy The ABB offering on WirelessHART accessories connect wireless sensors to the automation network and extend the range of the wireless communication easily. Proven industrial quality Key components for your wireless network Installable with standard tools Fast and easy commissioning Allows one-stop orders

Change from one to two columns Specification Power supply for gateway WirelessHART gateway Figure 2: Power supply Power supply for gateway Dimensions (W x H x D) 63.2 x 123.6 x 123.6 mm (2.49 x 4.87 x 4.87 in.) Features Figure 1: WirelessHART gateway Low power dissipation and low heating Free convection cooling Ambient temperature range during (no forced cooling with ventilators) MODBUS WirelessHART gateway Features Graphical network analysis operation 35 to 70 C (-31 to 158 F) Simple and automatic configuration options HART and MODBUS protocol via both Configuration via DTM or DD and webserver Input 20 to 60 C ( 4 to 140 F) External bus Input Interface 1: Protocols: HART UDP, MODBUS TCP Interface 2: RS485 Protocols: HART, MODBUS RTU Power supply 20 to 30 V DC SELV/PELV, <5 W Redundant power supply connections Cable gland Steel Explosion protection ATEX FM II 3G Ex na nc IIC T4 Gc NI Class I, Div. 2, GPS A-D NI Class II, Class III, Div. 2, GPS E-G IEXEc Ex na IIC T4 Gc Ex nac T4 IP rating IP 66 / IP 67 Installation Panel mounting Scope of delivery WirelessHART gateway Antenna 3KDE998517L0001 Integrated input fuse 115 / 230 V AC 210 to 375 V DC), auto select Output 24 V DC, constant controlled output voltage output current 5 A Ethernet, 10 BASE-T/100 BASE-TX, full galvanic isolation Open-circuit, overload and short-circuit (90 to 132 V AC, 180 to 264 V DC), Omnidirectional dipole antenna, removable WirelessHART stable interfaces Temperature range Typical efficiency of 86 % output power 120 W Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool 3KDE998504L0001 3

4... Specification WirelessHART adapter WirelessHART adapter Explosion protection Zone 1, 21 Ex d ATEX II 2G Ex db IIC T6 T5 Gb II 2D Ex tb IIIC T95 C Db FM XP Class I, II, III, Division 1, Groups A-G Class I, Zone 1, AEx db IIC T6...T5 Gb Zone 21, AEx tb IIIC T95 C Db CSA XP Class I, II, III, Division 1, Groups A-G Ex db IIC T6...T5 Gb Ex tb IIIC T95 C Db IECEX Ex db IIC T6...T5 Gb Ex tb IIIC T95 C Db Zone 0, 20 Ex i Figure 3: WirelessHART adapter ATEX WirelessHART adapter FM II 1G Ex ia IIC T6...T5 Ga II 1D Ex ia IIIC T95 C Da Features Cast aluminum housing, Class I, Zone 0, AEx ia IIC T6...T5 Ga Loop powered, Zone 20, AEx ia IIIC T95 C Da Direct mounting on HART or 4 to 20 ma field Input IS Class I, II, III, Division 1, Groups A-G CSA IS Class I, II, III, Division 1, Groups A-G device, Ex ia IIC T6...T5 Ga Encapsulated antenna, Ex ia IIIC T95 C Da Up to 8 field devices in multidrop associated apparatus [Ex ia] Connection: IECEX Ex ia IIC T6...T5 Ga 5 wires, 600 mm long, exiting from male Ex ia IIIC T95 C Da ½ in. NPT thread 1 external grounding point HART communication: Protocol HART 7.1, backward compatible Number of devices up to 8 HART field devices (depending on installation) Output Omnidirectional integral antenna, WirelessHART communication Power supply Rated voltage Un 7 to 32 V DC Rated current In < 1 ma, max. 25 ma Voltage drop 1 to 2.5 V DC adjustable in steps of 0.5 V Cable gland Male ½ in. NPT thread IP rating IP 67 Temperature rating 40 to 85 C ( 40 to 185 F) WirelessHART adapter non-ex 3KDE998536L0011 WirelessHART adapter Ex d 3KDE998536L0010 WirelessHART adapter Ex i 3KDE998536L0009

5 Accessories Coaxial cable Antenna for gateway G11951 Figure 4: Antenna G11952 Figure 6: Coaxial cable Antenna Type Replacement antenna for WirelessHART Coaxial cable 1 m or 2 m gateway with 2.0 dbi antenna gain Type Connection TNC plug 3KDE998517L0002 Coaxial cable, double shielded Connection N plug to N plug Length 1 m: 3KDE998544L0001 Length 2 m: 3KDE998544L0002 Surge protection for gateway Length 5 m: 3KDE998544L0006 Connecting adapters 1 2 3 G11953 Figure 5: Surge protection G11954 Surge protection Type λ/4 surge protection according IEC 61643-21 Connection N socket to N socket 3KDE998535L0001 Figure 7: Adapters Pos. Type 1 N socket to TNC socket 2 N socket to N socket 3KDE998536L0007 3 TNC plug to N socket 3KDE998536L0005 3KDE998536L0006 Change from two to one column Connection example Adapter 1 Standard antenna 2 dbi Coaxial cable Adapter 2 or Adapter 3 Coaxial cable WirelessHART surge protector gateway WHA-GW-* TNCM TNCF NF NM NM NF NF NM NM NF TNCM TNCF G11955-01 Figure 8: Connection diagram (example)

26 Trademarks WIRELESSHART WIRELESSHART COMPONENTS COMPONENTS GATEWAY GATEWAY AND AND ACCESSORIES ACCESSORIES DS/WIRELESSHART/COMPONENTS-EN DS/WIRELESSHART/COMPONENTS-ENREV. REV.BB Measurement made easy The ABB offering on WirelessHART accessories connect wireless sensors to the automation network and extend the range of the wireless communication easily. WirelessHART is a registered trademark of FieldComm Group, Austin, Texas, USA Modbus is a registered trademark of the Modbus Organization Proven industrial quality Key components for your wireless network Installable with standard tools Fast and easy commissioning Allows one-stop orders

7

To find your local ABB contact visit: abb.com/contacts We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. Copyright 2018 ABB. All rights reserved. 3KXN674901R1001 DS/WirelessHART/COMPONENTS-EN Rev. B 05.2018 For more information visit: abb.com/wirelessmeasurement