CAN GATEWAY MESSAGING REFERENCE MANUAL

Similar documents
STYLE 6000 SERIES CAN MESSAGING REFERENCE MANUAL OPERATING INSTRUCTIONS CAN MESSAGING

STYLE 3600 SWITCH INTERFACE TRANSMITTER INSTALLATION AND OPERATING INSTRUCTIONS

STYLE 6046 AKRO VIEW DIAGNOSTIC SOFTWARE INSTALLATION AND OPERATIONS MANUAL

Style 6032 UNIVERSAL II CONTROL INSTALLATION, OPERATION & MAINTENANCE MANUAL

SGH Cable Actuated Sensor Industrial CANOpen

Profibus DP Expansion Board

NOVOtechnik SIEDLE GRUPPE

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

OPERATING INSTRUCTIONS. CANopen - Protocol with Device Profile in accordance with CiA DSP 408

BMS CAN Manual. V2.0, September 3, 2018 Visit to download the latest revision of this manual Copyright 2018 Roboteq, Inc

Troubleshooting Tips & Procedures. Model 8800 series. GeoNet Wireless

NOVOtechnik. Content. TIM CANopen Gebrauchsanleitung TIM CANopen user manual SIEDLE GRUPPE

CANopen MANUAL. TMCM axis stepper controller/driver board 2.8A RMS / 24V DC Encoder interface

DeviceNet Expansion Board

Trimble S6 and SPS700 Total Station Firmware

Two Module Development Kit Installation and User Instructions For Model No. ED-GV15/30

CANopen. Network configuration. Operating instructions Software. Integration of Bürkert devices in CANopen networks

TanTime Systtem Timer Operation Instructions

CANopen IO X4 Fact sheet

Release Information. Revision History. Version: build 018 Release Date: 23 rd November 2011

Digi-Pas Innovation & Technology Driven

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

SmartStack SAE J1939 Communication Module

Suretrol Manufacturing Inc. MA052X-2. Kiln Controller User's Manual

EDGE Motor. Evaluation Kit Application Guide. EDGE REV:A August 29, 2012

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

Tritex II. CANopen - Option

Compact IO Modules (M8) for CANopen

DD-2100 Owner s Manual 2X10 DVI Distribution Amplifier

SR1H Cable Actuated Sensor Industrial CANOpen Output Signal

GUYMON GONIOMETER USER INSTRUCTIONS

CANopen. stepim. Reference Manual. Manual Revision: 1.3 Firmware Version:

Digi-Pas Innovation & Technology Driven

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Wasp Embedded Controller

User manual. magnetic absolute positioning drive with AG03

User Manual Connection to CAN

Installation and Operation Guide

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

LXM23A CANopen Fieldbus protocol for servo drive Fieldbus manual V2.00,

EXM Configuration Tool EXM System Configuration Instructions

CiA Draft Standard Proposal 410. CANopen. Device Profile for Inclinometer. This a draft standard proposal and not suitable to be implemented

CANopen Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

Analog Interface Unit Operation Manual

AT21CS Series Reset and Discovery. Introduction. Serial EEPROM APPLICATION NOTE

PMBus Power System Management Protocol Specification Part I General Requirements, Transport And Electrical Interface

CANopen IO X1 Fact sheet

SENtral Demo Module Quick Guide

CANopen Firmware. for PCAN-MicroMod. User Manual

Modbus RTU Protocol description

Wall. No opening (Example: LA-030-W)

CAN Option for FlexDrive II, Flex+Drive II and MintDrive II. Reference Manual 10/02 MN1909

Motors Automation Energy Transmission & Distribution Coatings. Software WSCAN. User's Manual

PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors

CANopen IO X2 Fact sheet

Zikodrive ZD10LCD Stepper Motor Controller (Pump Mode) Quick Start Guide and User Manual

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

Option H8.x and H12.x External I/O modules Description of option Functional description

What s in the Box? Weatherproof Camera transmitter with Antenna Power Cable 3m Sticker. 2 RVS SyStemS

DeviceNett Option. for FlexDrive II, Flex+Drive II and MintDrive II. Reference Manual 10/02 MN1910

SGH. SGH inch stroke range, no terminating resistor 5-pin M12 mating plug, mounting bracket. CANopen Output Signal SGH-80-4-TR

Install Motor Controller User Manual

RSTC1000 HMI/PLC Design Guide WEB CONTROL PRODUCTS. User Manual FORM NO. L B MTY (81)

SKH. CANOpen Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation

CANopen User manual Website: Technical Support: Skype: Phone: QQ: Technical forum:

SINAMICS S120. SINAMICS S120 CANopen interface. Commissioning Manual 10/2008 CANopen interface SINAMICS

ARCTIC AIR DC OLED. Digital Control Operations Manual

LCD62. Keypad. User Manual

Connection Procedure of WAGO CANopen Bus Coupler and Pro-face AGP-3****-CA1M/LT. Instruction Manual. Version1.1 (

Technical Documentation 0630

Doc ID: S94CAN01A S921. CANopen Communication Module S94CAN01A

LVD Digital Servo Drive

User Manual. MK6i RFM Module. 1 General. DEALER: Keep this manual. The procedures in this manual MUST be performed by a qualified technician.

Data Reporter. Installation-Operation E rev.f

V ARIENSE SENSE Y O UR W ORLD. Inertial Measurement Unit VMU931. User Guide. Version 1.3. March VARIENSE INC.

PCAN-MicroMod CANopen CANopen Firmware for PCAN-MicroMod. User Manual V1.1.1

Embedded Motion Control Library

I2:34 MODEL TSTATBBP2W01 PROGRAMMABLE DIGITAL THERMOSTAT. Heat only, or Cool only. Meets California Title 24 Residential USERS INFORMATION MANUAL

User Manual for XL-J1939

User manual. Inclinometer with CANopen-Interface IK360

Media Control Station 2 MIDI Version User's Manual Third Edition

Sensoray Model 627 CompactPCI to PCI Adapter

PixController, Inc. Wireless Magnetic Switch Sensor For Doors, Windows, and Gates

Embeddable Digital Video Recorder with Incremental Encoder Interface. Hardware Manual

User s manual. Evolution Multimedia device for domotic control in SmartLiving systems User s manual

Powered Roller Controller for DeviceNet

BACNet Gateway Option

Software Developer's Manual

Digi-Pas Innovation & Technology Driven

CANopen Commandline Tool

F²MC-16FX FAMILY ALL SERIES FLASH SECURITY 16-BIT MICROCONTROLLER APPLICATION NOTE. Fujitsu Microelectronics Europe Application Note

BusBlock Analog Input Module for the Smart Distributed System

CAN OPEN DP404 Digital Output

OZONE SWITCH Model OS-6. OS-6 Features

Resolver to Digital Expansion Board

MAG. Explorer. Reference for the latest revision of the Magnetek Explorer software

FACTORY AUTOMATION. MANUAL R CANopen Protocol

INSTRUCTION MANUAL. Model 600C Radio Remote Control Handset

Transcription:

60510002 CAN GATEWAY MESSAGING REFERENCE MANUAL CANopen MESSAGING Prerequisite Knowledge It is assumed that the reader has some level of familiarity with CANopen networking and terminology, and the Akron Brass product. This information is not intended to be a tutorial on CANopen, nor Akron Brass product operation, but rather a resource for information concerning the requirements and techniques involved in implementing a CANopen control interface to the Akron Brass product line through the 6051 CAN Gateway. CAN Physical Layer The CANopen side of the 6051 Gateway physical layer characteristics are generally as follows: 11 bit CAN message headers User-configurable bit rate of 10K, 20K, 50K, 125K, 250K, 500K, 800K or 1M bits per second Proper bus wiring, terminations, etc. General Message Characteristics Communication via the 6051 CAN Gateway uses the CANopen Predefined Connection Set as specified in CiA 301 CANopen Application Layer and Communication Profile. The messages are structured as follows: Bit 11.9 8...1 [.. ][...] [.. ] 7 bits, Node-ID 4 bits, Function code Data length - 1 to 8 bytes Data bytes 1-8 = Data for message ( 1 to 8 bytes ) CAN Gateway Defaults Gateway CANopen side data rate and node usage are configurable, supporting up to 6 monitors concurrently. Factory default configuration parameters are: CANopen data rate of 125K bits per second Gateway assigned CANopen node 70 hex ( 112 dec ) One monitor active, assigned CANopen node 24 hex ( 36 dec ) These defaults are used in the explanations and examples in the remainder of this document. 123695

SDO 0x1000.00 CiA DS 301 Device Type ( Read Only ) The 6051 CAN Gateway device supports this standard SDO for itself and attached monitors, but note that all devices will return 00000000 hex for the device type, as none use a standard CANopen device profile. The Gateway device provides 0x5xxx.xx vendor-specific SDOs for access to certain information about itself and any attached monitors. Request: Header = 624 hex ( monitor ) 670 hex ( gateway ) Data length 4 bytes Data = 40 00 10 00 hex Response: Header = 5A4 hex ( monitor ) 5F0 hex ( gateway ) Data length 8 bytes Data = 43 00 10 00 00 00 00 00 hex Example Request: [ header ] 624 hex [ 4 data bytes ] 40 00 10 00 hex Response: [ header ] 5A4 hex [ 8 data bytes ] 43 00 10 00 00 00 00 00 hex This exchange only verifies the presence of a device at CANopen node-id 24 hex. SDO 0x5000.01 must be used to determine actual device characteristics. Page 02

SDO 0x5000.01 Akron Brass Device Type ( Read Only ) Request: Header = 624 hex ( monitor ) 670 hex ( gateway ) Data length 4 bytes Data = 40 00 50 01 hex Response: Header = 5A4 hex ( monitor ) 5F0 hex ( gateway ) Data length 8 bytes Byte 1 2 3 4 5 6 7 8 Bit 8...1 8...1 8...1 8...1 8...1 8...1 8...1 8...1 [...] [...] [...] [...] [............] [...] [...] [...] [...] [............] [...] [...] [...] [...] 32 bits ( low - high ) unsigned, Device type [...] [...] [...] 1 byte, response data byte 4, 01 hex [...] [...] 1 byte, response data byte 3, 50 hex [...] 1 byte, response data byte 2, 00 hex 1 byte, response data byte 1, 43 hex Example Request: [ header ] 624 hex [ 4 data bytes ] 40 00 50 01 hex Response: [ header ] 5A4 hex [ 8 data bytes ] 43 00 50 01 16 69 98 03 hex This exchange determines that the unit at CANopen node-id 24 hex is: Akron Brass part 60320022 ( style 3463 Firefox with Novotechnik sensors ) [ Device type = ( low - high ) 00010110 01101001 10011000 00000011 = ( unsigned 32 bit ) 00000011 10011000 01101001 00010110 = 03986916 hex = 60320022 dec ] Page 03

SDO 0x5001.01 Akron Brass System Fault Status ( Read Only ) Request: Header = 624 hex ( monitor ) 670 hex ( gateway ) Data length 4 bytes Data = 40 01 50 01 hex Response: Header = 5A4 hex ( monitor ) 5F0 hex ( gateway ) Data length 8 bytes Byte 1 2 3 4 5 6 7 8 Bit 8...1 8...1 8...1 8...1 8...1 8...1 8...1 8...1 [...] [...] [...] [...] [...] [..] [..] [...] [...] [...] [...] [...] [..] [..] Internal EEPROM fault [...] [...] [...] [...] [...] [..] [..] Motor Axis 1 fault [...] [...] [...] [...] [...] [..] [..] Motor Axis 2 fault [...] [...] [...] [...] [...] [..] [..] Motor Axis 3 fault [...] [...] [...] [...] [...] [..] [..] Motor Axis 4 fault [...] [...] [...] [...] [...] [..] [..] Motor Axis 5 fault [...] [...] [...] [...] [...] [..] [..] Digital Output 1 fault [...] [...] [...] [...] [...] [..] [..] Digital Output 2 fault [...] [...] [...] [...] [...] [..] [..] Digital Output 3 fault [...] [...] [...] [...] [...] [..] 4 bits ( unused ) [...] [...] [...] [...] [...] [..] SCI input overrun [...] [...] [...] [...] [...] [..] CAN input overrun [...] [...] [...] [...] [...] [..] XGATE processor code fault [...] [...] [...] [...] [...] [..] pcode syntax error [...] [...] [...] [...] [...] 4 bits ( unused ) [...] [...] [...] [...] [...] Internal fuse blown [...] [...] [...] [...] [...] 1 bit ( unused ) [...] [...] [...] [...] [...] External EEPROM fault [...] [...] [...] [...] 5 bits ( unused ) [...] [...] [...] [...] SCI output overrun [...] [...] [...] [...] CAN output overrun [...] [...] [...] [...] S12 processor code fault [...] [...] [...] 1 byte, response data byte 4, 01hex [...] [...] 1 byte, response data byte 3, 50 hex [...] 1 byte, response data byte 2, 01 hex 1 byte, response data byte 1, 43 hex Example Request: [ header ] 624 hex [ 4 data bytes ] 40 01 50 01 hex Response: [ header ] 5A4 hex [ 8 data bytes ] 43 01 50 01 00 20 00 00 hex This exchange determines that the system fault status of the unit at CANopen node-id 24 hex is: Internal fuse blown [ system error bit map = xxxxxxxx xx1xxxxx xxxxxxxx xxxxxxxx = Internal fuse blown ] Page 04

SDO 0x5001.02 Akron Brass Operational Error Code ( Read Only ) Request: Header = 624 hex Data length 4 bytes Data = 40 01 50 02 hex Response: Header = 5A4 hex Data length 6 bytes Byte 1 2 3 4 5 6 Bit 8...1 8...1 8...1 8...1 8...1 8...1 [...] [...] [...] [...] [......] [...] [...] [...] [...] word, Operational Error Code [...] [...] [...] 1 byte, response data byte 4, 02 hex [...] [...] 1 byte, response data byte 3, 50 hex [...] 1 byte, response data byte 2, 01 hex 1 byte, response data byte 1, 4B hex Example Request: [ header ] 624 hex [ 4 data bytes ] 40 01 50 02 hex Response: [ header ] 5A4 hex [ 6 data bytes ] 4B 01 50 02 0B 00 hex This exchange determines that the operational error code of the unit at CANopen node-id 24 hex is: 11 ( Rotation Sensor error ) [ Operational Error Code = ( low - high ) 00001011 0000000 = ( unsigned 16 bit ) 00000000 00001011 = 000B hex =11 dec ] Values in Operational Error code correspond to Error Flash Codes in the reference manual for the specific device. Page 05

SDO 0x5002.01 Akron Brass Zero Axis Positions request ( Write Only ) Request: Header = 624 hex Data length 5 bytes Data = 2F 02 50 01 41 hex Response: Header = 5A4 hex Data length 4 bytes Data = 60 02 50 01 hex Example Request: [ header ] 624 hex [ 5 data bytes ] 2F 02 50 01 41 hex Response: [ header ] 5A4 hex [ 4 data bytes ] 60 02 50 01 hex This exchange with the unit at CANopen node-id 24 hex causes the device to set its zero positions for rotation and elevation to their current positions. This SDO write is only accepted and acknowledged by controllers supporting monitors with analog position feedback, allowing the integrator to set zero axis positions via CANopen. Page 06

SDO 0x5002.02 Akron Brass Reset Controller request ( Write Only ) Request: Header = 624 hex Data length 5 bytes Data = 2F 02 50 02 45 hex Response: Header = 5A4 hex Data length 4 bytes Data = 60 02 50 02 hex Example Request: [ header ] 624 hex [ 5 data bytes ] 2F 02 50 02 45 hex Response: [ header ] 5A4 hex [ 4 data bytes ] 60 02 50 02 hex This exchange with the unit at CANopen node-id 24 hex causes the device to perform a power on reset. This SDO write results in an immediate reset of the target unit. The response is provided by the CAN Gateway to maintain compatibility with the CANopen protocol. Page 07

SDO 0x5002.03 Akron Brass Enter Setup Mode request ( Write Only ) Request: Header = 624 hex Data length 5 bytes Data = 2F 02 50 03 46 hex Response: Header = 5A4 hex Data length 4 bytes Data = 60 02 50 03 hex Example Request: [ header ] 624 hex [ 5 data bytes ] 2F 02 50 03 46 hex Response: [ header ] 5A4 hex [ 4 data bytes ] 60 02 50 03 hex This exchange with the unit at CANopen node-id 24hex causes the device to enter setup mode. This SDO write has the same effect as powering up the target control with the Stream command input active. Page 08

CiA DS 301 Network Management The 6051 CAN Gateway provides support for the following standard NMT commands for itself and attached monitors: Header = 000 hex Data length 2 bytes Data = cc nn cc: 01 hex = Start / Run 81 hex = Reset Node nn: node-id, 00 hex = all nodes Example: [ header ] 000 hex [ 2 data bytes ] 01 00 hex This request places the gateway and all attached monitors into the Operational state. CiA DS 301 Heartbeat The 6051 CAN Gateway provides support for this message for itself and attached monitors. It is enabled and set to 1000ms ( 1 second ) interval for all devices by default. Header = 724 hex ( monitor ) 770 hex ( gateway ) Data length 1 byte Data: 00 hex Node just powered on (initial transmission only) 7F hex Node is in Pre-Operational state 05 hex Node is in Operational state Example: [ header ] 724 hex [ 1 data byte ] 05 hex This message indicates the device at CANopen node-id 24 hex is in the Operational state. Page 10

Monitor RPDO1 Joystick Command Message COB id = 00000224 hex Header = 0x200 + Node-ID Data length 8 bytes Byte 1 2 3 4 5 6 7 8 Bit 8...1 8...1 8...1 8...1 8...1 8...1 8...1 8...1 [][][][] [...] [][][][] [...] [][][..] [][][][] [][][][] [][][][] [][][][] [...] [][][][] [...] [][][..] [][][][] [][][][] [][][] Switch 12 status [][][][] [...] [][][][] [...] [][][..] [][][][] [][][][] [][] Switch 11 status [][][][] [...] [][][][] [...] [][][..] [][][][] [][][][] [] Switch 10 status [][][][] [...] [][][][] [...] [][][..] [][][][] [][][][] Switch 9 status [][][][] [...] [][][][] [...] [][][..] [][][][] [][][] Switch 8 status [][][][] [...] [][][][] [...] [][][..] [][][][] [][] Switch 7 status [][][][] [...] [][][][] [...] [][][..] [][][][] [] Switch 6 status [][][][] [...] [][][][] [...] [][][..] [][][][] Switch 5 status [][][][] [...] [][][][] [...] [][][..] [][][] Switch 4 status [][][][] [...] [][][][] [...] [][][..] [][] Switch 3 status [][][][] [...] [][][][] [...] [][][..] [] Switch 2 status [][][][] [...] [][][][] [...] [][][..] Switch 1 status [][][][] [...] [][][][] [...] [][] 4 bits ( unused ) [][][][] [...] [][][][] [...] [] Y detent status ( ignored by Akron Brass devices ) [][][][] [...] [][][][] [...] X detent status ( ignored by Akron Brass devices ) [][][][] [...] [][][][] 8 bits, Y deflection ( high ) unsigned, 0.1% [][][][] [...] [][][] Y neutral status [][][][] [...] [][] Y back ( - ) status [][][][] [...] [] Y forward ( + ) status [][][][] [...] 2 bits, Y deflection ( low ) unsigned, 0.1% [][][][] 8 bits, X deflection ( high ) unsigned, 0.1% [][][] X neutral status [][] X left ( - ) status [] X right ( + ) status 2 bits, X deflection ( low ) unsigned, 0.1% ( 2 bit status field values: 00 = Off, 01 = On, 10 = Error, 11 = N/A ) Example [ header ] 224 hex [ 8 data bytes ] 10 7D 04 64 00 10 00 00 hex This Joystick Command message to the Akron Brass monitor at CANopen Node-ID 24 hex indicates: Rotate Right is commanded at 50% speed [ X deflection = ( low high ) 00... 01111101 = ( unsigned 10 bit )...01 11110100 = 1F4 hex = 500 dec = 50.0% ] [ X right (+) status =..01... = On ] Elevate Up is commanded at 40% speed [ Y deflection = ( low high ) 00... 01100100 = ( unsigned 10 bit )...01 10010000 = 190 hex = 400 dec = 40.0% ] [ Y back (-) status =...01.. = On ] Pattern Fog is commanded [ Switch 2 status =..01... = On ] Refer to Appendix A for detailed switch input mapping, message timing requirements, and information on how Joystick Command input is handled by Akron Brass devices. Page 11

Monitor TPDO1 Monitor Position / Limit Status This message is issued periodically (default 100ms) by 6032 Universal II, 6040 Forestry, 6042 Global Platform and 6052 StreamMaster II units to indicate axis positions (units with analog feedback), travel limit status, et.al. COB id = 400001A4 hex, transmission type = FE hex ( event driven, manufacturer specific ) Header = 1A4 hex Data length 8 bytes Byte 1 2 3 4 5 6 7 8 Bit 8...1 8...1 8...1 8...1 8...1 8...1 8...1 8...1 [...] [......][][] [......][][] [][][][] [][][][] [][][][] [...] [......][][] [......][][] [][][][] [][][][] [][][] Calibration status [...] [......][][] [......][][] [][][][] [][][][] [][] Operational Error Code set [...] [......][][] [......][][] [][][][] [][][][] [] Axis 5(-) hard stop status [...] [......][][] [......][][] [][][][] [][][][] Axis 5(+) hard stop status [...] [......][][] [......][][] [][][][] [][][] Axis 4(-) hard stop status [...] [......][][] [......][][] [][][][] [][] Axis 4(+) hard stop status [...] [......][][] [......][][] [][][][] [] Axis 3(-) hard stop status [...] [......][][] [......][][] [][][][] Axis 3(+) hard stop status [...] [......][][] [......][][] [][][] Axis 2(-) hard stop status [...] [......][][] [......][][] [][] Axis 2(+) hard stop status [...] [......][][] [......][][] [] Axis 1(-) hard stop status [...] [......][][] [......][][] Axis 1(+) hard stop status [...] [......][][] [......][] Elevation Down(-) position status [...] [......][][] [......] Elevation Up(+) position status [...] [......][][] 12 bits ( high - low ) unsigned, Elevation position, 0.1 [...] [......][] Rotation Left(-) position status [...] [......] Rotation Right(+) position status [...] 12 bits ( high - low ) unsigned, Rotation position, 0.1 8 bits, message type, 00000001 = 01 hex 2 bit status field values: 00 = Off, 01 = On, 10 = Error, 11 = N/A axis (+) position status = 01, axis (-) position status = 00 and axis position = 0xFFF indicates axis sensor error axis (+) position status = 11, axis (-) position status = 11 and axis position = 0xFFF indicates analog feedback option not present on axis Example [ header ] 1A4 hex [ 8 data bytes ] 01 1D 94 03 71 00 00 01 hex This message from the Akron Brass monitor at CANopen node-id 24 hex indicates: Rotation position is +47.3 [ Axis 0 position = ( high low ) 00011101 1001... = ( unsigned 12 bit )...0001 11011001 = 1D9 hex = 473dec = 47.3 ] [ Axis 0 (+) position status =...01.. = On ] Elevation position is -5.5 [ Axis 1 position = ( high low ) 00000011 0111... = ( unsigned 12 bit )...0000 00110111 = 037 hex = 55dec = 5.5 ] [ Axis 1 (-) position status =...01 = On ] Unit has been calibrated [ Calibration status =...01 = On ] Refer to Appendix B for default axis usage for Akron Brass monitors. Note that Operational Error Code set status of 01 (On) indicates that an Operational Error has been encountered and the unit is operating in a reduced functionality mode. SDO 0x5001.02 should be used to retrieve the error code and determine required action. Page 12

Monitor TPDO2 Digital Output Status This message is issued periodically (default 100ms) by the 6032 Universal II, 6040 Forestry, 6042 Global Platform and 6052 StreamMaster II units to indicate status of various digital outputs. COB id = 400002A4 hex, transmission type = FE hex ( event driven, manufacturer specific ) Header = 2A4 hex Data length 3 bytes Byte 1 2 3 Bit 8...1 8...1 8...1 [...]...... [...]...... Status (panel) LED [...]...... Status (point-aim) LED [...]...... Monitor not in exclusion zone (ladder avoidance) [...]...... Remote mode (portable battery powered monitor) [...]...... Status (wireless hand-held) LED [...]..... Monitor high-flow status [...].... Discharge valve status [...]... Dry chemical dispense status [...]... Electric riser command bits [...]... reserved [...]... reserved [...]... reserved [...].. reserved [...]. Monitor Active status [...] Enable input status 8 bits, message type, 10000011 = 83hex Example [ header ] 2A4 hex [ 3 data bytes ] 83 00 01 hex This message from the Akron Brass monitor at CANopen node-id 24 hex indicates: Panel LED is on [ Panel LED status =......1 = On ] Monitor is active [ Monitor Active status =.1...... = On ] Enable input is active [ Enable input status = 1...... = On ] Note that if an Operational Error has been encountered and the unit is operating in a reduced functionality mode, Panel LED status will be blinking out the error code. Refer to TPDO1 for more information. Note that Monitor Active status is not set if the monitor is stowed, and is set if the monitor is in any other state. Note that if the Enable input is not active, CAN communication will continue, but no motor movement requests will be honored. Motor movement will be allowed to resume when the Enable input returns to active status. Page 13

Appendix A Handling of Joystick Command messages Joystick inputs are mapped to 6032 Universal II, 6040 Forestry, 6042 Global Platform and 6052 StreamMaster II inputs as follows: X axis right - Rotate Right with proportional speed control X axis left - Rotate Left with proportional speed control Y axis back - Elevate Up with proportional speed control Y axis forward - Elevate Down with proportional speed control Switch 1 - Pattern Stream Switch 2 - Pattern Fog Switch 3 - Discharge On Switch 4 - Oscillate On Set Switch 5 - Flow High Switch 6 - Flow Low Switch 7 - Oscillate Pause Resume Switch 8 - Deploy Switch 9 - Stow Switch 10 - Discharge Off Switch 11 - CAFS dry mode Switch 12 - CAFS wet mode On the Akron Brass CAN bus, the units will accept input requests from multiple sources and will try to honor any and all non-conflicting requests. Conflicting requests will be handled according to the following default priority scheme (meaning input requests from a particular source will override conflicting requests from all lower priority sources): Highest priority Physical input switches ( only available on 6032 Universal II ) CAN device at node address 33 hex CAN device at node address 34 hex CAN device at node address 35 hex CAN device at node address 36 hex CAN device at node address 37 hex CAN device at node address 38 hex Lowest priority By default, all control devices [ 6035 Joystick, 6037 Wireless Interface, 6041 Switchbox, 6051 CAN Gateway, and any integrator device(s) ] appear to Akron Brass controllers as a J1939 joystick at one of the above addresses broadcasting Joystick Command messages. Joystick Command messages are expected to be broadcast on a periodic basis, every 100ms or less (Akron Brass control devices default to every 20ms). As a safety precaution against control device failure or CAN bus interruption, the controller monitors message timing and if it does not receive any message from an input device (CAN node address) for 200ms, the input buffer for that CAN node is cleared, stopping any manual motion that was being requested by that device. Page 14

Appendix B Default Axis Usage for Akron Brass Monitors 6032 Universal II controller Axis 1: Rotation, (+) = right, (-) = left Axis 2: Elevation, (+) = up, (-) = down Axis 3: Pattern, (+) = stream, (-) = fog Axis 4: Monitor specific Trident Dual Gallonage: Flow control, (+) = high flow, (-) = low flow DeckMaster: Swing arm, (+) = deploy, (-) = stow Others: N/A Axis 5: Discharge valve, (+) = open, (-) = close 6040 Forestry controller Axis 1: Rotation, (+) = right, (-) = left Axis 2: Elevation, (+) = up, (-) = down Axis 3: Pattern, (+) = stream, (-) = fog Axis 4: Discharge valve, (+) = open, (-) = close 6042 Global Platform controller Axis 1: Rotation, (+) = right, (-) = left Axis 2: Elevation, (+) = up, (-) = down Axis 3: Pattern, (+) = stream, (-) = fog 6052 StreamMaster II controller Axis 1: Rotation, (+) = right, (-) = left Axis 2: Elevation, (+) = up, (-) = down Axis 3: Pattern, (+) = stream, (-) = fog Page15

PHONE: 330.264.5678 or 800.228.1161 I FAX: 330.264.2944 or 800.531.7335 I akronbrass.com revised: 11/15 WARRANTY AND DISCLAIMER: We warrant Akron Brass products for a period of five (5) years after purchase against defects in materials or workmanship. Akron Brass will repair or replace product which fails to satisfy this warranty. Repair or replacement shall be at the discretion of Akron Brass. Products must be promptly returned to Akron Brass for warranty service. We will not be responsible for: wear and tear; any improper installation, use, maintenance or storage; negligence of the owner or user; repair or modification after delivery; damage; failure to follow our instructions or recommendations; or anything else beyond our control. WE MAKE NO WARRANTIES, EXPRESS OR IMPLIED, OTHER THAN THOSE INCLUDED IN THIS WARRANTY STATEMENT, AND WE DISCLAIM ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Further, we will not be responsible for any consequential, incidental or indirect damages (including, but not limited to, any loss of profits) from any cause whatsoever. No person has authority to change this warranty. ISO 9001 REGISTERED COMPANY Akron Brass Company. 2012 All rights reserved. No portion of this can be reproduced without the express written consent of Akron Brass Company.