Digital Torque Meter. ADT-C Series OPERATION MANUAL

Similar documents
SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

FG-3000R Digital Force Gauge Operation Manual

FG-3000 Digital Force Gauge Operation Manual

Instruction Manual. Digital Force Gage. MODEL-SX series

FG-7000L Digital Force Gauge Operation Manual

FG-7000 Digital Force Gauge Operation Manual

TTC Series Torque Tool Tester Operation Manual

DIGITAL TORQUE METER MODEL TME2

Digital Torque Gauge. User s Manual

Digital Torque Screwdriver Model STC2-G

Standard Model Digital Force Gauge ZTS series

Digital Torque Screwdriver

High Functionality Model Digital Force Gauge ZTA series

Digital Torque Tester/Wrench

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

TORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional

Digital Torque Tester

NOTES TABLE OF CONTENTS

-Direct.com FG-3000 Digital Force Gauge Operation Manual

DIGITAL ANGLE WRENCH CTA2-G MODEL INSTRUCTION MANUAL

Digital Torque Wrenches

DTW 400/DTW Digital Torque Tester/Screwdriver User s Guide

E101 - Strain Gauge Transducer Display Module. Contents

Portable Conductivity Meter M1410. User Manual 1.002

Separate sensor model

4-Channel Thermometer

Please refer to Page 3.

Standard Model Digital Force Gauge ZTS series

IMADA CO.,LTD. Digital force gauge ZT series separate model High functionality/high performance Digital Force Gauge ZT Series Separate Sensor Model

ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL

NIDEC-SHIMPO INSTRUMENTS

Torque Meter. Instruction Manual

Digital Force Gauge INSTRUCTION MANUAL. Model: DS2

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

User Guide Automatic Transfer Switch (ATS)

Instruction Manual FH

SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS SAFETY INFORMATION... 2 WARNINGS... 28

NIDEC-SHIMPO INSTRUMENTS

Instruction Manual FH EXT

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

Instruction Manual FH EXT

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide

Hand held use More precise force measurement Force-displacement measurement

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this


Instruction Manual FH

RH/Temperature SD Card Datalogger. Instruction Manual

Model DT-315P DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Series FGE-XY Force Gauges Operation Manual

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

Series CTA CAP TORQUE TESTERS. User s Guide

FOR VISUAL CARD READER / WRITER. Installation Guide & Specifications

DIGITAL TORQUE WRENCH TESTER MODEL DOTE3

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

Installation and operation manual ReciFlow Gas

NIR Moisture Analyzer KB-30

Type K/J Thermometers

Pass Guard System. Brushless Screwdriver with Built-in Torque Sensor PG Series. Control Unit PG-01. User s Manual. HIOS Inc.

Operation Manual DT-326. LED Stroboscope

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

NIDEC-SHIMPO INSTRUMENTS

4-Channel Datalogging Thermometer

Trade Approved Version NMI: S520

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

7561-PSD Manual Portable Battery Powered Indicator

LCM SYSTEMS. TR150 Portable Battery Powered Indicator. Instruction Manual. Software version V2.XX

SHIMPO INSTRUMENTS. ST-320BL LED Stroboscope Array Operation Manual

Druck DPI 620 advanced modular calibrator

Electrostatic Potential Sensor

User s Guide. Series CT CLOSURE TORQUE TESTER. User s Guide

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

DFS Series User s Manual (5N-1000N Capacity)

Functions Output Overload Warning Weight Dimensions Included

TORQUE METER Model : TQ-8800

Instruction Manual FH

Digital force gauge DSV/DST series

Series STA DIGITAL TORQUE TOOL TESTERS. User s Guide

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

Instantaneous/Accumulated Flowsensor NW, OF-W Handling Manual compliance

CONTENTS Introduction 4 DTR overview 4 probes 5 functions 5 display 5 DTR operation 6 switching the DTR on or off 6 changing label 6 displaying

DPM Digital DC Power Meter with Data logging capability. User Manual

FGV-HXY Digital Force Gauge Operation Manual

IMADA CO.,LTD. Digital force gauge ZT series separate model High functionality/high performance Digital Force Gauge ZT Series Separate Sensor Model

OPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

CW Series Check Weighing Scales. Instruction Manual

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

Series ST. User s Guide DIGITAL TORQUE TOOL TESTERS. .com. Series ST Torque Tool Testers. User s Guide

Light Meter with Bar Graph

I. PANEL DESCRIPTION... 1

TNP Digital Torque Meter Operation Manual

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments

TR150 Digital Readout Unit SL755. Impact Test Equipment Ltd & User Guide. User Guide

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

Shore D Hardness Tester TH210. Instruction Manual. TIME GROUP INC. Beijing Time High Technology Ltd

Operating Instruction PPC-04 /2

Transcription:

ADT-C Series Digital Torque Meter ADT-C Series OPERATION MANUAL CO., LTD

Digital Torque Meter It is the torque-measuring instrument of the electronic formula which can measure torque power. It corresponds to a large area from the field of a quality control to the research and development. Our Digital Torque Meters are used well to check intensity or movement of some parts in automobile industry, electric industry and etc. Features Our Digital Torque Meter has original design. Sampling Speed 1ms The digital range of display is max. 9999. Digimatic, Analog, RS-232C and Comparator out-put are attached as standard accessory. Example Use Peak Holding Measurement and Tracking Measurement Peak Holding Memory is 50 Measurements Value. The limit of HI(HIGH) and LO(LOW) can be made by comparator out-put. Selectable 3 units (N m Kgf cm in lbf) Battery Volume can be checked on display. Power auto-off function. When there is no key 5 minutes,a power supply is turned off automatically.. -1-

Notes Do not overload The limit of overload capacity is 120% of full scale. When the load is reached to 110% of Full Scale, OVER LOAD is indicated on display. Keep it within 100% of Full Scale. This is the cause for the breakdown of load sensor. In case of over load setting 1 ~ 100 %, OVER LOAD will be indicated on display when the load is reached over your setting value. (Regarding over load setting, please see page No.9.) Do not use other adapter Should other adapter be used, there are possibility to breakdown or may lead to a fire. Also, do not charge or operate unit in other voltage. Do not impact or damage unit This is the cause for the breakdown of load sensor or other troubles. Do not store and operate in the following conditions Wet area Where dew condensation Dusty area Where oil or chemicals Do not disassemble, trouble-shoot and remodel Should you perform any of these, that may cause malfunction of the unit. -2-

Specifications Standard Specifications Measuring Unit : Selectable 3 units N m(n cm)/kgf cm/in lbf Accuracy : ±0.5% of F/S Measurement : Peak Holding / Tracking Peak Holding : Digital Peak Holding Peak Holding Memory : 50 Measurement Values Sampling Speed : 1ms Display : 4 digits LCD Over Load Capacity : 120% Auto Power Off Term : 5 minutes Attachment : Please refer page No.5 and 6. Net Weight : About 3.2 kg Guarantee : 1 year Power Supply : Rechargeable Ni-MH Battery (Charging Time : About 4 hours) Out-Put : 1Digimatic out-put 2RS-232C out-put 3Reset signal in-put 4Comparator out-put 5Analogue out-put (±1V) *Regarding the details for out-put, please refer page No.13. -3-

Model & Indication Range MODEL Measuring Range Min. Indication ADT-C1 ADT-C2 ADT-C5 ADT-C10 ADT-C20 ADT-C50 ADT-C100 ADT-C200 1.000-9.999N cm/0.100-1.000kgf cm/0.100-1.000in lbf 0.001N cm/0.001kgf cm/0.001in lbf 2.00-20.00N cm/0.200-2.000kgf cm/0.200-2.000in lbf 0.01N cm/0.001kgf cm/0.001in lbf 5.00-50.00N cm/0.500-5.000kgf cm/0.500-5.000in lbf 0.01N cm/0.001kgf cm/ 0.001in lbf 0.100-0.999N m/1.000-9.999kgf cm/1.000-9.999in lbf 0.001N m/0.001kgf cm/0.001in lbf 0.200-2.000N m/2.00-20.00kgf cm/2.00-20.00in lbf 0.001N m/0.01kgf cm/0.01in lbf 0.500-5.000N m/5.00-50.00kgf cm/5.00-50.00in lbf 0.001N m/0.01kgf cm/0.01in lbf 1.000-9.999N m/10.00-99.99kgf cm/10.00-99.99in lbf 0.001N m/0.01kgf cm/0.01in lbf 2.00-20.00N m/20.0-200.0kgf cm/20.0-200.0in lbf 0.01N m/0.1kgf cm/0.1in lbf 1 In case of 100% to 110% of full scale of measuring range, the display indicate the measuring value. However this measuring value can not be used for your measurement. Incase of 110% over, OVER LOAD is indicated on display. (This is in case of over load setting 0 ) In case of over load setting 1 ~ 100 %, OVER LOAD will be indicated on display when the load is reached over your setting value. (Regarding over load setting, please see page No.9.) -4-

TSS-5: Screw is a replacement formula. Screw of the side is loosened. *Reserve:Two screws each are attached. ADT-C ADT-C10 Standard Attachments for each model Model No. Standard Accessories (each 1 pce.) ADT-C1 TC-2 TSS-5 ADT-C2 TC-2 TSS-5 ADT-C5 TC-2 TSS-5 ADT-C10 TC-3 TSS-10 ADT-C20 TC-3 TSS-20 ADT-C50 TC-6 TSS-30 ADT-C100 TC-4 TSS-30 ADT-C200 TC-4 TSS-30 Attachments ADT-C ADT-C1 2 5 TSS-5 (M4Screw/#2+With Spring) 0.1~0.5N m TC-2 (M3Screw/#2) TSS-10 (M4Screw/#2+With Spring) 0.2~1N m TC-3 (M4Screw/#2) TSS-10 10: Screw is a replacement formula. Screw of the side is loosened. *Reserve:Two screws each are attached. -5-

ADT-C ADT-C20 TSS-20 (M5Screw/#2+With Spring) 0.5~2N m TC-3 (M4Screw/#2) TSS-20 20: Screw is a replacement formula. Screw of the side is loosened. *Reserve:Two screws each are attached. -5-2-

ADT-C ADT-C50 TSS-30 30: Screw is a replacement formula. Screw of the side is loosened. *Reserve:Two screws each are attached. TSS-30 (M6Screw/#3+With Spring) 0.5~3N m TC-6 (M5Screw/#2) ADT-C ADT-C100 200 TSS-30 (M6Screw/#3+With Spring) 0.5~3N m TC-4 (M6Screw/#3) TSS-30 30: Screw is a replacement formula. Screw of the side is loosened. *Reserve:Two screws each are attached. -6-

Description of Parts Name NO.12345 GAIN CON. DC LCD Display Model and Max.Capacity Sticker Function Switch Data Output Switch Power Switch Reset Switch Power Connector External Input/Output Gain Ajust Dial MADE IN JAPAN A DT-C2 0 MAX.Capacity 2.000 N m 20.00 Kgf cm 20.00 in lb P D F RESET DIGITAL TORQUE METER 注意事項 表示の最大許容値以上を絶対に加えないで下さい 連続での衝撃測定には使用しないで下さい 充電時間は絶対に 4 時間以内にして下さい Precautions Load must not exceed max capacity. Avoid successiveshock tests. Do not recharge for more than 4hours. MADE IN JAPAN Serial Number Sticker Protection Glass Measuring Socket -7-

Explanation of each parts (1) EXTERNAL INPUTI / OUTPUT (CON.) It is possible to do the various outside output and display reset from outside. For details, see the explanation of the output connector page No.9. POWER CONNECTOR (DC) Insertion connector of AC adapter for the charging. The standard recharging time is about 4 hours after making a power off. The charging condition can be confirmed by display when making a power on. Also, it can be used inserting AC adapter. However, it becomes the cause which hastens the degradation of the charging battery. Recommend to use without using AC adapter as much as possible. GAIN ADJUST DIAL ONLY MANUFACTURE SIDE (NEVER CHANGE THIS DIAL) It is used when the calibration at the manufacture. LCD DISPLAY Using graphic LCD (liquid crystal), it is possible to show a feature character, setting character, numbers and charging scale in the display. PROTECTION GLASS Digital display is covered by protection glass. MODEL AND MAX. CAPACITY STICKER Model number and maximum display value of 3 units and indicated. POWER SWITCH (P) On/Off button of the power. The buzzer sounds in case of start the operation. DATA OUTPUT SWITCH (D) Output button for the digimatic signal and RS-232C signal of the data. It outputs a digital signal firstly and it outputs a RS-232C signal. (Caution) It outputs the digital signal when using a function feature. Also, in case of function feature (FU), it can be changed Peak Hold and Tracking, the reading of memory data and various setting of value. -8-

Explanation ation of each part(2) FUNCTION SWITCH (F) This button is for setting up each function. To change function mode, keep to push about 6 seconds. ( FU is indicated in LCD Dispay), can be set up each function. RESET SWITCH This button is for resetting data indication of peak-hold and tracking. Besides when the mode is function (FU), you can reset all of the memory data (but cannot reset the data one-by-one), and can alter the figure (then the figure is underlined) by this button. SERIAL NUMBER STICKER Serial number is mentioned on this sticker. MEASURING SOCKET Attachment should be set on this measuring socket. -9-

Explanation of a button setting function (1) Various functional set up in button operation. Set up the function 1Change Peak Hold (PEAK) and Tracking (TRUCK) 2Check Memory (MO) Data and Elimination of all memory data 3Set up Comparator Function (HI) 4Set up Comparator Function (LO) 5Change Measuring Unit (UN) 6Set up Over Load (OV) 7Set up Power Auto Off(AP) 8Set up Number of Digits on display / NP setting 9Reverse Digital Display Power switch is turned ON while pressed the P-button. (Becomes MEASUREMENT MODE) (When there is no key 2-3minutes,a 2 power supply is turned off automatically) Keep to push F button about 6 seconds, indicate by FU (function). (Becomes SETTING MODE) Preparations the various setting were completed. The programming procedure after FU display 1Change Peak Hold (PEAK) and Tracking (TRUCK) Change the Peak hold (PEAK) and change the tracking (TRUCK) when pressed the D button. (Initial setting : TRACK) 2Check Memory (MO) Data and Elimination of all memory data MO in the upper right side of the display. Can be confirmed the memory date. The memory data is advanced when press the D button. (from M01 up to M50) Elimination of all memory data should press the RESET button. (Each data is not eliminable) The display indicate MO 0 when data is eliminated. (Initial setting : 0) 3Set up Comparator Function (HI) Set up the upper limit of comparator function Figure rising by D-button and Digit rising by RESET-button. When not using this function, setting to the 0. (Initial setting : 0) -10-

Explanation of a button setting function (2) 4Set up Comparator Function (LO) Set up the low limit of comparator function. Figure rising by D-button and Digit rising by RESET button. When not using this function, setting to the 0. (Initial setting : 0) 5Change Measuring Unit (UN) To push D button, display change from N Kgf lbf N (Initial setting : N) 6Set up Overload (OV) Count up by D button. Figure up by RESET button. Setting value is %. It cannot set under 0. When not using this function, setting to the 0. (Initial setting : 0) In case of setting 0, OVER LOAD will be indicated on display when the load is reached from 100% to 110% of full scale. 7Set up Power Auto Off(AP) To push D button, Set up the Power auto off 1 release 0 (Initial setting : 1) 8Set up Number of Digits on display / NP setting (NP) Push "D" button. If you need 3 digits on display, please set"1". If you need 4 digits, please set " 2 ". It is possible to change number of digits by this function. 9Reverse Digital Display The Value becomes flashing & dark. To push D button, the direction of display indication is reversed in upside down position. TO 1 Change Peak Hold (PEAK) and Tracking (TRUCK) Keep to push F button about 6 seconds, the gauge is now ready to measure. -11-

Digital indication for function mode It will become FU display if F Switch is pushed for about 6 seconds. (Measurement functional stop state) Next,if F Switch is pushed, a setup of each function can be performed. PEAK FU N m PEAK FU MO 0 PEAK N m FU HI N m PEAK FU LO PEAK FU UN PEAK FU OV N m N m N m PEAK FU AP PEAK FU NP PEAK FU N m N m N m *Display reversed with D Switch PEAK FU N m Digital indication for warning messages Over Load Indication Low Battery Indication OVER LOAD BATT -12-

External Input / Output *Connector of HIROSE brand HR25-9TR-16S is used.(16 pins) Please prepare a plug HR25-9TP-16P. Name of signal for each connector pin is as follows. 1.Analog output ±1V 2.Analog GND 3.Signal input for External reset Indication reset 4.Input COM 5.Comparator HI Open Collector Output (50V / 100mA) 6.Comparator GO 7.Comparator LO 8. 9.Output COM 10.RS-232C Rx Please refer the following RS-232C Format 11.RS-232C Tx 12.Digimatic output (DATA) 13.Digimatic output (CK) 14.Digimatic output (RD) Connector Form 15.Digimatic output (REQ) 16. GND 1 3 4 8 9 13 14 16 RS-232C Format 1.Interfacing (Bit) Spec. Start Bit : 1 bit Date Length : 8 bit Stop Bit : 1 bit Parity : None Baud Rate : 9600 BPS -13-

CO., LTD. 600-5 HIGASHI TAKADACHO, TOYOHASHI AICHI 441-8115 JAPAN. TEL : (0532)-41 41-5357 FAX : (0532)-41 41-4826 4826 URL:http http://www.attonic.co.jp E-mail mail:info info@attonic.co.jp